Powered by Deep Web Technologies
Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Annotated Bibliography of UHV AC Substation Equipment, 1968-1985.  

SciTech Connect

This bibliography is divided into sections dealing with insulation coordination, switchgear, shunt reactors, surge arresters, power transformers, current and voltage measurement equipment, station design and operating experience, and testing facilities. (DLC)

Lava, Val

1985-08-01T23:59:59.000Z

2

Proceedings: Tenth EPRI Substation Equipment Diagnostics Conference  

SciTech Connect

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The tenth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2002-06-01T23:59:59.000Z

3

Proceedings: Substation Equipment Diagnostics Conference IX  

SciTech Connect

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The ninth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2001-09-01T23:59:59.000Z

4

Proceedings: Substation Equipment Diagnostics Conference VIII  

SciTech Connect

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The eighth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2000-06-01T23:59:59.000Z

5

MOV surge arresters: improved substation equipment protection  

SciTech Connect

The introduction of metal-oxide-varistor (MOV) surge arresters has added a new dimension to substation equipment protection. Through the optimal use of these arresters, it is possible to lower surge arrester ratings and thereby improve protective margins, resulting in a possible reduction of the insulation levels (BIL) of substation equipment. This reduction in BIL can lead to a significant reduction in the cost of substation equipment. General methods are delineated for selecting MOV surge arresters for substation protection and the resulting effect on substation equipment insulation levels.

Niebuhr, W.D.

1985-07-01T23:59:59.000Z

6

Design of AC substation grounding system.  

E-Print Network (OSTI)

??The purpose for this paper is to understand the basic foundation used to safely design a substation grounding system for AC systems. The following criteria… (more)

Meas, Ra

2014-01-01T23:59:59.000Z

7

Seismic fragility analysis of equipment and structures in a Memphis Electric substation. Technical report  

SciTech Connect

This report presents a seismic fragility analysis of equipment and structures in an electric substation in Memphis, Tennessee. These include the pothead structure, 115 kv switch structure, 97 kv lightning arresters, control house, capacitor banks, 115/12 kv transformers, 12 kv regulators, 115 kv oil circuit breakers, and 12 kv oil circuit breakers. The results from this fragility analysis provide the expected performance of equipment and structures in a substation. They can also be used to evaluate the seismic performance of the entire electric substation and to perform a system reliability analysis of the electric transmission system.

Huo, J.R.; Hwang, H.H.M.

1995-08-10T23:59:59.000Z

8

RECORD OF CATEGORICAL EXCLUSION DETERMINATION Ault Substation Expansion and Equipment Additions, Weld County, CO  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ault Substation Expansion and Equipment Additions, Weld County, CO Ault Substation Expansion and Equipment Additions, Weld County, CO A. Proposed Action: Western proposes to expand the existing Ault SUbstation and add electrical equipment. The expansion would be within the existing fee-owned land. B. Number and Title of Categorical Excluison Being Applied . B4.11: Construction of electric power substations (including switching stations and support facilities) with power deliver at 230-kV or below, or modification (other than voltage increases) of existing sutstations and support facilities .. .. C. Regulatory Requirements in 10 CFR 1021.410(b): (Refer to full text in regulation ). (1) The proposed action fits within a class of actions that is listed in Appendix A or B to Subpart D. For classes of actions, listed in Appendix B, the following conditions are

9

Coordination of a distribution level continuously controlled compensation device with existing substation equipment for long term VAR management  

SciTech Connect

The implementation of a continuously controlled reactive compensation device, such as an SVC or a static condenser'' (STATCON), in a distribution-level substation provides opportunities to improve power quality and reliability due to the speed of response of such a device. Further benefits can be gained by coordinating the reactive compensation device and its related controls with other substation voltage control equipment, such as load tap changing (LTC) transformers and mechanically-switched capacitors. The results presented in this paper illustrate the impact that a [+-] 12 Mvar STATCON can have on a 150 MW, 12.5 kV load bus, in the Commonwealth Edison power system. Three control concepts for various levels of integration of the substation STATCON, LTCs, and mechanically-switched capacitors are presented. With broader application of SVCs and STATCONs at distribution substations, various other control strategies may also evolve.

Paserba, J.J.; Leonard, D.J.; Miller, N.W. (GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.); Lauby, M.G. (Electric Power Research Inst., Palo Alto, CA (United States)); Naumann, S.T. (Commonwealth Edison Co., Chicago, IL (United States)); Sener, F.P. (PHE Consulting, Brecksville, OH (United States))

1994-04-01T23:59:59.000Z

10

Research on Smart Substation Equipment Condition Monitoring System Based on Wireless Sensor Networks  

Science Journals Connector (OSTI)

Reference to characteristics of wireless sensor networks (WSNs) technology and the three-tier architecture of smart substation, the paper designs an on-line condition monitoring system of smart substation equipme...

Jie He; Xiaoqing Huang; Yang Yang

2012-01-01T23:59:59.000Z

11

Powerline Communication System for Monitoring and Supervision of Feeder Equipments for MV Substation Automation  

E-Print Network (OSTI)

Substation Automation LiPing LU1,2 , GangYan LI1 , YeQiong SONG2 1 ­ School of Mechanical and Electronical With the deregulation of power market and for providing better services to electric consumers, the current substation into the substations by the utilities to integrate data from relays and Intelligent Electronic Devices (IEDs

Paris-Sud XI, Université de

12

Numerical calculation of AC substation grounding systems buried in a vertical multilayered earth model by higher-order basis function  

Science Journals Connector (OSTI)

To study the accuracy of numerical simulations for an AC substation grounding problem embedded in a vertical multilayered earth model, this paper proposes a novel algorithm combining the rapidly convergent one-dimensional Galerkin's BEM with higher-order ... Keywords: Green's function, high-order basic function, vertical multilayered earth model

Zhong-Xin Li; Jian-Bin Fan; Yu Yin

2012-05-01T23:59:59.000Z

13

Substation automation gains momentum with modern options  

SciTech Connect

This paper discusses issues associated with utility substation automation. Monitoring equipment for monitoring power flow, quality, and harmonics for three substations simultaneously is described.

Beaty, W.

1996-12-01T23:59:59.000Z

14

Substation voltage upgrading  

SciTech Connect

Substation voltage uprating, i.e., conversion of a substation from a lower rated voltage to a higher rated voltage without a complete substation rebuild, can lead to excellent economic benefits. Utilization of the old substation layout and/or the existing equipment, to some extent, is the practical objective of such an uprating. The objective of this project was to assess the opportunities for substation uprating in the industry, to establish feasibility for such uprating and to study methods for accomplishing it. The final aim of the project was to provide guidance to utilities interested in uprating. 56 refs., 41 figs., 18 tabs.

Panek, J.; Elahi, H.; Sublich, M. (General Electric Co., Schenectady, NY (USA). Systems Development and Engineering Dept.)

1989-08-01T23:59:59.000Z

15

Redesign process of a 765 kVRMS AC substation connector by means of 3D-FEM simulations  

Science Journals Connector (OSTI)

Abstract This paper shows the capabilities of applying the three-dimensional finite element method (3D-FEM) for designing complex-shaped substation connectors to operate at 765 kVRMS AC. To check this methodology, it was analyzed the feasibility of upgrading a 400 kVRMS substation connector to operate at 765 kVRMS. However, both experimental and simulation results conducted according to the ANSI/NEMA CC 1-2009 standard concluded that although it passed the visual corona test, to ensure a wide safety margin it was desirable an improvement of the electrical behavior of such connector. It was shown that FEM results allowed detecting the peak stress points of the connector regarding the electrical stress thus allowing applying a corrective action. Then, two possible solutions were analyzed, i.e. the use of corona shields and the redesign of the connector assisted by 3D-FEM simulations. Results presented in this work show that both approaches have an excellent behavior in reducing the electric field strength on the connector surface. However, to make the final decision, the production cost of both alternatives was analyzed, thus favoring the redesign option. Next, the redesigned version of the substation connector was manufactured and tested. Experimental results conducted in a high voltage laboratory verified the effectiveness of the methodology and the potential of the proposed system to act as an advanced design tool for optimizing the behavior of complex-shaped substation connectors. Thus, this system allows assisting efficiently the design process while permitting constraining the economic costs.

Joan Hernández-Guiteras; Jordi-Roger Riba; Luís Romeral

2014-01-01T23:59:59.000Z

16

Life cycle assessment of electricity transmission and distribution—part 2: transformers and substation equipment  

Science Journals Connector (OSTI)

The purpose of this paper is to characterize the environmental impacts of equipment used in power transmission and distribution. This study is divided in two parts, each addressing different main components of th...

Raquel Santos Jorge; Troy R. Hawkins…

2012-02-01T23:59:59.000Z

17

The influence of tropical operating conditions on the AC and impulse breakdown strength in gas insulated substation (GIS):.  

E-Print Network (OSTI)

??The ambient conditions could influence the breakdown strength of gas insulated substation. It is important to check if this influence will put the GIS into… (more)

Sihombing, H.

2009-01-01T23:59:59.000Z

18

Recent developments in subtransmission substations  

SciTech Connect

Equipment is described which offers the utility engineer flexibility in the layout and location of substations. It is possible with these designs to place HV connected substations directly into load centers and reduce the losses with connections at a lower voltage level. An added advantage of these designs are reduced expenses for engineering, site preparation, foundations, installation and interest payments due to the shorter time between equipment delivery and possible energization of a substation. Reduced maintenance, longer maintenance intervals, small gas leakage, are built-in advantages of this equipment.

Watson, P.W.; Leibold, A.A.; Koglin, B.B.

1980-05-01T23:59:59.000Z

19

Substation grounding.  

E-Print Network (OSTI)

??Designing a proper substation grounding system is quite complicating. Many parameters affect its design. In order for a grounding design to be safe, it needs… (more)

Baleva, Inna

2012-01-01T23:59:59.000Z

20

Cutting costs through substation ownership  

SciTech Connect

The term applied to service through a customer-owned main substation is primary service, and such customers are billed at primary metering rates. These terms denote that the customer accepts service (and billing metering is located) on the primary, rather than secondary, side of the main transformer. Some electric utilities are prepared to offer extremely attractive billing reductions to those customers willing to invest in their own main substations instead of renting a substation purchased with utility company capital. Depending on the utility and the particular circumstances, some plants can recover their investment in primary substation equipment in as little as 1 or 2 years.

Keithly, D. (ABB Electric, Waukesba, WI (US))

1989-06-22T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Substation Operation  

Science Journals Connector (OSTI)

... THIS book is intended to help the workman to understand the principles of substation operation. It is a good attempt at giving somewhat advanced technical knowledge in such ... ." We are told not to use water to put out a fire at a substation before the station has been made completely " dead." The reason given for this ...

1925-08-01T23:59:59.000Z

22

Chapter 3 - Substation Layouts  

Science Journals Connector (OSTI)

Publisher Summary Substations are the points in the power network, where transmission lines and distribution feeders are connected together through circuit breakers or switches via busbars and transformers. This allows for the control of power flows in the network and general switching operations for maintenance purposes. This chapter describes the principal substation layouts, the effects of advancements in substation equipment, the modular design, the compact substations, and the moves toward design and construction “turnkey” contract work. The descriptions concentrate on air insulated switchgear (AIS) outdoor open terminal designs at rated voltages of 72 kV and higher. In an ideal situation all circuits and substation equipment would be duplicated such that following a fault or during maintenance a connection remains available. This would involve very high cost. Methods have therefore been adopted to achieve a compromise between complete security of supply and capital investment. A measure of circuit duplication is adopted while recognizing that duplication may itself reduce the security of supply by, for example, providing additional leakage paths to earth.

C.R. Bayliss; B.J. Hardy

2012-01-01T23:59:59.000Z

23

CHARACTERISTICS OF IMPULSIVE NOISE IN ELECTRICITY SUBSTATIONS Qingshan Shan1  

E-Print Network (OSTI)

CHARACTERISTICS OF IMPULSIVE NOISE IN ELECTRICITY SUBSTATIONS Qingshan Shan1 , Shahzad Bhatti1.shan@eee.strath.ac.uk, website: www.strath.ac.uk ABSTRACT Measurements of noise in an electricity substation are re- ported-voltage electricity substations, has discouraged electricity utility companies from deploying wireless technologies

Atkinson, Robert C

24

Voltage asymmetry at the buses of a combined substation  

Science Journals Connector (OSTI)

The voltage asymmetry at the buses of a combined (ac/dc) substation is calculated by phase method, using Mathcad ... , power may be supplied to a combined substation along a common line from a limited-...

A. G. Pakulin; V. A. Zagorskii; V. F. Put’ko

2013-07-01T23:59:59.000Z

25

Substation alarm multiplexing system (SAMS)  

SciTech Connect

This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creek substation in the Bronx for the purpose of a three month field evaluation.

ElBadaly, H.; Gaughan, J.; Ward, G.; Amengual, S.

1996-03-01T23:59:59.000Z

26

High voltage electric substation performance in earthquakes  

SciTech Connect

This paper examines the performance of several types of high voltage substation equipment in past earthquakes. Damage data is provided in chart form. This data is then developed into a tool for estimating the performance of a substation subjected to an earthquake. First, suggests are made about the development of equipment class fragility curves that represent the expected earthquake performance of different voltages and types of equipment. Second, suggestions are made about how damage to individual pieces of equipment at a substation likely affects the post-earthquake performance of the substation as a whole. Finally, estimates are provided as to how quickly a substation, at various levels of damage, can be restored to operational service after the earthquake.

Eidinger, J. [G and E Engineering Systems, Oakland, CA (United States); Ostrom, D. [Southern California Edison, Rosemead, CA (United States); Matsuda, E. [Pacific Gas and Electric, San Francisco, CA (United States)

1995-12-31T23:59:59.000Z

27

EA-1671: Big River Substation to Poston Substation 69-Kilovolt...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

671: Big River Substation to Poston Substation 69-Kilovolt Transmission Line Project, Arizona and California EA-1671: Big River Substation to Poston Substation 69-Kilovolt...

28

Electric power substation capital costs  

SciTech Connect

The displacement or deferral of substation equipment is a key benefit associated with several technologies that are being developed with the support of the US Department of Energy`s Office of Utility Technologies. This could occur, for example, as a result of installing a distributed generating resource within an electricity distribution system. The objective of this study was to develop a model for preparing preliminary estimates of substation capital costs based on rudimentary conceptual design information. The model is intended to be used by energy systems analysts who need ``ballpark`` substation cost estimates to help establish the value of advanced utility technologies that result in the deferral or displacement of substation equipment. This cost-estimating model requires only minimal inputs. More detailed cost-estimating approaches are recommended when more detailed design information is available. The model was developed by collecting and evaluating approximately 20 sets of substation design and cost data from about 10 US sources, including federal power marketing agencies and private and public electric utilities. The model is principally based on data provided by one of these sources. Estimates prepared with the model were compared with estimated and actual costs for the data sets received from the other utilities. In general, good agreement (for conceptual level estimating) was found between estimates prepared with the cost-estimating model and those prepared by the individual utilities. Thus, the model was judged to be adequate for making preliminary estimates of typical substation costs for US utilities.

Dagle, J.E.; Brown, D.R.

1997-12-01T23:59:59.000Z

29

The implementation of substation automation coordinated with numerical protection relaying  

SciTech Connect

During 1987 Eskom embarked on a process of defining user requirements in the area of substation control. This ultimately resulted in a project being established for the procurement and development of a new generation of substation control equipment. At the same time it was decided to establish a new generation of protection schemes for transmission substations, based on numerical protection relays. From the outset, a high degree of coordination was planned between the substation control and protection equipment. Development contracts were placed with suppliers during late 1990 for the protection schemes and during early 1991 for the substation control equipment. These contracts are nearing completion and the first large installations will commence during 1994. The Transmission Group has committed to employing this new technology in all new substations and all substations to be refurbished. This paper discusses the concept of coordinated substation control and protection and gives insight into implementation issues and functional compromises which had to be made to meet project deadlines.

Welie, G. van; Carolin, T.

1994-12-31T23:59:59.000Z

30

Microsoft Word - CX_McNaryEquipmentAcquisition.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

to purchase equipment owned by Umatilla Electric Cooperative (UEC) within BPA's McNary Substation. BPA already maintains all of UEC's equipment in the substation under an...

31

Substation evaluation using Diagnostic Logic System (DIALOG)  

SciTech Connect

This project investigated the feasibility of applying a Diagnostic Logic System (DIAGLOG) to evaluate substation operation. The purpose was to see if a determination can be made as to whether the equipment in a substation operated correctly or not when an operating event occurred. The work was directed toward modifying an already proven diagnostic system to create a simplified procedure for describing the operation of substation equipment. Special operating tables or modules of logic were identified for describing relay and breaker operations. The resulting model composed of all the modules connected together is used to evaluate the actual observations available at the substation, and to compare them with what the substation should have produced. The report covers the diagnostic approach used, information on how to construct the modules and examples of diagnosis. Also covered are discussions on the special features of substations that offer a challenge to performing diagnostics. Included in the report are the results of modeling a typical substation and several notes are provided along with an initial library of typical modules which were developed in modeling one of the substations belonging to the Pacific Gas and Electric Company. This substation served as a feasibility demonstrator. 15 figs.

Andre, W.L.

1989-08-01T23:59:59.000Z

32

ZigBee Performance in 400 KV Air Insulated Power Substation  

Science Journals Connector (OSTI)

An experimental assessment of the impact of the electromagnetic environment of a 400 kV substation on the performance of ZigBee equipment is ... the performance of ZigBee equipment deployed in the substation with...

Qingshan Shan; I A Glover; P J Moore…

2010-01-01T23:59:59.000Z

33

Studies of Monitoring and Diagnosis Systems for Substation Apparatus.  

E-Print Network (OSTI)

??Substation apparatus failure plays a major role in reliability of power delivery systems. Traditionally, most utilities perform regular maintenance in order to prevent equipment breakdown.… (more)

Liang, Yishan

2006-01-01T23:59:59.000Z

34

Transient electromagnetic interference in substations  

SciTech Connect

Electromagnetic interference levels on sensitive electronic equipment are quantified experimentally and theoretically in air and gas insulated substations of different voltages. Measurement techniques for recording interference voltages and currents and electric and magnetic fields are reviewed and actual interference data are summarized. Conducted and radiated interference coupling mechanisms and levels in substation control wiring are described using both measurement results and electromagnetic models validated against measurements. The nominal maximum field and control wire interference levels expected in the switchyard and inside the control house from switching operations, faults, and an average lightning strike are estimated using high frequency transient coupling models. Comparisons with standards are made and recommendations given concerning equipment shielding and surge protection.

Wiggins, C.M.; Thomas, D.E.; Nickel, F.S.; Salas, T.M. (BDM International, Inc., Albuquerque, NM (United States)); Wright, S.E. (Electric Power Research Inst., Palo Alto, CA (United States))

1994-10-01T23:59:59.000Z

35

Earth resistivity measurement near substation ground grids  

SciTech Connect

Proper substation grounding grid design requires good, accurate soil resistivity measurements. This data is essential to model the substation ground grid to design a safe ground grid with a satisfactory ground grid resistance at minimum cost. For substations with several decades of service, there is some concern that a grid may have deteriorated, been damaged during equipment installation or excavation, or that initial soil resistivity measurements were lost or may not have been correctly performed. Ground grid conductors change the substation surface voltage distribution. Any voltage measurements taken at the complete substation will also vary from the tests made without conductors present. During testing, current was injected in the soil by probes placed near the ground grid. The current tends to follow the ground grid conductors since copper is a far better conductor than the soil it is placed in. Resistance readings near grids will be lower than readings in undisturbed soil. Since computer models were unavailable for many years, analyzing the effect of the grid conductors on soil resistivity measurements was very difficult. As a result, soil resistivity measurements made close to substations were of little use to the engineer unless some means of correcting the measured values could be developed. This paper will present results of soil resistivity measurements near a substation ground grid before and after a ground grid has been installed and describes a means of calculating the undisturbed soil model.

Lodwig, S.G.; Mateja, S.A. [ComEd, Chicago, IL (United States)

1996-11-01T23:59:59.000Z

36

Application of programmable logic controllers to substation control and protection  

SciTech Connect

This paper describes the application of programmable logic controllers (PLCs) to control and protection of bulk power and regional supply substations. PLC requirements are discussed and the concept of zones of control is explained as applied to standard PP L substation arrangements. The use of a peer-to-peer communication network between logic controllers and other substation equipment is also discussed. Details of an installation completed in spring, 1992, are presented, including experience acquired from power system faults.

Gilbert, J.G.; Diehl, G.R. (Pennsylvania Power Light Co., Allentown, PA (United States))

1994-01-01T23:59:59.000Z

37

Substation fire protection features  

SciTech Connect

This paper describes Commonwealth Edison`s (ComEd) approach to substation fire protection. Substation fires can have a major operational, financial, as well as political impact on a utility. The overall Company philosophy encompasses both active and passive fire protection features to provide prompt detection, notification, and confinement of fire and its by-products. Conservatively designed smoke detection systems and floor and wall penetration seals form the backbone of this strategy. The Company has implemented a program to install these features in new and existing substations. Thus far these measures have been successful in mitigating the consequences of substation fires.

Hausheer, T.G. [Commonwealth Edison Co., Chicago, IL (United States)

1995-10-01T23:59:59.000Z

38

Substation PSA Model  

Science Journals Connector (OSTI)

Chapter 6 describes how to create the substation model, the core of the PSA application... Chap. 4 . First, the modelling principles and then the details of the mode...

Liisa Haarla; Mikko Koskinen; Ritva Hirvonen…

2011-01-01T23:59:59.000Z

39

Substation grounding optimization.  

E-Print Network (OSTI)

??Substation grounding is a critical part of the overall electric power system. It is designed to not only provide a path to dissipate electric currents… (more)

Balev, Vadim

2014-01-01T23:59:59.000Z

40

Substation Expansion Planning  

Science Journals Connector (OSTI)

Consider an 11-load node case as depicted in Fig. 7.1..., fed in 33 kV and to be supplied through high-voltage (HV) substation(s) (say 230 kV:33 kV)... Fig. 7.1 ...

Hossein Seifi; Mohammad Sadegh Sepasian

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Ventilation of Electrical Substations  

Science Journals Connector (OSTI)

... THE type of construction used for substations is generally governed by requirements, for example, fire and air-raid precautions, which ... Electrical Engineers, F. Favell and E. W. Connon record their experiences in overcoming substation ventilation problems in particular cases. Adequate and suitably planned ventilation will maintain ...

1943-05-01T23:59:59.000Z

42

Substation voltage upgrading  

SciTech Connect

This report addresses specific issues to support sound yet not unduly conservative uprating practices for substations. The main parts of the report cover the insulation withstand and overvoltage protection aspects, environmental measurements, reliability criteria, and industry experience. First the insulation design concerns are addressed. Substation stress by a backflashover of the line insulation due to lightning in the vicinity of the substation is recognized as a critical stress. A representative part of a 550 kV BIL substation was erected at the EPRI High Voltage Transmission Research Center, where also a special test circuit was assembled to produce a fast front, slow tail (0.2/200 {mu}s) wave. The substation as well as some special configurations were tested for line-to-ground and line-to-line withstand. Computer studies were performed to complement the test results. A number of important conclusions was reached. The most prominent result in that the high frequency oscillations, as caused by reflections within the substation, do not effect the Critical Flashover Voltage (CFO). The present practice, based on the highest peak is therefore very conservative. The slow tail of the wave appears to dictate the CFO. An arrester model for computer studies to represent very fast as well as slow phenomena was derived. It is based on full scale arrester test data, made available in this project. The computer program to calculate arrester model parameters is also a part of the report. The electric environmental measurements are reported for the tested substation at the HVTRC and for the uprated substation of Public Service Company of Colorado, both before and after the uprating. The performance is satisfactory when corona free hardware is used. Insulation design criteria are analyzed based on substation reliability, the system viewpoint and consequences of the failure. Utility experience with uprated substations is reviewed.

Panek, J.; Elahi, H.; Lux, A.; Imece, A.F. (General Electric Co., Schenectady, NY (United States). Power Systems Engineering Dept.); LaPanse, R.A.; Stewart, J.R. (Public Service Co. of Colorado, Denver, CO (United States))

1992-04-01T23:59:59.000Z

43

Ferroresonance Evaluation at Boushehr 230/400 kV GIS Substation of Iran’s Power Network  

Science Journals Connector (OSTI)

Ferroresonance is one of the main and important reasons to distortion equipments in GIS substations. This phenomenon is not always predictable and ... ferroresonance is necessary to analyze before designing the substation

M. Majidi; H. Javadi; M. Oskuoee

2011-01-01T23:59:59.000Z

44

Substation Configuration Reliability 1 Reliability of Substation Configurations  

E-Print Network (OSTI)

Substation Configuration Reliability 1 Reliability of Substation Configurations Daniel Nack, Iowa substation, it still contains what could be described as weak points or points of failure that would lead to loss of load. By knowing how to calculate the reliability of different substation configurations

McCalley, James D.

45

Sundial Substation Site Baxter Road Substation Site Casey Road  

NLE Websites -- All DOE Office Websites (Extended Search)

Sundial Substation Site Baxter Road Substation Site Casey Road Substation Site Monahan Creek Substation Site YALE DAM MERWIN DAM S i l v e r L a k e Lake Merwin Y a l e L a k e V a...

46

Inter substation data communications  

SciTech Connect

The paper briefly describes the scada system operated by ComEd for substation communications. This system has proven a reliable means for monitor and control of the generation, transmission, and distribution system. An attempt to automate stand-alone substation functions into the RTU has had limited success. An automated substation capacitor control algorithm was incorporated into a PC. The PC directly interfaced with the RTU through the serial port for analog monitoring and control of the capacitor banks. There were no further enhancements or development of other control algorithms with the PC. The paper discusses the power system data evolution, the proposed design improvements, and implementation concerns.

Lukas, M.R. [ComEd, Chicago, IL (United States)

1996-10-01T23:59:59.000Z

47

Substation grounding programs  

SciTech Connect

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 5, is an applications guide of the three computer programs. SOMIP, SMECC, and SGSYS, for the purpose of designing a safe substation grounding system. The applications guide utilizes four example substation grounding systems for the purpose of illustrating the application of the programs, SOMIP, SMECC, and SGSYS. The examples are based on data provided by four contributing utilities, namely, Houston Lighting and Power Company, Southern Company Services, Puget Sound Power and Light Company, and Arizona Public Service Company. For the purpose of illustrating specific capabilities of the computer programs, the data have been modified. As a result, the final designs of the four systems do not necessarily represent actual grounding system designs by these utilities. The example system 1 is a 138 kV/35 kV distribution substation. The example system 2 is a medium size 230 kV/115 kV transmission substation. The third example system is a generation substation while the last is a large 525 kV/345 kV/230 kV transmission substation. The four examples cover most of the practical problems that a user may encounter in the design of substation grounding systems.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

48

Equipment  

Science Journals Connector (OSTI)

...polarized d-c or a-c voltage, or insulation resistance. Range of voltage measurement...Milli-microsecond Time Interval measuring device. SPECIFICATIONS INPUT PULSE RANGE: 5 105v COUNT STORAGE...its use in any convenient location. (Thermal Dynamic Products Inc., Dept. 247...

JOSHUA STERN

1958-08-08T23:59:59.000Z

49

RECORD OF CATEGORICAL EXCLUSION DETERMINATION Hygiene Substation Access Road Repairs  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hygiene Substation Access Road Repairs Hygiene Substation Access Road Repairs A. Brief Description of Proposal: Western Area Power Administration proposes to repair the access road/driveway into the Hygiene Substation. There is a low spot in the middle of the driveway that impedes maneuvering oflarge maintenance equipment in and out of the yard. Western plans to fill the low spot with road base and crumbled concrete fill. The Hygiene Substation is located in Boulder County, approximately 2 miles northwest of Longmont, CO (T3N, R69W, Sec 18). All proposed construction will occur within the existing, disturbed substation access road/driveway. B. Number and Title of tile Categorical Exclusion Being Applied: (See text in 10 CFR 1021, Subpart D.) BI.3 Routine maintenance activities and custodial services for buildings, structures,

50

Substation automation problems and possibilities  

SciTech Connect

The evolutionary growth in the use and application of microprocessors in substations has brought the industry to the point of considering integrated substation protection, control, and monitoring systems. An integrated system holds the promise of greatly reducing the design, documentation, and implementation cost for the substation control, protection, and monitoring systems. This article examines the technical development path and the present implementation problems.

Smith, H.L.

1996-10-01T23:59:59.000Z

51

Substation asset management study  

SciTech Connect

This paper will present an overview of our recent findings in the area of substation asset management and will describe how several utilities, in response to the issues listed above, are re-examining their present maintenance practices in search of more cost-effective programs.

Conroy, M.W.; Conidi, J. [Sargent & Lundy, Chicago, IL (United States)

1996-03-01T23:59:59.000Z

52

Substation grounding programs  

SciTech Connect

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 2, is a users manual and an installation and validation manual for the computer program SMECC (Substation Maximum Earth Current Computation Program). This program analyzes the electric current distribution among grounded structures inside and outside a substation for different fault conditions. The fault conditions are automatically selected by the program, or they may be specified by the user, or both. The fault condition resulting in maximum substation earth current is identified and reported. Data requirements for this program are: ground impedance, transformer data, transmission line data, transmission line grounding impedances, etc. The program provides four types of standard outputs: (1) a report of voltages and current flow in the unfaulted system, (2) a brief report of the maximum ground potential rise (worst fault condition), (3) a summary report of all fault conditions which have been analyzed by the program, and (4) a detailed report of voltages and current flow for a selected set of fault conditions.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

53

Substation flood protection: A case study  

SciTech Connect

On July 18, 1996, the City of Naperville, Illinois encountered a substantial storm event ranging from nine to fourteen inches of rainfall across town in less than twelve hours, with the majority falling over a four-hour period. The watershed containing the City`s Westside substation encountered the most significant rainfall totals, resulting in a flood crest in the substation area of approximately thirteen inches of water. The station is a 138 kV substation, and the flooding of this station caused a power loss to approximately 60% of the City`s customers for more than eight hours. The water level posed no threat to yard equipment, however, within the substation control building, flood water shorted out control circuits and damaged transmission line relay systems. Crews worked round-the-clock for most of a week to return all transmission lines and transformers to normal service. The 15 kV switchgear ultimately had to be replaced due to recurring control circuit problems. Once the station was restored and the cleanup efforts underway, the City embarked on an evaluation to determine what condition or conditions allowed the flooding to occur, and what could be done in the future to avoid this problem to ensure that the customers of Naperville would not experience another service outage of this magnitude due to flooding.

Gacek, D.B. [City of Naperville, IL (United States); McGovern, L.L. [Burns and McDonnell, Westmont, IL (United States)

1999-11-01T23:59:59.000Z

54

Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Facility: Building 382 Rev. 1, 02/11/00 Facility: Building 382 Rev. 1, 02/11/00 Training: (1) ESH114 Lockout/Tagout ASD125 APS LOTO ESH371 Electrical Safety - General ESH195 PPE ESH141 Hand and Power Tools (2) ESH707 Accelerator Worker ESH738 GERT (3) ESH196 Hazard Communication ESH376 or 456 Chemical Waste (4) ASDSF6 (5) ESH170 OSHA Lead Standard ESH196 Hazard Communication ESH195 PPE ESH141 Hand and Power Tools (6) ESH195 PPE ESH141 Hand and Power Tools (7) Informal OJT (8) Formal OJT Management Tools: (A) ANL-E ESH Manual SMART (B) APS-SAD APS-CO (C) Waste Handling Procedure Manual Equipment Hazards Engineered Controls Electrical Safety Training References Electrical Safety Procedures Mechanical Safety Training References Mechanical

55

Reliability centered maintenance for substation equipment  

SciTech Connect

This paper is a collection of training materials on the principles and implementation of reliability centered maintenance. The main areas discussed in this presentation are organized as follows: RCM principles and concepts; RCM tools, resources and methods; overview of the RCM process; example RCM application; living PM program; RCM implementation experience.

NONE

1996-08-01T23:59:59.000Z

56

Microsoft Word - CX_DeMoss_Substation_Expansion_130531  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alaric Hsu Alaric Hsu Project Manager - TEP-CSB-2 Proposed Action: De Moss Substation Expansion Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions and modifications to transmission facilities Location: Sherman County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to expand its De Moss Substation yard located in Sherman County, Oregon. The expansion is necessary to install additional reactors that would provide the necessary reactive support to address the extreme high voltage at De Moss Substation resulting from the loss of the Big Eddy - DeMoss transmission line during winter peak conditions. The equipment at De Moss Substation is currently sustaining voltage

57

APS team works smarter, cuts substation construction costs by 36%  

SciTech Connect

An aggressive, cost-cutting, team of T D employees at Arizona Public Service Co (APS) is building a new distribution substation in Phoenix for less than half the original cost that APS planners had calculated for the project's land, labor and materials. Scheduled for service in June of this year, APS analysts had originally projected land, labor and materials costs for the 20-MVA Bell substation at nearly $1.7-million-not including major equipment such as transformers, circuit breakers, and switches. However, after studying the project, an empowered APS crew was able to slash 36% off the original estimate-more than $610,000. What's more, APS spokesmen say that its new approach to substation construction and design has given its engineers and construction crews a laundry list of additional ideas to try out on future substation ventures. 4 figs., 1 tab.

Not Available

1993-05-01T23:59:59.000Z

58

Substation grounding programs  

SciTech Connect

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 3, is a users manual and an installation and validation manual for the computer program SGSYS (Substation Grounding SYStem Analysis Program). This program analyzes the substation ground field given the total electric current injected into the ground field and the design of the grounding system. Standard outputs of the program are (1) total ground resistance, (2) step voltage, (3) touch voltage, (4) voltages on a grid of points, (5) voltage profile along straight lines, (6) transfer voltages, (7) ground potential rise, (8) body currents, (9) step voltage profile along straight lines, and (10) touch voltage profile along straight lines. This program can be utilized in an interactive or batch mode. In the interactive mode, the user defines the grounding system geometry, soil parameters, and output requests interactively, with the use of a user friendly conversational program. The users manual describes data requirements and data preparation procedures. An appendix provides forms which facilitate data collection procedures. The installation and validation manual describes the computer files which make up the program SGSYS and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

59

INSITE: An emerging standard for substation monitoring  

SciTech Connect

The functions of the INSITE Substation Apparatus Monitoring System can be broken into two, somewhat arbitrary categories. (1) Data acquisition, storage and communications, (2) Data analysis and apparatus condition assessment. We have defined the first set of functions as comprising the {open_quotes}platform{close_quotes}, the second as an {open_quotes}application{close_quotes}. We have made the distinction to encourage users to contemplate other possible {open_quotes}applications{close_quotes} which may be implemented using the platform. The intent of this paper is to describe in detail the platform functions. The requirements for the platform derive from several overall goals of a substation apparatus monitoring system: (1) Comprehensive: The ability to monitor all important types of substation apparatus, combined with all the tools - the sensors, the Data Acquisition Unit, and the analysis and communications software - for an on-line, real-time condition assessment of your equipment, with critical information at everyone`s fingertips. (2) Dependable: Built-in self-diagnosis that assures optimum system performance. (3) Reliable: From an extremely hot to extremely cold environment, capable of functioning reliably in electrically noisy substations. (4) Expandable: Easily upgradable to accommodate additional sensors available today and any new types developed tomorrow - as well as new software, for monitoring other equipment down the road. (5) Open: The ability to accept non-Doble supplied sensors - with future capability for integrating RS-232-compatible intelligent sensors. (6) Complementary: Compatibility with existing DTA technology, for example, making comparison of both out-of-service and in-service data possible. (7) Easy-to-Use: A Windows application with user-friendly pull-down menus, simple icons and buttons, and dialog sessions that can be mastered easily. On-line Help is also available. (8) Lowest possible cost.

Woodward, R.C. [Doble Engineering Company, Watertown, MA (United States)

1996-03-01T23:59:59.000Z

60

Requirements Specification for and Evaluation of an Automated Substation Monitoring System  

E-Print Network (OSTI)

, without to much disruption in power supply to the users, Equipment Condition Monitoring (ECM) has to beRequirements Specification for and Evaluation of an Automated Substation Monitoring System Mladen for the Automated Analysis Substation System (AASS) implemented at Texas A&M University, aimed at monitoring

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

500-kV Central Ferry Substation ...  

NLE Websites -- All DOE Office Websites (Extended Search)

Central Ferry Substation in Garfield County, Wash., to BPA's 500-kV Lower Monumental Substation in Walla Walla County, Wash. BPA is currently considering two routing...

62

Line Rebuild, Relocation and Substation Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

Upgrade Palisades-Goshen Rebuild Wind Projects Line Rebuild, Relocation and Substation Projects BPA has identified several critical rebuild and substation projects...

63

CYBER SECURITY OF SUBSTATION AUTOMATION SYSTEMS .  

