Powered by Deep Web Technologies
Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Most efficient quantum thermoelectric at finite power output  

E-Print Network (OSTI)

Machines are only Carnot efficient if they are reversible, but then their power output is vanishingly small. Here we ask, what is the maximum efficiency of an irreversible device with finite power output? We use a nonlinear scattering theory to answer this question for thermoelectric quantum systems; heat engines or refrigerators consisting of nanostructures or molecules that exhibit a Peltier effect. We find that quantum mechanics places an upper bound on both power output, and on the efficiency at any finite power. The upper bound on efficiency equals Carnot efficiency at zero power output, but decays with increasing power output. It is intrinsically quantum (wavelength dependent), unlike Carnot efficiency. This maximum efficiency occurs when the system lets through all particles in a certain energy window, but none at other energies. A physical implementation of this is discussed, as is the suppression of efficiency by a phonon heat flow.

Robert S. Whitney

2014-03-13T23:59:59.000Z

2

Relationship Among Efficiency and Output Power of Heat Energy Converters  

E-Print Network (OSTI)

Relationship among efficiency and output power of heat-electric energy converters as well as of any converters for transforming of heat energy into any other kind of energy is considered. It is shown, that the parameter efficiency does not determine univocally the output power of a converter. It is proposed to use another parameter for determination of working ability of heat energy converters. It is shown, that high output power can not be achieved by any kind of Stirling-type converters in spite of their high efficiency.

Alexander Luchinskiy

2004-09-02T23:59:59.000Z

3

Efficiency Ratings for the Daiken AC (Americas), Inc.  

E-Print Network (OSTI)

Efficiency Ratings for the Daiken AC (Americas), Inc. Altherma Air-to-Water Source Heat Pump System Description Model No. Capacity (tons) Space Heating Space Cooling SEER Water Heating Efficiency (E.F.)1 CEC Listing Date Heating Combined Hydronic HSPF E.F. Split Altherma LT ERLQ036

4

Output, efficiency, emissions improved with Cat's 3500 series B engine  

SciTech Connect

Like most technologies, engine developments tend to follow evolutionary paths. And it's a given that the longer an engine's been around and the more successful it's been, the more likely it is that any changes made would be incremental. On the surface, such is the case with the Caterpillar 3500 Series B diesel engine, recently introduced in Europe and the United States. Based on the well-proven 3500 engine first introduced in 1980 and upgraded with a Phase II program five years later, most of the changes appear incremental. But taken as a whole, they provide a level of performance and durability that Caterpillar anticipates will make this engine an even stronger contender in power generation and marine applications for years to come. It's not hard to see why. Output has been increased between 17% and 30% on some models; fuel consumption is improved by as much as 15%; and with the new aftertreatment system introduced with the engines, emissions as low as 1.3 g/kWh NO[sub x] are said to be achieveable. This paper outlines the design, specifications, and highlights of the improvements in performance of these new engines. 3 figs.

Brezonick, M.

1995-03-01T23:59:59.000Z

5

Finding the quantum thermoelectric with maximal efficiency and minimal entropy production at given power output  

E-Print Network (OSTI)

We investigate the nonlinear scattering theory for quantum systems with strong Seebeck and Peltier effects, and consider their use as heat-engines and refrigerators with finite power outputs. This article gives detailed derivations of the results summarized in Phys. Rev. Lett. 112, 130601 (2014). It shows how to use the scattering theory to find (i) the quantum thermoelectric with maximum possible power output, and (ii) the quantum thermoelectric with maximum efficiency at given power output. The latter corresponds to a minimal entropy production at that power output. These quantities are of quantum origin since they depend on system size over electronic wavelength, and so have no analogue in classical thermodynamics. The maximal efficiency coincides with Carnot efficiency at zero power output, but decreases with increasing power output. This gives a fundamental lower bound on entropy production, which means that reversibility (in the thermodynamic sense) is impossible for finite power output. The suppression of efficiency by (nonlinear) phonon and photon effects is addressed in detail; when these effects are strong, maximum efficiency coincides with maximum power. Finally, we show in particular limits (typically without magnetic fields) that relaxation within the quantum system does not allow the system to exceed the bounds derived for relaxation-free systems, however a general proof of this remains elusive.

Robert S. Whitney

2015-01-28T23:59:59.000Z

6

Is it viable to improve light output efficiency by nano-light-emitting diodes?  

SciTech Connect

Nanopillar arrays with InGaN/GaN multiple-quantum-disks (MQDs) are fabricated by focused-ion-beam milling with surface damage layer removed by KOH wet etching. Nano-light-emitting diodes (Nano-LEDs) made of the InGaN/GaN MQD nanopillars are found to have 19.49% less output power than that of a conventional LED. The reasons are analyzed in detail and considering their current-voltage and electroluminescence characteristics, internal quantum efficiency, external quantum efficiency, light extraction, and wall-plug efficiency. Our results suggest that nanopillar-LED can outperform if the density can be increased to 2.81?Ś?10{sup 9}?cm{sup ?2} with the size unchanged or the size can be increased to 854.4?nm with the density unchanged.

Wang, Chao-Hung; Huang, Yu-Wen [Department of Materials Science and Engineering, National Cheng Kung University, Tainan 70101, Taiwan (China)] [Department of Materials Science and Engineering, National Cheng Kung University, Tainan 70101, Taiwan (China); Wu, Shang-En [Genesis Photonics Incorporation, Tainan 70101, Taiwan (China)] [Genesis Photonics Incorporation, Tainan 70101, Taiwan (China); Liu, Chuan-Pu, E-mail: cpliu@mail.ncku.edu.tw [Department of Materials Science and Engineering, National Cheng Kung University, Tainan 70101, Taiwan (China) [Department of Materials Science and Engineering, National Cheng Kung University, Tainan 70101, Taiwan (China); Center for Micro/Nano Science and Technology, National Cheng Kung University, Tainan 70101, Taiwan (China); Research Center for Energy Technology and Strategy, National Cheng Kung University, Tainan 70101, Taiwan (China)

2013-12-02T23:59:59.000Z

7

GAMS program used to estimate capacity with the hyperbolic graph efficiency measure, with constant returns to scale and undesirable outputs.  

E-Print Network (OSTI)

. "Estimating Capacity and Efficiency in Fisheries with Undesirable Outputs." VIMS Marine resource Report N(obs) weights gamma(obs,var) ; POSITIVE Variable weight, gamma; EQUATIONS CONSTR1(GOUTPUT, OBS) DEA constraint

8

GAMS program used to estimate capacity with the hyperbolic graph efficiency measure, with variable returns to scale and undesirable outputs.  