E-Print Network (OSTI)

??Cyber intrusions into substations of a power grid are a source of vulnerability since most substations are unmanned and with limited protection of the cyber… (more)

[No author

2014-01-01T23:59:59.000Z

64

Substation grounding programs  

SciTech Connect

The five volume report comprises the user manual, installation, and validation manual and an applications guide for the SGA (Substation Grounding Analysis) software package. SGA consists of four computer programs: (1) SOMIP, (2) SMECC, (3) SGSYS, and (4) TGRND. The first three programs provide a comprehensive analysis tool for the design of substation grounding systems to meet safety standards. The fourth program, TGRND, provides a state of the art analysis tool for computing transient ground potential rise and ground system impedance. This part of the report, Volume 1, is a users manual and an installation and validation manual for the computer program SOMIP (SOil Measurement Interpretation Program). This program computes the best estimate of the parameters of a two layer soil model from usual soil resistivity measurements. Four pin or three pin soil measurements can be accommodated. In addition, it provides error bounds on the soil parameters for a given confidence level. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program SOMIP and provides two test cases for validation purposes. 4 refs.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). School of Electrical Engineering)

1992-05-01T23:59:59.000Z

65

Design of the Wireless Temperature Measurement Alarming System in the High-Voltage Transformer Substation  

Science Journals Connector (OSTI)

Due to electric power overload and equipment aging, fire and explosion occur at transmission circuitry joints in high-voltage transformer substation caused by high temperatures accumulated at these...

Qiang Gao; Hongli Wang; Huaxiang Wang

2008-01-01T23:59:59.000Z

66

Near field coupling to shielded cable due to switching operation in substation  

Science Journals Connector (OSTI)

It is vital to study the electromagnetic coupling to shielded cable for improving electromagnetic antiinterference ability of secondary equipment in a substation. As a hybrid of method of moment ... shielded cabl...

Lei Qi; Xiang Cui

2008-09-01T23:59:59.000Z

67

Application Analysis on EPON Technology Applied in Communication System of Smart Substation  

Science Journals Connector (OSTI)

This paper pointed out the problem that cost of communication equipments such as industrial Ethernet switch used to build the communication system of smart substation is excessively high, Analyzed the characteri...

Wei Yong; Xu Wei-guo; Zhang Yong-li…

2012-01-01T23:59:59.000Z

68

Earth-Fault Relay Equipment  

Science Journals Connector (OSTI)

... proving the reliability of the equipment. By Observing the operation of the relays at each substation with faults at selected points, the complete scheme can be put into operation with ...

1944-04-15T23:59:59.000Z

69

Reduction of interference on substation low voltage wiring  

SciTech Connect

This paper describes test results and mitigation methods of electromagnetic interference (EMI) on control and low voltage circuits in substations caused by air disconnect switch operation. The tests are focused on a comparison between unshielded and shielded circuits from capacitively coupled voltage transformers (CCVT) and other equipment circuits in the vicinity. New test data are presented comparing unshielded and shielded cables and transient currents on all connections to the CCVT including the pedestal and ground strap. The paper gives a practical and understandable explanation of the causes of EMI in substations and how shielded cable and parallel ground conductors reduce interference. Design guidelines are listed in the Conclusion.

Gavazza, R.J. [Pacific Gas and Electric Co., San Francisco, CA (United States)] [Pacific Gas and Electric Co., San Francisco, CA (United States); Wiggins, C.M. [Carl M. Wiggins and Associates, Friendswood, TX (United States)] [Carl M. Wiggins and Associates, Friendswood, TX (United States)

1996-07-01T23:59:59.000Z

70

Microsoft Word - CX-SnohomishPUD Equipment Purchase_140521  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

to public health or the environment. Table 1. Equipment to be purchased from Public Utility District No. 1 of Snohomish County Facility Name Asset Murray Substation Bay 24:...

71

Transient performance of substation structures and associated grounding systems  

SciTech Connect

When lightning strikes an electric substation, large currents generated by the stroke flow in the above ground structures and grounding system and dissipate in the soil. The electromagnetic fields generated by such high currents may cause damage to equipment and may be dangerous to personnel working nearby. In this paper, the frequency and time domain performance of a substation subjected to a lightning strike is described and discussed. The computed scalar potentials, electric fields, and magnetic fields are presented graphically as a function of spatial coordinates, as a function of time and as a function of both. Two cases are considered. The first case examines the substation grounding system only, while the second case includes an above-ground structure as well. It is believed that the results of the second case have not been published before. A double exponential lightning surge current is injected at one corner of the substation. The response of the grounding system to the frequency domain electromagnetic spectrum of this signal is computed by a frequency domain electromagnetic field analysis software package. The temporal and spatial distributions of the electromagnetic fields inside and near the substation are obtained by an inverse Fourier transformation of all these responses. The presence of a soil with an arbitrary resistivity and permittivity is accurately taken into account. The analysis sheds some new light on the understanding of the effects which take place at the higher frequencies.

Dawalibi, F.P.; Xiong, W.; Ma, J. [Safe Engineering Services and Technologies Ltd., Montreal, Quebec (Canada)] [Safe Engineering Services and Technologies Ltd., Montreal, Quebec (Canada)

1995-05-01T23:59:59.000Z

72

Application and field experience of a digital substation switch  

SciTech Connect

There has been an increase in the use of solid-state, microprocessor-based relays, fault recorders, meters, and programmable controllers; in transmission and distribution substations. These devices can be remotely interrogated or programmed, and can send reports back to a host computer through their RS-232 communications ports. These devices use a wide variety of communications software and protocols. Because these devices can be located in the substation yard, induced surges and voltages can be present on the communication lines. This can impair the ability to communicate over RS-232 lines, and even cause equipment damage. In addition. the distance from the control house to the substation yard can limit the use of standard RS-232 protocol. For greater system economy, several devices must use the same communications channel. This requires a means of reliably connecting several devices to the incoming and outgoing communications circuits. This paper describes a digital substation switch (DSS) that was designed for this application, and its initial installation and field experience at Savannah Electric. The DSS connects various meters, transmission relays, and distribution relays to PCs in remote locations through a voice-grade telephone circuit. In this application, the DSS uses a fiber loop to communicate with the devices in the substation yard.

Spain, R.; Fodero, K.

1994-12-31T23:59:59.000Z

73

Scoping study: Substation design workstation  

SciTech Connect

This project conducted a survey, consisting of a written questionaire, a workshop, and site visits to determine what facets of substation engineering would benefit from incorporation into a workstation environment. Based on the needs expressed by the respondents, a program for the staged development of a Substation Workstation is recommended. Six analytical function modules for assisting in substation engineering were identified for potential inclusion in the workstation: Initial Planning Activities; Physical Plant Design; Analytical Functions; Civil/Structural Design; Environmental Design; and Project Management. The initial release of the Substation Workstation is recommended to include the workstation environment (including MENTOR -- a concept for on-line help, tutorials, notepad, a minor spreadsheet, and interfaces to other regular desktop functions) and portions of the first three functional modules listed above. Recommendations for progress beyond this first release of the workstation included the development of additional capabilities within the initial functional modules, as well as the development of the remaining modules. An overlap exists between the analytical requirements for this workstation and those already included in the EPRI TLWorkstation and the ICWorkstation. In some cases, elements of these other workstations are also suggested for incorporation into the Substation Workstation (such as the foundation analyses from the TLWorkstation), and in others, an assimilation of the other workstation into the Substation Workstation is recommended (as with the ICWorkstation). Estimated resources for implementing the recommended program, including both costs and development time, are also provided.

Mauser, S.F. (Power Technologies, Inc., Wilmerding, PA (United States)); Conroy, M.W. (Sargent and Lundy, Chicago, IL (United States)); Singh, N.M. (Power Computing, Dallas, TX (United States))

1993-03-01T23:59:59.000Z

74

Substation grounding programs  

SciTech Connect

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. It can be used to compute transient ground potential rise due to lightning or switching, and the ground impedance (i.e. resistance and reactance) at specified frequencies. This report, Volume 4, is a users manual and an installation and validation manual for the computer program TGRND (Transient GRouNDing System Analysis Program). This program computes transient ground potential rise resulting from lightning, switching, or other transient electric currents injected to a grounding system. The program also computes the impedance (i.e. resistance and reactance) of a grounding system as a function of frequency. This program can be utilized in an interactive or batch mode. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program TGRND and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

75

Variable Voltage Substation Electric Fire and Emergency Response  

Energy.gov (U.S. Department of Energy (DOE))

Variable Voltage Substation Electric Fire and Emergency Response My question is from an emergency response perspective. You stated that it took ~ ½ for electricians to de-energize the electrical components before firefighters were allowed in to fight the fire. This delay causes more damage to equipment and potential propagation of the fire. Is there not a “master” breaker or switch? You’ve brought up a very good point. It gave me a good opportunity to discuss this with our Facilities Department and get a better understanding of the infrastructure upgrade plans. The direct answer to your question is “Yes, but…” Yes, there are “master” breakers and switches, but we can’t control them remotely. SLAC’s AC electrical distribution system at present is manual breakers – we have not installed the infrastructure to remotely control them (except see below). We recently underwent an upgrade to our Master Substation that will allow us to remotely control some high voltage breakers in the future, but we aren’t there yet. We do recognize the value in having this capability (and more importantly, our vulnerability in NOT having it), and have begun the preliminary planning to make this happen. One issue were are working on is cyber security for the power distribution networked infrastructure. Before we install the capability to remotely control the main electrical breakers, we are planning the infrastructure with our Information Technologies organization to ensure we have a robust secure network that is protected from unauthorized access. Once the cyber security issues are addressed and funded, we’re probably 5-10 years out from having remote operation capability due to limited resources to fund and install the infrastructure. Having said the above, we do have the capability of remotely opening the VVS Secondary Main Breakers – the ones that send power to the modulator distribution breakers - from our control room. Those breakers are integral parts of our safety systems in that interlock violation causes the breakers to open and remove power to the klystrons. But everything else is manual only. That remote operation capability would not have helped us in this case, as the VVS Secondary Main Breaker was the one that fried. We needed to open the breaker upstream of the VVS. Thanks for your interest. Let me know if I can provide further information.

76

BE 400/18 kV Substation Renovation Project  

E-Print Network (OSTI)

The 400/18 kV SPS main substation was designed for the 400 GeV SPS project and was commissioned in 1974. It has been upgraded several times to form the present 400/66/18 kV SPS and LEP transmission power comprising 490 MVA and 240 MVAR installed power. The beginning of the LHC project and the obsolescence of the main elements, and consequently limited reliability, made it necessary to begin a complete renovation program. The new configuration of the substation will integrate the new compensator of reactive power efficiently into the 18 kV pulsed network. In this way the new compensator will facilitate the functioning of the pulsed network with the new loads and it will improve the performance of the electrical substation. The renovation program consists in a global reorganisation of the substation, with the total replacement of the 18 kV power equipment, a set up of new control and protection systems for the 18 kV and 400 kV section and the reconditioning of all the 400 kV equipment.

Vairo, Antonio

2001-01-01T23:59:59.000Z

77

Reliability centered maintenance (RCM) for substations project overview  

SciTech Connect

An EPRI Tailored Collaboration project establishing guidelines and tools for implementing Reliability Centered Maintenance (RCM) in substations is nearing completion and final results are being presented at this Substation RCM Conference. The ultimate goal of this RCM project is to help utilities slash substation operations and maintenance costs by optimizing equipment maintenance intervals. Preventive maintenance (PM) programs typically have been developed on a component-by-component basis, relying heavily on equipment vendors` maintenance recommendations. RCM is a logical alternative to traditional PM programs. It is intelligent, common sense maintenance that is function-based rather than component-based. First developed by the airline industry in the 1960s and further developed and applied to the nuclear industry by EPRI in the 1980s, RCM ranks the importance of each function of a system, calculates the impact the loss of the function would have on the overall system, and drives the design of appropriate maintenance tasks for each function. The nuclear industry reaped savings of at least 25% by adopting RCM, and one utility that tried this approach for substation maintenance reported savings of 13% in one year.

Lyons, P.F.

1996-08-01T23:59:59.000Z

78

Characterization of ferroresonant modes in HV substation with CB grading capacitors  

Science Journals Connector (OSTI)

This paper reports a ferroresonant experience involving inductive voltage transformers (VT's) in a 400 kV substation equipped with circuit breaker grading capacitors. Field measurements are presented and compared with ATP/EMTP simulation results, showing very good agreement. A parametric analysis has been performed to investigate the effect of the substation capacitance on the occurrence of ferroresonance. Fundamental frequency and sub-harmonic ferroresonant modes have been identified and compiled in a bifurcation diagram. The methodology presented can be used to create risk maps of avoidable switching operations or substation configurations.

M. Val Escudero; I. Dudurych; M.A. Redfern

2007-01-01T23:59:59.000Z

79

Optimal location and sizing of HV/MV substations in uncertainty load environment using genetic algorithm  

Science Journals Connector (OSTI)

In this paper a novel approach for optimal location, sizing and determining the service areas of HV/MV substations in a long-range planning period using pseudodynamic methodology is presented. Costs of equipment, areas, cables in MV side and power loss are considered in cost function. Uncertainty in loads is modeled using LR fuzzy numbers in load points. For optimization procedure, genetic algorithm with a new coding is used. Load points splitting in each area between substations and infeasibility solutions are considered in search procedure. Based on this, a software was developed and integrated into an optimization tool for substation allocation. The software was applied in many cases with satisfactory results.

M.R Haghifam; M Shahabi

2002-01-01T23:59:59.000Z

80

Ashland Area Support Substation Project  

SciTech Connect

The Bonneville Power Administration (BPA) provides wholesale electric service to the City of Ashland (the City) by transferring power over Pacific Power Light Company's (PP L) 115-kilovolt (kV) transmission lines and through PP L's Ashland and Oak Knoll Substations. The City distributes power over a 12.5-kV system which is heavily loaded during winter peak periods and which has reached the limit of its ability to serve peak loads in a reliable manner. Peak loads under normal winter conditions have exceeded the ratings of the transformers at both the Ashland and Oak Knoll Substations. In 1989, the City modified its distribution system at the request of PP L to allow transfer of three megawatts (MW's) of electric power from the overloaded Ashland Substation to the Oak Knoll Substation. In cooperation with PP L, BPA installed a temporary 6-8 megavolt-amp (MVA) 115-12.5-kV transformer for this purpose. This additional transformer, however, is only a temporary remedy. BPA needs to provide additional, reliable long-term service to the Ashland area through additional transformation in order to keep similar power failures from occurring during upcoming winters in the Ashland area. The temporary installation of another 20-MVA mobile transformer at the Ashland Substation and additional load curtailment are currently being studied to provide for sustained electrical service by the peak winter period 1992. Two overall electrical plans-of-service are described and evaluated in this report. One of them is proposed for action. Within that proposed plan-of-service are location options for the substation. Note that descriptions of actions that may be taken by the City of Ashland are based on information provided by them.

Not Available

1992-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Microcomputer Applications in Power System Substation Automation  

Science Journals Connector (OSTI)

The object of this chapter is to describe power system applications of microcomputers, particularly in the area of power substation automation.The major functions required in substation automation are reviewed an...

C. T. Nguyen; R. Grondin; A. St-Jacques…

1983-01-01T23:59:59.000Z

82

Categorical Exclusion for Pinnacle Peak Substation PCB contaminated Electrical  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Categorical Exclusion for Pinnacle Peak Substation PCB contaminated Electrical Equipment Removal Project located north of Phoenix, Maricopa County, Arizona RECORD OF CATEGORICAL EXCLUSION DETERMINATION A. Proposed Action: Western proposes drain and dispose of PCB contaminated oil from two bushings, and decontaminate one· bushing and rack, break apart PCB contaminated concrete and excavate PCB contaminated soil at Pinnacle Peak Substation. Western will be use existing access roads and vehicles such as cranes, backhoes, dozers, bucket trucks, crew trucks and pickup trucks to bring personnel and equipment to the work area. This work is necessary to maintain the safety and reliability of the bulk electrical system. The project is located in Maricopa County, Arizona. The attached map shows the

83

East Grangeville Substation : Environmental Assessment.  

SciTech Connect

BPA proposes to build a 6/8 MVA, 115/13.8-kV substation about 0.7 mile (1.2 km) east of Grangeville, Idaho. BPA's substation yard would comprise an area of 70 by 72 feet (21 by 22 m) containing a 115/13.8-kV transformer. Energization for the substation is scheduled for September 1983. In connected actions the Co-op would build a 13.8-kV switching station and a 13.8/34.5-kV step-up station. The Co-op would require an area of 100 by 55 feet (31 by 17 m) in addition to the BPA yard. The total area needed for the combined BPA/Co-op substation would be approximately 170 by 127 feet (52 by 40 m) or one-half of an acre (0.20 ha). The Co-op would also build two 13.8-kV feeders and one 34.5-kV feeder underground south of the substation to overhead distribution lines along State Highway 13 with space for one future feeder. Another 13.8-kV feeder would exit the substation underground and loop around to the north to reconnect to the existing 13.8-kV overhead line. TWWP would build a tapline from their Grangeville-Kamiah-Nez Perce (Grangeville-Nez Perce No. 2) 115-kV transmission line to the substation. This line would be approximately 0.75 mile (1.2 km) long and would consist of single wood pole structures built on the route of an existing Co-op distribution line. The new and existing lines would use the same poles. A temporary access road would be built for 0.25 mile (0.4 km). The remaining 0.5 mile (0.8 km) section would be adjacent to a county road and would not require an access road. Two sites were identified as meeting the technical requirements. Site 2 is recommended.

United States. Bonneville Power Administration.

1983-03-01T23:59:59.000Z

84

Microsoft Word - CX-SnoKingSubstationExpansionFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Michael Marleau Michael Marleau Project Manager - TEP-TPP-1 Proposed Action: Sno-King Substation Expansion Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): Appendix B4.11 Electric power substations and interconnection facilities Location: Bothell, Snohomish County, WA Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to expand its Sno-King Substation's fenced electrical yard by approximately 0.2 acres to accommodate new equipment. The substation expansion is necessary to make room for the addition of a back-up 500/230-kV power transformer, which BPA can energize in the event of a primary transformer failure. The additional transformer will increase the safety and reliability of the system.

85

The Simulation Analysis of Fire Feature on Underground Substation  

Science Journals Connector (OSTI)

Underground transformer substations constructed with non-dwelling buildings have a ... out simulation analysis of fire feature on underground substation. The corresponding fire protection strategy is also...

Xin Han; Xie He; Beihua Cong

2012-01-01T23:59:59.000Z

86

Reliability Evaluation of Substations Subject to Protection Failures:.  

E-Print Network (OSTI)

??Reliability evaluation of power system substations is of significant importance when performing asset management. Most of the studies about substation reliability only focus on the… (more)

Wang, F.

2012-01-01T23:59:59.000Z

87

Substation bus arrangement performance analysis program and metrics.  

E-Print Network (OSTI)

??During preliminary substation design, only minimal information is available to the designer. Substation bus arrangements have been defined in textbooks for their advantages and disadvantages.… (more)

Oneal, Trevor Martin

2011-01-01T23:59:59.000Z

88

Distance and overcurrent protection of feeders at distribution substation.  

E-Print Network (OSTI)

??The ???Distance and Overcurrent Protection of Feeders at Distribution Substation??? report will discuss protection of distribution feeders at a substation. The paper will discuss the… (more)

Chedid, Youssef Pierre

2014-01-01T23:59:59.000Z

89

Substation Topology Analysis Based on Improved Tracking Algorithm  

Science Journals Connector (OSTI)

The substation network topology analysis is an important part ... simulation results validate that the proposed algorithm for substation network topology analysis is easy to be...

Shi Jianlei; Zhang Xuan; Zhao Qiang…

2014-01-01T23:59:59.000Z

90

Advanced communication system in substation for integrated protection  

Science Journals Connector (OSTI)

This paper proposes an advanced substation integrated protection communication system based on the ... . The integrated protection communication system within a substation comprises a number of major components s...

Jinghan He ???; Yingli Ren ???; Zhiqian Bo ???…

2008-04-01T23:59:59.000Z

91

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, Colorado EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project,...

92

HV Substation Earthing Design for Mines  

E-Print Network (OSTI)

Abstract:-High Voltage (HV) substation forms important assets for the mining industries. The existences of these substations necessitate earthing design to ensure safety compliance to the mine regulations. The HV system within the mines is consisted of multiple substations which are connected throughout and underground cable. These substations provide the load with the required electrical power to perform its tasks. This paper endeavours to provide information in regards to the different types of connections between the load and the substations (TT, TN and IT Systems). Furthermore, the earthing arrangements under different connection were assessed. A case study is addressed to show the different earthing arrangements under different connection systems Keywords:- Earth Grid, EPR, Fault Current, High Voltage, Mines, TN and TT systems I.

unknown authors

93

Substation automation -- a ``bottoms up`` approach  

SciTech Connect

The proliferation of multi-purpose intelligent electronic devices in substations brought the availability of abundant and often overlapping data at the substation. This data can be used for improving the operation and maintenance of the substations and the entire power system. The objective of substation automation is to use technology to gather, consolidate and utilize this data for increasing the efficiency of power system operation and maintenance. Often automation functions are developed and offered around the capabilities of the preferred hardware and software of the integrator. Emphasis is placed on hardware, software and communication protocols rather than need, methodology and application. This can result in over-automation with complex, expensive and ineffective systems, or under-automation that fails to achieve the user`s objectives. The objective is to select appropriate hardware, software and methodology to build the most cost effective system to get the desired results. This paper describes steps to ensure the successful implementation of substation automation.

Thomas, J. [General Electric, Malvern, PA (United States)

1996-10-01T23:59:59.000Z

94

substation  

Science Journals Connector (OSTI)

This one-of-a-kind reference is unmatched in the breadth and scope of its coverage and serves as the primary reference for students and professionals in computer science and communications. The Dictionary feat...

2001-01-01T23:59:59.000Z

95

Substation reliability -- Practical application and system approach  

SciTech Connect

Practical application of reliability analysis was made for the comparison of alternate line and bus arrangements of a future transmission substation with potential savings of up to $3.6 M. The paper describes how both the substation and the power system were simulated by using computer programs STAREL and COMREL. It presents the method used to obtain the most accurate estimates for the outage data of the system components. Finally, it expresses the results with simple reliability indices which can be meaningful for management. The results of the study show the need to include the reliability of the transmission system in a substation reliability evaluation.

Save, P. [Southern California Edison Co., Rosemead, CA (United States)] [Southern California Edison Co., Rosemead, CA (United States)

1995-02-01T23:59:59.000Z

96

Substation reliability -- Practical application and system approach  

SciTech Connect

Practical application of reliability analysis was made for the comparison of alternate line and bus arrangements of a future transmission substation with potential savings of up to 53.6 M. The paper describes how both the substation and the power system were simulated by using computer programs STAREL and COMREL. It presents the method used to obtain the most accurate estimates for the outage data of the system components. Finally, it expresses the results with simple reliability indices which can be meaningful for management. The results of the study show the need to include the reliability of the transmission system in a substation reliability evaluation.

Save, P. [Southern California Edison Co., Rosemead, CA (United States)

1994-12-31T23:59:59.000Z

97

Analysis on heat loss characteristics of a 10 kV HTS power substation  

Science Journals Connector (OSTI)

Abstract A 10 kV High Temperature Superconducting power substation (10 kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10 kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10 kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

Yuping Teng; Shaotao Dai; Naihao Song; Jingye Zhang; Zhiyuan Gao; Zhiqin Zhu; Weiwei Zhou; Zhourong Wei; Liangzhen Lin; Liye Xiao

2014-01-01T23:59:59.000Z

98

Experimental adoption of RCM in EDF substations  

SciTech Connect

EDF, after testing Reliability Centered Maintenance (RCM) on systems used in nuclear power plants, has now successfully extended RCM to all of its nuclear power plants. In the light of this experience, EDF has committed itself to a pilot study on a line bay of a 400 kV substation in 1992. The RCM method as applied benefited from EDF`s policy of maintenance, introduced five years ago on all substations, which has enhanced prospects of reliability. The original feature in the selection of maintenance tasks was that it brought into play two criteria for failure assessment - frequency and seriousness - and two criteria for maintenance task selection - efficiency and facility. The final outcome of RCM as applied to substation maintenance is to categorize maintenance tasks into: (1) essential maintenance tasks, (2) optional tasks, depending on the type and location of the substation, as well as on factors relating to local management of maintenance policy, and (3) unnecessary tasks.

Heroin, G.; Aupied, J. [Electricite de France, Clarmart (France); Sanchis, G. [Direction EDF Production Transport, Courbevoie (France)

1996-08-01T23:59:59.000Z

99

Network Security for Substation Automation Systems  

Science Journals Connector (OSTI)

The protection of critical infrastructure against electronic and communication network based attacks becomes more and more important. This work investigates the threat of network-based attacks on substations, the...

Martin Naedele; Dacfey Dzung…

2001-01-01T23:59:59.000Z

100

Characterization of electromagnetic transients in power substations  

E-Print Network (OSTI)

CHARACTERIZATION OF ELECTROMAGNETIC TRANSIENTS IN POWER SUBSTATIONS A Thesis by WILLIAM CHESTER CiOERS, JR. Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree of MASTER... OF SCIENCE December 1980 Major Subject: Electrical Engineering CHARACTERIZATION OF ELECTROMAGNETIC TRANSIENTS IN POWER SUBSTATIONS A Thesis by WILLIAM CHESTER GOERS, JR. Approved as to style and content by: Dr. B. Don Russell (Chairman of Committee...

Goers, William Chester

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Microsoft Word - Cascade Networks Allston Substation LURR CX.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

15, 2011 15, 2011 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearence Memorandum Harold Grappe - TELP-TPP-3 Proposed Action: Cascade Networks, Inc. LURR at Allston Substation Budget Information: Work Order # 00275035 Task 03 Categorical Exclusions Applied (from Subpart D, 10 C.F.R. Part 1021: B1.7 "Acquisition, installation, operation, and removal of communication systems, data processing equipment, and similar electronic equipment." B4.7 "Adding fiber optic cable to transmission structures..." Location: Section 10, Township 7 North, Range 3 West of the Delena Quadrangle located in Columbia County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to grant Cascade Networks, Inc. permission to

102

Ashland Area Support Substation Project : Environmental Assessment.  

SciTech Connect

The Bonneville Power Administration (BPA) provides wholesale electric service to the City of Ashland (the City) by transferring power over Pacific Power & Light Company`s (PP&L) 115-kilovolt (kV) transmission lines and through PP&L`s Ashland and Oak Knoll Substations. The City distributes power over a 12.5-kV system which is heavily loaded during winter peak periods and which has reached the limit of its ability to serve peak loads in a reliable manner. Peak loads under normal winter conditions have exceeded the ratings of the transformers at both the Ashland and Oak Knoll Substations. In 1989, the City modified its distribution system at the request of PP&L to allow transfer of three megawatts (MW`s) of electric power from the overloaded Ashland Substation to the Oak Knoll Substation. In cooperation with PP&L, BPA installed a temporary 6-8 megavolt-amp (MVA) 115-12.5-kV transformer for this purpose. This additional transformer, however, is only a temporary remedy. BPA needs to provide additional, reliable long-term service to the Ashland area through additional transformation in order to keep similar power failures from occurring during upcoming winters in the Ashland area. The temporary installation of another 20-MVA mobile transformer at the Ashland Substation and additional load curtailment are currently being studied to provide for sustained electrical service by the peak winter period 1992. Two overall electrical plans-of-service are described and evaluated in this report. One of them is proposed for action. Within that proposed plan-of-service are location options for the substation. Note that descriptions of actions that may be taken by the City of Ashland are based on information provided by them.

United States. Bonneville Power Administration.

1992-06-01T23:59:59.000Z

103

Data collecting and processing for substation integration enhancement  

E-Print Network (OSTI)

The issue of substation integration is recognized as a very important one ever since the process of technological development brought a multitude of new computer-based devices and functions into substation operation. During the relatively short time...

Jakovljevic, Sasa

2004-09-30T23:59:59.000Z

104

Design, Simulation, and Analysis of Substation Automation Networks  

E-Print Network (OSTI)

on the Substation Automation Systems (SAS). Substations are nodes in the smart grid infrastructure that help the in transportation of power by connecting the transmission and distribution lines. The SAS applications are con figured to operate with minimal human...

Kembanur Natarajan, Elangovan

2012-07-16T23:59:59.000Z

105

The Study Based on IEC61850 Substation Information System Modeling  

Science Journals Connector (OSTI)

The series of international standards IEC 61850 substation communication networks and systems to provide a ... the power system. This study is the substation automation technology has entered the network developm...

Yu Xian

2013-01-01T23:59:59.000Z

106

The effect of Relay Protection on the Substation Reliability  

Science Journals Connector (OSTI)

This paper presents a model for evaluating the reliability of the substation actions after transmission grid faults. The model ... of different line protection systems by using the substation reliability model is...

Liisa Pottonen; Urho Pulkkinen…

2004-01-01T23:59:59.000Z

107

Planning substation capacity under the single-contingency scenario  

SciTech Connect

Florida Power and Light (FPL) adopts the single contingency emergency policy for its planning of substation capacity. This paper provides an approach to determine the maximum load which a substation can take on under such a policy. The approach consists of two LP models which determine: (1) the maximum substation load capacity, and (2) the reallocation of load when a substation`s demand cannot be met. Both models are formulated under the single-contingency scenario, an issue which had received little attention in the literature. Not only does the explicit treatment of the scenario provide an exact measure of a substation`s load limit, it also raises several important issues which previous works omit. These two models have been applied to the substation network of the Fort Myers District of the State of Florida.

Leung, L.C. [Chinese Univ. of Hong Kong, Shatin (Hong Kong). Decision Sciences and Managerial Economics] [Chinese Univ. of Hong Kong, Shatin (Hong Kong). Decision Sciences and Managerial Economics; Khator, S.K. [Univ. of South Florida, Tampa, FL (United States). Industrial and Management Systems Engineering] [Univ. of South Florida, Tampa, FL (United States). Industrial and Management Systems Engineering; Schnepp, J.C. [Crest Ultrasonics, Trenton, NJ (United States)] [Crest Ultrasonics, Trenton, NJ (United States)

1995-08-01T23:59:59.000Z

108

Security Assessment of Communication Networks for Integrated Substation Automation Systems  

Science Journals Connector (OSTI)

To assess the security of communication networks for integrated substation automation systems, a systematic approach based on ... to communication networks between the control center and substations through the a...

Huisheng Gao; Xuejiao Dai

2011-01-01T23:59:59.000Z

109

HV Substation Overvoltage Computation Taking into Account Frequency Dependent Transients on the Substation Grounding System  

E-Print Network (OSTI)

Abstract-This paper describes methodology for the computation of the electromagnetic transients in the high voltage substations, taking into account transients on the substation grounding system. Simulation technology is based on the system decomposition. Interconnections between different subsystems are done in each time step using Thevenin equivalents. Frequency dependent impedance of grounding conductors is represented by the parallel combination of resistance-inductance branches, to enable simulation in the time domain. Lightning overvoltage computation is performed for one particular 123 kV high voltage substation.

unknown authors

110

Microsoft Word - CX-TaylorFlatsSubstationMeterFY13_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

25, 2013 25, 2013 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Cleareance Memorandum Bob Trisman Electrical Engineer - TEP-CSB-1 Proposed Action: Revenue meter replacement at Franklin County Public Utility District's (PUD) Taylor Flats Substation PP&A Project No: 2608 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Franklin County, Washington. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to remove the existing equipment and replace it with a new JEMSTAR revenue meter within BPA's existing meter rack inside Franklin County PUD's Taylor Flats Substation. No ground disturbance or alteration to the control house would occur.

111

Reliability of substation protection system based on IEC61850  

Science Journals Connector (OSTI)

Although the new technology of protection and automation system of substation based on IEC61850 standard has developed rapidly...

Xiaofu Xiong ???; Jun Yu ? ?; Xiaofang Liu ???…

2008-04-01T23:59:59.000Z

112

Environmental noise of a nuclear power plant and its substations  

Science Journals Connector (OSTI)

In order to fulfill government requirements for construction of a nuclear power plant an environmental noiseimpact as?assessment has been conducted. Ambient noise was measured continuously for 24 hour periods at the plant and substation sites and in the vicinity. Week long surveys were performed in each of the four seasons. A statistical interpretation of construction noise accounts for variability of construction equipment usage its location and range of sound pressure levels. Histograms of construction noise and measured ambient noise are added to obtain the statistical representation of the predicted construction ambient noise. Operational noise of the plant is similarly predicted. The predicted noise contours of both operation and construction noise are formulated on the topographic maps. Meteorologic and topographic effects on the noise data are discussed.

E. E. Dennison; R. E. Maier; J. W. McGaughey; S. P. Ying

1976-01-01T23:59:59.000Z

113

Grounding Analysis in Heterogeneous Soil Models: Application to Underground Substations  

E-Print Network (OSTI)

Grounding Analysis in Heterogeneous Soil Models: Application to Underground Substations Ignasi category includes all step- up and step-down transmission substations, as well as a number of distribution substations indeed. Nevertheless, the current trend in electric power Engineering moves in another direction

Colominas, Ignasi

114

The Substation of the Future: A Feasibility Study  

E-Print Network (OSTI)

The Substation of the Future: A Feasibility Study Final Project Report Power Systems Engineering Research Center Empowering Minds to Engineer the Future Electric Energy System #12;Substation of the Future Engineering Research Center (PSERC) research project T-38 titled "Substation of the Future: A Feasibility

115

Short proofs of the Quantum Substate Theorem National U. Singapore  

E-Print Network (OSTI)

Short proofs of the Quantum Substate Theorem Rahul Jain National U. Singapore Ashwin Nayak U. Waterloo December 30, 2011 Abstract The Quantum Substate Theorem due to Jain, Radhakrishnan, and Sen (2002 a substate of . We present new proofs of this theorem. The resulting statement is optimal up to a constant

Nayak, Ashwin

116

Techniques for Securing Substation Automation Systems David Guidry1  

E-Print Network (OSTI)

Techniques for Securing Substation Automation Systems David Guidry1 , Mike Burmester1 , Xiuwen Liu1 propose techniques for resilient substation automation of power utility systems with security based-90-5 compliant substation automation systems that are resilient. We demonstrate the feasibility of our approach

Burmester, Mike

117

Abstract--Many functions within a substation can be performed more efficiently if all the substation data is collected  

E-Print Network (OSTI)

1 Abstract--Many functions within a substation can be performed more efficiently if all the substation data is collected from and shared among Intelligent Electronic Devices (IEDs). Gathered measurements and apparatus statuses can be processed by (local) substation computer(s). Processing includes

118

Utility programs for substation diagnostics development  

SciTech Connect

This article is a brief overview of the opening remarks of the utility panel. These remarks developed a number of interesting substation diagnostic activities and concepts in which the electric utilities are engaged and outlined the considerations which must accompany development of diagnostic sensors and systems. These area include transformer diagnostics, circuit breaker diagnostics, and testing/cost of diagnostic systems.

NONE

1996-03-01T23:59:59.000Z

119

Microsoft Word - NEPA_CX_Acquisition_of_OTEC_Disconnect_Switch_LaGrand_Substation_05-08-2012.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Kelly Miller Kelly Miller Project Manager - TG-DITT-2 Proposed Action: BPA Acquisition of OTEC Disconnect Switch at the BPA LaGrande Substation Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): Appendix B 1.24 Property Transfer Location: BPA LaGrande Substation, in the City of LaGrande, Union County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to purchase the 230-kilovolt (kV) main bus disconnect switch (MB A-270) that is currently installed and operating within the BPA LaGrande Substation. The disconnect switch is owned by the Oregon Trail Electric Cooperative (OTEC). On October 7, 2011, the manager of engineering for OTEC requested that BPA purchase the disconnect switch. The disconnect switch is the only piece of equipment within

120

Marion Industrial Substation Project : Environmental Assessment.  

SciTech Connect

Consumers Power, Inc. (CPI), proposes to construct a new distribution substation under the existing Bonneville Power Administration (BPA) Albay-Lebanon transmission line near the city of Albany in Linn County, Oregon. BPA is proposing to grant a new Point of Delivery to CPI at this substation. The purpose of the project is to serve the developing industrial needs in the Marion Industrial Park and on the 550 acres of nearby land within CPI's service area that are zoned for residential use. CPI prepared, and the Rural Electrification Administration (REA) has approved a Borrower's Environmental Report (BER) which addresses this action along with several other proposed projects in the CPI service area. Portions of this BER are summarized in this brief EA. BPA is preparing its own EA since Department of Energy National Environmental Policy Act (NEPA) guidelines require additional environmental concerns to be addressed than are required by REA's NEPA guidelines.

United States. Bonneville Power Administration.

1992-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Marion Industrial Substation Project : Environmental Assessment.  

SciTech Connect

Consumers Power, Inc. (CPI), proposes to construct a new distribution substation under the existing Bonneville Power Administration (BPA) Albay-Lebanon transmission line near the city of Albany in Linn County, Oregon. BPA is proposing to grant a new Point of Delivery to CPI at this substation. The purpose of the project is to serve the developing industrial needs in the Marion Industrial Park and on the 550 acres of nearby land within CPI`s service area that are zoned for residential use. CPI prepared, and the Rural Electrification Administration (REA) has approved a Borrower`s Environmental Report (BER) which addresses this action along with several other proposed projects in the CPI service area. Portions of this BER are summarized in this brief EA. BPA is preparing its own EA since Department of Energy National Environmental Policy Act (NEPA) guidelines require additional environmental concerns to be addressed than are required by REA`s NEPA guidelines.

United States. Bonneville Power Administration.

1992-04-01T23:59:59.000Z

122

Short proofs of the Quantum Substate Theorem  

E-Print Network (OSTI)

The Quantum Substate Theorem due to Jain, Radhakrishnan, and Sen (2002) gives us a powerful operational interpretation of relative entropy, in fact, of the observational divergence of two quantum states, a quantity that is related to their relative entropy. Informally, the theorem states that if the observational divergence between two quantum states rho, sigma is small, then there is a quantum state rho' close to rho in trace distance, such that rho' when scaled down by a small factor becomes a substate of sigma. We present new proofs of this theorem. The resulting statement is optimal up to a constant factor in its dependence on observational divergence. In addition, the proofs are both conceptually simpler and significantly shorter than the earlier proof.

Rahul Jain; Ashwin Nayak

2011-03-31T23:59:59.000Z

123

Microsoft Word - CX-BentonCoPUD-FinleySubstationMeterProject_FY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

John Roeder John Roeder Contractor - TEP-CSB-1 Proposed Action: Revenue Meter Replacement at Benton County Public Utility District's (PUD) Finley Substation PP&A Project No: 2594 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Benton County, Washington Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace an existing JEM1 revenue meter with a new JEMStar revenue meter within an existing meter rack at Benton County PUD's Finley Substation. BPA would own the rack and meter. No ground disturbance or alteration to the meter house would occur. Findings: BPA has determined that the proposed action complies with Section 1021.410 and

124

Categorical Exclusion (CX) Determination Proposed Action: Havre Substation, Stage 03.  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Havre Substation, Stage 03. Havre Substation, Stage 03. Description of Proposed Action: The Western Area Power Administration (Western) is proposing to expand the Havre Substation approximately 150 ft to the north to accommodate a new delivery service from the newly built Herron Substation by Hill County. The expansion also converts the existing 115-kV single bus into a ring bus which will improve reliability. Western is also expanding the yard to the east to accommodate the replacement of the existing control building and control boards. Number and Title of Categorical Exclusions Being Applied: 10 CFR 1021.410 Subpart D, Appendix B, B4.11: Construction of electric power substations .. . or modification of existing substations and support facilities . Regulatory Requirements for CX Determination: The DOE Guidelines for Compliance with

125

Modeling and Simulating Blast Effects on Electric Substations  

SciTech Connect

A software simulation tool was developed at the Idaho National Laboratory to estimate the fragility of electric substation components subject to an explosive blast. Damage caused by explosively driven fragments on a generic electric substation was estimated by using a ray-tracing technique to track and tabulate fragment impacts and penetrations of substation components. This technique is based on methods used for assessing vulnerability of military aircraft and ground vehicles to explosive blasts. An open-source rendering and ray-trace engine was used for geometric modeling and interactions between fragments and substation components. Semi-empirical material interactions models were used to calculate blast parameters and simulate high-velocity material interactions between explosively driven fragments and substation components. Finally, a Monte Carlo simulation was added to model the random nature of fragment generation allowing a skilled analyst to predict failure probabilities of substation components.

Lyle G. Roybal; Robert F. Jeffers; Kent E. McGillivary; Tony D. Paul; Ryan Jacobson

2009-05-01T23:59:59.000Z

126

Report of Experiments at Substation No. 11, Nacogdoches, Texas.  

E-Print Network (OSTI)

XAS AGRICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BiZZELL. President BULLETIN NO. 254 - NOVEMBER, 19 19 - -- REPORT OF EXPERIMENTS AT SUBSTATION NO. 1 1, NACOGDOCHES, TEXAS - $ B. YOUNGBLOOD, DIRECTOR... of veterinkj ~edkine. A: & M. College of Texas. **In cooperation with the United States Department of Agriculture. REPORT OF EXPERIMENTS AT SUBSTATION NO. 11, NACOGDOCHES, TEXAS. The substation at Nacogdoches is located two and three-fourths iliiles north...

McNess, George Thomas

1919-01-01T23:59:59.000Z

127

Report of Experiments at Substation No. 4, Beaumont, Texas.  

E-Print Network (OSTI)

**W. T. CARTER, JR., B. S.: Chtej T. M. BUSHNELL. B. S.. Sod Suroegur W. B. FRANCIS. B. S.. Soil Sur~euor bondman I?. G. BREWER, B. S., Assisfanf Animal Hus- bandman -- , Soil Sur&yor SUBSTATIONS No. 1. Beeville, Bee County I. E. COWART. M. S... : 19 a.7mm ary ................................................. 20 [Blank Page in Original Bulletin] REPORT OF EXPERIMENTS, SUBSTATION NO. 4, ' BEAUMONT, TEXAS. Substation No. 4, located six miles west of Beaumont, in one of the largest rice...

Laude, H. H. (Hilmer Henry)

1919-01-01T23:59:59.000Z

128

Knowledge engineering tool for training power-substation operators  

SciTech Connect

Artificial intelligence techniques have been applied to create systems that can give answers for different situations and assistance during the substation switching operation. These techniques have also been used for training purposes. This paper presents a computational package for training power substation operators in the control and corrective actions using expert system techniques. Illustrative examples are presented using a 138-kV CEMIG substation.

Lambert-Torres, G. [Escola Federal de Engenharia de Itajuba (Brazil)] [Escola Federal de Engenharia de Itajuba (Brazil); [Univ. of Waterloo, Ontario (Canada); Costa, C.I.A.; Alves da Silva, A.P. [Escola Federal de Engeharia de Itajuba (Brazil)] [Escola Federal de Engeharia de Itajuba (Brazil); Ribeiro, G.M. [Companhia Energetica de Minas Gerais (Brazil)] [Companhia Energetica de Minas Gerais (Brazil); Quintana, V.H. [Univ. of Waterloo, Ontario (Canada)] [Univ. of Waterloo, Ontario (Canada)

1997-04-01T23:59:59.000Z

129

Environmental Assessment of Proposed Filbert Substation and Tap Project.  

SciTech Connect

The proposal is a cooperative (jointly funded and owned) action between Bonneville Power Administration (BPS) and FGLandP involving construction of the 115/12.5-kV Filbert Substation. BPA would also build a 0.8-mile overhead 115-kV tapline from BPA's Forest Grove-McMinnville 115-kV line to the proposed substation. The Forest Grove-McMinnville transmission line has available capacity to support the proposed substation. The FGLandP would build four underground distribution circuits to connect the substation to its existing distribution system. It is normally BPA's practice to consider several substation location alternatives as a part of its facility siting process. The proposed substation site was recommended after a preliminary field evaluation by BPA determined that building on the proposed site was preferable because available sites south of the Tualatin Valley Highway and Southern Pacific Railroad were either on presently cultivated farmland, were in a floodplain, or were inaccessible without extensive access road construction. The proposed substation site is owned by FGLandP, is designated for use as a utility substation in the Forest Grove Comprehensive Plan, and was purchased by FGLandP in anticipation of a need for its use as a substation site because of its central location in relation to existing and forecasted loads. The site is accessible from Filbert Street (city road), and is gently sloping. This report describes potential environmental impacts of the proposed actions.

United States. Bonneville Power Administration.

1984-03-01T23:59:59.000Z

130

Design and dimensioning of pressure vessel for a marine substation.  

E-Print Network (OSTI)

?? This thesis presents the mechanical design and dimensioning of a pressure vessel, which is to be used as housing for a marine substation in… (more)

Eriksson, Lars

2010-01-01T23:59:59.000Z

131

Voltage stabilization system in traction substation of urban electric transport  

Science Journals Connector (OSTI)

The direct current-voltage stabilization system using a high-frequency link in traction substations of urban electric transport based on applying...

S. V. Shapiro; S. F. Muftiev

2011-02-01T23:59:59.000Z

132

On divergence, relative entropy and the substate property  

E-Print Network (OSTI)

In this article we study relationship between three measures of distinguishability of quantum states called as divergence, relative entropy and the substate property.

Jain, R; Sen, P; Jain, Rahul; Radhakrishnan, Jaikumar; Sen, Pranab

2005-01-01T23:59:59.000Z

133

Wireless technology(ZigBee) for communication in substation.  

E-Print Network (OSTI)

??Automation plays a important role in the electric substation. The lack of controlling and monitoring the devices may cause accidents. So automation of devices is… (more)

Kandela, Amit

2013-01-01T23:59:59.000Z

134

On divergence, relative entropy and the substate property  

E-Print Network (OSTI)

In this article we study relationship between three measures of distinguishability of quantum states called as divergence, relative entropy and the substate property.

Rahul Jain; Jaikumar Radhakrishnan; Pranab Sen

2005-06-24T23:59:59.000Z

135

Substation automation systems and IEC 61850: interoperability testing.  

E-Print Network (OSTI)

??Dissertação de mest., Engenharia Electrónica e Telecomunicações, Faculdade de Ciências e Tecnologia, Univ. do Algarve, 2011 The Substation Automation System (SAS) is the backbone of… (more)

Evaristo, Henrique A. Guerreiro Dias

2011-01-01T23:59:59.000Z

136

The Design of Partial Electric and Control System for 500kV Substation  

Science Journals Connector (OSTI)

The good design of the electric section in substation and its stable move may effect the electrical system of substation directly, this paper aim at the design of an electric primary section in substation and its...

Haimei Xiao; Lichun Shi

2012-01-01T23:59:59.000Z

137

The high-voltage substation configuration influence on the estimated lightning performance  

Science Journals Connector (OSTI)

The substation configuration has a great influence on the ... at the lines connected in front of the substations. In most of the analyses the critical substation configuration is assumed with only one connected ....

Z. Stojkovi?; M. S. Savi?

1997-08-01T23:59:59.000Z

138

A New Method for Substation Planning Problem Based on Weighted K-Means  

Science Journals Connector (OSTI)

Substation planning is considered the most important step ... and distribution system. In this paper, the substation planning problem is looked as a clustering ... loads into several clusters. The capacity of substation

Wen Peng; Wenxia Liu

2009-01-01T23:59:59.000Z

139

Novel Approach for Detecting Network Anomalies for Substation Automation based on IEC 61850  

Science Journals Connector (OSTI)

An SA (Substation Automation) system based on IEC 61850 is an intelligent substation; it has been receiving considerable attention as ... critical national infrastructures including the power grid. Substation Aut...

Hyunguk Yoo; Taeshik Shon

2014-03-01T23:59:59.000Z

140

Environmental Assessment : Happy Valley [Substation Project].  

SciTech Connect

The proposed Happy Valley project consists of construction of a new BPA customer service 69-kV substation south of Sequim in Clallam County, Washington. A tie line, to be constructed by the customer as part of this project, will link the new BPA facility to the existing customer's transmission system in the area. This project responds to rapid load growth in the Olympic Peninsula, and will strengthen the existing BPA system and interconnected utility systems. It will reduce transmission losses presently incurred, especially on the BPA system supplying power to the Olympic Peninsula. This report describes the potential environmental impact of the proposed actions. 2 figs., 1 tab.

United States. Bonneville Power Administration.

1982-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

The Remote Video Monitoring System Design and Development for Underground Substation Construction Process  

Science Journals Connector (OSTI)

From the current situation of underground substation construction in China, we design and development ... image enhancement technology, the construction of underground substation can be clearly and accurately tra...

Siguo Zheng; Yugan You; Fanguang Li; Gang Liu

2012-01-01T23:59:59.000Z

142

The choice of substation electric connection circuits: a unified or an individual approach?1  

Science Journals Connector (OSTI)

Typical substation electric connection circuits, used at the present ... analyzed. Some versions of the use of substation distributor circuits for controlling electric network modes ... analyzed. Recommendations ...

V. P. Budovskii; V. V. Ushakov

2011-07-01T23:59:59.000Z

143

The Study of Substation Automation Remote Communication for Multi-granularity Access Control System  

Science Journals Connector (OSTI)

This paper based on the demands of access control of substation automation system, analyzed two operation objects of ... can fulfill the needs of access control in substation automation.

Lichun Shi; Haimei Xiao

2012-01-01T23:59:59.000Z

144

Assembly and function-test of the main circuit for a marine substation.  

E-Print Network (OSTI)

?? At the Division for Electricity at Uppsala University a new marine substation for waveenergy is being built. The marine substation is required to connect… (more)

Ferhatovic, Senad

2010-01-01T23:59:59.000Z

145

Progress Report, Substation No. 8, Lubbock, Texas, 1909-1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 219 SEPTEMBER, 1917 PROGRESS REPORT, SUBSTATION NO. 8, LUBBOCK, TEXAS B. YOUNGBLOOD, DIR.ECTOR COLLEGE STATION, BRAZOS COUNTY, TEXAS, AGRICULTURAL AND MECHANICAL COLLEGE OF TEXA W. B. BIZZELL... STATION COMMITTEE L. J. HART, Chairman 'WILL A. MILLER, JR. GOVERNING BOARD, STATE SUBSTATIONS P. L Downs President Temple ........ .............................................................................Term CHA ~LES RO~AN, Vice >resident,. AU...

Karper, R. E. (Robert Earl)

1917-01-01T23:59:59.000Z

146

Progress Report of Substation No. 12, Chillicothe, Texas, 1905- 1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION L BULLETIN NO. 202 DECEMBER, 1916 PROGRESS REPORT OF SUBSTATION NO. 1 2, CHILLICOTHE, TEXAS R. W. EDWARDS, B. S., SUPERINTENDENT POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY, TEXAS. - AUSTIN, TEXAS... ................................................................................................ Term expires 1921 MAIN STATION COMMITTEE L. J. HART; Chairman J. S. WILLIAMS W. A. 'MILLER, Jr- GOVERNING BOARD, STATE SUBSTATIONS p L DOWNS President Temple ............................................................................... Term...

Edwards, R.W.

1916-01-01T23:59:59.000Z

147

Progress Report, Substation No. 9, Pecos, Texas, 1910-1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION * BULLETIN NO. 221 NOVEMBER, 19 17 -- -- PROGR.ESS REPORT, SUBSTATION NO. 9, PECOS, TEXAS COLLEGE STATION, RRAZOS COUNTY, TEXAS. AUSTIN, TEXAS : VON BOECKMANN-JONES CO., PRINTERS, 1917 AGRICULTURAL...% .................................................................................................... F. M. LAW, Houston em expires 1923 MAIN STATION COMMITTEE L. J. HART. Chairman WILL A. MILLER, JR GOVERNING BOARD, STATE SUBSTATIONS p L DOWNS, Temple. President...

Jackson, J.W.

1917-01-01T23:59:59.000Z

148

Experiments at Substation No. 3 Angleton, Texas 1909-1916.  

E-Print Network (OSTI)

~OLLEGE OF TEXAS LTBM~~~-~~~ AS AGRICULTURAL EXPERIMENT STATION - BULLE~JN NO. 229 MAY, 1918 -- EXPERIMENTS AT SUBSTATION NO. 3 ANGLETON, TEXAS B. Y OUNGBLO OD, DIRECTOR OOUEGE STATION, BRAZOS COUNTY, TEXAS. ' "RICULTURAL AND MECHANICAL... SUBSTATIONS P.'L. Downs, President, Temple ............................................................................. Term expires 191< CHARLES ROGAN, Vlce Presldenf, Austin.. ............................................................... Term expires...

Winters, N. E. (Nathaniel Elmer)

1918-01-01T23:59:59.000Z

149

Progress Report Substation No. 5, Temple, Texas, 1910-1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 2 15 - MAY, 1917 PROGRESS REPORT, SUBSTATION NO. 5, TEMPLE, TEXAS . B. YOUNGBLOOD, DIRECTOR COLLEGE STATION, RRAZOS COUNTY, TEXAS. AGRICULTURAL AND MECHANICAL COLL ECE OF TEXAS W. B. BIZZELL... ............................................................................................... Term explres 192: MAIN STATION COMMITTEE L. J. HART, Chairman WILL A. MILLER, JR GOVERNING BOARD, STATE SUBSTATIONS P. L. DOWNS. Temple, President .................................................................................. Term expires 1911...

Killough, D.T. (David Thornton)

1917-01-01T23:59:59.000Z

150

Evaluating Security Algorithms in the Substation Communication Architecture  

Science Journals Connector (OSTI)

Security becomes the major concern in a modernized electricity network. The IEC 61850 standard has been developed for substation automation, providing more enhancing communication functionalities. The standard defines several kinds of messages for data ... Keywords: IEC 61850, Substation Security, Message authentication, integrity

Sugwon Hong; Dae-Yong Shin; Myongho Lee

2009-09-01T23:59:59.000Z

151

Finite element analysis of substation composite insulators  

Science Journals Connector (OSTI)

Composite insulators are rapidly replacing their porcelain counterparts in electrical substation applications. These insulators consist of a glass-reinforced polymer (GRP) rod, with two metal end fittings radially crimped onto the ends of the rod during assembly. In this paper, axisymmetric finite element models are developed to evaluate the mechanical performance of composite insulators under externally applied axial compression. The analyses are performed by assuming both a perfectly bonded interface between the composite rod and the end fittings, and an imperfect interface which permits large relative sliding with Coulomb friction. Results indicate that the perfect interface model is unrealistic since it predicts singular stresses at the interface comer and an overall linear structural response. On the other hand, the imperfect interface model is found to simulate accurately the structural non-linearity caused by relative sliding of the GRP rod within the end fittings. The imperfect interface model has therefore been used to evaluate the effects of interface friction, and the extent of crimping, on the maximum load-bearing capacity of substation composite insulators.

A. Bansal; A. Schubert; M.V. Balakrishnan; M. Kumosa

1995-01-01T23:59:59.000Z

152

Grizzly Substation Fiber Optics : Environmental Assessment.  

SciTech Connect

This notice announces BPA`s decision to construct, operate, and maintain the Grizzly Substation Fiber Optic Project (Project). This Project is part of a continuing effort by BPA to complete a regionwide upgrade of its existing telecommunications system. The US Forest Service and BPA jointly prepared the Grizzly Substation Fiber Optic Project Environmental Assessment (EA) (DOE/EA-1241) evaluating the potential environmental impacts of the Proposed Action, the Underground Installation Alternative, and the No Action Alternative. Based on the analysis in the EA, the US Forest Service and BPA have determined that the Proposed Action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an Environmental Impact Statement (EIS) is not required and BPA is issuing this FONSI. The US Forest Service has separately issued a FONSI and Decision Notice authorizing BPA to construct, operate, and maintain the Project within the Crooked River National Grassland (Grassland).

United States. Bonneville Power Administration.

1998-02-01T23:59:59.000Z

153

BRIEFINGS ON PHYSICAL SECURITY OF ELECTRICITY SUBSTATIONS - SAN JOSE, CA  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

BRIEFINGS ON PHYSICAL SECURITY OF ELECTRICITY SUBSTATIONS - SAN BRIEFINGS ON PHYSICAL SECURITY OF ELECTRICITY SUBSTATIONS - SAN JOSE, CA BRIEFINGS ON PHYSICAL SECURITY OF ELECTRICITY SUBSTATIONS - SAN JOSE, CA Briefings on Physical Security of Electricity Substations The Department of Energy (DOE) and Department of Homeland Security (DHS), in coordination with the Federal Bureau of Investigation, the Federal Energy Regulatory Commission's Office of Energy Infrastructure Security, the Electricity Sector Information Sharing and Analysis Center (ES-ISAC), North American Electricity Reliability Corporation (NERC), and industry experts, will conduct a series of briefings across the country with electricity sector owners and operators, and local law enforcement on the physical security of electricity substations. The session for FEMA Region IX will be held in San Jose, CA and hosted by

154

Data:93248299-1678-4cce-ac76-62cafc6dfb3b | Open Energy Information  

Open Energy Info (EERE)

48299-1678-4cce-ac76-62cafc6dfb3b 48299-1678-4cce-ac76-62cafc6dfb3b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Moon Lake Electric Assn Inc Effective date: 2000/07/01 End date if known: Rate name: SCHEDULE IS-2 - INDUSTRIAL SERVICE Sector: Industrial Description: AVAILABILITY: Available for Consumers who take service directly from the Association's 4,160 volt, 12,500 volt or 24,900 volt substation bus. Subject to the established rules and regulations of the Association. CONDITIONS FOR SERVICE: All conductors, pole lines, and other electrical equipment beyond the substation bus on Consumer side of meter shall be considered the distribution system of the Consumer, and shall be furnished and maintained by the Consumer. MINIMUM MONTHLY CHARGE: $2,198.00 plus any increase required under the Line Extension Policy. POWER FACTOR ADJUSTMENT: Demand charges will be adjusted for Consumers with an average monthly power factor less than 90% lagging. Such adjustments will be made by increasing the billing demand 1% for each 1% by which the average power factor is less than 90% lagging.

155

Feasibility study: Application of RCM techniques for substation maintenance at the Bonneville Power Administration  

SciTech Connect

This feasibility study examines reliability centered maintenance (RCM) as it applies to Bonneville Power Administrations (BPA) substation maintenance program. Reliability techniques are examined in evaluated. Existing BPA equipment maintenance procedures are documented. Equipment failure history is considered. Economic impacts are estimated. Various equipment instrumentation methods are reviewed. Based on this analysis a prototype system is proposed. The prototype will be implemented in two phases. Phase 1 is to be completed in 1992, it includes instrumenting one power transformer and one oil circuit breaker. Software development will focus on displaying data. Phase 2 is to be completed the following year. The remaining transformers and breakers will be instrumented during the second phase. Software development will focus on predictive maintenance techniques and maintenance decision support.

Purucker, S.L.; Tonn, B.E.; Goeltz, R.T.; James, R.D.; Kercel, S.; Rizy, D.T.; Simpson, M.L.; Van Dyke, J.W.

1992-05-28T23:59:59.000Z

156

Testing of complex IEC 61850 based substation automation systems  

Science Journals Connector (OSTI)

The integration of multifunctional intelligent substation devices (ISDs), in complex substation or power plant automation systems, requires the development of methods and tools for their testing that will ensure the correct operation of protection, control, monitoring, recording and metering functions, under normal and abnormal system conditions. The new IEC 61850 standard for communication networks and systems in substations allows the development of high-speed peer-to-peer communications based distributed applications, based on multicast of status changes or sampled analogue values. This paper details the requirements for the testing of complex substation automation systems. The testing methods need to correspond to the functional hierarchy of the substation automation system. Functional element testing, integration and system testing are discussed. Systems with Substation Bus only, and with both Process Bus and Substation Bus, are considered. A method for the testing of both types of system is proposed, based on a specific order of system components testing. Solutions for the testing of the individual components of the IEC 61850 based system, as well as for the testing of distributed applications, are described at the end of the paper.

Alexander Apostolov

2008-01-01T23:59:59.000Z

157

Microsoft Word - CX -Ostrander Substation Expansion.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6, 2011 6, 2011 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Amit Sinha Project Manager - TEP-CSB-2 Proposed Action: Ostrander Substation Addition Budget Information: Work order 00262568 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.11 Construction of electric power substations (including switching stations and support facilities)....or modification (other than voltage increases) of existing substations and support facilities... Location: Clackamas County, Oregon (T2S, R3E, Sections 26 and 35) Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to expand its existing Ostrander Substation near Barton, Oregon by approximately 4 acres. The expansion would accommodate three new 230/500-kV transformers,

158

Substation in Clark County, Nevada RECORD OF CATEGORICAL EXCLUSION DETERMINATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Substation for soil remediation. Substation for soil remediation. The attached map shows the borrow area which is situated in Sections 18, 19,20 Township 18 South Range 64 East, Mount Diablo Meridian, Clark County, Nevada. The corresponding U.S.G.S. 7.S-minute topographic maps are Apex, Dry Lake, Dry Lake NW, and Dry Lake SE, Nevada. B. Categorical Exclusion Applied: 10 CFR, Part 1021, Subpart D, Appendix B, B4.11: "Construction of electric power substations with power delivery at 230kV or below or modification of existing sUbstations." C. Regulatory Requirements in 10 CFR 1021.410 Ib): 1. The proposed action fits within a class of actions that is listed in Appendix B to Subpart D. a. The proposed action was reviewed for the requirements of the Endangered Species Act, the National Environmental Policy Act (NEPA), the National

159

Substation in Clark County, Nevada RECORD OF CATEGORICAL EXCLUSION DETERMINATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SUbstation for soil remediation. SUbstation for soil remediation. The attached map shows the borrow area which is situated in Sections 18, 19,20 Township 18 South Range 64 East, Mount Diablo Meridian, Clark County, Nevada. The corresponding U.S.G.S. 7.5-minute topographic maps are Apex, Dry Lake, Dry Lake NW, and Dry Lake SE, Nevada. B. Categorical Exclusion Applied: 10 CFR, Part 1021, Subpart D, Appendix B, B4.11: "Construction of electric power substations with power delivery at 230kV or below or modification of existing SUbstations." C. Regulatory Requirements in 10 CFR 1021.410 (b): 1. The proposed action fits within a class of actions that is listed in Appendix B to Subpart D. a. The proposed action was reviewed for the requirements of the Endangered Species Act, the National Environmental Policy Act (NEPA), the National

160

Microsoft Word - CX_Memo_FranklinSubstation.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Amy Freel Amy Freel Project Manager - TEP-TPP-1 Proposed Action: Franklin Substation Upgrades Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.11 Electrical power substations and interconnection facilities Location: Pasco, Washington Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: The BPA proposes to make improvements to the BPA fee-owned Franklin Substation located in southeastern Washington in order to bring the substation into compliance with BPA's minimum voltage guidelines. A shunt capacitor bank would be installed to provide voltage support. Project activities would include moving a temporary mobile capacitor bank, removing transformers, extending a 115-kilovolt (kV) bus, installing a new 115-kV

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Proposed Transmission Towers Proposed New Substation Sites Proposed...  

NLE Websites -- All DOE Office Websites (Extended Search)

6-1E: Recreation Inset Maps for Map 6-1C and Map 6-1D Proposed Transmission Towers Proposed New Substation Sites Proposed Route Segments (not drawn to scale) New Access Roads...

162

Gas-Insulated Substation Performance in Brazilian System  

Science Journals Connector (OSTI)

This work is based on a report developed in the Working Group 23–03 of CIGRÉ-Brazil [1], about gas-insulated substations performance in the Brazilian electric system from...

H. J. A. Martins; V. R. Fernandes; R. S. Jacobsen

1991-01-01T23:59:59.000Z

163

Progress Report, Substation No. 2, Troup, Texas, 1901-1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATlQl -- BULLETIN NO. 209 JANUARY, 1917 -- --- PROGRESS REPORT, SUBSTATION NO. 2, TROUP, TEXAS B. YOUNGBLOOD, DIRECTOR, COLLEGE STATION, BRAZOS COUNTY, TEXAS. [Blank Page in Original Bulletin] I TEXAS... AGRICULTURAL EXPERIMENT STATION -- BULLETIN NO. 209 JANUARY, 1917 - PROGRESS REPORT, SUBSTATION NO., 2, TROUP,. TEXAS W. S. HOTCHKISS, . Superintendent B. YOTJVGBLOOD, DIRE:CTOR, COLLEGE STATION, RRAZOS COUNTY, TEXAS. - - fl AUSTIN, TEXAS VO K...

Hotchkiss, W.S.

1917-01-01T23:59:59.000Z

164

Progress Report Substation No. 1, Beeville, Texas, 1910-1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION -- BULLETIN NO. 2 14 APRIL, 1917 .PROGRESS REPORT, SUBSTATION NO. 1, BEEVILLE, TEXAS B. YOUNGBLOOD, ,If. S., DIRECTOR COLLEGE STATION, BRAZOS COUNTY, TEXAS. [Blank Page in Original Bulletin] TEXAS....'AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 214 APRIL, 1917 PROGRESS REPORT, SUBSTATION NO. 1, BEEVILLE, TEXAS 1910-1914 E. E. BINFORD, B. S., Superintendent B. YOUNGBLOOD, $1. S., DIRI~CTOR COLLEGE STATION, BRAZOS COUNTY, TEXM. em- AUSTIN, TEXAS : VON...

Binford, E.E.

1917-01-01T23:59:59.000Z

165

Progress Report Substation No.7, Spur, Texas, 1909-1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 2 18 SEPTEMBER, 1917 PROGRESS REPORT, SUBSTATION NO. 7, SPUR, TEXAS . , B. YOUNGBLOOD, DIRECTOR, COLLEGE STATION, BRAZOS COUNTY, TEXAS. AunlLuL I UKAL AIVD-~LIIAITYILAL LULLEECVPTE~A~ W. B.... ............................................... .Term expires 1923 F. M. LAW, Housto11.. ................................................. .Term expires 1923 MAIN STATION COMMITTEE L. J. HART. Chairman WILL A. MILLER, JR. GOVERNING BOARD, STATE SUBSTATIONS p. L. DOWNS, President, Temple...

Dickson, R.E.

1917-01-01T23:59:59.000Z

166

Corn Variety Experiments, Substation no. 3, Angleton, Texas.  

E-Print Network (OSTI)

XAS AGRICULl'URAL EXPERIMENT STATION ~ AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL. Preddent . FEBRUARY, 1921 DIVISION OF AGRONOMY CORN VARIETY EXPERIMENTS SUBSTATION NO. 3, t B. YOUNGBLOOD, DIRECTOR, %LLEOE STATION, BRAZOS... Assistant SOIL SURVEY **W. T. CARTER, JR., B. S.! Chiej T. M. BUSANELL, B: S., Sorl S~ruevot H. W. HAWKER. Sorl Surueuor No. I. Denton Denton County C. H. MCDO\\;ELL. B. S.. Superintenden( SUBSTATIONS No. 7. Spar, Dickene County R. E. DICKSON. B. S...

Reynolds, E. B. (Elbert Brunner)

1921-01-01T23:59:59.000Z

167

Sweet Potato Fertilizer Experiments at Substation No. 2, Troup.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, President BULLETIN NO. 277 MARCH, 1921 SWEET POTATO FERTILIZER EXPERIMENTS AT SUBSTATION NO. 2; TROUP B. YOUNGBLOOD, DIRECTOR tmLLIU)E BTATION.... Pecos, Reeves County V. L. CORY, B. S., Superintendent No. 10. College Station, Rrazas County (Feedlng and Breedlng Substation) L. J. MCCALL, Superintendent No. 11. Nacogdoches, Nacogdoches County G. T. McN~ss, Superintendent **No. 12. Chillicothe...

Hotchkiss, W. S.

1921-01-01T23:59:59.000Z

168

PP&L experience with substation reliability centered maintenance  

SciTech Connect

This paper is intended to present a summary of Pennsylvania Power & Light`s (PP&L) experience with substation Reliability Centered Maintenance (RCM). The purpose of this summary is to first explain the process used by PP&L to implement substation RCM, second to explain the differences that are apparent from the use of the classical RCM analysis as compared to the method used by PP&L, and third to provide several insights into the process.

Santarelli, P.D. [Pennsylvania Power & Light Company, Hazleton, PA (United States)

1996-08-01T23:59:59.000Z

169

Study of gas insulated substation and its comparison with air insulated substation  

Science Journals Connector (OSTI)

Abstract This paper basically evaluates the two types of substation namely AIS and GIS on the basis of the life-cycle cost method, reliability, and environmental effects. The problems of very fast transient oscillations (VFTO) faced in GIS and their possible solutions. It substantiates and supports the use of GIS over AIS with an in depth analysis. In the end, HIS (hybrid GIS) has been proposed as a solution to overcome drawbacks of both AIS and GIS and to use the advantages of both in a single system for the best results.

Raj Nagarsheth; Sushant Singh

2014-01-01T23:59:59.000Z

170

Feasibility of thyristor controlled series capacitor for distribution substation enhancements  

SciTech Connect

While Thyristor Controlled Series Capacitors (TCSCs) are already being used for control of transmission system power flows, the dynamic adjustment of transmission infeed impedances presents other system enhancement opportunities. In the case of the Con Edison system, distributing substation upgrades are severely constrained by limits to existing circuit breaker interrupting capabilities. Because additional transmission line infeeds cannot be provided without increasing fault current levels, a TCSC was investigated for use as a fault current limiter. In order to demonstrate proper operation in the current limiting mode, Electromagnetic Transients Program (EMTP) simulations were conducted. Three TCSC configurations are presented to illustrate that additional power can be provided during normal operation without increasing fault currents at the substation: (1) series compensation of existing 138 kV infeeds (to allow higher substation MVA uprates), (2) series compensation of new 138 kV infeeds (without fault current increases), and (3) a 13.8 kV TCSC compensated link between two substations (to allow regulated power transfer between substation buses).

Godart, T.F.; Imece, A.F.; McIver, J.C. [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.; Chebli, E.A. [Consolidated Edison Co. of NY, Inc., New York, NY (United States)

1994-12-31T23:59:59.000Z

171

Feasibility of thyristor controlled series capacitor for distribution substation enhancements  

SciTech Connect

While Thyristor Controlled Series Capacitors (TCSCs) are already being used for control of transmission system power flows, the dynamic adjustment of transmission infeed impedances presents other system enhancement opportunities. In the case of the Con Edison system, distribution substation upgrades are severely constrained by limits to existing circuit breaker interrupting capabilities. Because additional transmission line infeeds cannot be provided without increasing fault current levels, a TCSC was investigated for use as a fault current limiter. In order to demonstrate proper operation in the current limiting mode, Electromagnetic Transients Program (EMTP) simulations were conducted. Three TCSC configurations are presented to illustrate that additional power can be provided during normal operation without increasing fault currents at the substation: (1) series compensation of existing 138 kV infeeds (to allow higher substation MVA uprates), (2) series compensation of new 138 kV infeeds (without fault current increases), and (3) a 13.8 kV TCSC compensated link between two substations (to allow regulated power transfer between substation buses).

Godart, T.F.; Imece, A.F.; McIver, J.C. [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.] [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.; Chebli, E.A. [Consolidated Edison Co. of New York Inc., New York, NY (United States)] [Consolidated Edison Co. of New York Inc., New York, NY (United States)

1995-01-01T23:59:59.000Z

172

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: Estes to Flatiron Substation Transmission Lines Rebuild 3: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO SUMMARY DOE's Western Area Power Administration (Western) owns and operates two 16-mile, 115-kilovolt transmission lines on separate rights-of-way between Flatiron Reservoir (near Loveland, Colorado) and the town of Estes Park, Colorado. Western is preparing this EIS to evaluate the environmental impacts of a proposal to upgrade and co-locate these transmission lines, by removing one and abandoning its right-of-way, and rebuilding the other along the existing right-of-way as a double-circuit line (i.e., six conductors per pole). The USDA Forest Service, Arapaho and Roosevelt National Forest, is a cooperating agency in preparing the EIS to support

173

Microsoft Word - CX- Eugene Substation Fiber_130520.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3 3 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Jonathan Toobian Project Manager - TPC-TPP-4 Proposed Action: Eugene Substation Fiber Interconnection Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B 4.7 Fiber Optic Cable Location: Eugene, Lane County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes allowing Light Speed Networks (LSN) to interconnect with its existing fiber optic network at BPA's Eugene substation in Lane County, Oregon. To interconnect to BPA's fiber network, LSN would install two new below ground fiber optic vaults within BPA's existing right-of-way. The first vault would be installed on BPA fee-owned land immediately south of the existing substation entrance, while the second vault

174

Reliability and component importance analysis of substation automation systems  

Science Journals Connector (OSTI)

This paper aims to present a comprehensive technique to quantitatively assess the reliability of substation automation systems. The technique is based on the tie-sets methodology. In order to demonstrate the application of the proposed technique, a variety of substation automation architectures is first introduced. The associated reliability block diagrams as well as the exact system reliability are then given. The impacts and the degree of importance of various components on the reliability of substation automation systems are presented. Two suitable measures of importance are selected. The first is the Birnbaum’s measure used to determine the bottleneck of the system reliability. The second measure uses criticality importance to diagnose failures and generating repair or inspection checklists.

Hamze Hajian-Hoseinabadi

2013-01-01T23:59:59.000Z

175

A complete and normalized 61850 substation (Smart Grid Project) | Open  

Open Energy Info (EERE)

complete and normalized 61850 substation (Smart Grid Project) complete and normalized 61850 substation (Smart Grid Project) Jump to: navigation, search Project Name A complete and normalized 61850 substation Country Spain Headquarters Location Madrid, Spain Coordinates 40.488735°, -3.284912° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.488735,"lon":-3.284912,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

176

Implementation and design of a communication system of an agent-based automated substation  

Science Journals Connector (OSTI)

A substation system requires that communication be transmitted reliably, ... the communication system of an agent-based automated substation is introduced. The running principle is discussed ... realization of th...

Yong-jun Lin; Yu-tao Liu; Dan-hui Zhang

2006-12-01T23:59:59.000Z

177

Concerted Interconversion between Ionic Lock Substates of the b2 Adrenergic Receptor Revealed by Microsecond  

E-Print Network (OSTI)

Concerted Interconversion between Ionic Lock Substates of the b2 Adrenergic Receptor Revealed substates (2,5). Recently solved crystallographic structures of b2-adren- ergic receptor (B2AR) have shown

178

Research on Secure Message Transmission of Smart Substation Based on GCM Algorithm  

Science Journals Connector (OSTI)

Based on IEC61850 standard smart substation system using ethernet architecture is required for ... , MMS are common messages used in smart substation , whether these messages can be transmitted ... is critical to...