E-Print Network (OSTI)

. "Estimating Capacity and Efficiency in Fisheries with Undesirable Outputs." VIMS Marine resource Report N(obs) weights gamma(obs,var) ; POSITIVE Variable weight, gamma; EQUATIONS CONSTR1(GOUTPUT, OBS) DEA constraint

9

Optimization of the output and efficiency of a high power cascaded arc hydrogen plasma source  

SciTech Connect

The operation of a cascaded arc hydrogen plasma source was experimentally investigated to provide an empirical basis for the scaling of this source to higher plasma fluxes and efficiencies. The flux and efficiency were determined as a function of the input power, discharge channel diameter, and hydrogen gas flow rate. Measurements of the pressure in the arc channel show that the flow is well described by Poiseuille flow and that the effective heavy particle temperature is approximately 0.8 eV. Interpretation of the measured I-V data in terms of a one-parameter model shows that the plasma production is proportional to the input power, to the square root of the hydrogen flow rate, and is independent of the channel diameter. The observed scaling shows that the dominant power loss mechanism inside the arc channel is one that scales with the effective volume of the plasma in the discharge channel. Measurements on the plasma output with Thomson scattering confirm the linear dependence of the plasma production on the input power. Extrapolation of these results shows that (without a magnetic field) an improvement in the plasma production by a factor of 10 over where it was in van Rooij et al. [Appl. Phys. Lett. 90, 121501 (2007)] should be possible.

Vijvers, W. A. J.; Gils, C. A. J. van; Goedheer, W. J.; Meiden, H. J. van der; Veremiyenko, V. P.; Westerhout, J.; Lopes Cardozo, N. J.; Rooij, G. J. van [FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, Trilateral Euregio Cluster, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Schram, D. C. [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands)

2008-09-15T23:59:59.000Z

10

Variable Frequency AC Drives for Cooling Tower Energy Efficiency  

E-Print Network (OSTI)

and economics. Automatic fan speed control by sensing cold water temperature is the economic essence of the application of adjustable frequency power to A-C fan motors. 2.2 Cell Partitions In some multi-cell mechanical-draft cooling towers, the isolation... of individual cell air streams is ineffective due to one or more of the following: --Partitions are missing. --Partitions are incomplete. This condition results in temperature control problems. For example, if constant CWT is desired, and no means...

Corey, R. W.

1982-01-01T23:59:59.000Z

11

EIA Energy Efficiency-Table 3e. Gross Output by Selected Industries, 1998,  

Gasoline and Diesel Fuel Update (EIA)

e e Page Last Modified: May 2010 Table 3e. Gross Output1 by Selected Industries, 1998, 2002, and 2006 (Current Billion Dollars) MECS Survey Years NAICS Subsector and Industry 1998 2002 2006 311 Food Manufacturing 417 444 526 312 Beverage and Tobacco Product Manufacturing 114 128 144 313 Textile Mills 57 45 38 314 Textile Product Mills 31 30 32 315 Apparel Manufacturing 63 40 26 316 Leather and Allied Product Manufacturing 10 6 6 321 Wood Product Manufacturing 91 88 111 322 Paper Manufacturing 153 151 167 323 Printing and Related Support Activities 99 95 99 324 Petroleum and Coal Products Manufacturing 135 212 530 325 Chemical Manufacturing 407 444 639 326 Plastics and Rubber Products Manufacturing 162 169 208 327 Nonmetallic Mineral Product Manufacturing 91 94 126 331 Primary Metal Manufacturing 166 139 230 332 Fabricated Metal Product Manufacturing

12

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

A. Existing Transmission Capacity by High-Voltage Size, 2012 A. Existing Transmission Capacity by High-Voltage Size, 2012 Voltage Circuit Miles Type Operating (kV) FRCC MRO NPCC RFC SERC SPP TRE WECC Contiguous U.S. AC 100-199 -- -- -- -- -- -- -- -- -- AC 200-299 6,018 7,813 1,538 6,933 21,757 2,948 -- 38,410 85,416 AC 300-399 -- 7,362 5,850 13,429 3,650 5,303 9,529 10,913 56,036 AC 400-599 1,201 543 -- 2,618 8,876 94 -- 12,794 26,125 AC 600-799 -- -- 190 2,226 -- -- -- -- 2,416 AC Multi-Circuit Structure 200-299 1,198 686 36 2,008 4,156 9 -- -- 8,092 AC Multi-Circuit Structure 300-399 -- 372 274 3,706 313 153 2,747 -- 7,564 AC Multi-Circuit Structure 400-599 -- -- -- 90 857 -- -- -- 947 AC Multi-Circuit Structure 600-799 -- -- -- -- -- -- -- -- --

13

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

A. U.S. Transmission Circuit Sustained Automatic Outage Counts and Hours A. U.S. Transmission Circuit Sustained Automatic Outage Counts and Hours by High-Voltage Size and NERC Region, 2012 Sustained Automatic Outage Counts Voltage Region Type Operating (kV) FRCC MRO NPCC RFC SERC SPP TRE WECC Contiguous U.S. AC 200-299 142 49 14 141 242 49 -- 484 1,121 AC 300-399 -- 88 107 95 46 56 80 165 637 AC 400-599 9 3 -- 22 86 -- -- 125 245 AC 600+ -- -- 6 9 -- -- -- -- 15 AC Total 151 140 127 267 374 105 80 774 2,018 DC 100-199 -- -- -- -- -- -- -- -- -- DC 200-299 -- 18 -- -- -- -- -- 5 23 DC 300-399 -- -- -- -- -- -- -- -- -- DC 400-499 -- 5 -- -- -- -- -- -- 5 DC 500-599 -- -- -- 5 -- -- -- 17 22 DC 600+ -- -- -- -- -- -- -- -- --

14

Reliable, Efficient and Cost-Effective Electric Power Converter for Small Wind Turbines Based on AC-link Technology  

SciTech Connect

Grid-tied inverter power electronics have been an Achilles heel of the small wind industry, providing opportunity for new technologies to provide lower costs, greater efficiency, and improved reliability. The small wind turbine market is also moving towards the 50-100kW size range. The unique AC-link power conversion technology provides efficiency, reliability, and power quality advantages over existing technologies, and Princeton Power will adapt prototype designs used for industrial asynchronous motor control to a 50kW small wind turbine design.

Darren Hammell; Mark Holveck; DOE Project Officer - Keith Bennett

2006-08-01T23:59:59.000Z

15

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Proposed Transmission Capacity Additions by High-Voltage Size, 2013 - 2019 B. Proposed Transmission Capacity Additions by High-Voltage Size, 2013 - 2019 (Circuit Miles of Transmission) Voltage Circuit Miles Type Operating (kV) Year 2013 Year 2014 Year 2015 Year 2016 Year 2017 Year 2018 Year 2019 All Years AC 100-199 954 1,222 992 1,047 392 382 176 5,165 AC 200-299 1,003 792 1,398 319 539 427 118 4,596 AC 300-399 4,779 839 1,532 1,527 502 1,650 349 11,178 AC 400-599 399 708 669 643 660 1,151 334 4,564 AC 600+ -- -- 14 -- -- 69 -- 83 AC Total 7,134 3,562 4,606 3,536 2,092 3,679 978 25,586 DC 100-199 2 11 5 -- -- 7 -- 25 DC 200-299 -- -- -- -- -- -- -- -- DC 300-399 -- -- -- -- 333 -- -- 333 DC 400-599 -- -- 10 -- -- -- -- 10 DC 600+ -- -- -- -- -- -- -- --

16

Dimmable AC LED Driver With Efficiency Improved Based on Switched LED Module  

Science Journals Connector (OSTI)

In this paper, one AC light-emitting diode (LED) driver with high power factor (PF) and low total harmonic distortion (THD) is adopted, which is added with the proposed...