BaoYi Wang; MinAn Wang; ShaoMin Zhang

2012-01-01T23:59:59.000Z

179

Electrical Substation Performability and Reliability Indicators Modelled by Non-Homogeneous Markov Chains  

Science Journals Connector (OSTI)

In the scope of operating safety in electrical substations, EDF is brought to perform reliability and ... availability computations. These computations declined on the substation performance are used to estimate ...

Agapios Platis; Nikolaos Limnios; Marc Le Du

1996-01-01T23:59:59.000Z

180

Fuzzy Control on Voltage/Reactive Power in Electric Power Substation  

Science Journals Connector (OSTI)

A fuzzy method using in voltage and reactive power control in electric substation is proposed based on the improved 17 ... times at the tap positions of transformers in substation are much less than usual. So,...

Xiu-hua Wu; Jun-cheng Wang; Ping Yang…

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Shared-network scheme of SMV and GOOSE in smart substation  

Science Journals Connector (OSTI)

The network structure of the smart substation in common use was introduced, and the ... measured value (SMV) and generic object oriented substation event (GOOSE) were analyzed, such as ... the network reliabilit...

Wenlong WANG; Minghui LIU; Xicai ZHAO…

2014-09-01T23:59:59.000Z

182

Chromosomal effects in lymphocytes of 400 kV-substation workers  

Science Journals Connector (OSTI)

In a previous study we found an increased rate of chromosomal aberations in substation workers. To follow up this finding we ... of circuit breakers and disconnectors in 400 kV-substations. The other 19 served as...

I. Nordenson; K. Hansson Mild; U. Östman…

1988-01-01T23:59:59.000Z

183

Criteria for phase-to-phase clearances of HV substations  

SciTech Connect

To facilitate uprating of HV substations, the paper re-examines line-to-line insulation design criteria. The basis for existing practices and the principles of line-to-line lightning surge overvoltage stresses are reviewed. Results of a digital study for a realistic substation are presented. The conclusions show that the line-to-line stresses, as limited by surge arresters, are substantially higher than line-to-ground stresses. This represents increased requirements as compared to existing standards. However, due to low protective levels of modern arresters, substantial reduction of line-to-line clearances is still feasible.

Panek, J.; Sublich, M.; Elahi, H. (GE Industry and Utility Sales, Schenectady, NY (US))

1990-01-01T23:59:59.000Z

184

Cotton Variety Experiments at Substation No. 2, Troup.  

E-Print Network (OSTI)

-*-:?;,*f{*;".!( pcyv-p, ., AT SUBSTATION NO. 2, ci TROUP . AGRICULTURAL A.ND MECHANICAL COLLEGE OF TEXAS T. 0. WALTON, President STATION STAFF? ADMINISTRATION : A. B. CONNER, M. S., Director R E KARPER M S Vice-Director CLAR'ICE MIXAN 'B"A Secretary M P.... S. Department of Agriculture. ***In cooperation wlth the School of Agr~culture. icine. In tests conducted with 205 varieties and strains of cotton t Substation No. 2, Troup, during the 16 years, 1913 to 1928, ~clusive, Half and Half...

Hotchkiss, W. S.; Johnson, P. R. (Paul Rufus)

1930-01-01T23:59:59.000Z

185

Report of Experiments at Substation No. 12, Chillicothe, Texas.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, President BULLETIN NO. 253 NOVEMBER, 1919 heport of Exoeriments at Substation . No. 12, iliicothe, Texas B. YOUNGBLOOD, DIRECTOR aOuEoE STATION... Survegor R. G. BRTWER, B. S., Assisfanf Animal Hus- W. B. FR~NCIS, B. S., Soil Surve~or banaman SUBSTATIONS No. 1. Beevillei Bee County I. E. CLU~ART, M. S., Superinfendent N6. 2. Tromp, Smith County W. S. HOTCHKISS, Superinfendenf No. 3. Angleton...

Edwards, R. W.

1919-01-01T23:59:59.000Z

186

Cotton Variety Experiments: Substation No. 3, Angleton, Texas  

E-Print Network (OSTI)

TEXAS AfiRlCULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS ' W. B. BIZZELL, President BULLETIN NO. 274 FEBRUARY, 1921 DIVISION OF AGRONOMY COTTON VARIETY EXPERIMENTS SUBSTATION NO. 3, ANGLETON, TEXAS B. YOUNGBLOOD..... Chief SOIL SURVEY **W. T. CARTER. JR., B, S.. Chief T. M RTJRNNELL. R. S., Soil Surve~or H. W. HAWKER. Soil Sr~rneuar SUBSTATIONS No..l. Beeville. Bee County No. 8. Lubbock. Lubbock County I. E. COWART, M. S., Superintendent H. E. KARPER. B. S...

Reynolds, E. B. (Elbert Brunner)

1921-01-01T23:59:59.000Z

187

Progress Report, Substation No. 11, Nacogdoches, Texas, 1909-1915.  

E-Print Network (OSTI)

I 2XAS AGRlCULrURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, President BULLETIN NO. 237 NOVEMBER, 1918 Progress Report, Substation No. 1 1, Nacogdoches, Texas, 1909- 19 15 B. YOUNGBLOOD, DIRECTOR College.... T CARTER JR Chief J. F. ST~OUD. SO;[ ~;rve!,or NFAL GEARREALD Soil Survegor T. M. BUSHNELL, b. S., Soil Survey'r SUBSTATIONS No. 1. Beeville. Bee County No. 8 Lubbock Lubbock County I. E. COWART, M. S., Superintendent R'E KARPE~ B S Superintend D: L...

McNess, George Thomas

1918-01-01T23:59:59.000Z

188

Environmental Assessment of Proposed Haskill Substation and Tap Line.  

SciTech Connect

To solve the service problems in the Marion area, BPA is proposing to construct a new 230/24.9-kV substation to tap BPA's existing Libby-Conkelly 230-kV line (different than Hot Springs-Conkelly 230-kV line, but an equally acceptable source). Haskill Substation would be approximately one mile northeast of the town of Marion, Montana, and would serve the western portion of Flathead Electric Cooperative's service area. This report describes possible environmental impacts of the proposed action. 8 refs., 4 figs.

Not Available

1984-05-01T23:59:59.000Z

189

A short proof of the Quantum Substate Theorem  

E-Print Network (OSTI)

The Quantum Substate Theorem due to Jain, Radhakrishnan, and Sen (2009) gives us a powerful operational interpretation of the observational divergence of two quantum states, a quantity that is closely related to their relative entropy. Informally, the theorem states that if the observational divergence between two quantum states rho, sigma is small, then there is a quantum state rho' close to rho in trace norm, such that rho' when scaled down by a small factor becomes a substate of sigma. We present a new proof of this theorem. The resulting statement is stronger and its proof is both conceptually simpler and significantly shorter than the earlier proof.

Jain, Rahul

2011-01-01T23:59:59.000Z

190

Application Filling Requirements for Transmission Line and Substation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Application Filling Requirements for Transmission Line and Application Filling Requirements for Transmission Line and Substation Construction Projects (Wisconsin) Application Filling Requirements for Transmission Line and Substation Construction Projects (Wisconsin) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Wind Solar Program Info

191

Report on Experiments with Citrus Fruits at the Beeville Sub-station.  

E-Print Network (OSTI)

!TEXAS AGRICULTURAL EXPERIMENT STATIONS BULLETIN No. 148. MAY, 1912. Report on Experiments With Citrus Fruits at The Bee- ville Sub-station A. T. POTTS, Superintendent Beeville Sub-station AUSTIN PRINTING COMPANY AUSTIN. TEXAS TEXAS... EXPERIMENT STATIONS. GOVERNING BOARD. 1 DIRECTOR OF STATIONS. ...................................... B. YOUNOBLOOD, M. S.. .College Station I SUPERINTENDENTS OF SUB-STATIONS. .................. E. E. BINFORD, Beeville Sub-station.. .Beeville, P:.e Cc...

Potts, A. T. (Arthur Tillman)

1912-01-01T23:59:59.000Z

192

Feasibility study: Application of RCM techniques for substation maintenance at the Bonneville Power Administration. [Reliability Centered Maintenance (RCM)  

SciTech Connect

This feasibility study examines reliability centered maintenance (RCM) as it applies to Bonneville Power Administrations (BPA) substation maintenance program. Reliability techniques are examined in evaluated. Existing BPA equipment maintenance procedures are documented. Equipment failure history is considered. Economic impacts are estimated. Various equipment instrumentation methods are reviewed. Based on this analysis a prototype system is proposed. The prototype will be implemented in two phases. Phase 1 is to be completed in 1992, it includes instrumenting one power transformer and one oil circuit breaker. Software development will focus on displaying data. Phase 2 is to be completed the following year. The remaining transformers and breakers will be instrumented during the second phase. Software development will focus on predictive maintenance techniques and maintenance decision support.

Purucker, S.L.; Tonn, B.E.; Goeltz, R.T.; James, R.D.; Kercel, S.; Rizy, D.T.; Simpson, M.L.; Van Dyke, J.W.

1992-05-28T23:59:59.000Z

193

Cleanroom Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Conventional Machining Engis Lapping and Polishing Machine MET One particle Counter Sand Blaster Cabinet Flycutting Machine Lithography Equipment Mann 600 Pattern Generator Oriel...

194

Seismic base isolation of gas insulated electrical substations: Comparison among different solutions  

SciTech Connect

Base isolation of an outdoor 170 kV Gas-Insulated Substation conforming to ENEL standardization is proposed. The analyzed GIS has two separated phases and its layout consists of a compact block composed of five bays and two High-to-Medium Voltage power transformers. The design has been carried out following the International Electrotechnical Commission (IEC) requirements for seismic qualification of HV equipment. Three solutions are presented, each making use of different isolation devices: High-Damping Steel-Laminated Rubber Bearings, helical springs and visco-dampers, Friction Pendulu devices. The procedures adopted in the design of the three isolation systems are briefly explained, pointing out advantages and drawbacks of each solution.

Serino, G. [Univ. di Napoli Federico II (Italy). Dipt. di Analisi e Progettazione Strutturale; Bettinali, F. [ENEL s.p.a., Milano (Italy). Centro di Ricerca Idraulica e Strutturale; Bonacina, G. [ISMES s.p.a., Seriate (Italy). Div. Indagini Strutturali

1995-12-31T23:59:59.000Z

195

Experience in the installation of a microprocessor system for controlling converter units of the Vyborg substation  

SciTech Connect

The experience in the installation of modern digital systems for controlling converter units at the Vyborg converter substation on the basis of advanced microprocessor devices is considered. It is shown that debugging of a control and protection system on mathematical and physical models does not guarantee optimum control of actual converter devices. Examples of advancing the control and protection system are described, the necessity for which has become obvious in tests of actual equipment. Comparison of oscillograms of processes before optimization of the control system and after its optimization and adjustment shows that the digital control system makes it possible to improve substantially the algorithms of control and protection in the short term and without changing the hardware component.

Gusakovskii, K. B.; Zmaznov, E. Yu.; Katantsev, S. V.; Mazurenko, A. K.; Mestergazi, V. A.; Prochan, G. G.; Funtikova, S. F. [High Voltage Direct Current Power Transmission Research Institute (NIIPT) (Russian Federation)

2006-01-15T23:59:59.000Z

196

Myoglobin-CO Conformational Substate Dynamics: 2D Vibrational Echoes and MD Simulations  

E-Print Network (OSTI)

Myoglobin-CO Conformational Substate Dynamics: 2D Vibrational Echoes and MD Simulations Kusai A over a range of temperatures. The A1 and A3 conformational substates of MbCO are found to have assignments for the MbCO conformational substates. INTRODUCTION Protein dynamics have been the focus of both

Fayer, Michael D.

197

Short proofs of the Quantum Substate Theorem Rahul Jain and Ashwin Nayak  

E-Print Network (OSTI)

1 Short proofs of the Quantum Substate Theorem Rahul Jain and Ashwin Nayak Abstract--The Quantum Substate Theorem due to Jain, Rad- hakrishnan, and Sen (2002) gives us a powerful operational, such that when scaled down by a small factor becomes a substate of . We present new proofs of this theorem

Jain, Rahul

198

Design Considerations for a Large-Scale Wireless Sensor Network for Substation Monitoring  

E-Print Network (OSTI)

Design Considerations for a Large-Scale Wireless Sensor Network for Substation Monitoring Asis University City Blvd. Charlotte, NC 28223 Luke Van der Zel and Bienvenido Rodriguez Substations Group EPRI-Transmissions & Substations 9625 Research Drive Charlotte, NC 28262 Ralph McKosky Technology Innovation, Environment

Nasipuri, Asis

199

Preprint of the paper "A Boundary Element Numerical Approach for Substation Grounding in a Two  

E-Print Network (OSTI)

Preprint of the paper "A Boundary Element Numerical Approach for Substation Grounding in a Two://caminos.udc.es/gmni #12;A BOUNDARY ELEMENT NUMERICAL APPROACH FOR SUBSTATION GROUNDING IN A TWO LAYER EARTH STRUCTURE3~na, SPAIN SUMMARY Analysis and design of substation grounding requires computing the distribution

Colominas, Ignasi

200

An extension to IEC 61850 for solving selectivity problem in electrical substations Mohamad Haffar*,  

E-Print Network (OSTI)

An extension to IEC 61850 for solving selectivity problem in electrical substations Mohamad Haffar substations). The integration of communication networks in critical or safety applications is nowadays to the new standard IEC 61850. We also present the development of new devices in electrical substation domain

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Demo Abstract: Wireless Sensor Network for Substation Monitoring: Design and Deployment  

E-Print Network (OSTI)

Demo Abstract: Wireless Sensor Network for Substation Monitoring: Design and Deployment Asis-Transmissions & Substations 9625 Research Drive Charlotte, NC 28262 {lvanderz,birodriguez} @epri.com Ralph McKosky, Joseph in a substation for monitoring the health of power subsystems such as circuit breakers, trans- formers

Nasipuri, Asis

202

Preprint of the paper "A Boundary Element Formulation for the Substation Grounding Design"  

E-Print Network (OSTI)

Preprint of the paper "A Boundary Element Formulation for the Substation Grounding Design" I://caminos.udc.es/gmni #12;A BOUNDARY ELEMENT FORMULATION FOR THE SUBSTATION GROUNDING DESIGN I. Colominas, F. Navarrina A Boundary Element approach for the numerical computation of substation grounding systems is pre- sented

Colominas, Ignasi

203

Conformational Substates of Myoglobin Intermediate Resolved by Picosecond Xray Solution Scattering  

E-Print Network (OSTI)

Conformational Substates of Myoglobin Intermediate Resolved by Picosecond Xray Solution Scattering: Conformational substates of proteins are generally considered to play important roles in regulating protein with the conformational substates using picosecond X-ray solution scattering. By applying kinetic analysis considering all

Ihee, Hyotcherl

204

Noise Amplitude Distribution of Impulsive Noise from Measurements in a Power Substation  

E-Print Network (OSTI)

Noise Amplitude Distribution of Impulsive Noise from Measurements in a Power Substation Qingshan-This paper presents ultra-wide-band measurements of impulsive noise within an electricity substation compound analysis of these events is presented. Index Terms--Electricity substation, impulsive noise, noise

Atkinson, Robert C

205

The role of the digital fault recorder in the automated substation  

SciTech Connect

This paper addresses the role of the digital fault recorder in the automated substation. The topics of the paper include distributed architecture, the substation LAN and reduced installation costs, multiple functions, improved substation intelligence, record generation and record merging, fault summaries, master station software, and future considerations.

Brandt, J.D. [Hathaway Corp., Littleton, CO (United States)

1996-10-01T23:59:59.000Z

206

Myoglobin-CO Substate Structures and Dynamics: Multidimensional Vibrational Echoes and Molecular Dynamics  

E-Print Network (OSTI)

Myoglobin-CO Substate Structures and Dynamics: Multidimensional Vibrational Echoes and Molecular) having its imidazole nitrogen protonated (N -H). The two conformational substate structures B and R observed in the MD simulations are assigned to the spectroscopic A1 and A3 conformational substates of Mb

Fayer, Michael D.

207

New Solutions for Substation Sensing, Signal Processing and Decision Making M. Kezunovic, Fellow IEEE  

E-Print Network (OSTI)

New Solutions for Substation Sensing, Signal Processing and Decision Making M. Kezunovic, Fellow describes a new solution for integrating substation sensing, signal processing and decision making for more. Introduction The existing substation designs for sensing, signal processing and decision-making have been

208

Management and Control for Optimal Performance of the Heating Substation  

E-Print Network (OSTI)

With the development of the scale of central heating, a higher managing level is needed for the heating substation. How to economize the more energy is the first factor that managers need to consider while ensuring the comfort of the heating...

Yang, J.

2006-01-01T23:59:59.000Z

209

Acoustic modeling and simulation of an urban substation  

Science Journals Connector (OSTI)

Demographic growth has often resulted in a disorganized occupation of large urban areas. Regions which were previously empty started to be populated frequently resulting in an increasingly more common proximity between residential construction and industrial installations. As a consequence very serious environmental problems have occurred including those caused by acoustic emission from industrial installations. A common problem these days is the disturbance caused by electric substations closely positioned to residential buildings. The disregard for acoustic effects during the design stage can still be observed in some of the older substation designs particularly in areas previously far from city centers. In some countries such as Brazil a systematic acoustic evaluation of substations only started in the 1980s with the main bulk of the work still under development. This paper describes some of the joint work being carried out on noise control by the researchers of Universidade Federal de Minas Gerais and CEMIG (the state power administration). The initial definition of a series of acoustic elements followed by the discussion of the governing equations is considered. The computational implementation of the resulting model is presented aimed at the definition of the most convenient noise control strategy. Finally a few results obtained at a real substation are considered including some experimental results obtained during actual operation.

Eduardo Bauzer Medeiros; Gia Kroeff

1998-01-01T23:59:59.000Z

210

Simulation of an Electrical Substation Using the Bond Graph Technique  

Science Journals Connector (OSTI)

Simulation and especially computer simulation, is a basic tool since it enables engineers to understand how systems work without actually needing to see them. They can learn how they work in different circumstances and optimize their design with considerably ... Keywords: simulation, electrical substations, elements, electricity, bond graph

Gregorio Romero; Jesus Felez; Joaquin Maroto; Jose Manuel Mera

2008-04-01T23:59:59.000Z

211

Achieving low return temperatures from district heating substations  

Science Journals Connector (OSTI)

Abstract District heating systems contribute with low primary energy supply in the energy system by providing heat from heat assets like combined heat and power, waste incineration, geothermal heat, wood waste, and industrial excess heat. These heat assets would otherwise be wasted or not used. Still, there are several reasons to use these assets as efficiently as possible, i.e., ability to compete, further reduced use of primary energy resources, and less environmental impact. Low supply and return temperatures in the distribution networks are important operational factors for obtaining an efficient district heating system. In order to achieve low return temperatures, customer substations and secondary heating systems must perform without temperature faults. In future fourth generation district heating systems, lower distribution temperatures will be required. To be able to have well-performing substations and customer secondary systems, continuous commissioning will be necessary to be able to detect temperature faults without any delays. It is also of great importance to be able to have quality control of eliminated faults. Automatic meter reading systems, recently introduced into district heating systems, have paved the way for developing new methods to be used in continuous commissioning of substations. This paper presents a novel method using the temperature difference signature for temperature difference fault detection and quality assurance of eliminated faults. Annual hourly datasets from 140 substations have been analysed for temperature difference faults. From these 140 substations, 14 were identified with temperature difference appearing or eliminated during the analysed year. Nine appeared during the year, indicating an annual temperature difference fault frequency of more than 6%.

Henrik Gadd; Sven Werner

2014-01-01T23:59:59.000Z

212

The Application of Planning to Power Substation Voltage Control Keith Bell, Andrew Coles, Maria Fox, Derek Long and Amanda Smith  

E-Print Network (OSTI)

The Application of Planning to Power Substation Voltage Control Keith Bell, Andrew Coles, Maria Fox substations is a complex control task involving the coordination of interactions between cus- tomer demand and substation components. In this paper we look at the efficient management of substations in a pre-fault state

Coles, Andrew

213

VOLUME 67, NUMBER 1 PHYSICAL REVIEW LETTERS 1 JULY 1991 Optically Induced Coherence Transfer Echoes between Zeeman Substates  

E-Print Network (OSTI)

between Zeeman Substates Dieter Suter and Martin Rosatzin Institute of Quantum Electronics, Swiss Federal

Suter, Dieter

214

A comparative study on substation types and network layouts in connection with low-energy district heating systems  

Science Journals Connector (OSTI)

The study deals with low-energy District Heating (DH) networks operating in low temperatures such as 55 °C in terms of supply and 25 °C in terms of return. The network layout, additional booster pumps, and different substation types such as storage tanks either equipped or not equipped in domestic hot water production site were examined. Effects of booster pumps on pipe dimensions in the latter case were investigated. Temperature drops during the summer months due to low heat demands of consumers were explored. Use of approaches such as looped networks and branched network layouts with bypasses for end-consumers were also studied, heat loss from these networks and the drop in temperature in the heat-carrier-supply medium being compared.

Hakan ?brahim Tol; Svend Svendsen

2012-01-01T23:59:59.000Z

215

Microsoft Word - CX_Memo_MonroeSubstation.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2013 8, 2013 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Amy Freel Project Manager - TEP-TPP-1 Proposed Action: Monroe Substation Integrated Project Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.11 Electrical power substations and interconnection facilities Location: Snohomish County, Washington; Township 28 North, Range 7 East, Section 22 Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: The purpose of the project is to provide upgrades required as part of BPA's ongoing sustaining programs by providing voltage support and preventing power outages. The project would consist of the following activities: ï‚· Installation of two new 500-kilovolt (kV) shunt capacitor groups with current limiting

216

Microsoft Word - CX-Santiam_Substation_Renovation_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

KEPR-4 KEPR-4 SUBJECT: Environmental Clearance Memorandum Noah Carlson Project Manager - NWM-4 Proposed Action: Removal of asbestos and renovation of Santiam Substation PP&A Project No.: PP&A-1566 Budget Information: Work Order # 244751 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.16 Removal of asbestos from buildings Location: Santiam substation in Linn County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: This project entails the removal of all paint from all interior wall surfaces down to bare concrete as well as the removal of the suspended ceiling (painted with the same asbestos containing paint) and lighting systems. The asbestos containing floor tile will be removed as will the asbestos

217

Effects of intentional threats to power substation control systems  

Science Journals Connector (OSTI)

Power station control and management systems represent key elements for guaranteeing the security of the power grid infrastructure. Intrinsically conceived to support the continuous provision of power in secure conditions, those systems today make intensive use of information and communication systems and are therefore exposed to related accidental and intentional cyber threats. This paper describes a simulation of cyber attacks conducted in the CESI RICERCA laboratory testbed on a prototypical substation control infrastructure with the purpose of testing their feasibility and illustrating their impact on the control system services. A set of attack scenarios targeting several subsystems has been experimented, with different simulated threat motivations and different degrees of impact on the global substation service. The paper reports some considerations about the consequences of the implemented attacks, focusing on different facets of the problem, in an effort to elucidate the full significance of the potential cyber threats.

Giovanna Dondossola; Judit Szanto; Marcelo Masera; Igor Nai Fovino

2008-01-01T23:59:59.000Z

218

Dynamic sub-transmission substation expansion planning using learning automata  

Science Journals Connector (OSTI)

This paper presents a new method to solve the dynamic sub-transmission substation expansion planning (SSEP) in electric power distribution networks. The method employs a new algorithm based on learning automata for optimization process. The developed algorithm includes different electrical constraints such as voltage drops, thermal limits, power flow and radial flow constraints. Moreover, prevalent cost indices are taken into consideration. The proposed method is used to solve the dynamic SSEP for Birjand city, center of South-Khorasan province of Iran, up to the year 2024. In addition, effects of the dynamic and pseudo-dynamic planning models are investigated at the study region and the obtained results are compared to those of genetic algorithm. Detailed numerical results and comparisons presented in the paper show that the proposed approach leads to proper solutions and can be used as an effective tool for the dynamic sub-transmission substation expansion planning in an actual large scale distribution network.

Seyed Mahdi Mazhari; Hassan Monsef

2013-01-01T23:59:59.000Z

219

Optimal sparing for SF6 gas insulated substations  

Science Journals Connector (OSTI)

A method is suggested to optimize the number of spare items of substation components which have to be stored at the beginning of each year throughout a planning period. This sparing policy is conceived to provide the minimum total cost consisting of investment and load curtailment costs. The method uses the Hooke and Jeeves' direct search optimization approach. The optimization method is extended to apply to typical HV/MV GIS transformer stations requiring specific reliability modeling.

J. Nahman; V. Mijailovi?

1999-01-01T23:59:59.000Z

220

Substation based data interpretation techniques for improved power system management  

SciTech Connect

There is now considerable pressure on electric utilities to operate their systems in the most efficient manner possible and to provide increased quality of service to customers. This pressure, coupled with the decreasing availability of reserve margins dictates that there is a requirement for comprehensive system operation support through, among other things, the provision of quality information relating to the behavior of the primary and secondary systems. This paper will show how the data available within modern substation control and management systems can be exploited in a cost-effective manner, through the implementation of advanced substation functions in an open systems environment. Certain functions which are presently carried out at the control center could be distributed (or partially distributed) to the substation. These functions may provide the utility staff with quality information, which can in turn be used to satisfy the objectives of increasing quality and security of supply, in addition to optimizing the utility`s information, maintenance and asset management functions.

Booth, C.; McDonald, J.R. [Univ. of Strathclyde, Glasgow (United Kingdom). Centre for Electrical Power Engineering] [Univ. of Strathclyde, Glasgow (United Kingdom). Centre for Electrical Power Engineering; Laycock, W.J.

1997-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Data:D16cc4bb-b673-49ed-9bef-9921b7e503ac | Open Energy Information  

Open Energy Info (EERE)

cc4bb-b673-49ed-9bef-9921b7e503ac cc4bb-b673-49ed-9bef-9921b7e503ac No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Cp-1 Small Power Service Primary Metering Discount& Transformer Ownership Discount Sector: Commercial Description: Application: This rate will be applied to customers for all types of service if their monthly Maximum Measured Demand is in excess of 40 kilowatts (kW) per month for three or more months in a consecutive 12-month period, unless the customer exceeds the application conditions of the Cp-2 schedule. Customers billed on this rate shall continue to be billed on this rate until their monthly Maximum Measured Demand is less than 40 kW per month for 12 consecutive months. The utility shall offer customers billed on this rate a one time option to continue to be billed on this rate for another 12 months if their monthly Maximum Measured Demand is less than 40 kW per month. However, this option shall be offered with the provision that the customer waives all rights to billing adjustments arising from a claim that the bill for service would be less on another rate schedule than under this rate schedule Fixed Monthly Charge includes Commitment to Community Rider: $7.00 per customer per month Primary Metering Discount: Customers metered on the primary side of the transformer shall be given a 2.00 percent discount on the monthly energy charge, distribution demand charge, and demand charge. The PCAC and the monthly customer charge will not be eligible for the primary metering discount. Transformer Ownership Discount: Customers who own and maintain their own transformers or substations shall be given a credit of $0.25 per kW of distribution demand. Customer-owned substation equipment shall be operated and maintained by the customer. Support and substation equipment is subject to utility inspection and approval.

222

Optimal Design of Grounding System for HV / EHV Substations in Two Layered Soil  

E-Print Network (OSTI)

Abstract — Successful operation of entire power system depends to a considerable extent on efficient and satisfactory performance of substations. Hence substations in general can be considered as heart of overall power system. In any substation, a well designed grounding plays an important role. Since absence of safe and effective grounding system can result in mal-operation or non-operation of control and protective devices, grounding system design deserves considerable attention for all the substations. Grounding system has to be safe as it is directly concerned with safety of persons working within the substation. Main purpose of this work is designing safe and cost effective grounding systems for HV / EHV substations situated at such locations where soil of the substation site is not uniform. Here soil is considered to be horizontally stratified into two layers. Initially significance of two layered soil model is introduced and design methodology for design of substation grounding system is discussed. Next, two design problems have been solved by using newly developed software and results obtained here are verified with the help of Ground Grid Systems module of ETAP – professional software. Comparison of the results obtained by both the software shows nice agreement of the results given by ESGSD with those obtained from ETAP. Hence this software is found to be quite satisfactory tool in the field of design of grounding system for HV / EHV substations.

unknown authors

223

Alleviations of Substation Congestions by Distributed Generations â An Optimal Location and Reliability Analysis.  

E-Print Network (OSTI)

??With increased load demands from the customers, substation congestion problems have become inevitable to the utility companies. Instead of expanding related system installations to alleviate… (more)

Melvin, Galicia

2011-01-01T23:59:59.000Z

224

Experience in the installation of a microprocessor system for controlling converter units of the Vyborg substation  

Science Journals Connector (OSTI)

The experience in the installation of modern digital systems for controlling converter units at the Vyborg converter substation on the basis of advanced microprocessor devices...

K. B. Gusakovskii; E. Yu. Zmaznov; S. V. Katantsev…

2006-01-01T23:59:59.000Z

225

An Integrative Approach to Reliability Analysis of an IEC 61850 Digital Substation.  

E-Print Network (OSTI)

??In recent years, reliability evaluation of substation automation systems has received a significant attention from the research community. With the advent of the concept of… (more)

Zhang, Yan 1988-

2012-01-01T23:59:59.000Z

226

Assessment of precision timing and real-time data networks for digital substation automation.  

E-Print Network (OSTI)

??This project researched the performance of emerging digital technology for high voltage electricity substations that significantly improves safety for staff and reduces the potential impact… (more)

Ingram, David M.E.

2013-01-01T23:59:59.000Z

227

Design & Implementation of a Universal Communications Processor for Substation Integration, Automation and Protection.  

E-Print Network (OSTI)

??Substation Automation (SA) is a rapidly increasing area of interest in Electrical Engineering these days embracing numerous benefits to utilities. It is clearly the most… (more)

Ozansoy, Cagil Ramadan

2006-01-01T23:59:59.000Z

228

Improving Reliability of IEEE-1588 in Substation Automation Based on Clock Drift Prediction.  

E-Print Network (OSTI)

?? An electric substation is a node in the power grid network. It serves the purpose of transmitting and distributing electric energy from power sources… (more)

Xiao, Yin

2008-01-01T23:59:59.000Z

229

New testing methods and new testing tools for systems utilizing substation communication networks  

Science Journals Connector (OSTI)

The upcoming standard IEC 61850 prepares the ground for the broad application of data communication networks and systems in substations. With the new systems becoming installed,...

F. Steinhauser Dipl.-Ing. Dr. techn.

2003-12-01T23:59:59.000Z

230

Investigation of Wireless LAN for IEC 61850 based Smart Distribution Substations.  

E-Print Network (OSTI)

??The IEC 61850 standard is receiving acceptance worldwide to deploy Ethernet Local Area Networks (LANs) for electrical substations in a smart grid environment. With the… (more)

Parikh, Palak P

2012-01-01T23:59:59.000Z

231

A wireless 802.11 condition monitoring sensor for electrical substation environments.  

E-Print Network (OSTI)

??The work reported in this thesis is concerned with the design, development and testing of a wireless 802.11 condition monitoring sensor for an electrical substation… (more)

Bogias, Alexander

2012-01-01T23:59:59.000Z

232

Implementation of embedded Ethernet based on hardware protocol stack in substation automation system  

Science Journals Connector (OSTI)

Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system (SAS). This paper introduces...

Qiang Ma ? ?; Jianguo Zhao ???; Bingxu Liu ???

2008-04-01T23:59:59.000Z

233

Object Oriented Safety Analysis of an Extra High Voltage Substation Bay  

Science Journals Connector (OSTI)

Experiences of application of the object oriented approach to safety analysis of an extra high voltage substation bay are presented. As the first step...

Bartosz Nowicki; Janusz Górski

1998-01-01T23:59:59.000Z

234

Microsoft Word - CX-HeboSubstationA- FY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Todd Nicholson Supervisory Civil Engineer - TELF-TPP-3 Proposed Action: Hebo Substation Access Road Maintenance Budget Information: Work Order 00270316 PP&A Project No.: 2784...

235

Microsoft Word - CX-Covington_Substation_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2010 8, 2010 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Kerry Cook Project Manager - TELF-TPP-3 Proposed Action: Perform research of groundwater drainage and flooding issues at Covington Complex through the installation of four groundwater monitoring wells PP&A Project No.: PP&A-1772 Budget Information: Work Order #00246440 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B3.6 Siting/ construction/operation/decommissioning of facilities for bench-scale research, conventional laboratory operations, small-scale research and development and pilot projects. Location: Covington Substation in King County, Washington Proposed by: Bonneville Power Administration (BPA)

236

A BOUNDARY ELEMENT FORMULATION FOR THE COMPUTER DESIGN OF SUBSTATION I. Colominas, F. Navarrina, and M. Casteleiro  

E-Print Network (OSTI)

A BOUNDARY ELEMENT FORMULATION FOR THE COMPUTER DESIGN OF SUBSTATION GROUNDING I. Colominas, F approach for the numerical com- putation of substation grounding systems is presented. In this general

Colominas, Ignasi

237

The Fault Diagnosis of Electric Railway Traction Substation with Model-Based Diagnosis of Integration of FDI and DX Approaches  

Science Journals Connector (OSTI)

Most diagnosis systems used in electric railway substation are expert systems based on experiences, which ... applied to diagnose the electric devices in railway substation. The system model knowledge can be obta...

Zhigang Liu; Zhiwei Han; Wei Zhong

2009-01-01T23:59:59.000Z

238

Generalized Bouc-Wen model for highly asymmetric hysteresis  

E-Print Network (OSTI)

interconnected electrical substation equipment. ” PEER Rep.interconnected electrical substation equipment subjected toconnected electrical substation equipment. ” Earthquake Eng.

Song, J; Kiureghian, A D

2006-01-01T23:59:59.000Z

239

Study of the electric field generated by the high voltage substations  

Science Journals Connector (OSTI)

The paper outlines the results of a study regarding the electromagnetic field generated by a 400 kV high voltage (HV) substation belonging to the Romanian national Power Grid Company Transelectrica SA. In the first part of the paper, a semi-analytical ... Keywords: HV substations, computation, electromagnetic field, human exposure, limits

Calin Munteanu; Vasile Topa; Marius Purcar; Laura Grindei; Adina Racasan

2010-10-01T23:59:59.000Z

240

Design and costs estimation of electrical substations based on three-dimensional building blocks  

Science Journals Connector (OSTI)

Substations design is a fundamental engineering component in power network construction. The benefits obtained for having adequate tools and design systems are related mainly to cost savings, reduction of construction problems and faster throughput of ... Keywords: 3D environments, CAD tools, building blocks, electrical substations design

Eduardo Islas Pérez; Jessica Bahena Rada; Jesus Romero Lima; Mirna Molina Marín

2010-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Progress Report of Substation No. 4, Beaumont, Texas, 1909-1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 200 DECEMBER, 1916 = PROGRESS REPORT, SUBSTATION NO. 4, BEAUMONT, TEXAS B. YOUWOBLOOD, DIRECTOR, ' COLLEGE STATION, BRAZOS COUNTY, TEXAS. TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO.... 200 DECEMBER, 191 6 PROGRESS REPORT, SUBSTATION NO. 4, BEAUMONT, TEXAS H. H. LAUDE, B. S., SUPERINTENDENT B. YOUNGBLOOD, DIRECTOR, COLLEGE STATION, BRAZOS COUNTY, TEXAS. - - AUSTIN, TEXAS : VON BOECKMANN- JONES CO., PRINTEBS, 1917...

Laude, H. H. (Hilmer Henry)

1916-01-01T23:59:59.000Z

242

Report of Progress at the Troupe Sub-Station, Smith County Texas.  

E-Print Network (OSTI)

TEXAS AGRICULTUR 146-409-lorn [PERIMENT STATIONS BULLETIN NO. 121 FEBRUARY 1, 1909 REPORT OF PROGRESS AT THE TROUPE SUB-STATION, SMITH COUNTY, TEXAS W. H. HOTCHKISS, SUPERINTENDENT IN CHARGE POSTOFFICE COLLEGE STATION, BRAZOS COUNTY.... ..................................... C. W. CRISLER. .Chief Clerk. .................................. F. R. N~VAILLE. .Stenographer. ...................................... A. S. WARE.. .Stenographer. STATE SUBSTATIONS. ..................... H. H. HARRINGTON, Director. .College...

Hotchkiss, W.S.

1909-01-01T23:59:59.000Z

243

Special design and testing aspects of the 345 kV East Fishkill substation  

SciTech Connect

The installation of two 135 MVAR capacitor banks in the 345 kV East Fishkill substation required special design of the grounding system, installation of reactors in series with the capacitor banks, closing resistors in the circuit breakers and special shielding of control cables. This paper describes the design of the substation and the tests performed before commissioning the capacitor banks.

Fogarty, R.P.; Halleran, T.M.; Laskowski, L.M.; Mark, D.A. (Consolidated Edison Co. of New York, Inc., New York, NY (United States))

1992-10-01T23:59:59.000Z

244

The Functional Design on Fault Recorder of µC / OS-II-based Intelligent Substation  

Science Journals Connector (OSTI)

Regarding the functional requirements for smart substation in fault recorder, this paper introduced µC / OSII, an embedded real-time multitasking operating system as the functional design. The program works with the embedded operating system, the ... Keywords: intelligent substation, fault recorder, embedded operating systems, the ?C / OS-II, state machine

Zhang Yihui; Hu Wenqiang; Liu Shiming; Wang Huabin; Zhang Haiyan

2012-04-01T23:59:59.000Z

245

Abstract--With the deregulation and restructuring of utility industry, many substation automation applications are being  

E-Print Network (OSTI)

1 Abstract--With the deregulation and restructuring of utility industry, many substation automation serves as a handy tool for substation automation related studies. Index Terms--Alternative Transient the deregulation and restructuring of utility industry, it is desirable to introduce more automated functions

246

Integrating modified Delphi method with fuzzy AHP for optimal power substation location selection  

Science Journals Connector (OSTI)

Evaluation and selection of power substation location is an important strategic decision making problem for both public and private sector. The multi-dimensional, multi-criteria nature of the power substation location problem limits the usefulness of any particular single objective model. Studies have shown that electromagnetic radiations emanating from the high voltage lines and substations, pose serious adverse health consequences to living beings. In this study, social, technological, economical, environmental and site characteristics factors and sub criteria, have been derived to make the optimal power substation location selection decision more realistic and effectual. In this paper, an improved and more appropriate power substation location evaluation and selection model has been developed by integrating Modified Delphi method with Fuzzy Analytic Hierarchy Process (FAHP). A numerical example is presented to show applicability and performance of the proposed methodology followed by a sensitivity analysis to discuss and explain the results.

Golam Kabir; M. Ahsan Akhtar Hasin

2013-01-01T23:59:59.000Z

247

Power substation location selection using fuzzy analytic hierarchy process and PROMETHEE: A case study from Bangladesh  

Science Journals Connector (OSTI)

Abstract Electromagnetic radiations emanating from the high voltage lines and substations pose serious adverse health consequences to living beings. As a result, selection of power substation location is an important strategic decision-making problem for both public and private sectors. In general, many conflicting factors affect the appropriate substation location selection problem which adheres to uncertain and imprecise data. In this paper, a simple, systematic and logical scientific approach is structured to evaluate power substation location through integrating Fuzzy Analytical Hierarchy Process (FAHP) with the Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE). The proposed integrated approach provides more realistic and reliable results, and facilitates the decision-maker to handle multiple contradictory decision perspectives through eliminating the limitations of FAHP and PROMETHEE methods. To accredit the proposed model, it is implemented in a power substation location selection problem in Bangladesh.

Golam Kabir; Razia Sultana Sumi

2014-01-01T23:59:59.000Z

248

Laboratory Equipment Donation Program - Equipment Applications  

Office of Scientific and Technical Information (OSTI)

Specific questions concerning equipment should be directed to the point of Specific questions concerning equipment should be directed to the point of contact responsible for the item(s) under consideration. This information is listed on the "Equipment Information" page, as well as on the grant award e-mail sent to the applicant. Step 1: Search and Apply for Equipment Note: If you know the Item Control Number of the equipment you need, you may go directly to the on-line application. Please follow these procedures to "Search Equipment" and apply for equipment using the LEDP Online Application: Select the "Search Equipment" menu link. Enter the type of equipment desired into the search box or choose the "Equipment List" link, which will allow you see a complete list of available equipment. Select the "Item Control Number" for the desired equipment. This

249

Studies of parallelism in distribution networks served by different-source substations  

Science Journals Connector (OSTI)

Despite the fact that the distribution systems usually operate radially, there is the possibility of changing the topology by opening or closing the switching equipment [1]. This change can occur in two situations. In the first one, when one tries to optimize the configuration of the electric network, aiming to achieve lower voltage drop and loss indices, as well an increased reliability. In the second one, when one needs to transfer load from a feeder to another, as result of some contingency or a planned disconnection. In both situations, one has to take into account that multiple switchings in the networks can cause some disconnections for customers, during a short period of time, especially when the feeders are served by different-source substations. These interruptions cause undesirable energy continuity levels for customers, who are more demanding in relation to the electric power supply quality. This context has motivated this paper, whose proposal is the development of a methodology to analyze the technical feasibility of parallelisms in distribution networks by using the Alternative Transient Program (ATP), thus avoiding disconnections for customers. As a result, case studies in AES Sul's concession area, power distribution utility, will be presented.

D.P. Bernardon; L. Comassetto; F.D. Veiga; L.N. Canha

2008-01-01T23:59:59.000Z

250

Conformational Switching between Protein Substates Studied with 2D IR Vibrational Echo Spectroscopy and Molecular Dynamics Simulations  

E-Print Network (OSTI)

Conformational Switching between Protein Substates Studied with 2D IR Vibrational Echo Spectroscopy. Three conformational substates have been identified for the carbonmonoxy form of myoglobin (Mb vibrational echo chemical exchange experiments are used to observed switching between two of these substates

Fayer, Michael D.

251

IEEE TRANSACTIONS ON SPEECH AND AUDIO PROCESSING, VOL. 10, NO. 3, MARCH 2002 137 Substate Tying With Combined Parameter Training  

E-Print Network (OSTI)

IEEE TRANSACTIONS ON SPEECH AND AUDIO PROCESSING, VOL. 10, NO. 3, MARCH 2002 137 Substate Tying. To facilitate tying at the substate level, the state emission proba- bilities are constructed in two stages or exploits Gaussian density sharing and substate tying. Another approach to enhance model training

California at Santa Barbara, University of

252

Daily load profile and monthly power peaks evaluation of the urban substation of the capital of Jordan Amman  

Science Journals Connector (OSTI)

The hourly recorded power of an urban substation of the National Electric Power Company (NEPCO) in the capital of Jordan Amman is used to calculate the diversity and conversion factors of the substation. These factors are used to estimate the daily load power profile and the monthly peak power of the substation. The results show that the conversion factors are almost independent of the number of feeders in the substation, while the diversity factors vary in substations that have six feeders or less. The results show a good correlation between the estimated and actual recorded data of the daily load profile with less than 5% percentage error.

Nabeel I.A. Tawalbeh

2012-01-01T23:59:59.000Z

253

Canby Area Service Project : Substation and Associated Transmission Line : Environmental Assessment.  

SciTech Connect

Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no environmental impact statement'' is not required.

United States. Bonneville Power Administration.

1992-02-01T23:59:59.000Z

254

Canby Area Service Project substation and associated transmission line. Environmental Assessment  

SciTech Connect

Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp`s substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC`s Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC`s substation can accommodate only about 10 percent of the expected additional electric load. BPA`s proposed action is intended to meet SVEC`s increasing electric load. BPA proposes to meet SVEC`s increasing energy load by tapping into BPA`s existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC`s Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ``environmental impact statement`` is not required.

Not Available

1992-02-01T23:59:59.000Z

255

Microsoft Word - Ringold Substation Upgrade CX.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1, 2011 1, 2011 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearence Memorandum Myra Lovell - TELP-TPP-3 Proposed Action: Ringold Substation Structure Replacement Project Budget Information: Work Order # 00272078 Task 03 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021: B4.6 "Additions or modifications to electric power transmission facilities..." Location: Franklin County, Washington - Township 12 North, Range 29 East, Section 26 of the Basin City Quadrangle Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to replace the single pole structure 8/9 of the Benton-Scooteney No. 1 115-kV transmission line, the attached vertically mounted disconnect switch,

256

Microsoft Word - CX-ColumbiaREADaytonSubstationTap_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7, 2011 7, 2011 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Mike Normandeau Customer Account Executive - PSE-SPOKANE Proposed Action: Columbia Rural Electric Association (Columbia REA) Dayton Substation Tap Line Project Budget Information: Work Order 00118303, Task 17 PP&A Project No.: PP&A 2089 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.12: Construction of electric power lines approximately 10 miles in length or less that are not for the integration of major new generation resources into a main transmission system. Location: Dayton, Columbia County, Washington Township 10 North, Range 39 East, Sections 14-17, 20 & 24 Township 10 North, Range 40 East, Sections 19 & 30

257

Microsoft Word - CX-Covington_Substation_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Harvey Schowe Harvey Schowe Project Manager - TESF-CSB-2 Proposed Action: Installation of new water system (potable and fire suppression) to entire Covington Complex PP&A Project No.: PP&A-1601 Budget Information: Work Order # 00257082 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions/modifications to electric power transmission facilities within previously developed area. Location: Covington Substation in King County, Washington Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: In order to provide adequate potable and fire-suppression water to buildings within the Covington Complex, BPA proposes to install approximately 1,500 feet of new potable water line and fire main line. One trench will be dug at a depth of 4-5 feet to carry both new pipes for the

258

HEMP-induced transients in electric power substations. Final report  

SciTech Connect

A nuclear detonation in or above the earth`s atmosphere produces an intense electromagnetic pulse (EMP). A large portion of the EMP electromagnetic energy is within the RF spectrum. A detonation at high altitudes above 40 km produces an EMP called high-altitude EMP (HEMP). HEMP is a steep-front short duration transient with a rise time on the order of a few nanoseconds which decays to near zero in less than a microsecond. A single high-altitude burst can subject much of the continental United States to intense HEMP electric fields on the order of tens of kilovolts per meter. The intense transient HEMP will induce fast transients in high-voltage transmission lines and bus structures, instrumentation cables, and control wires in power transmission and distribution (T & D) substations. A system of traveling wave coupling models for a 500 kV substation, including models for the high voltage primary bus, components (circuit breakers, disconnect switches, power transformers, and current and voltage instrument transformers), low voltage control wiring circuits, and a number of conducted and radiated interference coupling modes, had been developed earlier by EPRI. These EPRI served as the baseline for the present HEMP coupling investigations. The HEMP effects on protective relays were assessed for a nominal HEMP environment using several new field coupling models merged with the switching transient data. It is found that a representative solid state relay is unlikely to be damaged or to misoperate by the nominal HEMP threat with a peak field strength of 50 kV/m. However, it is possible for both DC control wires to flash over to ground simultaneously, causing fuses to blow and placing the relay in an inoperative state.

Wiggins, C.M.; Thomas, D.E.; Salas, T.M. [BDM International, Inc., Albuquerque, NM (United States)

1992-02-01T23:59:59.000Z

259

HEMP-induced transients in electric power substations  

SciTech Connect

A nuclear detonation in or above the earth's atmosphere produces an intense electromagnetic pulse (EMP). A large portion of the EMP electromagnetic energy is within the RF spectrum. A detonation at high altitudes above 40 km produces an EMP called high-altitude EMP (HEMP). HEMP is a steep-front short duration transient with a rise time on the order of a few nanoseconds which decays to near zero in less than a microsecond. A single high-altitude burst can subject much of the continental United States to intense HEMP electric fields on the order of tens of kilovolts per meter. The intense transient HEMP will induce fast transients in high-voltage transmission lines and bus structures, instrumentation cables, and control wires in power transmission and distribution (T D) substations. A system of traveling wave coupling models for a 500 kV substation, including models for the high voltage primary bus, components (circuit breakers, disconnect switches, power transformers, and current and voltage instrument transformers), low voltage control wiring circuits, and a number of conducted and radiated interference coupling modes, had been developed earlier by EPRI. These EPRI served as the baseline for the present HEMP coupling investigations. The HEMP effects on protective relays were assessed for a nominal HEMP environment using several new field coupling models merged with the switching transient data. It is found that a representative solid state relay is unlikely to be damaged or to misoperate by the nominal HEMP threat with a peak field strength of 50 kV/m. However, it is possible for both DC control wires to flash over to ground simultaneously, causing fuses to blow and placing the relay in an inoperative state.

Wiggins, C.M.; Thomas, D.E.; Salas, T.M. (BDM International, Inc., Albuquerque, NM (United States))

1992-02-01T23:59:59.000Z

260

Categorical Exclusion (CX) Determination Proposed Action: Expansion of O'Fallon Creek Substation Yard  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Expansion of O'Fallon Creek Substation Yard Expansion of O'Fallon Creek Substation Yard Description of Proposed Action: The Western Area Power Administration (Western) is proposing to expand the current yard to accommodate an additional bay for a dedicated electrical feed to a future oil pumping station that will be part of the Keystone XL project. Number and Title of Categorical Exclusions Being Applied: 10 CFR 10210410 Subpmi D, Appendix B, B4.11: Construction of electric power substations ... or modification of existing substations and support facilities. Regulatory Requirements for CX Determination: The DOE Guidelines for Compliance with the Regulatory Requirements for the National Environmental Policy Act at 10 CFR 1021AI0(b), require the following determinations be made in order for a proposed action to be categorically

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Generalized charge simulation method for the calculation of the electric field in high voltage substations  

Science Journals Connector (OSTI)

This paper deals with the calculation of the electric field strength in high voltage (HV) substations comprising complex geometrical structures. Generalized charge simulation ... is to examine the influence of to...

Aleksandar Rankovi?; Milan S. Savi?

2010-07-01T23:59:59.000Z

262

A methodology for performance and compatibility evaluation of an all-digital substation protection system  

E-Print Network (OSTI)

whether to operate associated circuit breaker(s). Existing protection systems within a substation are based on a hardwired interface between instrument transformers and protective relays. Recent development of electronic instrument transformers...

Portillo Urdaneta, Levi

2007-04-25T23:59:59.000Z

263

Synchrophasor Measurement Using Substation Intelligent Electronic Devices: Algorithms and Test Methodology  

E-Print Network (OSTI)

This dissertation studies the performance of synchrophasor measurement obtained using substation Intelligent Electronic Devices (IEDs) and proposes new algorithms and test methodology to improve and verify their performance when used in power system...

Ren, Jinfeng

2012-02-14T23:59:59.000Z

264

An Integrative Approach to Reliability Analysis of an IEC 61850 Digital Substation  

E-Print Network (OSTI)

In recent years, reliability evaluation of substation automation systems has received a significant attention from the research community. With the advent of the concept of smart grid, there is a growing trend to integrate more computation...

Zhang, Yan 1988-

2012-11-28T23:59:59.000Z

265

Study on integrated automation system of traction substation for express railway lines  

Science Journals Connector (OSTI)

The structure and function of integrated automation system of traction substation for express electric railway lines developed by our university are discussed in this paper. The paper mainly describes the function installation of monitoring and communication ...

Gao Shibin; Chen Xiaochuan; Wang Qian; Wang Ren; Chen Weirong; Xiong Liebin

2002-11-01T23:59:59.000Z

266

EPON’s Research on Transmission of Sampling Value in Process Level of Digital Substation  

Science Journals Connector (OSTI)

Non-conventional instrument transformers and optical fiber communication are utilized in secondary system of digital substation. Sampling value signals are transmitted to Merging ... Finally, the deployment of EP...

Qiu Ming-yi; Xu Xi-dong

2013-01-01T23:59:59.000Z

267

Modelling and analysis of protection and control applications in smart substation  

Science Journals Connector (OSTI)

The real-time transaction processing was a key and challenging technology to protect systems from various failures in smart substation. This paper introduces the time critical communication between the protection and control devices and the primary apparatuses in three-level communication network architecture based on IEC61850, and analyses the process of information exchange and delay requirement of Protection and Control (P&C) applications between level and level, bay and bay, station and station in smart substation. The generic model of the P&C applications was modelling by latency requirement on OPNET, then the simulation and discussion on using those models to construct IEC61850 network validated the real-time of the application model. In the meantime, the delay performance of the P&C application is analysed in scenarios multiple services sharing substation network, which is an attempt to discuss the possibility of establishing a smart substation network simulation platform on OPNET.

Xingyong Yu; Jiang Yu; Jun Chang

2014-01-01T23:59:59.000Z

268

A simple approach to improve lightning performance of an uprated substation  

SciTech Connect

This paper presents a simple method to minimize lightning surges entering an uprated or compact substation. A severe lightning stress is caused by a backflashover in close proximity to the substation. Feasibility of uprating is based on the surge arrester technology available at present. However, some aspects of line design offer opportunities in reducing frequency and severity of lightning surges imposed on the substation. The tower surge response adds an inductive overshoot only during the front of the stroke which reduces considerably during the tail. If backflashover does not occur before reflections from adjacent towers arrive, it is unlikely to occur at all. Use of guys and underbuilt ground wires in the limiting distance will produce reflections with larger magnitude and reduce the effective surge impedance of the tower. This would not only reduce backflashover frequency but will also minimize crest and duration of surges entering the substation.

Harrington, R.J.; Mueen, M. [George Washington Univ., Washington, DC (United States). Dept. of Electrical Engineering and Computer Science] [George Washington Univ., Washington, DC (United States). Dept. of Electrical Engineering and Computer Science

1996-07-01T23:59:59.000Z

269

An Adaptive Fast Multipole Higher Order Boundary Element Method for Power Frequency Electric Field of Substation  

Science Journals Connector (OSTI)

An adaptive fast multipole higher order boundary element method combining fast multipole (FM) with a higher order boundary element method is studied to solve the power frequency electric field (PFEF) of substations. In this new technique, the iterative equation solver GMRES is used in the FM, where matrix-vector multiplications are calculated using fast multipole expansions. The coefficients in the preconditioner for GMRES are stored and are used repeatedly in the direct evaluations of the near-field contributions. Then a 500kV outdoor substation is modeled and the PFEF of the substation is analyzed by the novel algorithm and other conventional methods. The results show that, in computational cost and the storages capability aspects, the algorithm proposed in this study has obvious advantages. It is suitable for the calculation of the large-scale PFEF in complex substations and the design of electromagnetic compatibility.

Zhang Zhan-Long; Deng Jun; Xiao Dong-Ping; He Wei; Tang Ju

2010-01-01T23:59:59.000Z

270

THURSDAY: Deputy Secretary of Energy to Visit Western Area Power Administration Transmission Substation  

Energy.gov (U.S. Department of Energy (DOE))

Deputy Secretary of Energy Elizabeth Sherwood-Randall will visit the Western Area Power Administration for a ceremony at the Electrical District No. 5 Substation to view progress on the Electrical District 5-to-Palo Verde transmission project.

271

A probabilistic method for establishing the transformer capacity reserve criteria for HV/MV substations  

SciTech Connect

This paper provides an extension of methods for computing reliability indices for substations which takes into account the permissible overload of the power transformer, the daily load cycle and emergency loading. Based on the reliability indices derived in this paper it is possible to determine a reliability criterion for the rating of the substation, the number of transformers and the reserve factor required, which have traditionally been based on conservative deterministic criteria.

Elmakis, D.; Braunstein, A.; Naot, Y.

1986-11-01T23:59:59.000Z

272

Report of Progress with Citrus Fruits at the Beeville Sub-Station, Bee County.  

E-Print Network (OSTI)

65-109-5m TEXAS AGRICULTURAL EXPERIMENT STATIONS. -T- I . ! '? . ........ ?' ? r ; 'V ? J 'V ? ? ? BULLETIN NO. 118. February, 1 9 0 9 . REPORT Of PROGRESS WITH CITRUS FRUITS AT THE BEEVILLE SUB-STATION, BEE COUNTY S. A. WASCHKA................. ................................Stenographer. A. S. F IB5 mmmmmmmmmmmmmmmmmmmmmmmmmmmmm mmmmmmmmmmmmmmm STATE SUBSTATIONS. H. H. R IBBC8 -1X8 mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmDirector. W. S. R X1uoMCPP0 Superintendent...

Waschka, S. A.

1909-01-01T23:59:59.000Z

273

Cotton Variety Experiments, 1912-1920, Substation No. 7, Spur, Texas.  

E-Print Network (OSTI)

TEXAS A6RICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, President BULLETIN NO. 288 FEBRUARY, 1922 DIVISION OF COTTON BREEDING COTTON VARIETY EXPERIMENTS, 1912-1920, SUBSTATION NO. 7, SPUR, TEXAS B..., Sorl Survegor H. V. GEIB, B. S., Soil Surveyor FEED CONTROL SERVICE B YOUNGBLOOD Ph D Director F.' D. FULLER, M. s.; ~xicf Inspecfor S. D. PEARCE, Inspector J. H. ROGERS, Inspecfor W. H. WOOD, Inspector SUBSTATIONS l%. 'l. Beeville Bee County...

Freeman, George Fouche; Dickson, R. E

1922-01-01T23:59:59.000Z

274

Progress Report of Substation No. 3, Angleton, Texas, 1909-1914.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 197 NOVEMBER, 1916 PROGRESS REPORT OF SUBSTATION NO. 3, ANGLETON, TEXAS POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY, TEXAS. +sB AUSTIN, TEXAS : VON BOECKMANN-JONES CO., PRINTERS, 1916.... [Blank Page in Original Bulletin] TEXAS A(;RICULTURAl, EXPERIMENT STATION BULLETIN NO. 197 NOVEMBER, 1916 PROGRESS REPORT OF SUBSTATION NO. 3, ANGLETON, TEXAS N. E. WINTERS, B. S., SUPERINTENDENT POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY, TEXAS...

Winters, N. E. (Nathaniel Elmer)

1916-01-01T23:59:59.000Z

275

Progress Report, Texas Substation No. 6, Denton, Texas, 1909-14.  

E-Print Network (OSTI)

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 199 DECEMBER, 1916 PROGRESS REPORT, TEXAS SUBSTATION NO. 6, DENTON, TEXAS POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY, TEXAS. - AUSTIN, TEXAS : VON BOECKMANN-JONES CO., PRINTERS, 1916.... [Blank Page in Original Bulletin] TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 199 DECEMBER, 1916 PROGRESS REPORT, TEXAS SUBSTATION NO. 6, DENTON, TEXAS V. L. CORY, B. S. . SUPERINTENDENT , . POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY...

Cory, V. L. (Vivian L.)

1916-01-01T23:59:59.000Z

276

Impact of electric vehicles on distribution substations: A Swiss case study  

Science Journals Connector (OSTI)

Abstract An increasing number of electric vehicles (EVs) will have a significant impact on the electricity grids. For target grid planning, it is essential to identify and quantify this impact in terms of local infrastructure overloads. We study the impact of EV charging loads on Swiss distribution substations under different penetration levels and pricing regimes. Unlike mainly conceptual studies focusing on generic distribution grids, we use real data—driving profiles matched to regional circumstances, Swiss substation capacity and load data in the high-voltage grid together with electricity prices—as the main data inputs. To reflect current regulation and contracting schemes, we apply decentral decision-making instead of central control. The results indicate that under a flat electricity tariff and EV penetration levels around 16% the current substation capacity will be sufficient to cover additional EV charging load. However, beyond penetration levels of 50% an increasing number of substations will be overloaded. More significantly, the introduction of dynamic electricity prices can further increase the risk of substation overloads. These results show that EV charging loads can also cause bottlenecks on substations in the high-voltage grid.

Florian Salah; Jens P. Ilg; Christoph M. Flath; Hauke Basse; Clemens van Dinther

2015-01-01T23:59:59.000Z

277

Electrical substation service-area estimation using Cellular Automata: An initial report  

SciTech Connect

The service areas for electric power substations can be estimated using a Cellular Automata (CA) model. The CA model is a discrete, iterative process whereby substations acquire service area by claiming neighboring cells. The service area expands from a substation until a neighboring substation service area is met or the substation`s total capacity or other constraints are reached. The CA-model output is dependent on the rule set that defines cell interactions. The rule set is based on a hierarchy of quantitative metrics that represent real-world factors such as land use and population density. Together, the metrics determine the rate of cell acquisition and the upper bound for service area size. Assessing the CA-model accuracy requires comparisons to actual service areas. These actual service areas can be extracted from distribution maps. Quantitative assessment of the CA-model accuracy can be accomplished by a number of methods. Some are as simple as finding the percentage of cells predicted correctly, while others assess a penalty based on the distance from an incorrectly predicted cell to its correct service area. This is an initial report of a work in progress.

Fenwick, J.W.; Dowell, L.J.

1998-07-01T23:59:59.000Z

278

Fault diagnosis of electric railway traction substation with model-based relation guiding algorithm  

Science Journals Connector (OSTI)

Abstract Most diagnosis systems used in electric railway traction substation are expert systems based on experience, which cannot diagnose faults beyond experience and are very difficult for transplantation and maintenance. In this paper, the model-based diagnosis (MBD) with integration reasoning is firstly used for fault diagnosis of electric railway traction substation. Aiming at the structural characteristics and actual demands of traction substation, we propose a detailed application plan. Rules for element and system models are established. In addition, we propose a relation guiding algorithm (RGA) for searching candidates of minimal conflict set, in which the hidden messages of analytical redundancy relations can be made full use of and the searching space is reduced further. Taking the autotransformer (AT) traction substation in Hefei–Nanjing Passenger Link of China Railway as an example, we construct models for different device objects, and give the descriptions of system model in traction substation. Based on a sequence of fault observations, the fault diagnosis is tested with the proposed plan. The diagnosis result shows that the application plan with MBD and integration reasoning is feasible and effective for traction substation.

Zhigang Liu; Zhiwei Han

2014-01-01T23:59:59.000Z

279

AC Transit  

Energy.gov (U.S. Department of Energy (DOE))

AC Transit (or the Alameda-Contra Costa Transit District) is based in Oakland, California, and provides transportation services to the East Bay of San Francisco. The 360-square-mile service area includes 13 cities and adjacent unincorporated areas in Alameda and Contra Costa counties. AC Transit's approximately 638 vehicles serve more than 65 million annual passengers.

280

User Electrical Equipment Inspections  

NLE Websites -- All DOE Office Websites (Extended Search)

User Electronic and Electrical Equipment Inspection Criteria In order to be in compliance with NEC, OSHA, and DOE regulations all electronic and electrical equipment at the APS...

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

AC Electrostatic Field Study : Final Report.  

SciTech Connect

The phenomenon of fast transients propagating to the outer sheath of a gas insulated substation (GIS) during switching and disconnect operations as well as the distortion of the electric field gradient around an electric transmission line in the presence of field measuring equipment are examples of electrostatic and electromagnetic field problems that are very much on the minds of both power engineers and maintenance personnel alike. Maintenance personnel working on high voltage equipment want to know the areas that have the highest electric field strength gradients and they want to reduce the risk of being shocked when touching a conventionally 60 Hz grounded GIS enclosure due to fast transients initiated by faults and switching operations. In studying these phenomena during the performance period of this grant, tower configurations for the electric field strength gradient measurements were tested with the ESURF3D program acquired from BPA and gas insulated substation test pole (GISTP) models were tested using the Alternative Transients Program (ATP) version Electromagnets Transients Program (EMTP). The results of these two modeling paradigms are presented in this report not as the last word on these subjects, but as a couple of the many ways one can approach two classical electromagnetic waves problems. 19 refs., 13 figs., 3 tabs.

Lebby, Gary L.

1990-08-28T23:59:59.000Z

282

Development of an embedded system actuator node for intergration into an IEC 61850 based substation automation application.  

E-Print Network (OSTI)

??The introduction of the IEC 61850 standard in substations for communication networks and systems by the International Electrotechnical Commission (IEC) in 2003 provided the possibility… (more)

Retonda-Modiya, John-Charly

2012-01-01T23:59:59.000Z

283

University of Delaware | CCEI Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

CCEI Equipment Click column headings to sort Type Equipment Details Institution Type Equipment Details Institution: Lab Lab BACK TO TOP...

284

Conformational Diversity and Sub-states in Enzyme Catalysis | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Conformational Diversity and Sub-states in Enzyme Catalysis Conformational Diversity and Sub-states in Enzyme Catalysis November 01, 2013 Enzymes are great biocatalysts, and have attracted significant interest for industrial applications (including cellulosic ethanol) due to their remarkable catalytic efficiencies. The understanding of factors that enable enzymes to achieve the high catalytic efficiency will have large impact through design of new and powerful biocatalysts. Unfortunately, the understanding of these factors have largely remain a mystery so far. Using joint computational-experimental methodology we have developed a unique technique named quasi-anharmonic analysis (QAA) for identification of conformational diversity and conformational sub-states associated with enzyme function. As a result of this approach we have been able to develop

285

EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild Project, Grand County, CO EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild Project, Grand County, CO Summary Western Area Power Administration prepared an EIS, with the U.S. Forest Service, Bureau of Land Management, and Grand County (Colorado) as cooperating agencies, to evaluate the potential environmental impacts of rebuilding a 12-mile, 69-kV electric transmission line in Grand County. The proposed project would rebuild the single-circuit line as a double-circuit transmission line and add a second power transformer. Western identified potentially significant impacts while preparing an EA for this proposal (DOE/EA-1520) and prepared an EIS instead of completing

286

EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

00: Granby Pumping Plant Switchyard-Windy Gap Substation 00: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild Project, Grand County, CO EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild Project, Grand County, CO Summary Western Area Power Administration prepared an EIS, with the U.S. Forest Service, Bureau of Land Management, and Grand County (Colorado) as cooperating agencies, to evaluate the potential environmental impacts of rebuilding a 12-mile, 69-kV electric transmission line in Grand County. The proposed project would rebuild the single-circuit line as a double-circuit transmission line and add a second power transformer. Western identified potentially significant impacts while preparing an EA for this proposal (DOE/EA-1520) and prepared an EIS instead of completing

287

Microsoft Word - CX-Marion and Sand Springs Substation Towers Revised.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

KEC-4 KEC-4 SUBJECT: Environmental Clearance Memorandum Dave Tripp Project Manager - TEP-CSB-1 Proposed Action: Marion and Sand Springs Substations Radio Tower Projects Budget Information: Work Orders 00243411 and 00243190; Task 3 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.19 Siting, construction, and operation of microwave and radio communication towers and associated facilities... Location: Marion and Deschutes counties, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to install new radio towers at the Marion Substation and Sand Springs Substation communication sites in Oregon. BPA must vacate radio frequencies in the 1710-1755MHz band to comply with a Federal law mandating reallocation of

288

Control of offshore marine substation for grid-connection of a wave power farm  

Science Journals Connector (OSTI)

Abstract To grid-connect an offshore wave power farm, an intermediate marine substation is suggested. As a part of the Uppsala University wave power project, a marine substation has been designed, assembled and deployed at sea. The substation is capable of connecting up to seven wave energy converters (WECs), and to transfer the power to the onshore 1 kV-grid. In this article, the control procedure for grid connection of the \\{WECs\\} is described step-by-step, and the practical implementations are presented. The system is designed with autonomous control and will connect or disconnect the WECs, depending on the sea state. Fault handling is taken into account, and grid power quality such as harmonic distortion and flicker are considered in the design. Experimental results are presented to verify the system functionalities.

Rickard Ekström; Mats Leijon

2014-01-01T23:59:59.000Z

289

Design of active loops for magnetic field mitigation in MV/LV substation surroundings  

Science Journals Connector (OSTI)

Abstract This paper deals with the application and optimization of active loops for the mitigation of the magnetic field generated by complex sources, especially MV/LV substations. Various active-loop configurations are proposed, which are analyzed in several regions located close to a particular MV/LV substation, and the optimum geometry and location of the loops are obtained together with the optimum current (magnitude and phase) to be injected into the loops. All this is performed by means of a genetic algorithm in order to reduce the average magnetic field inside the target volume (inspection volume) to the minimum. The performance of the proposed active loops is compared with that obtained via other well-known mitigation technique, such as conductive/ferromagnetic passive shields. The main results are analyzed, and the differences, in terms of performance, between the two shielding techniques, and their proper application to MV/LV substations, are highlighted.

Juan Carlos del-Pino-López; Luca Giaccone; Aldo Canova; Pedro Cruz-Romero

2015-01-01T23:59:59.000Z

290

Power Evaluation of Jakarta DC Railway Substation to Meet 1.2 Million Passengers Per Day  

Science Journals Connector (OSTI)

Abstract Jakarta is a metropolitan city that continues to strive to develop the capacity of its mass transport as other large cities in the world, primarily the development of the rail-based transportation. Indonesia Railway Company (PT Kereta Api (Persero)) had forecasted that there will be 1.2 million passengers per day on Jakarta in 2019. To meet these targets, it is necessary to adequate the infrastructure planning, especially the capacity of the DC substations which supply the electric power to the trains. This paper will demonstrate the strategy used to determine the point of placement of new DC substation and/or existing DC substation upgrades throughout the Jakarta area from 2013 to 2019. The current railway timetable and the future pattern of railway operation plan are used to predict the possibilities of peak load spots along the track.

Yanuarsyah Haroen; Tri Desmana Rachmildha; M. Ikhsan; M. Ivan Fikriadi

2013-01-01T23:59:59.000Z

291

Integrating fuzzy AHP with TOPSIS method for optimal power substation location selection  

Science Journals Connector (OSTI)

Electromagnetic radiations emanating from the high voltage lines and substations pose serious adverse health consequences to living beings. As a result, evaluation and selection of power substation location is an important strategic decision making problem for both public and private sector. In this paper, fuzzy analytic hierarchy process (FAHP) has been integrated with technique for order preference by similarity to an ideal solution (TOPSIS) method to develop an improved and more appropriate power substation location evaluation and selection model considering social, technological, economical, environmental and site characteristics factors and sub criteria. The proposed decision-making approach takes advantage of the synergy between these two well-known multi-criteria analysis (MCA) methods. A numerical example is presented to show applicability and performance of the proposed methodology followed by a sensitivity analysis to discuss and explain the results.

Golam Kabir; M. Ahsan Akhtar Hasin

2013-01-01T23:59:59.000Z

292

Microsoft Word - Chenoweth-Substation-3G-RS-CX.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4, 2010 4, 2010 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Creig Millen Project Manager - TEC-CSB-1 Proposed Action: Chenoweth Substation 3G Radio Station Project Budget Information: Work Order 00197213, Task 03 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.19 Siting, construction, and operation of microwave and radio communication towers and associated facilities... Location: Wasco County, Oregon (T2N, R13E, Sections 21and 28) Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to construct a 120-foot radio tower and antenna system at BPA's Chenoweth Substation in Wasco County, Oregon. The new tower will require a 20 x 20 foot expansion of the existing substation yard and will replace an existing 50-foot monopole

293

Study on Tubular Busbar Corona Design Optimization of ±660kV HVDC Converter Substation in Qingdao  

Science Journals Connector (OSTI)

The HVDC busbar corona characteristic is the main factor taken into account for choosing busbar of HVDC converter substation. By establishing the calculation models of electric field strength along the busbar surface, ground total electric field strength ... Keywords: ±660 kV HVDC, converter substation, corona characteristics, electromagnetic, tubular busbar optimization

Xu Mingming; Li Kejun; Tan Zhenyu; Niu Lin

2010-06-01T23:59:59.000Z

294

Agricultural Equipment | Open Energy Information  

Open Energy Info (EERE)

Equipment Incentives Retrieved from "http:en.openei.orgwindex.php?titleAgriculturalEquipment&oldid267143...

295

Substations reliability-centered maintenance and predictive maintenance - a strategic partnership  

SciTech Connect

A maintenance optimization study for substation components can be most effective when Reliability Centered Maintenance (RCM) Analysis is combined with a Predictive Maintenance (PDM) Assessment. If the two processes are performed concurrently, the benefit-to-cost ratios for each is increased. Also, the cost of implementing RCM recommendations for condition monitoring can be minimized, while maximizing their impact at the same time. This paper presents the essential elements of both the RCM and PDM processes, and describes how they work together in a substation environment as a comprehensive maintenance assessment tool. Descriptions of recent experiences are also included.

Colsher, R.J. [Electric Power Research Institute, Eddystone, PA (United States); Abbott, P.D.; Matusheski, R.L. [EPRI & MD Center, Eddystone, PA (United States); Smith, S.B. [ERIN Engineering & Research, Walnut Creek, CA (United States)

1996-08-01T23:59:59.000Z

296

Energy Audit Equipment  

E-Print Network (OSTI)

The tools (equipment) needed to perform an energy audit include those items which assist the auditor in measuring the energy used by equipment or lost in inefficiency. Each tool is designed for a specific measurement. They can be inexpensive simple...

Phillips, J.

2012-01-01T23:59:59.000Z

297

You will be hired in our Local Business Unit Substations (Power Systems Division) and, in the role of Service Sales Specialist, you will drive the  

E-Print Network (OSTI)

You will be hired in our Local Business Unit Substations (Power Systems Division) and, in the role and profitability targets for Substations Systems Your contact: Veronica Meloni, Talent Acquisition Department professionals. Requirements You have at least 2 or 3 years experience in the Substations segment and you have

Segatti, Antonio

298

Structural Assignments and Dynamics of the A Substates of MbCO: Spectrally Resolved Vibrational Echo Experiments and Molecular Dynamics Simulations  

E-Print Network (OSTI)

Structural Assignments and Dynamics of the A Substates of MbCO: Spectrally Resolved Vibrational of the A1 and A3 spectroscopic substates in the IR spectrum of the carbon monoxide (CO) stretch of carbonmonoxymyoglobin (MbCO). The measured dephasing dynamics of these substates is compared to the dephasing dynamics

Fayer, Michael D.

299

Structure, Vol. 10, 5160, January, 2002, 2002 Elsevier Science Ltd. All rights reserved. PII S0969-2126(01)00699-2 Probing Substates in Sperm Whale Myoglobin  

E-Print Network (OSTI)

-2126(01)00699-2 Probing Substates in Sperm Whale Myoglobin Using High-Pressure Crystallography that protein crystals do in the populations of conforma- tional substates. Furthermore, a novel high-pressure temperatures. Unlike in flash in the conformation of groups of atoms may be described by a simple isotropic expansion or com-mational substates

Phillips, George N. Jr.