Hwu, K I; Tu, W C; Fang, Y T

2014-01-01T23:59:59.000Z

17

Output Analysis  

Science Journals Connector (OSTI)

Every discrete-event simulation experiment with random input generates random sample paths as output. Each path usually consists of a sequence of dependent observations that serve as the raw material for estim...

George S. Fishman

2001-01-01T23:59:59.000Z

18

CD54AC04, CD74AC04 HEX INVERTERS  

E-Print Network (OSTI)

°C to 125°C SOIC M Tube CD74AC04M AC04M­55°C to 125°C SOIC ­ M Tape and reel CD74AC04M96 AC04M CDIP-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

19

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. U.S. Transformer Sustained Automatic Outage Counts and Hours by Cause Code and by NERC Region, 2012 B. U.S. Transformer Sustained Automatic Outage Counts and Hours by Cause Code and by NERC Region, 2012 Transformer Outage Counts Sustained Outage Causes FRCC MRO NPCC RFC SERC SPP TRE WECC Contiguous U.S. Weather, excluding lightning -- -- -- -- 1.00 -- -- -- 1.00 Lightning -- -- -- -- -- -- -- -- -- Environmental -- -- -- -- -- -- -- -- -- Contamination 1.00 -- -- -- -- -- -- -- 1.00 Foreign Interference -- -- -- -- -- -- -- -- -- Fire -- -- -- -- -- -- -- -- -- Vandalism, Terrorism, or Malicious Acts -- -- -- -- -- -- -- -- -- Failed AC Substation Equipment 3.00 1.00 -- 1.00 5.00 -- -- 4.00 14.00 Failed AC/DC Terminal Equipment -- -- -- -- -- -- -- -- -- Failed Protection System Equipment -- 1.00 -- -- 3.00 -- -- -- 4.00

20

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

A. U.S. Transmission Circuit Sustained Automatic Outage Counts and Hours by Cause Code and by NERC Region, 2012 A. U.S. Transmission Circuit Sustained Automatic Outage Counts and Hours by Cause Code and by NERC Region, 2012 AC & DC Circuit Outage Counts Sustained Outage Causes FRCC MRO NPCC RFC SERC SPP TRE WECC Contiguous U.S. Weather, excluding lightning 6.00 27.00 3.00 30.00 63.00 12.00 -- 69.00 210.00 Lightning 5.00 10.00 8.00 5.00 31.00 16.00 13.00 57.00 145.00 Environmental -- 1.00 1.00 5.00 -- 1.00 -- -- 8.00 Contamination 14.00 -- -- -- 22.00 3.00 6.00 7.00 52.00 Foreign Interference 34.00 3.00 -- 4.00 13.00 1.00 2.00 14.00 71.00 Fire -- 2.00 -- 1.00 6.00 3.00 1.00 85.00 98.00 Vandalism, Terrorism, or Malicious Acts -- -- -- -- 2.00 -- -- 1.00 3.00 Failed AC Substation Equipment 18.00 16.00 35.00 63.00 57.00 16.00 15.00 65.00 285.00

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Contract DE-AC36-83CH10093 Energy Efficiency 1  

E-Print Network (OSTI)

Energy efficiency is a measure of how much value we get from energy that we consume; any increase in efficiency means a decrease in use and consequently savings in cost, pollution, carbon emissions, and foreign dependence. Estimates of past and potential future energy and cost savings resulting from increases in energy efficiency vary widely, but all suggest that it is one of our most substantial "new energy " resources.

unknown authors

22

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Landfill Gas: Consumption for Useful Thermal Output, B. Landfill Gas: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Million Cubic Feet) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 993 0 116 0 876 2004 2,174 0 735 10 1,429 2005 1,923 0 965 435 522 2006 2,051 0 525 1,094 433 2007 1,988 0 386 1,102 501 2008 1,025 0 454 433 138 2009 793 0 545 176 72 2010 1,623 0 1,195 370 58 2011 3,195 0 2,753 351 91 2012 3,189 0 2,788 340 61 2010 January 118 0 83 30 5 February 110 0 79 27 5 March 132 0 94 32 6 April 131 0 93 33 6 May 132 0 92 34 6 June 139 0 104 30 5 July 140 0 102 33 5 August 132 0 95 32 5 September 148 0 113 30 5

23

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Petroleum Coke: Consumption for Useful Thermal Output, B. Petroleum Coke: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Thousand Tons) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 517 0 111 6 399 2003 763 0 80 9 675 2004 1,043 0 237 8 798 2005 783 0 206 8 568 2006 1,259 0 195 9 1,055 2007 1,262 0 162 11 1,090 2008 897 0 119 9 769 2009 1,007 0 126 8 873 2010 1,059 0 98 11 950 2011 1,080 0 112 6 962 2012 1,346 0 113 11 1,222 2010 January 92 0 10 1 81 February 93 0 10 1 82 March 84 0 12 1 71 April 76 0 9 1 66 May 84 0 10 0 75 June 93 0 8 0 86 July 89 0 8 0 80 August 87 0 2 1 84 September 82 0 2 1 79

24

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

F. Petroleum Coke: Consumption for Electricity Generation and Useful Thermal Output, F. Petroleum Coke: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 193,120 57,296 105,416 227 30,182 2003 197,827 69,695 92,384 309 35,440 2004 245,389 116,086 90,747 259 38,297 2005 256,441 115,727 111,098 260 29,356 2006 246,687 102,117 98,314 269 45,987 2007 208,198 77,941 81,845 348 48,064 2008 180,034 64,843 79,856 280 35,055 2009 166,449 77,919 52,428 245 35,856 2010 173,078 94,331 41,090 340 37,317 2011 176,349 99,257 40,167 173 36,752 2012 144,266 60,862 24,925 353 58,126 2010 January 14,949 7,995 3,716 38 3,199

25

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

C. Coal: Consumption for Electricity Generation and Useful Thermal Output, C. Coal: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Thousand Tons) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 1,005,144 767,803 209,703 1,405 26,232 2003 1,031,778 757,384 247,732 1,816 24,846 2004 1,044,798 772,224 244,044 1,917 26,613 2005 1,065,281 761,349 276,135 1,922 25,875 2006 1,053,783 753,390 273,246 1,886 25,262 2007 1,069,606 764,765 280,377 1,927 22,537 2008 1,064,503 760,326 280,254 2,021 21,902 2009 955,190 695,615 238,012 1,798 19,766 2010 1,001,411 721,431 253,621 1,720 24,638 2011 956,470 689,316 243,168 1,668 22,319 2012 845,066 615,467 208,085 1,450 20,065

26

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

E. Landfill Gas: Consumption for Useful Thermal Output, E. Landfill Gas: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 500 0 61 0 439 2004 1,158 0 415 5 738 2005 994 0 519 212 263 2006 1,034 0 267 549 218 2007 985 0 226 532 228 2008 552 0 271 211 70 2009 440 0 313 91 37 2010 847 0 643 174 30 2011 1,635 0 1,422 165 48 2012 1,630 0 1,441 156 32 2010 January 61 0 44 14 3 February 58 0 42 13 3 March 67 0 49 15 3 April 67 0 49 15 3 May 68 0 49 16 3 June 73 0 56 14 3 July 73 0 55 16 2 August 69 0 52 15 3 September 79 0 62 14 3 October 75 0 59 14 2