300

A hybrid intelligent system for alarm processing in power distribution substations  

Science Journals Connector (OSTI)

This application paper presents an intelligent system for alarm processing and fault location in power substations. A hybrid model is constructed using rule-based systems and an artificial neural network. Incoming alarms are initially handled by an input ... Keywords: Expert systems, fault location, neural networks

J. C. Stacchini de Souza; M. B. Do Coutto Filho; R. S. Freund

2010-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Level 1 Accident Report of the March 1, 2010 Bobcat Fatality at BPA's White Bluffs Substation  

Energy.gov (U.S. Department of Energy (DOE))

On March 2, 2010 at the request of the Bonneville Power Administration (BPA) Chief Safety Officer, a Level I Accident Investigation was convened to investigate an accident in which a supplemental labor contractor was fatally injured in a Bobcat/backhoe accident at the White Bluffs Substation near Richland, Washington on March 1, 2010.

302

Puget Sound Area Electric Reliability Plan : Supplemental Environmental Analysis, Schultz Substation.  

SciTech Connect

This document describes the purpose, function, and the environmental consequences of the proposed Schultz substation near Ellensburg, Washington. The affected environment is described in detail, including aerial survey photographs. The impacts on vegetation, fish and wildlife, soils, and water resources are described. (GHH)

United States. Bonneville Power Administration.

1992-04-01T23:59:59.000Z

303

Implementation of superconducting fault current limiter for flexible operation in the power substation  

Science Journals Connector (OSTI)

Abstract The concentration of large-scale power loads located in the metropolitan areas have resulted in high fault current levels during a fault thereby requiring the substation to operate in the double busbar configuration mode. However, the double busbar configuration mode results in deterioration of power system reliability and unbalanced power flow in the adjacent transmission lines which may result in issues such as overloading of lines. This paper proposes the implementation of the superconducting fault current limiter (SFCL) to be installed between the two substation busbars for a more efficient and flexible operation of the substation enabling both single and double busbar configurations depending on the system conditions for guaranteeing power system reliability as well as fault current limitations. Case studies are being performed for the effectiveness of the SFCL installation and results are compared for the cases where the substation is operating in single and double busbar mode and with and without the installation of the SFCL for fault current mitigation.

Chong Suk Song; Hansang Lee; Yoon-sung Cho; Jaewan Suh; Gilsoo Jang

2014-01-01T23:59:59.000Z

304

The Design of Substation Avalanche Test System Based on B Code  

Science Journals Connector (OSTI)

This paper describes a substation avalanche test system which is based on B code. The system supports simultaneous operation of multiple remote signaling and can ensure the synchronization and accuracy of time's movement. Using platform of ARM9 hardware ... Keywords: B code, time synchronization system, avalanche tested, embedded operating system

Guo Ying, Liu Nan

2013-11-01T23:59:59.000Z

305

Electric Equipment of the Dolomites Railway  

Science Journals Connector (OSTI)

... current at 2700 volts is adopted. This is done by the use of only one substation situated near Cortina, a little more than half-way from the power terminus. The ... the power terminus. The conversion of the alternating to direct current is done at the substation by means of two mercury arc rectifiers each of 11,000 kilowatts capacity at 3000 ...

1932-01-02T23:59:59.000Z

306

Data:7f76b69f-a1ac-4852-80bf-704131ee961c | Open Energy Information  

Open Energy Info (EERE)

b69f-a1ac-4852-80bf-704131ee961c b69f-a1ac-4852-80bf-704131ee961c No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Algoma Utility Comm Effective date: 2008/05/28 End date if known: Rate name: Large Power Time-of-Day Service more than 200kW - Primary Metering Discount Sector: Industrial Description: Application: This rate will be applied to customers for all types of service, if their monthly Maximum Measured Demand is in excess of 200 kilowatts (kW) per month for three or more months in a consecutive 12-month period, but not greater than 700 kW per month for three or more months in a consecutive 12-month period. Commitment to Community Program Rider Under provisions of 1999 Wisconsin Act 9 and 2005 Wisconsin Act 141, a municipal electric utility shall charge each customer a low-income assistance and energy efficiency fee. Fifty percent of the fees charged by the municipal utility shall be used for low-income assistance programs and the remainder will be used for energy efficiency programs. Low-income programs may include assistance to low-income households for weatherization and other energy conservation services, payment of energy bills or early identification or prevention of energy crises. Energy efficiency programs may include those programs designed to reduce the demand for natural gas or electricity or improving the efficiency of its use during any period. Cp-1 Small Power Service $7.50 per customer per month. Pricing Periods: On-peak: 7:00 a.m. to 9:00 p.m., prevailing time, Monday through Friday, excluding holidays, specified below. Off-peak: All times not specified as on-peak, including all day Saturday and Sunday, and the following holidays: New Year's Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, and Christmas Day, or the day nationally designated to be celebrated as such. Discounts: The monthly bill for service will be subject to the following discounts applied in the sequence listed below. Primary Metering Discount: Customers metered on the primary side of the transformer shall be given a 2.00 percent discount on the monthly energy charge, distribution demand charge, and demand charge. The PCAC and the monthly customer charge will not be eligible for the primary metering discount. Transformer Ownership Discount: Customers who own and maintain their own transformers or substations shall be given a credit of $0.40 per kW of distribution demand. Customer-owned substation equipment shall be operated and maintained by the customer. Support and substation equipment is subject to utility inspection and approval.

307

Data:9c865c82-c3eb-4ac7-80b6-3a575a88f325 | Open Energy Information  

Open Energy Info (EERE)

65c82-c3eb-4ac7-80b6-3a575a88f325 65c82-c3eb-4ac7-80b6-3a575a88f325 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Algoma Utility Comm Effective date: 2008/05/28 End date if known: Rate name: Industrial Power Time-of-Day Service more than 700kW - Primary Metering and Transformer Ownership Discount Sector: Industrial Description: Application: This rate will be applied to customers for all types of service if their monthly Maximum Measured Demand is in excess of 700 kilowatts (kW) per month for three or more months in a consecutive 12-month period.Commitment to Community Program Rider Under provisions of 1999 Wisconsin Act 9 and 2005 Wisconsin Act 141, a municipal electric utility shall charge each customer a low-income assistance and energy efficiency fee. Fifty percent of the fees charged by the municipal utility shall be used for low-income assistance programs and the remainder will be used for energy efficiency programs. Low-income programs may include assistance to low-income households for weatherization and other energy conservation services, payment of energy bills or early identification or prevention of energy crises. Energy efficiency programs may include those programs designed to reduce the demand for natural gas or electricity or improving the efficiency of its use during any period. Cp-1 Small Power Service $7.50 per customer per month. Pricing Periods: On-peak: 7:00 a.m. to 9:00 p.m., prevailing time, Monday through Friday, excluding holidays, specified below. Off-peak: All times not specified as on-peak, including all day Saturday and Sunday, and the following holidays: New Year's Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, and Christmas Day, or the day nationally designated to be celebrated as such. Discounts: The monthly bill for service will be subject to the following discounts applied in the sequence listed below. Primary Metering Discount: Customers metered on the primary side of the transformer shall be given a 2.00 percent discount on the monthly energy charge, distribution demand charge, and demand charge. The PCAC and the monthly customer charge will not be eligible for the primary metering discount. Transformer Ownership Discount: Customers who own and maintain their own transformers or substations shall be given a credit of $0.40 per kW of distribution demand. Customer-owned substation equipment shall be operated and maintained by the customer. Support and substation equipment is subject to utility inspection and approval.

308

Laboratory Equipment Donation Program - Equipment List  

Office of Scientific and Technical Information (OSTI)

Equipment List Equipment List Already know the item control number? Submit Reset Item Control Number Equipment Name Date Entered Condition Picture 89022833290004 1300594 TLD DETECTOR 12/16/2013 Repairable N/A 89022833290005 1300595 PICOMETER 12/16/2013 Repairable N/A 89022833290008 1300598 READER 12/16/2013 Repairable N/A 89022833290010 1300600 DETECTOR VACUUM PUMP 12/16/2013 Repairable N/A 89022833290016 1300606 TLD READER 12/16/2013 Repairable N/A 89022833290018 1300608 READER 12/16/2013 Repairable N/A 89022833290019 1300609 ANALYZER WITH DETECTOR 12/16/2013 Repairable N/A 89022833180013 1300993 PRESSURE REGULATOR 12/04/2013 Repairable N/A 89022833180022 1301098 VACUUM GAUGE 12/04/2013 Repairable N/A 89022833180023 1301099 OSCILLOSCOPE 12/04/2013 Repairable N/A

309

Categorical Exclusion (CX) Determination Proposed Action: Elliot 115kV/43.8kV Transmission Substation Construction and Elliot  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Elliot 115kV/43.8kV Transmission Substation Construction and Elliot Elliot 115kV/43.8kV Transmission Substation Construction and Elliot 43.8kV Transmission Line. Description of Proposed Action: The Central Power Electric Cooperative (Central Power) is proposing a new substation near Elliot, ND to be owned and operated by Western under Western's Valley City to Forman 115kV transmission line in addition to 8 miles of new 43.8kV transmission line to connect the new substation to Dakota Valley Electric's (a Central Power member) North Milnor substation. Number and Title of Categorical Exclusions Being Applied: 10 CFR 1021.410 Subpart D, Appendix B, B4.l1: Construction of electric power substations ... or modification of existing substations and support facilities. Regulatory Requirements for CX Determination: The DOE Guidelines for Compliance with

310

Electric Vehicle Supply Equipment  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Procurement of Electric Vehicle Supply Equipment This Guidance provides a description of the types of requirements to be included in an employer's workplace charging request for...

311

Renewable Energy Equipment Exemption  

Energy.gov (U.S. Department of Energy (DOE))

Iowa allow a sales tax exemption for solar, wind, and hydroelectricity equipment. As of May 2013, the Iowa sales tax rate is 6%.

312

Maersk Line Equipment guide  

National Nuclear Security Administration (NNSA)

a total capacity of 85 cubic metres We offer various types of extra equipment: * Hanger beams which allow transport of garments on hangers without further packing * Lashing bars...

313

Insulation of Electrical Equipment  

Science Journals Connector (OSTI)

... A VACATION 'school' on the insulation of electrical equipment was held in the Electrical Engineering Department of the Imperial College of ... the universities. The purpose of the course was to consider the factors which are limiting insulation design in the main classes of electrical equipment, and the general principles which should ...

1952-12-13T23:59:59.000Z

314

Commercial equipment cost database  

SciTech Connect

This report, prepared for DOE, Office of Codes and Standards, as part of the Commercial Equipment Standards Program at Pacific Northwest Laboratory, specifically addresses the equipment cost estimates used to evaluate the economic impacts of revised standards. A database including commercial equipment list prices and estimated contractor costs was developed, and through statistical modeling, estimated contractor costs are related to equipment parameters including performance. These models are then used to evaluate cost estimates developed by the ASHRAE 90.1 Standing Standards Project Committee, which is in the process of developing a revised ASHRAE 90.1 standard. The database will also be used to support further evaluation of the manufacturer and consumer impacts of standards. Cost estimates developed from the database will serve as inputs to economic modeling tools, which will be used to estimate these impacts. Preliminary results suggest that list pricing is a suitable measure from which to estimate contractor costs for commercial equipment. Models developed from these cost estimates accurately predict estimated costs. The models also confirm the expected relationships between equipment characteristics and cost. Cost models were developed for gas-fired and electric water heaters, gas-fired packaged boilers, and warm air furnaces for indoor installation. Because of industry concerns about the use of the data, information was not available for the other categories of EPAct-covered equipment. These concerns must be addressed to extend the analysis to all EPAct equipment categories.

Freeman, S.L.

1995-01-01T23:59:59.000Z

315

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation  

Science Journals Connector (OSTI)

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the...

S. I. Gusev; V. N. Karpov; A. N. Kiselev; V. I. Kochkin

2009-09-01T23:59:59.000Z

316

The design, implementation and testing of data gathering instrumentation for measurement of electromagnetic interference in electric power substations  

E-Print Network (OSTI)

THE DESIGN, IMPLEMENTATION AND TESTING OF DATA GATHERING INSTRUMENTATION FOR MEASUREMENT OF ELECTROMAGNETIC INTERFERENCE IN ELECTRIC POWER SUBSTATIONS A Thesis by GARY WAYNE GERLOFF Submitted to the Graduate College of Texas AAM University... IN ELECTRIC POWER SUBSTATIONS A Thesis by GARY WAYNE GERLOFF Approved as to style and content by: B. Don Russell (Chairman of Committee) A. K. A IM Sallie She p rd (Member) August 1983 ABSTRACT The Design, Implementation and Testing of Data...

Gerloff, Gary Wayne

2012-06-07T23:59:59.000Z

317

Microsoft Word - CX-DixieSubstationUpgradesFY11_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

KEP-4 KEP-4 SUBJECT: Environmental Clearance Memorandum Brett Sherer Project Manager - KEP-4 Proposed Action: Upgrade of secondary containment facilities at Dixie Substation Budget Information: Work Order: 00004952 Categorical Exclusion Applied (Appendix B to Subpart D, 10 C.F.R. Part 1021): B4.6: Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility area including, but not limited to, switchyard rock grounding upgrades, secondary containment projects, paving projects, seismic upgrading, tower modifications, changing insulators, and replacement of poles, circuit breakers, conductors, transformers, and crossarms. Location: PLS T1S R8E S1 Dixie Substation in Elmore County, Idaho.

318

A procedure for derating a substation transformer in the presence of widespread electric vehicle battery charging  

SciTech Connect

This paper studies the effect of electric vehicle (EV) battery charging on a substation transformer that supplies commercial, residential, industrial, and EV load on a peak summer day. The analysis begins on modeling non-EV load with typical utility load shapes. EV load is modeled using the results from an analytical solution technique that predicts the net power and harmonic currents generated by a group of EV battery chargers. The authors evaluate the amount of transformer derating by maintaining constant daily transformer loss-of-life, with and without EV charging. This analysis shows that the time of day and the length of time during which the EVs begin charging are critical in determining the amount of transformer derating required. The results show that with proper control, EV charging may have very little effect on power system components at the substation level.

Staats, P.T.; Grady, W.M.; Arapostathis, A. [Univ. of Texas, Austin, TX (United States)] [Univ. of Texas, Austin, TX (United States); Thallam, R.S. [Salt River Project, Phoenix, AZ (United States)] [Salt River Project, Phoenix, AZ (United States)

1997-10-01T23:59:59.000Z

319

Marys Lake 69/115-kV transmission line upgrade and substation expansion projects  

SciTech Connect

Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

NONE

1996-05-01T23:59:59.000Z

320

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, Colorado  

Energy.gov (U.S. Department of Energy (DOE))

Western Area Power Administration (Western) – with USDA Forest Service, Arapaho and Roosevelt National Forest, as a cooperating agency – is preparing an EIS that analyzes the potential environmental impacts of a proposal to rebuild and upgrade two 115-kilovolt single-circuit transmission lines between the Flatiron Substation and the intersection of Mall Road and U.S. Highway 36 in Estes Park, Larimer County, Colorado. Additional information is available on Western’s project website.

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Property Tax Exemption for Residential Renewable Energy Equipment |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Property Tax Exemption for Residential Renewable Energy Equipment Property Tax Exemption for Residential Renewable Energy Equipment Property Tax Exemption for Residential Renewable Energy Equipment < Back Eligibility Residential Savings Category Bioenergy Solar Buying & Making Electricity Home Weatherization Water Heating & Cooling Commercial Heating & Cooling Heating Water Heating Wind Program Info State Colorado Program Type Property Tax Incentive Rebate Amount 100% exemption for renewable energy system property Most locally assessed renewable energy property meet the criteria to be classified as personal property under § 39-1-102 (11), C.R.S. For Colorado property taxation purposes, solar energy facilities property used to produce two (2) megawatts or less of AC electricity and wind energy facilities property used to produce two (2) megawatts or less of AC

322

Property:Incentive/EquipReqs | Open Energy Information  

Open Energy Info (EERE)

EquipReqs EquipReqs Jump to: navigation, search Property Name Incentive/EquipReqs Property Type Text Description Equipment Requirements. Pages using the property "Incentive/EquipReqs" Showing 25 pages using this property. (previous 25) (next 25) A AEP (Central and North) - CitySmart Program (Texas) + New Construction and Retrofit/Renovation projects that reduce peak kW demand AEP (Central and North) - Residential Energy Efficiency Programs (Texas) + See program web site AEP (Central and SWEPCO) - Coolsaver A/C Tune Up (Texas) + Customer must accept recommendations from a tune-up analysis. AEP (Central, North and SWEPCO) - Commercial Solutions Program (Texas) + New Construction and Retrofit/Renovation projects that reduce peak kW demand AEP (SWEPCO) - Residential Energy Efficiency Programs (Texas) + View program web site and contact AEP

323

Environmental Assessment of Proposed Lynch Creek Substation Project : Service to Eatonville and the Ohop Valley.  

SciTech Connect

Bonneville Power Administation (BPA) proposes to construct 3.2 miles of 115-kV transmission line from a tap point on Tacoma City Light's Cowlitz-LaGrande 115-kV line to a new 115/12.5-kV, 15/20/25 MVA substation to be located about 1 mile northwest of Eatonville, adjacent to the Eatonville cutoff road. This plan was selected following initial consideration of five alternative plans for satisfying electrical needs in the project area and following agreement with BPA's customers on a vicinity for the substation site. The vicinity selected is midway between the two load centers and would require the least construction of distribution line. Subsequently, four alternative line routes and two substation sites have been evaluated. These alternatives provide a range of costs, engineering solutions, and potential environmental impacts. This evaluation led to the selection of one line route. This document describes possible environmental impacts of the proposed actions. 7 refs, 9 figs., 5 tabs.

United States. Bonneville Power Administration.

1983-05-01T23:59:59.000Z

324

The effect of magnetic field on optimal design of a rigid-bus substation  

SciTech Connect

Substation rigid-bus design involves electrical, mechanical, and structural considerations. In order to integrate these considerations into one document, IEEE in cooperation with ANSI has issued a comprehensive guide for design of substation rigid-bus systems. The design process based on this guide involves substantial manual effort to integrate all types of calculations. This is particularly evident when the computations have to be repeated several times in order to arrive at a more economic design. In an earlier paper the authors presented a mathematical model and computer program which automates the design process. Recently there has been concern expressed about the possible biological effects of low level magnetic fields. In view of this, a new design constraint taking into account the limits imposed on the magnitude of the magnetic field can be added to the design guidelines. In this paper the authors introduce such a constraint and they show how the magnitude of allowable magnetic field at a specified distance from the station buses affects the optimal design of a rigid bus substation.

Anders, G.J.; Ford, G.L.; Horrocks, D.J. (Ontario Hydro, Toronto, Ontario (Canada))

1994-07-01T23:59:59.000Z

325

Proposal for the award of a contract for the design, supply, installation and commissioning of a 66 kV electrical substation  

E-Print Network (OSTI)

Proposal for the award of a contract for the design, supply, installation and commissioning of a 66 kV electrical substation

2012-01-01T23:59:59.000Z

326

An investigation approach to test protection intelligent electronic devices (IEDs) in IEC 61850 based substation automation systems (SAS) at station level.  

E-Print Network (OSTI)

??This thesis has developed a new approach to trace virtual protection signals in Electrical substation networks. The main goal of the research was to analyse… (more)

Nick, Shawn

2014-01-01T23:59:59.000Z

327

Equipment Insulation | Open Energy Information  

Open Energy Info (EERE)

List of Equipment Insulation Incentives Retrieved from "http:en.openei.orgwindex.php?titleEquipmentInsulation&oldid267163" Category: Articles with outstanding TODO tasks...

328

NSLS Electrical Equipment Inspection  

NLE Websites -- All DOE Office Websites (Extended Search)

Electrical Equipment Inspection Information Electrical Equipment Inspection Information A note to vendors visiting NSLS A note to users visiting NSLS Proteus Electrical Conformity Remediation Currently Certified Electrical Equipment Inspectors: First Line Contacts Email Extension Poshka, Dennis poshka@bnl.gov 2825 Alternate Contacts Boerner Jr, Albert aboerner@bnl.gov 5990 Buda, Scott buda@bnl.gov 3914 Caruso, Michael caruso@bnl.gov 4100 Chmiel, Robert chmiel@bnl.gov 8141 Church, Randolph church@bnl.gov 2736 Clay, Barret clay@bnl.gov 7284 D'Alsace, Roy dalsace@bnl.gov 3973 Danneil, Christopher cdanneil@bnl.gov 8609 Davila, Peter davila@bnl.gov 7625 De Toll, Peter detoll@bnl.gov 4100 Durfee, Douglas ddurfee@bnl.gov 7625 Fulkerson, Michael fulkerso@bnl.gov 5194 Gallagher, John jgallagher@bnl.gov 5770 Harder, David dharder@bnl.gov 4978

329

Scientist Equipment and Outline  

NLE Websites -- All DOE Office Websites (Extended Search)

Outline and Equipment Outline and Equipment LIGHT AND COLOR Grade levels: can be adapted for grades 2-8. Length of time: 30-45 minues. Room preference: Double classroom or all-purpose room. Equipment is located in the Lederman Science Center. Talk to Susan Dahl to borrow this set. Spectrum tube power supply, gas tubes and diffraction grating glasses Light box with red, green, and blue translucent film Power chord, extension chord Large set of lenses Small concave and convex lenses Magnetic optics kit, includes a small laser Slinky Flashlight Clear plastic tub, powdered milk Water Radiometer Electromagnetic energy spectrum poster Set of red, green and blue flood lights Where does light come from? Use a boy and a girl to make a human demonstration of molecules and atoms. Have students rub their hands together and notice friction equals heat.

330

Equipment Operational Requirements  

SciTech Connect

The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

2009-06-11T23:59:59.000Z

331

Emergency Facilities and Equipment  

Directives, Delegations, and Requirements

This volume clarifies requirements of DOE O 151.1 to ensure that emergency facilities and equipment are considered as part of emergency management program and that activities conducted at these emergency facilities are fully integrated. Canceled by DOE G 151.1-4.

1997-08-21T23:59:59.000Z

332

Equipment for ?-Radiography  

Science Journals Connector (OSTI)

... felt for a well-designed protective carrier and exposure unit for use with radium or radon. The announcement that Johnson Matthey and Co., Ltd., are manufacturing protective equipment ... will assist the industrial radiologist to take advantage of the improved supplies of radium and radon which are now available (Nature, June 4, 1949, p. 867). ...

1949-09-10T23:59:59.000Z

333

Microsoft Word - CX-HatwaiSubstationUpgradesFY11_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

18, 2011 18, 2011 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Brett Sherer Project Manager - KEP-4 Proposed Action: Upgrade of secondary containment facilities at Hatwai Substation Budget Information: Work Order: 00004952 Categorical Exclusion Applied (Appendix B to Subpart D, 10 C.F.R. Part 1021): B4.6: Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility area including, but not limited to: switchyard rock grounding upgrades, secondary containment projects, paving projects, seismic upgrading, tower modifications, changing insulators, and replacement of poles, circuit breakers, conductors, transformers, and crossarms.

334

Comment on Relative Magnetic Substate Amplitudes in Foil Excitation of Fast Hydrogen Atoms  

Science Journals Connector (OSTI)

If the particle-foil interaction potential governing production of H atoms coherently excited by passage through thin foils obeys the LS coupling scheme applied by Macek (conservation of z components of total orbital and spin angular momenta of the entire particle-foil system, and incoherence of final states of foil constituents), the ad hoc assumption that random phases prevail among the hydrogenic magnetic substate amplitudes invoked in the interpretation of certain recent experiments is avoided. Arguments concerning relative phases of states of different orbital angular momentum are unaffected.

I. A. Sellin

1971-04-01T23:59:59.000Z

335

Granby Pumping Plant Switchyard - Windy Gap Substation Transmission Line Rebuild, Grand County, Colorado: Final Environmental Impact Statement Executive Summary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PUMPING PLANT SWITCHYARD - WINDY GAP PUMPING PLANT SWITCHYARD - WINDY GAP SUBSTATION TRANSMISSION LINE REBUILD, GRAND COUNTY, COLORADO DOE/EIS-0400 Final Environmental Impact Statement Executive Summary Grand County, Colorado June 2013 Granby Pumping Plant-Windy Gap Substation Transmission Line Rebuild Project FEIS Executive Summary ES-1 EXECUTIVE SUMMARY Introduction Western Area Power Administration (Western), a power marketing administration within the U.S. Department of Energy (DOE), is proposing to rebuild and upgrade the Granby Pumping Plant Switchyard-Windy Gap Substation transmission line in Grand County, Colorado (Grand County). This Environmental Impact Statement (EIS) analyzes the impacts associated with the proposal to remove approximately 13.6 miles of 69-kilovolt (kV) transmission line, construct approximately

336

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-96) Snohomish District Substations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6) 6) - Snohomish District Substations Dennis Sjoquist - TFN/Snohomish Snohomish Regional Manager Proposed Action: Vegetation Management for the following facilities located in the Snohomish District: Bellingham Custer Fidalgo Intalco Lopez Island Monroe Murray, V.M. Snohomish Snoking Whatcom Whatcom Skagit Whatcom San Juan Snohomish Snohomish Snohomish Snohomish Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes total vegetation management (bareground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Snohomish District of the Snohomish Region. Description of the Proposal: BPA proposes to manage vegetation inside and around electrical substations and associated facilities.

337

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-94) Covington District Substations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4) 4) - Covington District Substations Dennis Sjoquist - TFN/Snohomish Snohomish Regional Manager Proposed Action: Vegetation Management for the following facilities located in the Covington District: Covington Echo Lake Lynch Creek Maple Valley Narrows Raver, P.J. South Tacoma Steilacoom Surprise Lake Tacoma King King Pierce King Pierce King Pierce Pierce Pierce Pierce Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes total vegetation management (bareground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Covington District of the Snohomish Region. Description of the Proposal: BPA proposes to manage vegetation inside and around electrical substations and associated facilities.

338

field_equipment.indd  

NLE Websites -- All DOE Office Websites (Extended Search)

EQUIPMENT INVENTORY EQUIPMENT INVENTORY Trucks * Five vac/pressure trucks, 60-90 bbl, up to 5 bpm at 5,000 lb. * Water/fi re truck, 110 bbl * Two dump trucks: 5-yard and 12-yard * Belly dump trailer * Chemical injection truck, 20 bbl capacity * Three crane trucks: 6,000 lb., 8,000 lb., and 30 ton * Klaeger swab truck * Rig-up truck with 21-foot poles, 30,000-lb. capacity * Winch truck, 40,000-lb. capacity * Two bucket trucks: 25-foot and 28-foot reach * Two welding trucks with Miller Trailblazer welder * Two Ditch Witches: 8" x 7' and 6" x 3" * International PayStar 5000 transport truck * Western Star transport truck Backhoes & Loaders * John Deere 410G backhoe * Cat 420 backhoe * Case 20W loader with 2-yard bucket * Bobcat skid loader with bucket, forks, post hole digger, and trencher attachments

339

Measurement system design and implementation for grid-connected marine substation  

Science Journals Connector (OSTI)

A marine substation for a grid-connected wave power plant has been designed and constructed at Uppsala University. The measurement system for the substation has been developed from basics, and the procedure is described in this article. Subsea electrical installations set high constraints on the control and data acquisition systems used, and traditional GSM networks and GPS time synchronization are difficult and inefficient. These circumstances exclude many well-proven methods to be utilized. A compactRIO-based system, with integrated real-time controller and Field-Programmable Gate Array chip, is chosen as most suitable for this task. The system is designed to meet the special requirements encountered in this unusual application, including large data sampling, grid connection control and protection systems. The system is communicating to shore via a subsea copper cable and single-pair high-speed digital subscriber line modems. The design was successful and full-fills all the system requirements. The aim of the article is to provide future researchers with a good design and implementation procedure for setting up large measurement systems.

Rickard Ekström; Venugopalan Kurupath; Olle Svensson; Mats Leijon

2013-01-01T23:59:59.000Z

340

Video surveillance-based insulator condition monitoring analysis for substation monitoring system (SMS)  

Science Journals Connector (OSTI)

Video surveillance (VS) of electric power lines along with its accessories such as insulators has emerged as a potential alternative for the traditional practice of on-site physical detection. There has been a paradigm shift in electric substation automation using substation monitoring system (SMS). Since the damaged insulators severely affect the distribution system performance in terms of reduction in voltage as well as flow of leakage currents, therefore, the incorporation of insulator health as an augmented feature in SMS would improve the quality and reliability of power supply. By using information technology, the automation of insulator monitoring of power system is made faster to recover the fault system immediately. This paper presents a methodology for insulator condition analysis based on VS combined with wavelet coefficient differentiator (WCD) for SMS purposes. The case studies and results contained herein corroborate the efficacy of the proposed methodology to dispense with the conventional on-site physical methods, which are not only tedious, but also time-consuming.

Velaga Sreerama Murthy; D.K. Mohanta; Sumit Gupta

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Measurement of the acoustic pressure distribution occurring around an aerial substation adjacent to apartment buildings  

Science Journals Connector (OSTI)

The subject matter of the research work presented in this paper refers to the measurements of the values of the acoustic pressure levels (noise) occurring around a main feeding?point aerial substation adjacent to apartment buildings. The paper presents the values of the noise accompanying the particular power devices mainly transformers during their regular operation. The main aim of this research work was the comparison and assessment of the acoustic pressure values measured with the permissible values defined by environmental standards binding in Poland. The research analysis carried out proved that during a long?term operation of power appliances installed in substations the acoustic pressure level that they emit into the environment is not constant but is subject to changes. Thus the increase of the noise level above the permissible values can be the cause of violation of environmental standards. Due to a significant increase of people's awareness and readiness to claim their rights the main consequence of violating the standards is a growing number of claims. Therefore it is imperative that the level of the acoustic pressure be monitored during routine tests especially around high?power transformers.

Sebastian Borucki; Tomasz Boczar; Andrzej Cichon

2008-01-01T23:59:59.000Z

342

Substations for Decentralized Solar District Heating: Design, Performance and Energy Cost  

Science Journals Connector (OSTI)

Abstract The development of solar district heating is gaining more and more interest, but, in some case the space available for the integration of solar collectors on the ground is limited and the use of decentralized systems is necessary. For decentralized solar district heating systems different hydraulic schemes at the substation level, with or without local use of solar energy, are possible. The present paper detailed an advanced study on decentralized solar district heating system using dynamic simulation software. Nine different hydraulic schemes for substations have been investigated with a return to return feed in. For each scheme many parameters that influence the performance of the solar installation have been studied such as the district heating network return temperature, the solar collector area and the type of solar collector (low temperature or high temperature solar collector). The comparison between the different hydraulic schemes is based on thermal efficiency but also on solar energy cost using the methodology of the Levelized Cost Of Energy (LCOE).

Cedric Paulus; Philippe Papillon

2014-01-01T23:59:59.000Z

343

Accommodation & ACS Advertising Policy  

E-Print Network (OSTI)

Accommodation & Campus Services. ACS Advertising Policy This paper states the University department Accommodation & Campus Services' (ACS) policy on advertising, sponsorship and promotions and any restrictions. Accommodation & Campus Services, the Students' Union, all affiliated bodies and advertisers are expected

Stevenson, Mark

344

ACS-GDCh ALLIANCE  

Science Journals Connector (OSTI)

ACS-GDCh ALLIANCE ... Other aspects of the strategic collaboration alliance will identify additional activities and services that could be mutually beneficial to both ACS and GDCh members, in keeping with both organizations’ strategic goals. ...

MADELEINE JACOBS

2010-09-20T23:59:59.000Z

345

primary substation  

Science Journals Connector (OSTI)

This one-of-a-kind reference is unmatched in the breadth and scope of its coverage and serves as the primary reference for students and professionals in computer science and communications. The Dictionary feat...

2001-01-01T23:59:59.000Z

346

distribution substation  

Science Journals Connector (OSTI)

This one-of-a-kind reference is unmatched in the breadth and scope of its coverage and serves as the primary reference for students and professionals in computer science and communications. The Dictionary feat...

2001-01-01T23:59:59.000Z

347

Equipment Certification | Open Energy Information  

Open Energy Info (EERE)

Equipment Certification Equipment Certification Jump to: navigation, search Policies requiring renewable energy equipment to meet certain standards serve to protect consumers from buying inferior equipment. These requirements not only benefit consumers; they also protect the renewable energy industry by making it more difficult for substandard systems to reach the market. [1] Equipment Certification Incentives CSV (rows 1 - 19) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Canada Oil and Gas Operations Act (Canada) Environmental Regulations Equipment Certification Fees Generating Facility Rate-Making Generation Disclosure Industry Recruitment/Support Safety and Operational Guidelines Siting and Permitting Canada Commercial Construction Developer

348

Early Equipment Management  

E-Print Network (OSTI)

starting with the ones that could cause the most human harm. This is also an excellent time to discuss all the lockout/tagout points on the machine, determine how much safety training is necessary and if there are enough warning stickers. The idea... needed. One-point lessons should be completed on all inspection, lubrication, and lockout/tagout points. Equipment labels should be created at this time including lockout/tagout and predetermined set-points. The key to a successful EEM program...

Schlie, Michelle

2007-05-18T23:59:59.000Z

349

China production equipment sourcing strategy  

E-Print Network (OSTI)

This thesis recommends a China business and equipment strategy for the Controls Conveyor Robotics Welding (CCRW) group at General Motors. The current strategy is to use globally common equipment through predetermined global ...

Chouinard, Natalie, 1979-

2009-01-01T23:59:59.000Z

350

Granby Pumping Plant Switchyard - Windy Gap Substation Transmission Line Rebuild, Grand County, Colorado: Final Environmental Impact Statement Appendices  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PUMPING PLANT SWITCHYARD - WINDY GAP PUMPING PLANT SWITCHYARD - WINDY GAP SUBSTATION TRANSMISSION LINE REBUILD, GRAND COUNTY, COLORADO DOE/EIS-0400 Final Environmental Impact Statement Appendices Grand County, Colorado June 2013 Appendix A EIS Scoping Report GRANBY PUMPING PLANT - WINDY GAP TRANSMISSION LINE REBUILD PROJECT ENVIRONMENTAL IMPACT STATEMENT SCOPING SUMMARY REPORT December 4, 2007

351

IAEA safeguards equipment  

Science Journals Connector (OSTI)

The International Atomic Energy Agency (IAEA) operates a large diversity of equipment to verify nuclear materials, contributing to the confirmation of the states' compliance with their respective nonproliferation obligations. The variety of physical and chemical properties of nuclear materials, as well as their storage environment, requires an arsenal of instruments. Additionally, the IAEA applies various containment and surveillance measures to maintain the continuity of knowledge on nuclear materials. The IAEA need ongoing equipment development to provide its inspectorate with the state-of-the-art tools for performing various safeguards activities. These activities include the measurement of declared nuclear material inventories and flows, the application of enhanced containment and surveillance measures and the search for the indicators of undeclared nuclear material and clandestine nuclear activities. The IAEA is facing increasing demands to perform remote verification of nuclear material flows utilising unattended monitoring systems. Additional analytical capabilities and effective non-destructive assay methods will be indispensable in the future for reinforcing the IAEA's ability to detect undeclared nuclear materials and activities.

M. Zendel

2008-01-01T23:59:59.000Z

352

Joint first-passage probability, and reliability of systems under Stochastic excitation  

E-Print Network (OSTI)

reliability of electrical substation equipment and system. ”nents, e.g. , electrical substations with interconnectedrepresent a small electrical substation. Equip- ment items 1

Song, J; Kiureghian, A D

2006-01-01T23:59:59.000Z

353

Microsoft Word - CX-SouthTacomaSubstationOlympicPipelineFenceUpgrade_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7, 2011 7, 2011 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Timothy Wicks Realty Specialist - TERR-Covington Proposed Action: Grant the Olympic Pipeline Company permission to upgrade an existing fence along the northern property line of Bonneville Power Administration's (BPA) South Tacoma Substation to enhance security. PP&A Project No.: PP&A-2054 Budget Information: N/A Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.11 Fencing, no adverse effect on wildlife movement/surface water flow. Installation of fencing, including that for border marking that will not adversely affect wildlife movements or surface water flow. Location: S36 T9N R3E WM, in Pierce County, Washington. BPA Parcel #STAC-SS-SY

354

Microsoft Word - CX-GarrisonSubstationAccessRoadImprovementFY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2013 8, 2013 REPLY TO ATTN OF: KEPR-Bell-1 SUBJECT: Environmental Clearance Memorandum Jonathan Malmberg Project Manager - TETQ-TPP-3 Proposed Action: Maintenance along sections of the access road leading to Bonneville Power Administration's (BPA) Garrison Substation PP&A Project No.: 2609 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine Maintenance. B1.13 Pathways, short access roads, and rail lines. Location: As identified in table below: Township Range Section County 9N 11W 14, 13, 24 Powell 9N 10W 19, 30, 20 Powell Proposed by: BPA Description of the Proposed Action: BPA proposes repairing a corrugated metal pipe end; making minor asphalt repairs; and grading, shaping, compacting, and placing road aggregate on 20,005 linear feet

355

Type B investigation of electrical fault in 351 Substation, December 4, 1994  

SciTech Connect

On December 4, 1994, at 2132:10 hours, an electrical failure of a cable-tapping splice resulted in a fire in the 300 Area of the DOE Hanford Site. The fire occurred in the yard of Substation 351 in electrical Vault R122V, where the cable-tapping splice was located. The fire incinerated all cables passing to and through the vault causing them to fail. The failure of the cables resulted in a power outage to twenty customers in the 300 Area. The vault was electrically isolated, and power was restored to the electrical distribution system at 2311 hours. This report contains the accident scenario, accident analysis, direct cause and root and contributing causes.

Debban, H.L.; Shearer, C.A.; Boger, R.M.; McDonald, G.P. [ICF Kaiser Hanford Co., Richland, WA (United States); Eyre, L.E.; Dell, L.D.; Kelly, D.S. [Westinghouse Hanford Co., Richland, WA (United States)

1995-02-01T23:59:59.000Z

356

Final environmental assessment for vegetation control at VHF stations, microwave stations, electrical substations, and pole yards  

SciTech Connect

Southwestern Power Adm. operates very high frequency (VHF) and microwave radio stations, electrical substations, and pole yards for electric power transmission throughout AR, MO, and OK. Vegetation growth at the stations must be suppressed for safety of operation and personnel. Southwestern has been using a combination of mechanical/manual and herbicide control for this purpose; Federally- mandated reductions in staff and budgetary resources require Southwestern to evaluate all potentially efficient methods for vegetation control. Three alternatives were examined: no action, mechanical/manual control, and (proposed) a combination of mechanical/manual and herbicide control. Environmental impacts on air and water quality, wetlands, wildlife, endangered species, archaeological and other resources, farmland, human health, transportation, etc. were evaluated.

NONE

1995-10-13T23:59:59.000Z

357

Experimental evaluation of radiator control based on primary supply temperature for district heating substations  

Science Journals Connector (OSTI)

In this paper, we evaluate whether the primary supply temperature in district heating networks can be used to control radiator systems in buildings connected to district heating; with the purpose of increasing the ?T. The primary supply temperature in district heating systems can mostly be described as a function of outdoor temperature; similarly, the radiator supply temperature in houses, offices and industries can also be described as a function of outdoor temperature. To calibrate the radiator control system to produce an ideally optimal radiator supply temperature that produces a maximized ?T across the substation, the relationship between the primary supply temperature and outdoor temperature must be known. However, even if the relation is known there is always a deviation between the expected primary supply temperature and the actual temperature of the received distribution media. This deviation makes the radiator control system incapable of controlling the radiator supply temperature to a point that would generate a maximized ?T. Published simulation results show that it is possible and advantageous to utilize the primary supply temperature for radiator system control. In this paper, the simulation results are experimentally verified through implementation of the control method in a real district heating substation. The primary supply temperature is measured by the heat-meter and is shared with the radiator control system; thus no additional temperature sensors were needed to perform the experiments. However additional meters were installed for surveillance purposes. To maintain a stable indoor temperature at times when the primary supply and outdoor temperatures deviates from their assumed relation, the radiator system flow must be controlled by an additional control-loop. The results confirms that it is possible to control the radiator system based on the primary supply temperature while maintaining comfort; however, conclusions regarding improvements in ?T were hard to distinguish.

Jonas Gustafsson; Jerker Delsing; Jan van Deventer

2011-01-01T23:59:59.000Z

358

Measured Peak Equipment Loads in Laboratories  

E-Print Network (OSTI)

of measured equipment load data for laboratories, designersmeasured peak equipment load data from 39 laboratory spacesmeasured equipment load data from various laboratory spaces

Mathew, Paul A.

2008-01-01T23:59:59.000Z

359

Electrical Equipment Inventory and Inspection Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Electrical Equipment Inventory and Inspection Information APS Non-NRTL Electrical Equipment Inventory Spreadsheet ANL Recognized Reputable Electrical Equipment Manufacturer List as...

360

Celebrate Earth Day with ACS  

Science Journals Connector (OSTI)

Celebrate Earth Day with ACS ... Winners of the ACS-sponsored Earth Day 2004 music video contest are reported. ... ACS resources for celebrating the Earth Day 2005 theme, "Air—Here, There, Everywhere", are discussed. ...

Erica K. Jacobsen

2005-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

The Results of Tests of ASK-100-4UKhL4 Type Asynchronized Compensators at the Beskudnikovo 500 kV Substation  

Science Journals Connector (OSTI)

Two ASK-100-4UKhL4 100 Mvar asynchronized compensators were introduced into operation in the 500 kV Beskudnikovo substation in 2012. The results of systems tests...

L. G. Volodarskii; I. Ya. Dovganyuk; R. D. Mnev…

2014-01-01T23:59:59.000Z

362

Information technology equipment cooling system  

SciTech Connect

According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

Schultz, Mark D.

2014-06-10T23:59:59.000Z

363

INL '@work' heavy equipment mechanic  

ScienceCinema (OSTI)

INL's Cad Christensen is a heavy equipment mechanic. For more information about INL careers, visit http://www.facebook.com/idahonationallaboratory.

Christensen, Cad

2013-05-28T23:59:59.000Z

364

Commercial Kitchen & Food Service Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Commercial Commercial Industrial Lighting Energy Smart Grocer Program HVAC Program Shell Measures Commercial Kitchen & Food Service Equipment Plug Load New...

365

A new high performance AC to DC rectifier with input power factor correction and harmonic reduction capacity  

E-Print Network (OSTI)

Many conventional switching power supplies in data processing equipment and low power motor drive systems operate by rectifying the input ac line voltage and filtering it with large electrolytic capacitors. Because this process involves both...

Martinez, Roberto

2012-06-07T23:59:59.000Z

366

Commercial Cooking Equipment | Open Energy Information  

Open Energy Info (EERE)

Cooking Equipment Incentives Retrieved from "http:en.openei.orgwindex.php?titleCommercialCookingEquipment&oldid38063...

367

Food Service Equipment | Open Energy Information  

Open Energy Info (EERE)

Service Equipment Incentives Retrieved from "http:en.openei.orgwindex.php?titleFoodServiceEquipment&oldid380620...

368

Holbrook Substation Superconductor Cable System, Long Island, New York Final Report  

SciTech Connect

The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and safer since it is now a programmed procedure versus the former written procedure that was still subject to human variation in the process.

Maguire, James; McNamara, Joseph

2010-06-25T23:59:59.000Z

369

Classification of sags gathered in distribution substations based on multiway principal component analysis  

Science Journals Connector (OSTI)

Voltage sags, whether they occur in transmission or distribution systems, may severely damage the loads connected to the power system. As these problems could cost a great deal financially, electric utilities are very interested in finding the origins of sags, that is, whether they have been originated in the transmission network (high voltage (HV)) or in the distribution system (medium voltage (MV)). In addition to the needs of utilities and regulators, many researchers have been prompted to develop reliable methods to properly classify sags. Several of these methods, based on classifying meaningful features extracted from data and waveforms, have been proposed in the literature. Unlike those methods, though, we propose a systematic transformation of data, based on multiway principal component analysis (MPCA), to develop a new voltage sag classification procedure. Sampled voltage and current waveforms of previously registered sags are used together with the MPCA technique to obtain a lower dimensional model. This model is then used to project new sags and classify them according to their origin in the power system. Different classification criteria and parameters are examined to maximize the classification rates of not yet seen sags. Applying the proposed method to real sags recorded in substations demonstrates its applicability and power.

Abbas Khosravi; Joaquim Meléndez; Joan Colomer

2009-01-01T23:59:59.000Z

370

Rural community noise caused by 345/138 kV substation transformer  

Science Journals Connector (OSTI)

Residents 360 m (1200 ft) from a large (6 × 8 × 4.5 m high) 345/138 kV transformer installed in a new power substation in a rural setting complained of its noise emission especially at night. Octave band and 24?h A?weighted noise measurements were made. The 120?Hz sound level was found to be 90 to 105 dB at the transformer surface. Transformer noise emission did not vary significantly with transformer loading or time of day. The distant (360 m) noise level was from 40 to 47 dBA (N?30 to N?45) depending on intervening terrain and time of day. In calm summer air the annoying sound was found to be in the 125?Hz band at the residence beyond a vegitated rise and 250 to 500 Hz for a residence with line?of?sight contact over a shallow depression. The line?of?sight resident's complaint that the noise was greatest at night was corroborated by the 24?h measurement. That noise level was found to be typically 38 dBA from 11 a.m. to 7 p.m. and 45 dBA from 9 p.m. to 6 a.m. It is postulated that the depression accumulated cool air at night thus refracting the sound onto that site. Recommendations for a noise barrier wall was made to the power company operator.

Angelo J. Campanella

1981-01-01T23:59:59.000Z

371

Energy efficiency standards for residential and commercial equipment: Additional  

NLE Websites -- All DOE Office Websites (Extended Search)

207 207 Energy Efficiency Standards for Residential and Commercial Equipment: Additional Opportunities Greg Rosenquist, Michael McNeil, Maithili Iyer, Steve Meyers, and Jim McMahon Environmental Energy Technologies Division Lawrence Berkeley National Laboratory University of California Berkeley, CA 94720 September 2004 This work was supported by the National Commission on Energy Policy through the U.S. Department of Energy under Contract No. DE-AC03-76SF00098. Table of Contents 1. Introduction........................................................................1 2. Products Considered..............................................................2 3. Technology Cost-Efficiency Analysis...........................................3

372

Microfabricated AC impedance sensor  

DOE Patents (OSTI)

A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

Krulevitch, Peter (Pleasanton, CA); Ackler, Harold D. (Sunnyvale, CA); Becker, Frederick (Houston, TX); Boser, Bernhard E. (Berkeley, CA); Eldredge, Adam B. (Austin, TX); Fuller, Christopher K. (Livermore, CA); Gascoyne, Peter R. C. (Bellaire, TX); Hamilton, Julie K. (Tracy, CA); Swierkowski, Stefan P. (Livermore, CA); Wang, Xiao-Bo (San Diego, CA)

2002-01-01T23:59:59.000Z

373

TRANSPORT AND EMPLACEMENT EQUIPMENT DESCRIPTIONS  

SciTech Connect

The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) Transport and Emplacement in the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. The Transport and Emplacement equipment described in this document consists of the following: (1) WP Transporter; (2) Reusable Rail Car; (3) Emplacement Gantry; (4) Gantry Carrier; and (5) Transport Locomotive.

NA

1997-09-29T23:59:59.000Z

374

Laboratory Equipment Donation Program - Guidelines  

Office of Scientific and Technical Information (OSTI)

The United States Department of Energy, in accordance with its The United States Department of Energy, in accordance with its responsibility to encourage research and development in the energy area, awards grants of used energy-related laboratory equipment. Universities, colleges and other non-profit educational institutions of higher learning in the United States are eligible to apply for equipment to use in energy-oriented educational programs in the life, physical, and environmental sciences, and in engineering. The equipment listed in this database is available for grant; however, specific items may be recalled for DOE use and become unavailable through the program. Frequently Asked Questions Who is eligible to apply for equipment? Any non-profit, educational institution of higher learning, such as a middle school, high school, university, college, junior college, technical

375

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Single Package Vertical Air Conditioners and Heat Pumps Single Package Vertical Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's energy conservation standards for single package vertical air conditioners and heat pumps as a separate equipment class since 2008. Before 2010, this equipment was regulated under the broader scope of commercial air conditioning and heating equipment. Single package vertical air conditioners and heat pumps are commercial air conditioning and heating equipment with its main components arranged in a vertical fashion. They are mainly used in modular classrooms, modular office buildings, telecom shelters, and hotels, and are typically installed on the outside of an exterior wall or in a closet against an exterior wall but inside the building.

376

LANSCE | Lujan Center | Ancillary Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Ancillary Equipment Ancillary Equipment For general questions, please contact the Lujan Center Sample Environments responsible: Victor Fanelli | vfanelli@lanl.gov | 505.667.8755 Sample and Equipment Shipping Instructions For questions regarding shipping procedures, contact Lujan Center Experiment Coordinator: Leilani Conradson | leilani@lanl.gov | 505.665.9505 Low Temperature Equipment Specifications Flight Path/Instrument Compatibility Responsible Displex closed-cycle refrigerators Tmin= 4 K to 12 K Tmax= 300 K to 340 K 11 - Asterix 04 - HIPPO 03 - HIPD 10 - LQD 02 - SMARTS Victor Fanelli vfanelli@lanl.gov Or particular instrument scientist Top loading closed-cycle refrigerator T = 10 K to 500 K option of in situ gas adsorption cell 07 - FDS Luke Daemon lld@lanl.gov Monika Hartl hartl@lanl.gov

377

Equipment Inventory | Sample Preparation Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

Resources Title Equipment Type Facility Laboratory Building Room Accumet Basic AB15 pH meter pH Meter SSRL BioChemMat Prep Lab 2 131 209 Agate Mortar & Pestle Sets Agilent 8453...

378

Bulk Hauling Equipment for CHG  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

load of CHG Semitrailer Mass Trailer or ModuleChassis Module Mass Hydrogen Gas Mass CAPITAL EXPENDITURE FOR BULK HAULING EQUIPMENT For large consumption, total CapEx for...

379

Certified APS Electrical Equipment Inspectors  

NLE Websites -- All DOE Office Websites (Extended Search)

APS Designated Electrical Equipment Inspectors : Division Phone Page e-mail Jonathan Baldwin XSD 2-6977 4-6977 jbaldwin@aps.anl.gov Adam Brill ASD 2-9968 4-4559 abrill@aps.anl.gov...

380

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Direct Heating Equipment and Pool Heaters Active Mode Test Procedures Direct Heating Equipment and Pool Heaters Active Mode Test Procedures Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to amend the active mode test procedures for direct heating equipment and pool heaters. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding active mode test procedures for direct heating equipment and pool heaters. 78 FR 63410 (October 24, 2013). The comment deadline is January 7, 2014. Public Meeting Information

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Microsoft Word - CX_HatRockEquipmentDisposition.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

station taps PacifiCorp's McNary-Wallula 230-kilovolt (kV) line to serve BPA's Hat Rock Substation. PacifiCorp is in the process of rebuilding the switching station, including...

382

Permit for Charging Equipment Installation: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Compliance with the following permit will allow the installation and operation of electric vehicle charging equipment at a Compliance with the following permit will allow the installation and operation of electric vehicle charging equipment at a residence in the City, State jurisdiction. This permit addresses one of the following situations: Only an additional branch circuit would be added at the residence A hard-wired charging station would be installed at the residence. The attached requirements for wiring the charging station are taken directly out of the 2011 edition of the National Electrical Code (NEC) NFPA 70, Article 625 Electric Vehicle Charging System. This article does not provide all of the information necessary for the installation of electric vehicle charging equipment. Please refer to the current edition of the electrical code adopted by the local jurisdiction for additional installation requirements. Reference to the 2011 NEC may be

383

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation  

SciTech Connect

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the electric power, the harmonic composition of the network currents of the reactor for different values of the reactive power consumed, the determination of the regulating characteristics of the reactor, the speed of response of the shunting reactor in the current and voltage stabilization modes, and also the operation of the reactor under dynamic conditions for different perturbations, are presented. The results obtained are analyzed.

Gusev, S. I. [JSC 'FSK EES' (Russian Federation); Karpov, V. N.; Kiselev, A. N.; Kochkin, V. I. [Scientific-Research Institute of Electric Power Engineering (VNIIE) - Branch of the JSC 'NTTs Elektroenergetiki', (Russian Federation)

2009-09-15T23:59:59.000Z

384

Materials Selection Considerations for Thermal Process Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Materials Selection Considerations for Thermal Process Equipment: A BestPractices Process Heating Technical Brief Materials Selection Considerations for Thermal Process Equipment:...

385

CRAD, Nuclear Facility Construction - Mechanical Equipment -...  

Office of Environmental Management (EM)

Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 CRAD, Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 June 26, 2012 Nuclear Facility...

386

Request an Inspection of User Electrical Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Request for an Electrical Equipment Inspection All APS User electronic and electrical equipment must be inspected before use in an experiment. Please ask your beamline to make...

387

Summary of Construction Equipment Tests and Activities  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment Tests A series of tests were conducted by the APS Construction Vibration Measurement Task Force using various pieces of construction equipment at the APCF...

388

Best Management Practice #11: Commercial Kitchen Equipment  

Energy.gov (U.S. Department of Energy (DOE))

Commercial kitchen equipment represents a large set of water users in the non-residential sector. Water efficiency for commercial kitchen equipment is especially important because high volume...

389

EIS-0183: Record of Decision | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

interconnection to the FCRTS at BPA's Jones Canyon Substation in Gilliam County, Oregon. BPA will expand this existing substation and install new equipment at the substation to...

390

Computational Needs for the Next Generation Electric Grid Proceedings  

E-Print Network (OSTI)

generation  equipmentsubstations,  distribution  lines, energy resources (DER),  substation and distribution.  the next generation of substation automation solutions.  It 

Birman, Kenneth

2012-01-01T23:59:59.000Z

391

PNNL: EDO - Facilities & Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Facilities & Equipment Facilities & Equipment Facilities Equipment Decades of government investment on and around the Pacific Northwest National Laboratory campus has made PNNL a business-friendly resource for conducting a wide range of research. As a mission-focused organization, we are dedicated to teaming with government agencies, industry and academia to address what we believe are among the nation's most pressing needs in the areas of energy, environment, national security, and fundamental science. But behind these important missions is a wealth of supporting capabilities including incubator space, research laboratories, and user facilities that may be just what your business needs. We invite you to learn more about how we can work with businesses as well as what research laboratories and user facilities are available.

392

CD54AC04, CD74AC04 HEX INVERTERS  

E-Print Network (OSTI)

°C to 125°C SOIC M Tube CD74AC04M AC04M­55°C to 125°C SOIC ­ M Tape and reel CD74AC04M96 AC04M CDIP-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

393

DOE 10 CFR Part 431 EERE-2010-BT-TP-0036 RIN 1904-AC-38 Submission of Comments by Howe Corporation  

Energy.gov (U.S. Department of Energy (DOE))

Comments to the following DOE Proposed Rules:10 CFR Part 431[Docket No. EERE-2010-BT-TP-0036]RIN 1904-AC38Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures...

394

ACS | Open Energy Information  

Open Energy Info (EERE)

ACS ACS Jump to: navigation, search Name ACS Place Madrid, Spain Zip 28036 Sector Solar Product Madrid based construction company involved in the development of solar thermal projects. Coordinates 40.4203°, -3.705774° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.4203,"lon":-3.705774,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

395

AC | OpenEI  

Open Energy Info (EERE)

AC AC Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

396

Equipment  

Science Journals Connector (OSTI)

...circuit can be included which will return the system to its previous state when power has been restored after a power failure. (Panellit, Inc., Dept. 197) * AUXILIARY RECORKFR may be used with the manufacturer's infrared spectropho-tometers to provide...

JOSHUA STERN

1958-08-01T23:59:59.000Z

397

ETA-AC002  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 Revision 2 Effective March 1, 1997 "Control of Test Conduct" Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Jude M. Clark Approved by: _________________________________________________ Date: _______________ Donald B. Karner Procedure ETA-AC002 Revision 2 2 ©1997 Electric Transportation Applications All Rights Reserved TABLE OF CONTENTS 1.0 Objectives 3 2.0 Purpose 3 3.0 Documentation 3 4.0 Initial Conditions and Prerequisites 4 5.0 Personnel Qualifications 5 6.0 Activity Requirements 6 7.0 Supplemental Activity Requirements 8 8.0 Glossary 9 9.0 References 10 Procedure ETA-AC002 Revision 2 3 ©1997

398

ETA-AC006  

NLE Websites -- All DOE Office Websites (Extended Search)

6 6 Revision 2 Effective: March 1, 1997 Vehicle Verification Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Jude M. Clark Approved by: _________________________________________________ Date: ______________ Donald B. Karner ETA-AC006 Revision 2 2 ©1997 Electric Transportation Applications All Rights Reserved TABLE OF CONTENTS 1.0 Objectives 3 2.0 Purpose 3 3.0 Documentation 3 4.0 Initial Conditions and Prerequisites 4 5.0 Verification Requirements 5 6.0 Glossary 11 7.0 References 12 Appendices Appendix A - Manufacturer's Proposal Review Check List 13 Appendix B - Vehicle Receipt Check List 18 ETA-AC006 Revision 2 3

399

Covered Product Category: Imaging Equipment  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including imaging equipment, which is covered by the ENERGY STAR® program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

400

Commercial Equipment Testing Enforcement Policies  

Energy.gov (U.S. Department of Energy (DOE))

In an exercise of its enforcement discretion, under specific conditions, DOE will not perform assessment testing, verification testing, or enforcement testing on units of certain types of commercial equipment if the manufacturer distributes in commerce an otherwise identical unit that does not have that feature.

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Equipment Certification Requirements | Open Energy Information  

Open Energy Info (EERE)

Equipment Certification Requirements Equipment Certification Requirements Jump to: navigation, search Policies requiring renewable energy equipment to meet certain standards serve to protect consumers from buying inferior equipment. These requirements not only benefit consumers; they also protect the renewable energy industry by making it more difficult for substandard systems to reach the market. [1] Contents 1 Equipment Certification Incentives 2 References Equipment Certification Incentives CSV (rows 1 - 19) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Canada Oil and Gas Operations Act (Canada) Environmental Regulations Equipment Certification Fees Generating Facility Rate-Making Generation Disclosure Industry Recruitment/Support Safety and Operational Guidelines

402

Laboratory Equipment & Supplies | Sample Preparation Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment & Supplies Equipment & Supplies John Bargar, SSRL Scientist Equipment is available to serve disciplines from biology to material science. All laboratories contain the following standard laboratory equipment: pH meters with standard buffers, analytical balances, microcentrifuges, vortex mixers, ultrasonic cleaning baths, magnetic stirrers, hot plates, and glassware. Most laboratories offer ice machines and cold rooms. Specialty storage areas for samples include a -80 freezer, argon and nitrogen glove boxes, radiation contamination areas, inert atmosphere chambers, and cold rooms. For specific information please see: Equipment Inventory Checkout Equipment & Supplies To view equipment inventory by laboratory, refer to the following pages: Biology Chemistry & Material Science Laboratory 1 Inventory

403

Bulk Hauling Equipment for CHG  

NLE Websites -- All DOE Office Websites (Extended Search)

BULK HAULING EQUIPMENT FOR CHG BULK HAULING EQUIPMENT FOR CHG Don Baldwin Director of Product Development - Hexagon Lincoln HEXAGON LINCOLN TITAN(tm) Module System Compressed Hydrogen Gas * Capacity 250 bar - 616 kg 350 bar - 809 kg 540 bar - 1155 kg * Gross Vehicle Weight (with prime mover) 250 bar - 28 450 kg 350 bar - 30 820 kg 540 bar - 39 440 kg * Purchase Cost 250 bar - $510,000 350 bar - $633,750 540 bar - $1,100,000 Compressed Natural Gas * Capacity (250 bar at 15 C) - 7412 kg * GVW (With prime mover) - 35 250 kg * Purchase Cost (+/- 5%) - $510,000 HEXAGON LINCOLN TITAN(tm) V Magnum Trailer System Compressed Hydrogen Gas * Capacity 250 bar - 800 kg 350 bar - 1050 kg 540 bar - 1500 kg * Gross Vehicle Weight (with prime mover) 250 bar - 31 000 kg 350 bar - 34 200 kg 540 bar - 45 700 kg * Purchase Cost (+/-

404

BASIS Equipment | ORNL Neutron Sciences  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment Equipment BASIS Schematic Schematic of the SNS Backscattering Spectrometer. Helium dewer cooling a sample Helium dewer cooling a sample (bird's eye view). The heart of the work in a typical experiment is setting up the sample in the desired environment. A typical neutron sample ranging from a millimeter to a few centimeters is placed in a specialized cylindrical can and sealed. For liquids, the backscattering instrument often uses an annular can, created by placing a smaller can within a larger can and inserting the liquid sample between the two cans. This picture shows a helium dewer cooling the environment encompassing the sample can, which has been lowered into the beam from the top of the scattering tank. Crystals Crystals. The backscattering spectrometer is defined by the reflection of specific

405

Football facility and equipment management  

Science Journals Connector (OSTI)

The paper investigates the subject of football facility and equipment management to present the key success factors and planning elements for consideration. The work is based on secondary data analysis and literature review, and the findings include both descriptive and prescriptive elements. The findings construct a theoretical basis for further development and provide football managers with explicit and practical advice on the subject. They further indicate that topics pertaining to football facility and equipment management are not and should not be viewed as independent tasks under a common umbrella. They are all part of a larger system with all aspects interrelated both at the planning and the operation stages. Moreover, they are found to be inextricably linked with the wider strategic and marketing processes and constitute a significant part of the value proposition of the club to its immediate customers, implicit customers, industry associates and wider society.

Nicos L. Kartakoullis; Alkis Thrassou; Demetris Vrontis; Thanos Kriemadis

2013-01-01T23:59:59.000Z

406

Used energy-related laboratory equipment grant program for institutions of higher learning. Eligible equipment catalog  

SciTech Connect

This is a listing of energy related equipment available through the Energy-Related Laboratory Equipment Grant Program which grants used equipment to institutions of higher education for energy-related research. Information included is an overview of the program, how to apply for a grant of equipment, eligibility requirements, types of equipment available, and the costs for the institution.

Not Available

1994-07-01T23:59:59.000Z

407

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

408

Data:Fb354812-1c9c-4ac1-9b59-f904acbea6b3 | Open Energy Information  

Open Energy Info (EERE)

4812-1c9c-4ac1-9b59-f904acbea6b3 4812-1c9c-4ac1-9b59-f904acbea6b3 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Idaho Power Co Effective date: 2012/07/01 End date if known: Rate name: Schedule 7 - Small General Service Sector: Commercial Description: AVAILABILITY Service under this schedule is available at points on the Company's interconnected system within the State of Idaho where existing facilities of adequate capacity and desired phase and voltage are adjacent to the Premises to be served, and additional investment by the Company for transmission, substation, or terminal facilities is not necessary to supply the desired service.

409

Data:D0f4ac6d-44e2-4291-93ac-7bad270f8d9b | Open Energy Information  

Open Energy Info (EERE)

ac6d-44e2-4291-93ac-7bad270f8d9b ac6d-44e2-4291-93ac-7bad270f8d9b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Cooperative L&P Assn Lake Cnty Effective date: 2012/01/01 End date if known: Rate name: Heat Pumps Sector: Residential Description: Both Air-source and Ground-source heat pumps use either the dual fuel or general service rate, depending on if you install a back-up heating system. Note: General service rates apply until back up fuel system is installed and operational. Contact your local heating contractor for any equipment information. Source or reference: http://www.clpower.com/?p=14

410

Modulation and SSR tests performed on the BPA 500 kV thyristor controlled series capacitor unit at Slatt substation  

SciTech Connect

Field experience is reported for a thyristor controlled series capacitor (TCSC) recently commissioned at BPA`s Slatt substation. Subsynchronous resonance tests show that TCSC interactions with shaft dynamics of PGE`s Boardman steam generator are well understood and are effectively avoided by normal TCSC valve firing logic. Modulation tests, performed with the Boardman plant off line, show that the TCSC can be a powerful and responsive actuator for swing damping. Security considerations did not permit lightly damped operation of the controlled plant. Close analysis indicates that the TCSC damping contribution, though small, was measurable. The best estimate is that damping for the McNary mode is 7.33% and 8.55%, for the TCSC damper loop open and closed respectively. TCSC testing and monitoring is facilitated by an advanced interactive measurement network representing BPA`s approach to the information requirements of major control systems.

Hauer, J.F. [Pacific Northwest Lab., Richland, WA (United States)] [Pacific Northwest Lab., Richland, WA (United States); Mittelstadt, W.A. [Bonneville Power Administration, Portland, OR (United States)] [Bonneville Power Administration, Portland, OR (United States); Piwko, R.J. [General Electric Co., Schenectady, NY (United States)] [General Electric Co., Schenectady, NY (United States); Damsky, B.L. [Electric Power Research Inst., Palo Alto, CA (United States)] [Electric Power Research Inst., Palo Alto, CA (United States); Eden, J.D. [Portland General Electric, OR (United States)] [Portland General Electric, OR (United States)

1995-07-01T23:59:59.000Z

411

Modulation and SSR tests performed on the BPA 500 kV thyristor controlled series capacitor unit at Slatt substation  

SciTech Connect

Field experience is reported for a thyristor controlled series capacitor (TCSC) recently commissioned at BPA`s Slatt substation. Subsynchronous resonance tests show that TCSC interactions with shaft dynamics of PGE`s Boardman steam generator are well understood and are effectively avoided by normal TCSC valve firing logic. Modulation tests, performed with the Boardman plant off line, show that the TCSC can be a powerful and responsive actuator for swing damping. Security considerations did not permit lightly damped operation of the controlled plant. Close analysis indicates that the TCSC damping contribution, though small, was measurable. The best estimate is that damping for the McNary mode is 7.33% and 8.55%, for the TCSC damper loop open and closed respectively. TCSC testing and monitoring is facilitated by an advanced interactive measurement network representing BPA`s approach to the information requirements of major control systems.

Hauer, J.F. [Pacific Northwest Lab., Richland, WA (United States)] [Pacific Northwest Lab., Richland, WA (United States); Mittelstadt, W.A. [Bonneville Power Administration, Portland, OR (United States)] [Bonneville Power Administration, Portland, OR (United States); Piwko, R.J. [General Electric Co., Schenectady, NY (United States)] [General Electric Co., Schenectady, NY (United States); Damsky, B.L. [Electric Power Research Inst., Palo Alto, CA (United States)] [Electric Power Research Inst., Palo Alto, CA (United States); Eden, J.D. [Portland General Electric, OR (United States)] [Portland General Electric, OR (United States)

1996-05-01T23:59:59.000Z

412

Energy Conservation Program of the Division of Substation and Control Engineering : An Interim Report.  

SciTech Connect

Energy conservation projects undertaken by BPA that could benefit residential and commercial users and development of prototype equipment are described. Progress reports are presented and directions that the projects will take are indicated. The first projects presented are those being done at BPA's Midway Residential Community: studies on air infiltration and weatherization, and evaluation of such energy conservation measures as heat pump and solar water heaters. The next section involves an energy audit and retrofit program undertaken to reduce energy consumption in BPA's own buildings. The third section, also concerned with BPA's efforts to reduce internal energy consumption, presents the application of passive solar techniques to the design of new BPA buildings. The fourth section reports on a system developed to utilize waste thermal energy from transformers and solar energy for space heating and cooling. The fifth section also involves the development of a prototype system, one to monitor energy usage of industrial equipment. The final sections report on projects involving solar and wind energy, the Photovoltaic Applications Program, and the Mod-2 Wind Generator project at Goodnoe Hills. (MCW)

,

1981-04-01T23:59:59.000Z

413

Abatement of Air Pollution: Air Pollution Control Equipment and Monitoring Equipment Operation (Connecticut)  

Energy.gov (U.S. Department of Energy (DOE))

These regulations contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown, failure, and...

414

Fire suppression and detection equipment  

SciTech Connect

Inspection and testing guidelines go beyond the 'Code of Federal Regulation'. Title 30 of the US Code of Federal Regulations (30 CFR) contains requirements and references to national standards for inspection, testing and maintenance of fire suppression and detection equipment for mine operators. However, federal requirements have not kept pace with national standards and best practices. The article lists National Fire Protection (NFPA) standards that are referenced by the US Mine Safety and Health Administration (MSHA) in 30 CFR. It then discusses other NFPA Standards excluded from 30 CFR and explains the NFPA standard development process. 2 refs., 3 tabs., 5 photos.

E.E. Bates [HSB Professional Loss Control, Lexington, KY (United States)

2006-01-15T23:59:59.000Z

415

Laboratory Equipment Donation Program - Application Process  

Office of Scientific and Technical Information (OSTI)

Equipment listings on the LEDP web site are obtained from the U.S. General Equipment listings on the LEDP web site are obtained from the U.S. General Services Administration (GSA) Energy Asset Disposal System (EADS). Once equipment is listed, EADS allows 30 days for grantees from eligible institutions to apply for it on the LEDP site. Equipment Condition Codes are found near the top of the "LEDP Equipment Information" page for each item. The condition of equipment is graded as follows: 1: Unused Good Condition 4: Used Good Condition 7: Repairable Requires Repairs X: Salvage Salvage S: Scrap Scrap Specific questions concerning equipment should be directed to the point of contact responsible for the item(s) under consideration. This information is listed on the "Equipment Information" page, as well as on the grant

416

INL Equipment to Aid Regional Response Team  

NLE Websites -- All DOE Office Websites (Extended Search)

INL Equipment to Aid Regional Response Team DOE-ID is transferring equipment to the Idaho Falls Police Department's Hazardous Materials Response Team for their use in responding to...

417

Operations and Maintenance for Major Equipment Types  

Energy.gov (U.S. Department of Energy (DOE))

Equipment lies at the heart of all operations and maintenance (O&M) activities. This equipment varies greatly across the Federal sector in age, size, type, model, condition, etc.

418

Dental CBCT equipment and performance issues  

Science Journals Connector (OSTI)

......time due to insufficient dose audit data. For dental CBCT equipment...there are no large-scale audits of equipment in clinical use...http://ec.europa.eu/energy/nuclear/radiation_protection...http://ec.europa.eu/energy/nuclear/radioprotection......

K. Horner; R. Jacobs; R. Schulze

2013-02-01T23:59:59.000Z

419

Consider Steam Turbine Drives for Rotating Equipment  

Energy.gov (U.S. Department of Energy (DOE))

This tip sheet outlines the benefits of steam turbine drives for rotating equipment as part of optimized steam systems.

420

Solar Equipment Certification | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Equipment Certification Solar Equipment Certification Solar Equipment Certification < Back Eligibility Construction General Public/Consumer Savings Category Solar Buying & Making Electricity Heating & Cooling Water Heating Program Info State Florida Program Type Equipment Certification Provider Florida Solar Energy Center Under the Solar Energy Standards Act of 1976, the Florida Solar Energy Center (FSEC) is responsible for certifying all solar equipment sold in Florida. A manufacturer who wishes to have their solar equipment certified first contacts FSEC for an application and requests that FSEC test samples of the product at random. Equipment is then subjected to a series of tests in order to be approved or denied certification. Standards and applications procedures for specific technologies are available on the FSEC web site.

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Laboratory Equipment Donation Program - Contact Us  

Office of Scientific and Technical Information (OSTI)

End of Year Reports End of Year Reports At the end of the first year of using LEDP grant equipment, the grantee must provide DOE with a report on the use of the equipment. If a grantee does not submit a report, the DOE OPMO who approved the grant application can pull the equipment back, or not allow that institution to apply for more equipment. The report should describe: Any new courses instituted as a result of the grant of the equipment; Existing courses which have been expanded as a result of the grant of the equipment; Research activities, e.g., thesis titles, journals articles, sponsored research, etc.; and Other ways the equipment has been used to enhance courses, e.g., experiments, demonstrations, etc. If your item control Number starts with Send your report to 890565

422

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial and Industrial Pumps Commercial and Industrial Pumps Sign up for e-mail updates on regulations for this and other products Pumps are used in agriculture, oil and gas production, water and wastewater, manufacturing, mining, and commercial building systems. Currently there are no energy conservation standards for pumps. The Department of Energy (DOE) will conduct an analysis of the energy use, emissions, costs, and benefits associated with this equipment during the commercial and industrial pumps energy conservation standards rulemaking. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a notice of public meeting and availability of the framework document. 78 FR 7304 (Feb. 1, 2013). For more information, please see the rulemaking page.

423

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial and Industrial Compressors Determination Commercial and Industrial Compressors Determination Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) proposes to determine that commercial and industrial compressors meet the criteria for covered equipment under Part A-1 of Title III of the Energy Policy and Conservation Act (EPCA), as amended. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a Proposed Coverage Determination concerning commercial and industrial compressors. 77 FR 76972 (Dec. 31, 2012). Public Meeting Information No public meeting is scheduled at this time. Submitting Public Comments The comment period is closed.

424

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Alternative Efficiency Determination Methods and Alternate Rating Methods Alternative Efficiency Determination Methods and Alternate Rating Methods Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to revise and expand its existing regulations governing the use of alternative efficiency determination methods (AEDM) and alternate rating methods (ARM) for covered products as alternatives to testing for the purpose of certifying compliance. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule revising its existing regulations governing the use of particular methods as alternatives to testing for commercial heating, ventilating, air conditioning, water heating, and refrigeration equipment. 78 FR 79579 (December 31, 2013).

425

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Illuminated Exit Signs Illuminated Exit Signs Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of illuminated exit signs since 2005. Illuminated exit signs are used to indicate exit doors in schools, hospitals, libraries, government buildings, and commercial buildings of all kinds, including offices, restaurants, stores, auditoriums, stadiums, and movie theatres. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates There are no recent updates for this equipment. Standards for Illuminated Exit Signs The following content summarizes the energy conservation standards for illuminated exit signs. The text is not an official reproduction of the Code of Federal Regulations and should not be used for legal research or citation.