27

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Coal: Consumption for Useful Thermal Output, B. Coal: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Thousand Tons) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 17,561 0 2,255 929 14,377 2003 17,720 0 2,080 1,234 14,406 2004 24,275 0 3,809 1,540 18,926 2005 23,833 0 3,918 1,544 18,371 2006 23,227 0 3,834 1,539 17,854 2007 22,810 0 3,795 1,566 17,449 2008 22,168 0 3,689 1,652 16,827 2009 20,507 0 3,935 1,481 15,091 2010 21,727 0 3,808 1,406 16,513 2011 21,532 0 3,628 1,321 16,584 2012 19,333 0 2,790 1,143 15,400 2010 January 1,972 0 371 160 1,440 February 1,820 0 347 139 1,334 March 1,839 0 338 123 1,378 April 2,142 0 284 95 1,764

28

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

E. Petroleum Liquids: Consumption for Useful Thermal Output, E. Petroleum Liquids: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 76,737 0 1,669 3,276 71,788 2003 85,488 0 6,963 3,176 75,349 2004 124,809 0 8,592 7,219 108,997 2005 125,689 0 8,134 6,145 111,410 2006 87,137 0 6,740 3,481 76,916 2007 82,768 0 7,602 2,754 72,412 2008 45,481 0 7,644 2,786 35,051 2009 48,912 0 7,557 1,802 39,552 2010 29,243 0 6,402 1,297 21,545 2011 22,799 0 5,927 1,039 15,833 2012 18,233 0 5,871 746 11,616 2010 January 3,648 0 614 190 2,843 February 3,027 0 422 157 2,447 March 2,015 0 272 43 1,699

29

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

C. Petroleum Liquids: Consumption for Electricity Generation and Useful Thermal Output, C. Petroleum Liquids: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Thousand Barrels) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 146,643 88,595 39,320 1,210 17,517 2003 189,260 105,319 62,617 1,394 19,929 2004 185,761 103,793 57,843 1,963 22,162 2005 185,631 98,223 63,546 1,584 22,278 2006 87,898 53,529 18,332 886 15,150 2007 95,895 56,910 24,097 691 14,198 2008 61,379 38,995 14,463 621 7,300 2009 51,690 31,847 11,181 477 8,185 2010 44,968 30,806 9,364 376 4,422 2011 31,152 20,844 6,637 301 3,370 2012 25,702 17,521 5,102 394 2,685 2010 January 6,193 4,381 1,188 48 576

30

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

E. Wood / Wood Waste Biomass: Consumption for Useful Thermal Output, E. Wood / Wood Waste Biomass: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 682,060 0 9,585 727 671,747 2003 746,375 0 10,893 762 734,720 2004 1,016,124 0 14,968 1,493 999,663 2005 997,331 0 19,193 1,028 977,111 2006 1,049,161 0 18,814 1,045 1,029,303 2007 982,486 0 21,435 1,756 959,296 2008 923,889 0 18,075 1,123 904,690 2009 816,285 0 19,587 1,135 795,563 2010 876,041 0 18,357 1,064 856,620 2011 893,314 0 16,577 1,022 875,716 2012 883,158 0 19,251 949 862,958 2010 January 73,418 0 1,677 91 71,651 February 67,994 0 1,689 81 66,224

31

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

F. Landfill Gas: Consumption for Electricity Generation and Useful Thermal Output, F. Landfill Gas: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 66,270 3,930 59,149 1,753 1,438 2004 70,489 5,373 60,929 2,098 2,089 2005 68,897 5,650 59,144 2,571 1,532 2006 77,004 8,287 64,217 3,937 563 2007 80,697 8,620 68,657 2,875 544 2008 94,768 10,242 81,300 2,879 346 2009 100,261 9,748 87,086 3,089 337 2010 106,681 10,029 93,405 3,011 236 2011 114,173 11,146 91,279 11,497 251 2012 125,927 12,721 101,379 10,512 1,315 2010 January 8,502 853 7,379 251 19 February 7,882 830 6,823 209 20

32

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

E. Other Waste Biomass: Consumption for Useful Thermal Output, E. Other Waste Biomass: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 29,854 0 10,655 757 18,442 2004 30,228 0 12,055 2,627 15,547 2005 38,010 0 10,275 2,086 25,649 2006 36,966 0 8,561 2,318 26,087 2007 41,757 0 10,294 2,643 28,820 2008 41,851 0 9,674 1,542 30,635 2009 41,810 0 10,355 1,638 29,817 2010 47,153 0 8,436 1,648 37,070 2011 43,483 0 6,460 1,566 35,458 2012 46,863 0 6,914 1,796 38,153 2010 January 4,885 0 1,088 137 3,661 February 4,105 0 943 137 3,025 March 4,398 0 845 136 3,417 April 4,224 0 399 138 3,688

33

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

E. Petroleum Coke: Consumption for Useful Thermal Output, E. Petroleum Coke: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 14,395 0 3,192 179 11,024 2003 21,170 0 2,282 244 18,644 2004 29,342 0 6,768 226 22,347 2005 22,224 0 5,935 228 16,061 2006 38,169 0 5,672 236 32,262 2007 38,033 0 4,710 303 33,019 2008 27,100 0 3,441 243 23,416 2009 29,974 0 3,652 213 26,109 2010 31,303 0 2,855 296 28,152 2011 31,943 0 3,244 153 28,546 2012 38,777 0 3,281 315 35,181 2010 January 2,683 0 285 33 2,365 February 2,770 0 302 29 2,439 March 2,424 0 338 36 2,050 April 2,257 0 255 22 1,980

34

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

F. Other Waste Biomass: Consumption for Electricity Generation and Useful Thermal Output, F. Other Waste Biomass: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 64,629 2,456 26,514 5,323 30,337 2004 49,443 2,014 21,294 6,935 19,201 2005 55,862 2,485 17,640 6,763 28,974 2006 54,693 2,611 16,348 6,755 28,980 2007 60,840 2,992 19,155 6,692 32,001 2008 66,139 3,409 22,419 5,227 35,085 2009 66,658 3,679 23,586 5,398 33,994 2010 77,150 3,668 22,884 5,438 45,159 2011 74,255 4,488 22,574 5,382 41,810 2012 77,205 4,191 22,654 5,812 44,548 2010 January 7,109 189 2,166 458 4,295 February 6,441 275 2,151 429 3,586

35

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

F. Natural Gas: Consumption for Electricity Generation and Useful Thermal Output, F. Natural Gas: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 7,135,572 2,307,358 3,481,961 75,985 1,270,268 2003 6,498,549 1,809,003 3,450,177 60,662 1,178,707 2004 6,912,661 1,857,247 3,749,945 73,744 1,231,725 2005 7,220,520 2,198,098 3,837,717 69,682 1,115,023 2006 7,612,500 2,546,169 3,847,644 69,401 1,149,286 2007 8,181,986 2,808,500 4,219,827 71,560 1,082,099 2008 7,900,986 2,803,283 4,046,069 67,571 984,062 2009 8,138,385 2,981,285 4,062,633 77,077 1,017,390 2010 8,694,186 3,359,035 4,191,241 87,357 1,056,553

36

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Biogenic Municipal Solid Waste: Consumption for Useful Thermal Output, B. Biogenic Municipal Solid Waste: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Thousand Tons) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 1,358 0 311 865 182 2004 2,743 0 651 1,628 464 2005 2,719 0 623 1,536 560 2006 2,840 0 725 1,595 520 2007 2,219 0 768 1,136 315 2008 2,328 0 806 1,514 8 2009 2,426 0 823 1,466 137 2010 2,287 0 819 1,316 152 2011 2,044 0 742 1,148 154 2012 1,986 0 522 1,273 190 2010 January 191 0 69 107 14 February 178 0 61 106 11 March 204 0 66 126 12 April 207 0 67 127 13 May 249 0 67 167 15 June 204 0 69 120 14 July 194 0 68 115 11

37

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

C. Landfill Gas: Consumption for Electricity Generation and Useful Thermal Output, C. Landfill Gas: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Million Cubic Feet) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 137,414 9,168 122,100 3,280 2,865 2004 146,018 11,250 126,584 4,091 4,093 2005 143,822 11,490 124,030 5,232 3,070 2006 162,084 16,617 136,632 7,738 1,096 2007 168,762 17,442 144,490 5,699 1,131 2008 196,802 20,465 170,001 5,668 668 2009 207,585 19,583 181,234 6,106 661 2010 219,954 19,975 193,623 5,905 451 2011 235,990 22,086 183,609 29,820 474 2012 259,564 25,193 204,753 27,012 2,606 2010 January 17,649 1,715 15,406 491 37 February 16,300 1,653 14,198 410 38

38

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

C. Petroleum Coke: Consumption for Electricity Generation and Useful Thermal Output, C. Petroleum Coke: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Thousand Tons) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 7,353 2,125 3,691 8 1,529 2003 7,067 2,554 3,245 11 1,257 2004 8,721 4,150 3,223 9 1,339 2005 9,113 4,130 3,953 9 1,020 2006 8,622 3,619 3,482 10 1,511 2007 7,299 2,808 2,877 12 1,602 2008 6,314 2,296 2,823 10 1,184 2009 5,828 2,761 1,850 9 1,209 2010 6,053 3,325 1,452 12 1,264 2011 6,092 3,449 1,388 6 1,248 2012 5,021 2,105 869 13 2,034 2010 January 525 283 130 1 110 February 497 258 131 1 106 March 522 308 119 1 94

39

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

E. Biogenic Municipal Solid Waste: Consumption for Useful Thermal Output, E. Biogenic Municipal Solid Waste: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 13,694 0 3,118 8,858 1,718 2004 19,991 0 4,746 12,295 2,950 2005 20,296 0 4,551 11,991 3,754 2006 21,729 0 5,347 12,654 3,728 2007 16,174 0 5,683 8,350 2,141 2008 18,272 0 6,039 12,174 59 2009 18,785 0 6,229 11,535 1,021 2010 17,502 0 6,031 10,333 1,138 2011 16,766 0 5,807 9,731 1,227 2012 16,310 0 4,180 10,615 1,515 2010 January 1,476 0 518 851 107 February 1,365 0 444 835 86 March 1,572 0 486 992 93 April 1,598 0 495 1,003 100

40

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Petroleum Liquids: Consumption for Useful Thermal Output, B. Petroleum Liquids: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Thousand Barrels) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 12,228 0 286 384 11,558 2003 14,124 0 1,197 512 12,414 2004 20,654 0 1,501 1,203 17,951 2005 20,494 0 1,392 1,004 18,097 2006 14,077 0 1,153 559 12,365 2007 13,462 0 1,303 441 11,718 2008 7,533 0 1,311 461 5,762 2009 8,128 0 1,301 293 6,534 2010 4,866 0 1,086 212 3,567 2011 3,826 0 1,004 168 2,654 2012 3,097 0 992 122 1,984 2010 January 606 0 105 31 470 February 504 0 78 26 401 March 335 0 46 7 281 April 355 0 86 9 260 May 340 0 93 14 232

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

E. Natural Gas: Consumption for Useful Thermal Output, E. Natural Gas: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 885,987 0 267,675 45,359 572,953 2003 762,779 0 250,120 21,238 491,421 2004 1,085,191 0 398,476 40,122 646,593 2005 1,008,404 0 392,842 35,037 580,525 2006 968,574 0 339,047 33,928 595,599 2007 894,272 0 347,181 36,689 510,402 2008 813,794 0 333,197 33,434 447,163 2009 836,863 0 312,553 42,032 482,279 2010 841,521 0 308,246 47,001 486,274 2011 861,006 0 315,411 40,976 504,619 2012 909,087 0 330,354 48,944 529,788 2010 January 74,586 0 27,368 4,148 43,070 February 65,539 0 24,180 3,786 37,573

42

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2. Useful Thermal Output by Energy Source: Electric Power Sector Combined Heat and Power, 2002 - 2012 2. Useful Thermal Output by Energy Source: Electric Power Sector Combined Heat and Power, 2002 - 2012 (Billion Btus) Period Coal Petroleum Liquids Petroleum Coke Natural Gas Other Gas Renewable Sources Other Total Annual Totals 2002 40,020 1,319 2,550 214,137 5,961 12,550 4,732 281,269 2003 38,249 5,551 1,828 200,077 9,282 19,785 3,296 278,068 2004 39,014 5,731 2,486 239,416 18,200 17,347 3,822 326,017 2005 39,652 5,571 2,238 239,324 36,694 18,240 3,884 345,605 2006 38,133 4,812 2,253 207,095 22,567 17,284 4,435 296,579 2007 38,260 5,294 1,862 212,705 20,473 19,166 4,459 302,219 2008 37,220 5,479 1,353 204,167 22,109 17,052 4,854 292,234 2009 38,015 5,341 1,445 190,875 19,830 17,625 5,055 278,187

43

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

3. Useful Thermal Output by Energy Source: Commerical Sector Combined Heat and Power, 2002 - 2012 3. Useful Thermal Output by Energy Source: Commerical Sector Combined Heat and Power, 2002 - 2012 (Billion Btus) Period Coal Petroleum Liquids Petroleum Coke Natural Gas Other Gas Renewable Sources Other Total Annual Totals 2002 18,477 2,600 143 36,265 0 6,902 4,801 69,188 2003 22,780 2,520 196 16,955 0 8,296 6,142 56,889 2004 22,450 4,118 165 21,851 0 8,936 6,350 63,871 2005 22,601 3,518 166 20,227 0 8,647 5,921 61,081 2006 22,186 2,092 172 19,370 0.22 9,359 6,242 59,422 2007 22,595 1,640 221 20,040 0 6,651 3,983 55,131 2008 22,991 1,822 177 20,183 0 8,863 6,054 60,091 2009 20,057 1,095 155 25,902 0 8,450 5,761 61,420 2010 19,216 845 216 29,791 13 7,917 5,333 63,330 2011 17,234 687 111 24,848 14 7,433 5,988 56,314