426

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Warm Air Furnaces Commercial Warm Air Furnaces Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of commercial warm air furnaces since 1994. Commercial warm air furnaces are self-contained oil-fired or gas-fired furnaces that are designed to supply heated air through ducts to spaces that require it. Commercial warm air furnaces are industrial equipment and have a maximum rated input capacity of 225,000 British thermal units (Btu) an hour or more. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a request for information regarding energy conservation standards for commercial warm air furnaces. 78 FR 25627 (May 2, 2013). For more information, please see the rulemaking webpage.

427

Appliance and Equipment Standards Program  

Energy.gov (U.S. Department of Energy (DOE))

The Building Technologies Office (BTO) implements minimum energy conservation standards for more than 50 categories of appliances and equipment. As a result of these standards, energy users saved about $55 billion on their utility bills in 2013. Since the beginning of 2009, 25 new or updated standards have been issued, which will help increase annual savings by more than 50 percent over the next decade. By 2030, cumulative operating cost savings from all standards in effect since 1987 will reach over $1.7 trillion, with a cumulative reduction of 6.8 billion tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 1.4 billion automobiles. Products covered by standards represent about 90% of home energy use, 60% of commercial building use, and 29% of industrial energy us

428

Benefits of Using Mobile Transformers and Mobile Substations for Rapidly Restoring Electrical Service: a Report to the United States Congress Pursuant to Section 1816 of the Energy Policy Act of 2005 (August 2006)  

Energy.gov (U.S. Department of Energy (DOE))

Section 1816 of EPACT calls for a report on the benefits of using mobile transformers and mobile substations (MTS) to rapidly restore electrical service to areas subjected to blackouts as a result...

429

Alternative Fuels at AC Transit  

NLE Websites -- All DOE Office Websites (Extended Search)

Alternative Fuels at AC Transit Alternative Fuels at AC Transit Speaker(s): Jaimie Levin Date: November 1, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Eve Edelson Mr. Levin will discuss AC Transit's range of environmental technology initiatives, including: zero emission fuel cell transit buses; state-of-the-art, high-capacity, hydrogen fueling stations; solar energy systems; and stationary solid oxide fuel cell power generators. AC Transit has the largest fleet of fuel cell buses in the United States, featuring fuel cell systems with more than 10,000 hours of continuous operation without any failures or power degradation. Their fuel cell fleet has logged more than 400,000 miles of service and carried in excess of one million passengers. Come hear what AC Transit has learned, where they're headed,

430

AC resistance measuring instrument  

DOE Patents (OSTI)

An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

Hof, P.J.

1983-10-04T23:59:59.000Z

431

Early Markets: Fuel Cells for Material Handling Equipment | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Material Handling Equipment Early Markets: Fuel Cells for Material Handling Equipment This fact sheet describes the use of hydrogen fuel cells to power material handling equipment...

432

Step 5b: Help Program Contractors Obtain the Necessary Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

b: Help Program Contractors Obtain the Necessary Equipment Step 5b: Help Program Contractors Obtain the Necessary Equipment In addition to equipment for installing energy...

433

Operations and Maintenance for Major Equipment Types | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Types Operations and Maintenance for Major Equipment Types Equipment lies at the heart of all operations and maintenance (O&M) activities. This equipment varies greatly...

434

Type B Accident Investigation of the Serious Personal Injury while Doble Testing at the Western Area Power Administration Hayden Substation, May 19, 1999  

Energy.gov (U.S. Department of Energy (DOE))

On May 19, 1999, at 10:31 a.m., four Western Area Power Administration (Western) employees were performing Doble testing on a circuit breaker at Hayden Substation in Routt County, Colorado. Three electricians were injured when the high-voltage lead (HVL) of the Doble test set encroached on the minimum approach distance to an energized part outside clearance boundaries, drawing arcing faults.

435

Better Buildings Alliance Equipment Performance Specifications  

NLE Websites -- All DOE Office Websites (Extended Search)

BBA Equipment Performance BBA Equipment Performance Specifications William Goetzler Navigant Consulting william.goetzler@navigant.com (781) 270 8351 April 4, 2013 Better Buildings Alliance BTO Program Review 2 | Building Technologies Office eere.energy.gov Project Overview The BBA Performance Specifications project provides information and tools to help BBA members and other commercial building owners/operators specify and purchase high efficiency equipment. - Ensures targeted technologies are of interest to end users and manufacturers

436

Better Buildings Alliance Equipment Performance Specifications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

BBA Equipment Performance BBA Equipment Performance Specifications William Goetzler Navigant Consulting william.goetzler@navigant.com (781) 270 8351 April 4, 2013 Better Buildings Alliance BTO Program Review 2 | Building Technologies Office eere.energy.gov Project Overview The BBA Performance Specifications project provides information and tools to help BBA members and other commercial building owners/operators specify and purchase high efficiency equipment. - Ensures targeted technologies are of interest to end users and manufacturers

437

Solar Equipment Certification | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Equipment Certification Solar Equipment Certification Solar Equipment Certification < Back Eligibility Commercial Construction Installer/Contractor Residential Savings Category Heating & Cooling Commercial Heating & Cooling Solar Heating Water Heating Program Info State Minnesota Program Type Equipment Certification Provider Minnesota Department of Commerce Minnesota law requires that all active solar space-heating and water-heating systems, sold, offered for sale, or installed on residential and commercial buildings in the state meet Solar Rating and Certification Corporation (SRCC) standards. Specifically, the rule references SRCC's "Operating Guidelines" pertaining to collector certification and system certification: OG-100 and OG-300, respectively. Local building officials

438

G129 S129 Equipment List Windbreaker  

E-Print Network (OSTI)

(optional) Water shoes (tevas or old tennis shoes) Gaitors (optional) COURSE EQUIPMENT*: Pocket or wrist operated) Bug Spray Deck of cards, musical instrument, Frisbee, etc (optional) * Textbooks should

Polly, David

439

PPP Equipment Corporation | Open Energy Information  

Open Energy Info (EERE)

Name: PPP Equipment Corporation Sector: Solar Product: PPP-E designs, produces and markets Chemical Vapor Deposition (CVD) reactors and converter systems producing high-purity...

440

Healthcare Energy: Spotlight on Medical Equipment  

Energy.gov (U.S. Department of Energy (DOE))

The Building Technologies Office conducted a healthcare energy end-use monitoring project for two sites. Read details about large medical imaging equipment energy results.

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Best Management Practice #11: Commercial Kitchen Equipment |...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

savings. Water-using commercial kitchen equipment include pre-rinse spray valves, wash tanks and sinks, commercial dishwashers, food steamers, steam kettles, commercial ice...

442

Equips Nucleares SA | Open Energy Information  

Open Energy Info (EERE)

SA Place: Madrid, Spain Zip: 28006 Sector: Services Product: ENSA is a Spanish nuclear components and nuclear services supply company. References: Equips Nucleares, SA1...

443

Reduce Radiation Losses from Heating Equipment  

Energy.gov (U.S. Department of Energy (DOE))

This tip sheet describes how to save process heating energy and costs by reducing expensive heat losses from industrial heating equipment, such as furnaces.

444

WEAR RESISTANT ALLOYS FOR COAL HANDLING EQUIPMENT  

E-Print Network (OSTI)

Proceedings of the Conference on Coal Feeding Systems, HeldWear Resistant Alloys for Coal Handling Equipment", proposalWear Resistant Alloys for Coal Handling Equi pment". The

Bhat, M.S.

2011-01-01T23:59:59.000Z

445

Computers, Electronics and Electrical Equipment (2010 MECS) ...  

Energy Savers (EERE)

Electronics and Electrical Equipment More Documents & Publications MECS 2006 - Computer, Electronics and Appliances Cement (2010 MECS) Glass and Glass Products (2010 MECS)...

446

CX-011832: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

to purchase equipment owned by Umatilla Electric Cooperative (UEC) within BPA's McNary Substation. BPA already maintains all of UEC's equipment in the substation under an...

447

Digital ac monitor  

DOE Patents (OSTI)

An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.

Hart, G.W.; Kern, E.C. Jr.

1987-06-09T23:59:59.000Z

448

Safeguarding Equipment and Protecting Employees from  

E-Print Network (OSTI)

Safeguarding Equipment and Protecting Employees from Amputations www.osha.gov Small Business Safety of Labor for Occupational Safety and Health #12;Safeguarding Equipment and Protecting Employees from Activities 9 Hazard Analysis 9 Controlling Amputation Hazards 9 Safeguarding Machinery 9 Primary Safeguarding

Colton, Jonathan S.

449

Electrical Equipment Inspection Program Electrical Safety  

E-Print Network (OSTI)

Electrical Equipment Inspection Program Electrical Safety SLAC-I-730-0A11A-001-R003 23 March 2005 Document Title: Electrical Equipment Inspection Program Original Publication Date: 19 January 2005 Revised Publication Date: 23 March 2005 (updated 29 November 2010) Department: Electrical Safety Document Number: SLAC

Wechsler, Risa H.

450

Office equipment energy use and trends  

SciTech Connect

Office information technologies are using an increasing amount of energy in commercial buildings. During recent forecasting hearings in California, the office equipment end use has been a major source of differences among forecasts of commercial sector energy use. Not only are there major differences in forecasted load growth resulting from the energy use of office equipment, but there are also differences in interpretations of historical and base-year estimates. Understanding office equipment energy use is particularly important because office equipment is widely believed to be the fastest growing electrical end use in the fastest growing sector. This report describes the development and application of a spreadsheet to estimate current and future energy use by office equipment. We define the term ``office equipment`` to mean information processing technologies used in buildings. The seven categories of office equipment relate to categories found in our analysis of utility surveys and industry sales reports. These seven categories of equipment are examined for eleven types of commercial buildings.

Piette, M.A.; Eto, J.H.; Harris, J.P.

1991-09-01T23:59:59.000Z

451

Office equipment energy use and trends  

SciTech Connect

Office information technologies are using an increasing amount of energy in commercial buildings. During recent forecasting hearings in California, the office equipment end use has been a major source of differences among forecasts of commercial sector energy use. Not only are there major differences in forecasted load growth resulting from the energy use of office equipment, but there are also differences in interpretations of historical and base-year estimates. Understanding office equipment energy use is particularly important because office equipment is widely believed to be the fastest growing electrical end use in the fastest growing sector. This report describes the development and application of a spreadsheet to estimate current and future energy use by office equipment. We define the term office equipment'' to mean information processing technologies used in buildings. The seven categories of office equipment relate to categories found in our analysis of utility surveys and industry sales reports. These seven categories of equipment are examined for eleven types of commercial buildings.

Piette, M.A.; Eto, J.H.; Harris, J.P.

1991-09-01T23:59:59.000Z

452

Definition: Equipment Health Sensor | Open Energy Information  

Open Energy Info (EERE)

Sensor Sensor Jump to: navigation, search Dictionary.png Equipment Health Sensor Monitoring devices that automatically measure and communicate equipment characteristics that are related to the 'health' and maintenance of the equipment. These characteristics can include, but are not limited to temperature, dissolved gas, and loading. These devices can also automatically generate alarm signals if the equipment characteristics reach critical or dangerous levels.[1] Related Terms sustainability References ↑ [www.smartgrid.gov/sites/default/files/pdfs/description_of_assets.pdf SmartGrid.gov 'Description of Assets'] An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Health_Sensor&oldid=502526

453

Registration, Force Protection Equipment Demonstration - May 2009 |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Registration, Force Protection Equipment Demonstration - May 2009 Registration, Force Protection Equipment Demonstration - May 2009 Registration, Force Protection Equipment Demonstration - May 2009 May 2009 Demonstrating commercially availale physical security/force protection soultions around the world The bombing of Khobar Towers in Saudi Arabia on 25 June 1996 revealed the need for continal vigilance and protection againist terrorist forces intent on harming US personnel and interests. The Chairman if the Joint Chiefs of Staff directed the Services to investigate COTS equipments solutions for physical security/force protection needs. The Office of the Under Secretary of Defense for Acquistion, Technology, and Logistics (OUSD {at&l}) tasked the Office of the US Army Product Manager, force Protection Systems (PM-FPS), to coordiante and facilitate a Force Protection Equipment

454

RMOTC - Field Information - Equipment and Facilities  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment & Facilities Equipment & Facilities Motor Grader at RMOTC Notice: As of July 15th 2013, the Department of Energy announced the intent to sell Naval Petroleum Reserve Number 3 (NPR3). The sale of NPR-3 will also include the sale of all equipment and materials onsite. A decision has been made by the Department of Energy to complete testing at RMOTC by July 1st, 2014. RMOTC will complete testing in the coming year with the currently scheduled testing partners. For more information on the sale of NPR-3 and sale of RMOTC equipment and materials please join our mailing list here. RMOTC's test facility has its own line of workover, support, and heavy equipment available for partner use on site. RMOTC can also offer its partners workspace on site in its Customer Operations Center which has

455

Office Buildings - End-Use Equipment  

U.S. Energy Information Administration (EIA) Indexed Site

End-Use Equipment End-Use Equipment The types of space heating equipment used in office buildings were similar to those of the commercial buildings sector as a whole (Table 8 and Figure 5). Furnaces were most used followed by packaged heating systems. Individual space heaters were third-most used but were primarily used to supplement the building's main heating system. Boilers and district heat systems were more often used in larger buildings. Table 8. Types of Heating Equipment Used in Office Buildings, 2003 Number of Buildings (thousand) Total Floorspace (million square feet) All Buildings* All Office Buildings All Buildings* All Office Buildings All Buildings 4,645 824 64,783 12,208 All Buildings with Space Heating 3,982 802 60,028 11,929 Heating Equipment (more than one may apply)

456

CVD Equipment Corp | Open Energy Information  

Open Energy Info (EERE)

CVD Equipment Corp CVD Equipment Corp Jump to: navigation, search Name CVD Equipment Corp Place Ronkonkoma, New York Zip 11779 Sector Solar Product New York-based maker of chemical vapour deposition process equipment. This equipment is used in the manufacture of solar and semiconductor fabrication. Coordinates 40.81122°, -73.098744° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.81122,"lon":-73.098744,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

457

Definition: Disturbance Monitoring Equipment | Open Energy Information  

Open Energy Info (EERE)

Disturbance Monitoring Equipment Disturbance Monitoring Equipment Jump to: navigation, search Dictionary.png Disturbance Monitoring Equipment Devices capable of monitoring and recording system data pertaining to a Disturbance. Such devices include the following categories of recorders: Sequence of event recorders which record equipment response to the event., Fault recorders, which record actual waveform data replicating the system primary voltages and currents. This may include protective relays., Dynamic Disturbance Recorders (DDRs), which record incidents that portray power system behavior during dynamic events such as low-frequency (0.1 Hz - 3 Hz) oscillations and abnormal frequency or voltage excursions. Phasor Measurement Units and any other equipment that meets the functional requirements of DMEs may qualify as DMEs.[1]

458

Laboratory Equipment Donation Program - About Us  

Office of Scientific and Technical Information (OSTI)

About LEDP About LEDP The Laboratory Equipment Donation Program (LEDP), formerly the Energy-Related Laboratory Equipment (ERLE) Grant Program, was established by the United States Department of Energy (DOE) to grant surplus and available used energy-related laboratory equipment to universities and colleges in the United States for use in energy oriented educational programs. This grant program is sponsored by the Office of Workforce Development for Teachers and Scientists (WDTS). The listing of equipment available through LEDP is updated as new equipment is identified. It is available at no cost for a limited time and is granted on a first-received qualified application basis. Specific items may be recalled for DOE use and become unavailable through the program after the

459

Experimental Equipment | Stanford Synchrotron Radiation Lightsource  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment Equipment SSRL plans the distribution of its limited equipment on the basis of the information supplied on the Beam Time Request Form and the User Support Requirements Form. Please make sure to state all of your needs. Standard X-Ray Station Equipment Standard equipment to be found on an x-ray station includes: (1 ea.) Small and large ionization chambers (1) Exit slits (1) X-Y sample positioner (3) Keithly 427 current-to-voltage amplifier TEK 2215 60 MHZ 2 channel scope Voltage-to-frequency converter (3 channels) (1) Fluke high voltage power supply (1) Kinetic Systems hex scaler (1) Kinetic Systems up-down presettable counter (1) Ortec real-time clock (2) Joerger stepping motor controller DSP Micro VAX or Kinetic Systems G.I./CAMAC crate controller (1) Standard Engineering Corporation CAMAC power supply

460

Automatic monitoring of vibration welding equipment  

DOE Patents (OSTI)

A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

2014-10-14T23:59:59.000Z

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Universal null DTE (data terminal equipment)  

DOE Patents (OSTI)

A communication device in the form of data terminal equipment permits two data communication equipments, each having its own master clock and operating at substantially the same nominal clock rate, to communicate with each other in a multi-segment circuit configuration of a general communication network even when phase or frequency errors exist between the two clocks. Data transmitted between communication equipments of two segments of the communication network is buffered. A variable buffer fill circuit is provided to fill the buffer to a selectable extent prior to initiation of data output clocking. Selection switches are provided to select the degree of buffer preload. A dynamic buffer fill circuit may be incorporated for automatically selecting the buffer fill level as a function of the difference in clock frequencies of the two equipments. Controllable alarm circuitry is provided for selectively generating an underflow or an overflow alarm to one or both of the communicating equipments. 5 figs.

George, M.; Pierson, L.G.; Wilkins, M.E.

1987-11-09T23:59:59.000Z

462

Definition: Equipment Condition Monitor | Open Energy Information  

Open Energy Info (EERE)

Condition Monitor Condition Monitor Jump to: navigation, search Dictionary.png Equipment Condition Monitor A monitoring device that automatically measures and communicates equipment characteristics that are related to the "health" and maintenance of the equipment. These characteristics can include, but are not limited to temperature, dissolved gas, and loading. These devices can automatically generate alarm signals if conditions exceed preset thresholds.[1] Related Terms sustainability References ↑ https://www.smartgrid.gov/category/technology/equipment_condition_monitor [[C LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ategory: Smart Grid Definitions|Template:BASEPAGENAME]] Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Condition_Monitor&oldid=502601"

463

Appliances and Commercial Equipment Standards: Guidance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office Office HOME ABOUT ENERGY EFFICIENT TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE » Building Technologies Office » Appliances & Equipment Standards About Standards & Test Procedures Implementation, Certification & Enforcement Rulemakings & Notices Further Guidance ENERGY STAR® Guidance and Frequently Asked Questions This webpage is designed to provide guidance and answer Frequently Asked Questions (FAQs) on the U.S. Department of Energy's appliance standards program. Guidance types span all covered products and covered equipment and cover such topics as: definitions, scope of coverage, conservation standards, test procedures, certification, Compliance and Certification Management System (CCMS), and enforcement. This website offers users an

464

Long Length Contaminated Equipment Maintenance Plan  

SciTech Connect

The purpose of this document is to provide the maintenance requirements of the Long Length Contaminated Equipment (LLCE) trailers and provide a basis for the maintenance frequencies selected. This document is applicable to the LLCE Receiver trailer and Transport trailer assembled by Mobilized Systems Inc. (MSI). Equipment used in conjunction with, or in support of, these trailers is not included. This document does not provide the maintenance requirements for checkout and startup of the equipment following the extended lay-up status which began in the mid 1990s. These requirements will be specified in other documentation.

ESVELT, C.A.

2000-02-01T23:59:59.000Z

465

Incidents of chemical reactions in cell equipment  

SciTech Connect

Strongly exothermic reactions can occur between equipment structural components and process gases under certain accident conditions in the diffusion enrichment cascades. This paper describes the conditions required for initiation of these reactions, and describes the range of such reactions experienced over nearly 50 years of equipment operation in the US uranium enrichment program. Factors are cited which can promote or limit the destructive extent of these reactions, and process operations are described which are designed to control the reactions to minimize equipment damage, downtime, and the possibility of material releases.

Baldwin, N.M.; Barlow, C.R. [Uranium Enrichment Organization, Oak Ridge, TN (United States)

1991-12-31T23:59:59.000Z

466

NAFTA opportunities: Electrical equipment and power generation  

SciTech Connect

The North American Free Trade Agreement (NAFTA) provides significant commercial opportunities in Mexico and Canada for the United States electric equipment and power generation industries, through increased goods and services exports to the Federal Electricity Commission (CFE) and through new U.S. investment in electricity generation facilities in Mexico. Canada and Mexico are the United States' two largest export markets for electrical equipment with exports of $1.53 billion and $1.51 billion, respectively, in 1992. Canadian and Mexican markets represent approximately 47 percent of total U.S. exports of electric equipment. The report presents an economic analysis of the section.

Not Available

1993-01-01T23:59:59.000Z

467

An Evaluation of the Total Cost of Ownership of Fuel Cell-Powered Material Handling Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Evaluation of the Total Cost Evaluation of the Total Cost of Ownership of Fuel Cell- Powered Material Handling Equipment Todd Ramsden National Renewable Energy Laboratory Technical Report NREL/TP-5600-56408 April 2013 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 15013 Denver West Parkway Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 An Evaluation of the Total Cost of Ownership of Fuel Cell- Powered Material Handling Equipment Todd Ramsden National Renewable Energy Laboratory Prepared under Task No. HT12.8610 Technical Report NREL/TP-5600-56408

468

Definition: Equipment Rating | Open Energy Information  

Open Energy Info (EERE)

Rating Rating Jump to: navigation, search Dictionary.png Equipment Rating The maximum and minimum voltage, current, frequency, real and reactive power flows on individual equipment under steady state, short-circuit and transient conditions, as permitted or assigned by the equipment owner.[1] Also Known As Standard current ratings Related Terms reactive power, smart grid References ↑ Glossary of Terms Used in Reliability Standards An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Rating&oldid=502535" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties

469

Piedmont Natural Gas - Residential Equipment Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Piedmont Natural Gas - Residential Equipment Efficiency Program Piedmont Natural Gas - Residential Equipment Efficiency Program Piedmont Natural Gas - Residential Equipment Efficiency Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Maximum Rebate 2 rebates per household Program Info State North Carolina Program Type Utility Rebate Program Rebate Amount High-Efficiency Furnace: $175 Tankless Water Heater: $150 Tank Water Heater: $50 Provider Gas Technology and Energy Services Piedmont Natural Gas offers rebates on high-efficiency natural gas tankless water heaters, tank water heaters and furnaces. Customers on the 101-Residential Service rate are eligible for these rebates. Rebates are only provided for qualifying natural gas equipment that is installed to

470

Laboratory Equipment Donation Program - Home Page  

NLE Websites -- All DOE Office Websites (Extended Search)

U.S. Department of Energy U.S. Department of Energy Laboratory Equipment Donation Program Home About LEDP FAQ Application Site Index Contact Us Administrative Login SEARCH: Go! view equipment list LEDP News Latest Equipment Added as of January 08, 2014: 1. DATA HANDLING SYSTEM 89514133530195 2. METER, VOLT 89514133530179 3. RECORDER, STRIP 89514133530184 4. RECORDER, STRIP 89514133530185 5. SCINTILLATOR STRIPS, 1.9 CM X 1.5 CM X 96 CM 89514133530188 Quick Links What type of equipment is available? Who is eligible to apply? How long will it take to find out if my application has been approved? Who is responsible for arranging and paying for shipping? RSS Get Widgets Bookmark and Share Get the tools you need to inspire innovation and creativity The United States Department of Energy (DOE), in accordance with its

471

Energy Sub-Metering Equipment and Applications  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Sub-Metering Equipment and Applications Energy Sub-Metering Equipment and Applications Speaker(s): Sim Gurewitz Date: July 24, 2008 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Paul Mathew This talk will address the following topics:Submetering basics: What is it? How does a submeter work?How to obtain a finer level of energy information within the buildingApplications: Who submeters and why?LEED NC/EB/CS and submetering / Energy & Atmosphere pointsSubmetering equipment: gas, electric, water, steam, CW Btu and HHW BtuHow to install equipment without scheduling an outageLoad Control option for automated load shedding and peak shavingWireless submeters and communication options / integration to EMS-BMCSAutomatic remote meter reading and cost allocation softwarePutting it all together into a metering SYSTEM: read from anywhere, IP

472

HVAC Equipment Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Equipment Rebate Program HVAC Equipment Rebate Program HVAC Equipment Rebate Program < Back Eligibility Agricultural Commercial Industrial Installer/Contractor Institutional Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Maximum Rebate Rebates of greater than $5,000 require pre-approval Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies depending on technology and efficiency Provider Efficiency Vermont NOTE: Rebate reservations are required for all boiler and furnace projects. Efficiency Vermont offers rebates for commercial installations of high-efficiency HVAC equipment and controls. For businesses and purchases

473

Industrial Equipment Demand and Duty Factors  

E-Print Network (OSTI)

Demand and duty factors have been measured for selected equipment (air compressors, electric furnaces, injection molding machines, centrifugal loads, and others) in industrial plants. Demand factors for heavily loaded air compressors were near 100...

Dooley, E. S.; Heffington, W. M.

474

BCM 2 Equipment Inventory | Sample Preparation Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

& Material Science Laboratory 2 Title Equipment Type Description Accumet Basic AB15 pH meter pH Meter pH meters with combination AgAgCl electrode and ATC probe. Corning 430 pH...

475

UNIVERSITY OF WASHINGTON ANNUAL EQUIPMENT TESTING AND  

E-Print Network (OSTI)

UNIVERSITY OF WASHINGTON ANNUAL EQUIPMENT TESTING AND MAINTENANCE SUMMARY DIVING SAFETY PROGRAM Date Tested Condition when received Intermediate Pressure Inhalation Resistance Exhalation Resistance Tested Make Serial Number Date Tested Results DEPTH GAUGE BUOYANCY COMPENSATOR Make Serial Number Date

Wilcock, William

476

Safety Topic: Rota/ng Equipment  

E-Print Network (OSTI)

Safety Topic: Rota/ng Equipment Jus/n Kleingartner #12;Safety protocols 2 #12;Safety protocols for opera/ng a lathe · Don'ts: ­ Do not wear gloves

Cohen, Robert E.

477

An Approach to Evaluating Equipment Efficiency Policies  

E-Print Network (OSTI)

AN APPROACH TO EVALUATING EQUIPMENT EFFICIENCY POLICIES Donald E. Newsom, Ph.D. and Allan R. Evans, Ph.D., P.E. Argonne National Laboratory, Argonne, Illinois ABSTRACT The National Energy Conservation Policy Act of 1978 authorized studies...

Newsom, D. E.; Evans, A. R.

1980-01-01T23:59:59.000Z

478

Cruising Equipment Company CECO | Open Energy Information  

Open Energy Info (EERE)

Cruising Equipment Company CECO Cruising Equipment Company CECO Jump to: navigation, search Name Cruising Equipment Company (CECO) Place Seattle, Washington Zip 98107 Product Maker of pollution control equipment - bought by Xantrex in 2000. Coordinates 47.60356°, -122.329439° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":47.60356,"lon":-122.329439,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

479

Computer optimization of earthmoving equipment arrays  

E-Print Network (OSTI)

higher degree of equipment specialization. Thus, the con- tractor attempts now to insure that individual segments of jobs are performed by the most economical means available to him. The choice of equipment to be used is difficult indeed... drawn carts. Next came use of the drag scraper followed by a wheel-mounted scraper which could dig, transport and dump its load. A major contribution to the earthmoving industry was the track-type tractor, which was developed in 1904. The potential...

Pate, Jep Earl

2012-06-07T23:59:59.000Z

480

List of Agricultural Equipment Incentives | Open Energy Information  

Open Energy Info (EERE)

Agricultural Equipment Incentives Agricultural Equipment Incentives Jump to: navigation, search The following contains the list of 90 Agricultural Equipment Incentives. CSV (rows 1 - 90) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Agricultural Energy Efficiency Program (New York) State Rebate Program New York Agricultural Agricultural Equipment Boilers Chillers Custom/Others pending approval Dishwasher Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Food Service Equipment Yes Agricultural Lighting and Equipment Rebate Program (Vermont) State Rebate Program Vermont Agricultural Agricultural Equipment Custom/Others pending approval Lighting

Note: This page contains sample records for the topic "ac substation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

CRAD, Nuclear Facility Construction - Mechanical Equipment - June 26, 2012  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nuclear Facility Construction - Mechanical Equipment - June Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 CRAD, Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 June 26, 2012 Nuclear Facility Construction - Mechanical Equipment Installation, (HSS CRAD 45-53, Rev. 0) The purpose of this criteria review and approach, this CRAD includes mechanical equipment installation, including connections of the equipment to installed piping systems, and attachments of the equipment to structures (concrete, structural steel, or embed plates). Mechanical equipment includes items such as pumps and motors, valves, tanks, glove boxes, heat exchangers, ion exchangers, service air system, fire pumps and tanks, and heating, ventilation, and air condition (HVAC) equipment such as fans, scrubbers and filters.

482

Alternative Fuels Data Center: Pollution Control Equipment Exemption  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Pollution Control Pollution Control Equipment Exemption to someone by E-mail Share Alternative Fuels Data Center: Pollution Control Equipment Exemption on Facebook Tweet about Alternative Fuels Data Center: Pollution Control Equipment Exemption on Twitter Bookmark Alternative Fuels Data Center: Pollution Control Equipment Exemption on Google Bookmark Alternative Fuels Data Center: Pollution Control Equipment Exemption on Delicious Rank Alternative Fuels Data Center: Pollution Control Equipment Exemption on Digg Find More places to share Alternative Fuels Data Center: Pollution Control Equipment Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Pollution Control Equipment Exemption Dedicated original equipment manufacturer natural gas vehicles and

483

ACS calibration pipeline testing: error propagation  

E-Print Network (OSTI)

1 ACS calibration pipeline testing: error propagation Doug Van Orsow, Max Mutchler, Warren Hack files (see ISRs 99-03 "CALACS Operation and Implementation" by Hack and 99-04 "ACS calibra- tion

Sirianni, Marco

484

ACS SYMPOSIUM SERIES 966 Rational Environmental  

E-Print Network (OSTI)

ACS SYMPOSIUM SERIES 966 Rational Environmental Management of Agrochemicals Risk Assessment-Bayo, Editor Chiha University Sponsored by the ACS Division of Agrochemicals American Chemical Society of agrochemicals : risk assessment, monitoring, and remedial action / Ivan R. Kennedy, editor. ..[et al

Hammock, Bruce D.

485

ACS_RRA_2001.PDF  

NLE Websites -- All DOE Office Websites (Extended Search)

Qualitative and Semi-quantitative Qualitative and Semi-quantitative Analysis Of Semi-volatile Organics from Ambient Air Fine-particulate Matter, PM 2.5 Richard Anderson, Don Martello, Brian R. Strazisar and Curt M. White richard.anderson@netl.doe.gov ACS-222 / RRA' / ST-10 / 8-28-2001 Different Missions * EPA - Protect the public health * DOE - Assist the private sector in supplying clean, abundant, and affordable energy ACS-222 / RRA' / ST-10 / 8-28-2001 PM 2.5 Regulatory Process * 1997 National Ambient Air Quality Standards (NAAQS) for PM 2.5 based on "health effects" - Mean annual concentration < 15 µg/m 3 - Maximum concentration < 65µg/ m 3 ACS-222 / RRA' / ST-10 / 8-28-2001 Why Is DOE Concerned About PM 2.5 ? * Coal-based power systems contribute to PM 2.5 - Primary particles * Ultra-fine fly-ash (Spherical Alumino-silicates,SAS), carbon soot

486

Electricity Used by Office Equipment and Network Equipment in the U.S.: Detailed Report and Appendices  

E-Print Network (OSTI)

LBNL-45917 Electricity Used by Office Equipment and Network Equipment in the U.S.: Detailed Report..............................................................................................46 #12;#12;1 Electricity Used by Office Equipment and Network Equipment in the U.S. Kaoru Kawamoto and network equipment, there has been no recent study that estimates in detail how much electricity

487

1982 analyses and reports: equipment availability report; component cause code report; and equipment availability report  

SciTech Connect

This equipment availability report (1973 to 1982, 1982) presents statistical information on the performance of the major types of generating units and their major component groups. (DLC)

Not Available

1982-01-01T23:59:59.000Z

488

CD54AC08, CD74AC08 QUADRUPLE 2-INPUT POSITIVE-AND GATES  

E-Print Network (OSTI)

SOIC M Tube CD74AC08M AC08M­55°C to 125°C SOIC ­ M Tape and reel CD74AC08M96 AC08M CDIP ­ F Tube CD54AC-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

489

Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Ethanol Production Ethanol Production Equipment Tax Exemption to someone by E-mail Share Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Facebook Tweet about Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Twitter Bookmark Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Google Bookmark Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Delicious Rank Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Digg Find More places to share Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Ethanol Production Equipment Tax Exemption

490

Novel Energy Conversion Equipment for Low Temperature Geothermal...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Novel Energy Conversion Equipment for Low Temperature Geothermal Resources Novel Energy Conversion Equipment for Low Temperature Geothermal Resources Project objective: Develop...

491

Dispensing Equipment Testing With Mid-Level Ethanol/Gasoline...  

Energy Savers (EERE)

Dispensing Equipment Testing With Mid-Level EthanolGasoline Test Fluid Dispensing Equipment Testing With Mid-Level EthanolGasoline Test Fluid The National Renewable Energy...

492

NSLS Services | Repair & Equipment Services  

NLE Websites -- All DOE Office Websites (Extended Search)

Repair & Equipment Services Repair & Equipment Services Cleaning Facility (BNL Central Shops) Solvent cleaning of vacuum parts and leak checking service is also available. Work is billed to each user via a BNL ILR. Contact the NSLS Building Manager to arrange for any of these services. Electronics Repair Limited repairs for electronic equipment are available from an outside contractor through the Control Room. Contact Control Room Supervisor Randy Church (x2550 or x2736, pager 5310). Shipping memos are filled out on the web, and pick ups are on Fridays. Come to the Control Room for assistance. The user should call the contractor on the day before scheduled pickups to alert the contractor of the pickup. Items to be repaired should be left in the Control Room with the completed shipping memo. Costs are charged to the

493

dieSel/heAvy equipMent College of Rural and Community Development  

E-Print Network (OSTI)

and equipment overhauls. Students work on large truck fuel, electrical and air systems, diesel engines 907-455-2809 www.ctc.uaf.edu/programs/diesel/ certificate Minimum Requirements for Certificate: 36 credits The diesel and heavy equipment mechanics program offers the student training in the maintenance

Hartman, Chris

494

After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-Load Equipment  

E-Print Network (OSTI)

LBNL-53729 After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-Load To download this paper and related data go to: http://enduse.lbl.gov/Projects/OffEqpt.html The work described.................................................................................................................................................5 Office Equipment Data Collection

495

Diary of Societies  

Science Journals Connector (OSTI)

... . Poynder: Some Practical Considerations in the Design of the Automatic Equipments for Heavy Traction Substations.

1928-01-28T23:59:59.000Z

496

Conceptual design report, CEBAF basic experimental equipment  

SciTech Connect

The Continuous Electron Beam Accelerator Facility (CEBAF) will be dedicated to basic research in Nuclear Physics using electrons and photons as projectiles. The accelerator configuration allows three nearly continuous beams to be delivered simultaneously in three experimental halls, which will be equipped with complementary sets of instruments: Hall A--two high resolution magnetic spectrometers; Hall B--a large acceptance magnetic spectrometer; Hall C--a high-momentum, moderate resolution, magnetic spectrometer and a variety of more dedicated instruments. This report contains a short description of the initial complement of experimental equipment to be installed in each of the three halls.

NONE

1990-04-13T23:59:59.000Z

497

M2ACS | M2ACS Web Space  

NLE Websites -- All DOE Office Websites (Extended Search)

Welcome to the Multifaceted Mathematics for Complex Energy Systems (M2ACS) Welcome to the Multifaceted Mathematics for Complex Energy Systems (M2ACS) project webspace We are a multi-institution project whose aim is to fully explore the opportunities in applied mathematics brought about by multi-disciplinary focus - involving optimization, dynamical systems, stochastic analysis, discrete mathematics, scalable algorithms - on the DOE Grand Challenge of energy systems. The central research concept is the one of multi-faceted mathematics - whereby new mathematics is discovered by sustained investigation of the multiple facets presented by the grand challenge subproblems, such as nonconvexity, stochasticity, integrality, spatio-temporal variability - from the perspective of all the mathematics discipline area involved. Our project involves 22 principal investigators from 3 national

498

Asset Management Equipment Disposal Form -Refrigerant Recovery  

E-Print Network (OSTI)

enters the waste stream with the charge intact (e.g., motor vehicle air conditioners, refrigeratorsAsset Management Equipment Disposal Form - Refrigerant Recovery Safe Disposal Requirements Under refrigeration, cold storage warehouse refrigeration, chillers, and industrial process refrigeration) has to have

Sin, Peter

499

WAMPANOAG WELLNESS EQUIPMENT LENDING BANK POLICIES & PROCEDURES  

E-Print Network (OSTI)

vacuums and steam cleaners, can be used to address immediate concerns, such as intense cleaning to remove to enable the Health Service to measure the environmental impact of the use of the equipment in the homes moisture levels or improve air quality. STEP TWO: RECOMMENDATIONS As noted, recommendations in the Home

500

Research equipment: Surface Acoustic Wave (SAW) devices  

E-Print Network (OSTI)

of the acoustic wave. More specifically, the equipment consists of: i. HP 4195A (10Hz-500MHz) ii. HP 8753ES (30kHz measurements on many SAW devices iii. Agilent E5061A (300kHz-1.5GHz) http Scientific Corp.): Atmospheric plasma etching, for surface cleaning, surface treatment and activation

Gizeli, Electra