44

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

F. Petroleum Liquids: Consumption for Electricity Generation and Useful Thermal Output, F. Petroleum Liquids: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 912,218 553,390 243,561 7,229 108,031 2003 1,174,795 658,868 387,341 8,534 120,051 2004 1,156,763 651,712 358,685 11,763 134,603 2005 1,160,733 618,811 395,489 9,614 136,820 2006 546,529 335,130 112,052 5,444 93,903 2007 595,191 355,999 147,579 4,259 87,354 2008 377,848 242,379 87,460 3,743 44,266 2009 315,420 196,346 66,834 2,903 49,336 2010 273,357 188,987 55,444 2,267 26,660 2011 186,753 125,755 39,093 1,840 20,066 2012 153,189 105,179 29,952 2,364 15,695

45

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Natural Gas: Consumption for Useful Thermal Output, B. Natural Gas: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Million Cubic Feet) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 860,024 0 263,619 41,435 554,970 2003 721,267 0 225,967 19,973 475,327 2004 1,052,100 0 388,424 39,233 624,443 2005 984,340 0 384,365 34,172 565,803 2006 942,817 0 330,878 33,112 578,828 2007 872,579 0 339,796 35,987 496,796 2008 793,537 0 326,048 32,813 434,676 2009 816,787 0 305,542 41,275 469,970 2010 821,775 0 301,769 46,324 473,683 2011 839,681 0 308,669 39,856 491,155 2012 886,103 0 322,607 47,883 515,613 2010 January 72,867 0 26,791 4,086 41,990

46

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

E. Coal: Consumption for Useful Thermal Output, E. Coal: Consumption for Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 421,084 0 50,041 23,099 347,944 2003 416,700 0 47,817 28,479 340,405 2004 564,497 0 87,981 34,538 441,978 2005 548,666 0 88,364 34,616 425,685 2006 532,561 0 84,335 34,086 414,140 2007 521,717 0 83,838 34,690 403,189 2008 503,096 0 81,416 36,163 385,517 2009 462,674 0 90,867 32,651 339,156 2010 490,931 0 90,184 30,725 370,022 2011 479,822 0 84,855 28,056 366,911 2012 420,923 0 58,275 23,673 338,975 2010 January 44,514 0 8,627 3,445 32,442 February 40,887 0 8,041 3,024 29,823

47

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

F. Wood / Wood Waste Biomass: Consumption for Electricity Generation and Useful Thermal Output, F. Wood / Wood Waste Biomass: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 1,287,114 10,659 139,532 1,196 1,135,727 2003 1,265,669 16,545 150,745 1,199 1,097,180 2004 1,360,258 19,973 145,216 1,661 1,193,408 2005 1,352,582 27,373 157,600 1,235 1,166,373 2006 1,399,235 27,455 154,360 1,314 1,216,106 2007 1,335,511 31,568 154,388 2,040 1,147,516 2008 1,262,675 29,150 148,198 1,410 1,083,917 2009 1,136,729 29,565 150,481 1,408 955,276 2010 1,225,571 40,167 155,429 1,338 1,028,637 2011 1,240,937 35,474 146,684 1,504 1,057,275

48

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

1. Useful Thermal Output by Energy Source: Total Combined Heat and Power (All Sectors), 2002 - 2012 1. Useful Thermal Output by Energy Source: Total Combined Heat and Power (All Sectors), 2002 - 2012 (Billion Btus) Period Coal Petroleum Liquids Petroleum Coke Natural Gas Other Gas Renewable Sources Other Total Annual Totals 2002 336,848 61,313 11,513 708,738 117,513 571,509 48,263 1,855,697 2003 333,361 68,329 16,934 610,122 110,263 632,366 54,960 1,826,335 2004 351,871 80,824 16,659 654,242 126,157 667,341 45,456 1,942,550 2005 341,806 79,362 13,021 624,008 138,469 664,691 41,400 1,902,757 2006 332,548 54,224 24,009 603,288 126,049 689,549 49,308 1,878,973 2007 326,803 50,882 25,373 554,394 116,313 651,230 46,822 1,771,816 2008 315,244 29,554 18,263 509,330 110,680 610,131 23,729 1,616,931 2009 281,557 32,591 20,308 513,002 99,556 546,974 33,287 1,527,276

49

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

F. Biogenic Municipal Solid Waste: Consumption for Electricity Generation and F. Biogenic Municipal Solid Waste: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 161,803 5,766 132,065 21,953 2,020 2004 161,567 3,705 129,562 25,204 3,096 2005 164,635 4,724 131,080 24,914 3,918 2006 168,716 4,078 135,127 25,618 3,893 2007 162,482 4,557 133,509 21,393 3,022 2008 166,723 4,476 136,080 26,108 59 2009 165,755 3,989 132,877 27,868 1,021 2010 162,436 3,322 130,467 27,509 1,138 2011 152,007 3,433 121,648 25,664 1,262 2012 152,045 3,910 117,598 28,923 1,614 2010 January 13,015 244 10,405 2,260 107

50

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

1. Emissions from Energy Consumption at 1. Emissions from Energy Consumption at Conventional Power Plants and Combined-Heat-and-Power Plants 2002 through 2012 (Thousand Metric Tons) Year Carbon Dioxide (CO2) Sulfur Dioxide (SO2) Nitrogen Oxides (NOx) 2002 2,423,963 10,881 5,194 2003 2,445,094 10,646 4,532 2004 2,486,982 10,309 4,143 2005 2,543,838 10,340 3,961 2006 2,488,918 9,524 3,799 2007 2,547,032 9,042 3,650 2008 2,484,012 7,830 3,330 2009 2,269,508 5,970 2,395 2010 2,388,596 5,400 2,491 2011 2,287,071 4,845 2,406 2012 2,156,875 3,704 2,148 Notes: The emissions data presented include total emissions from both electricity generation and the production of useful thermal output. See Appendix A, Technical Notes, for a description of the sources and methodology used to develop the emissions estimates.

51

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

C. Biogenic Municipal Solid Waste: Consumption for Electricity Generation and C. Biogenic Municipal Solid Waste: Consumption for Electricity Generation and Useful Thermal Output, by Sector, 2002 - 2012 (Thousand Tons) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 22,554 695 18,611 2,952 296 2004 22,330 444 17,959 3,439 488 2005 22,089 560 17,655 3,289 584 2006 22,469 500 18,068 3,356 545 2007 21,796 553 17,885 2,921 437 2008 22,134 509 18,294 3,323 8 2009 22,095 465 17,872 3,622 137 2010 21,725 402 17,621 3,549 152 2011 19,016 388 15,367 3,103 158 2012 18,954 418 14,757 3,577 203 2010 January 1,737 30 1,402 291 14 February 1,562 25 1,276 250 11 March 1,854 36 1,500 306 12

52

CD54AC08, CD74AC08 QUADRUPLE 2-INPUT POSITIVE-AND GATES  

E-Print Network (OSTI)

SOIC M Tube CD74AC08M AC08M­55°C to 125°C SOIC ­ M Tape and reel CD74AC08M96 AC08M CDIP ­ F Tube CD54AC-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

53

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2. Demand-Side Management Program Annual Effects by Program 2. Demand-Side Management Program Annual Effects by Program Category, by Sector, 2002 through 2012 Year Residential Commercial Industrial Transportation Total Energy Efficiency - Energy Savings (Thousand MWh) 2002 15,284 24,803 10,242 -- 50,328 2003 12,914 24,758 10,031 551 48,254 2004 17,185 24,290 11,137 50 52,663 2005 18,894 28,073 11,986 47 59,000 2006 21,150 28,720 13,155 50 63,076 2007 22,772 30,359 14,038 108 67,278 2008 25,396 34,634 14,766 75 74,871 2009 27,395 34,831 14,610 76 76,912 2010 32,150 37,416 17,259 89 86,914 2011 46,790 50,732 23,061 76 120,659 2012 54,516 58,894 25,023 92 138,525 Energy Efficiency - Actual Peak Load Reduction (MW) 2002 5,300 5,389 2,768 -- 13,457 2003 5,909 4,911 2,671 94 13,585

54

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

5. Demand-Side Management Program Direct and Indirect Costs, 5. Demand-Side Management Program Direct and Indirect Costs, 2002 through 2012 (Thousand Dollars) Year Energy Efficiency Load Management Direct Cost Indirect Cost Total Cost 2002 1,032,911 410,323 1,443,234 206,169 1,649,403 2003 807,403 352,137 1,159,540 137,670 1,340,686 2004 910,816 510,281 1,421,097 132,295 1,560,578 2005 1,180,576 622,287 1,802,863 127,925 1,939,115 2006 1,270,602 663,980 1,934,582 128,886 2,072,962 2007 1,677,969 700,362 2,378,331 160,326 2,604,711 2008 2,137,452 836,359 2,973,811 181,843 3,186,742 2009 2,221,480 944,261 3,165,741 394,193 3,607,076 2010 2,906,906 1,048,356 3,955,262 275,158 4,230,420 2011 4,002,672 1,213,102 5,215,774 328,622 5,544,396 2012 4,397,635 1,270,391 5,668,026 332,440 6,000,466

55

CD54AC02, CD74AC02 QUADRUPLE 2-INPUT POSITIVE-NOR GATES  

E-Print Network (OSTI)

to 125°C SOIC ­ M Tape and reel CD74AC02M96 AC02M CDIP ­ F Tube CD54AC02F3A CD54AC02F3A Package drawings-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

56

CD54AC32, CD74AC32 QUADRUPLE 2-INPUT POSITIVE-OR GATES  

E-Print Network (OSTI)

Tape and reel CD74AC32M96 AC32M CDIP ­ F Tube CD54AC32F3A CD54AC32F3A Package drawings, standard-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

57

Distinguishing Weak and Strong Disposability among Undesireable Outputs in DEA: The Example of the Environmental Efficiency of Chinese Coal-Fired Power Plants  

E-Print Network (OSTI)

in terajoules (TJ). 4.2 Undesirable Outputs Undesirable variable refers to emissions from the electricity generation process. Coal is a combustible mineral composed primarily of carbon and hydrocarbon, along with other assorted elements including nitrogen... of the sample power plants is 211.71GW. The total annual generation is 1117.59 TWh. Data, such as installed capacity, annual fuel consumption (coal and oil), number of employees, annual electricity generation, heat rates, and quality of fuel, were collected...

Yu, Hongliang; Pollitt, Michael G.

58

Energy Input Output Calculator | Open Energy Information  

Open Energy Info (EERE)

Input Output Calculator Input Output Calculator Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Energy Input-Output Calculator Agency/Company /Organization: Department of Energy Sector: Energy Focus Area: Energy Efficiency Resource Type: Online calculator User Interface: Website Website: www2.eere.energy.gov/analysis/iocalc/Default.aspx Web Application Link: www2.eere.energy.gov/analysis/iocalc/Default.aspx OpenEI Keyword(s): Energy Efficiency and Renewable Energy (EERE) Tools Language: English References: EERE Energy Input-Output Calculator[1] The Energy Input-Output Calculator (IO Calculator) allows users to estimate the economic development impacts from investments in alternate electricity generating technologies. About the Calculator The Energy Input-Output Calculator (IO Calculator) allows users to estimate

59

Installation considerations for IGBT AC drives  

SciTech Connect

In the last four years, Adjustable Speed ac Drive (ASD) manufacturers have migrated from Bipolar Junction Transistor (BJT) semiconductors to Insulated Gate Bipolar Transistors (IGBTs) as the preferred Output switching device. The advantage of IGBTs over BJTs is that device rise and fall time switching capability is 5 - 10 times faster, resulting in lower device switching loss and a more efficient drive. However, for a similar motor cable length as the BJT drive, the faster output voltage risetime of the IGBT drive may increase the dielectric voltage stress on the motor and cable due to a phenomenon called reflected wave. Faster output dv/dt transitions of IGBT drives also increase the possibility for phenomenon such as increased Common Mode (CM) electrical noise, Electromagnetic Interference (EMI) problems and increased capacitive cable charging current problems. Also, recent experience suggests any Pulse Width Modulated (PWM) drive with a steep fronted output voltage wave form may increase motor shaft voltage and lead to a bearing current phenomenon known as fluting. This paper provides a basic understanding of these issues, as well as solutions, to insure a successful drive system installation.

Skibinski, G.L.

1997-06-01T23:59:59.000Z

60

EA-1926: Energy Efficiency Design Standards for New Federal Low-Rise Residential Buildings (RIN# 1904-AC61)  

Energy.gov (U.S. Department of Energy (DOE))

This EA will evaluate the potential environmental impacts of implementing the provisions in the Energy Conservation and Production Act (ECPA) that require DOE to update the baseline Federal energy efficiency performance standards for the construction of new Federal buildings, including low-rise residential buildings.

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.  

E-Print Network (OSTI)

, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL with high-number wire arrays The conversion of Sandia's Particle Beam Fusion Accelerator II (PBFA II output ~1.6 MJ ~200 TW Marx 11.4 MJ water vacuum Electrical to x-ray energy Conversion efficiency ~ 15

62

Boosting America's Hydropower Output | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Boosting America's Hydropower Output Boosting America's Hydropower Output Boosting America's Hydropower Output October 9, 2012 - 2:10pm Addthis The Boulder Canyon Hydroelectric Facility's new, highly-efficient turbine. | Photo courtesy of the city of Boulder, Colorado. The Boulder Canyon Hydroelectric Facility's new, highly-efficient turbine. | Photo courtesy of the city of Boulder, Colorado. City of Boulder employees celebrate the completion of the Boulder Canyon Hydroelectric Modernization project. | Photo courtesy of the city of Boulder, Colorado. City of Boulder employees celebrate the completion of the Boulder Canyon Hydroelectric Modernization project. | Photo courtesy of the city of Boulder, Colorado. The Boulder Canyon Hydroelectric Facility's new, highly-efficient turbine. | Photo courtesy of the city of Boulder, Colorado.

63

MODELING MULTI-OUTPUT FILTERING EFFECTS IN PCMOS Anshul Singh*  

E-Print Network (OSTI)

MODELING MULTI-OUTPUT FILTERING EFFECTS IN PCMOS Anshul Singh* , Arindam Basu , Keck-Voon Ling* and Vincent J. Mooney III*$§ Email: anshul.singh@research.iiit.ac.in, {arindam.basu, ekvling}@ntu, Nanyang Technological University (NTU), Singapore * NTU-Rice Institute of Sustainable and Applied

Mooney, Vincent

64

Analysis and design of a direct AC to AC matrix converter topology  

E-Print Network (OSTI)

However, the NCC has the following disadvantages, 1. very limited(fow) output frequency range 2. subharmonics are generated at input and output side 3. poor input power factor These disadvantages can be overcome by employing forced commutated bidirec... diode sre connected anti-series. The main objectives of this thesis are summarized as follows, 1. Study and analysis of direct ac to ac matrix power converters. 2. Preseiitation of a new PWM control strategy to selectively eliminate unwanted lower...

Choi, Sewan

2012-06-07T23:59:59.000Z

65

AC Transit  

Energy.gov (U.S. Department of Energy (DOE))

AC Transit (or the Alameda-Contra Costa Transit District) is based in Oakland, California, and provides transportation services to the East Bay of San Francisco. The 360-square-mile service area includes 13 cities and adjacent unincorporated areas in Alameda and Contra Costa counties. AC Transit's approximately 638 vehicles serve more than 65 million annual passengers.

66

Enhanced performance CCD output amplifier  

DOE Patents (OSTI)

A low-noise FET amplifier is connected to amplify output charge from a che coupled device (CCD). The FET has its gate connected to the CCD in common source configuration for receiving the output charge signal from the CCD and output an intermediate signal at a drain of the FET. An intermediate amplifier is connected to the drain of the FET for receiving the intermediate signal and outputting a low-noise signal functionally related to the output charge signal from the CCD. The amplifier is preferably connected as a virtual ground to the FET drain. The inherent shunt capacitance of the FET is selected to be at least equal to the sum of the remaining capacitances.

Dunham, Mark E. (Los Alamos, NM); Morley, David W. (Santa Fe, NM)

1996-01-01T23:59:59.000Z

67

EXPERIMENTAL STUDY OF ELECTROLYTE DEPENDENCE OF AC ELECTROOSMOTIC PUMPS  

E-Print Network (OSTI)

EXPERIMENTAL STUDY OF ELECTROLYTE DEPENDENCE OF AC ELECTROOSMOTIC PUMPS Kapil Subramanian1 , John Abstract: Recent studies indicate increased efficiency of microfluidic ac electro-osmotic pumps of ac electroosmosis in microchannels on solution chemistry for the new fast aceo stepped pumps

Bazant, Martin Z.

68

AN "AC INDUCTOR" BASED GRID CONNECTED INVERTER  

E-Print Network (OSTI)

AN "AC INDUCTOR" BASED GRID CONNECTED INVERTER Ilya Zeltser, Student Member, IEEE and Sam Ben proposes a soft switched Output Current Sourcing (OCS) grid connected inverter that applies a high sourcing inverters where the small disturbance at the line voltage may lead to current run away

69

436 IEEE/ASME TRANSACTIONS ON MECHATRONICS, VOL. 9, NO. 2, JUNE 2004 Torque and Velocity Ripple Elimination of AC  

E-Print Network (OSTI)

Elimination of AC Permanent Magnet Motor Control Systems Using the Internal Model Principle Wai-Chuen Gan and velocity ripple elimination in AC permanent magnet (PM) motor control systems. The torque ripples caused-free output response. Index Terms--AC permanent magnet motor, gain scheduled (GS) speed regulators, internal

Qiu, Li

70

Research on Energy Efficiency of DC Distribution System  

Science Journals Connector (OSTI)

Abstract Energy efficiency of DC distribution systems is researched in this paper. Efficiency calculation models of feeders and loads are established, efficiencies of AC/DC, DC/DC and DC/AC are analyzed. Moreover, energy efficiencies of an AC system and two DC systems, monopole and bipolar, are calculated and compared. The efficiency improvement of office building supplied by DC power system compared to supply by AC power system is demonstrated. From analysis, it is showed that the energy efficiency is higher in DC distribution system than AC distribution system.

Zifa Liu; Mengyu Li

2014-01-01T23:59:59.000Z

71

Maximizing Power Output in Homogeneous Charge Compression Ignition (HCCI) Engines and Enabling Effective Control of Combustion Timing  

E-Print Network (OSTI)

heat loss, while excessively delayed combustion timing (before misfire) can cause power output and efficiency losses because of incomplete oxidation of hydrocarbons

Saxena, Samveg

2011-01-01T23:59:59.000Z

72

AC PV Modules Take a standard DC PV module and connect a microinverter  

E-Print Network (OSTI)

modules. These inverters range in power from 700 watts up to 1 megawatt. DC maximum system voltages can and up to 13 inverters for the 210 W version to be installed on the same AC output cable. home power 136, and secure a listing to UL1741 for a pre-assembled module/inverter device, and you have an AC PV module

Johnson, Eric E.

73

ePOWER Seminar AC solar cells: A new breed of PV power generation  

E-Print Network (OSTI)

ePOWER Seminar AC solar cells: A new breed of PV power generation Professor Faisal Khan Assistant dc output which needs to be processed and inverted for ac applications. Using a modern manufacturing facility, PV panels could be mass produced without any apparent issues. Unfortunately, power converters

Abolmaesumi, Purang

74

Accommodation & ACS Advertising Policy  

E-Print Network (OSTI)

Accommodation & Campus Services. ACS Advertising Policy This paper states the University department Accommodation & Campus Services' (ACS) policy on advertising, sponsorship and promotions and any restrictions. Accommodation & Campus Services, the Students' Union, all affiliated bodies and advertisers are expected

Stevenson, Mark

75

ACS-GDCh ALLIANCE  

Science Journals Connector (OSTI)

ACS-GDCh ALLIANCE ... Other aspects of the strategic collaboration alliance will identify additional activities and services that could be mutually beneficial to both ACS and GDCh members, in keeping with both organizations’ strategic goals. ...

MADELEINE JACOBS

2010-09-20T23:59:59.000Z

76

Measurement and Modeling of Solar and PV Output Variability: Preprint  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Measurement and Modeling of Measurement and Modeling of Solar and PV Output Variability Preprint M. Sengupta To be presented at SOLAR 2011 Raleigh, North Carolina May 17-21, 2011 Conference Paper NREL/CP-5500-51105 April 2011 NOTICE The submitted manuscript has been offered by an employee of the Alliance for Sustainable Energy, LLC (Alliance), a contractor of the US Government under Contract No. DE-AC36-08GO28308. Accordingly, the US Government and Alliance retain a nonexclusive royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for US Government purposes. This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty,

77

Control of XeF laser output by pulse injecton  

SciTech Connect

Injection locking is investigated as a means for control of optical pulse duration and polarization in a XeF laser. Intense short-pulse generation in the ultraviolet is achieved by injection of a low-level 1-ns optical pulse into a XeF oscillator. Control of laser output polarization by injection locking is demonstrated and studied as a function of injected signal level. Enhancement of XeF electric-discharge laser efficiency by injection pulse ''priming'' is observed.

Pacala, T.J.; Christensen, C.P.

1980-04-15T23:59:59.000Z

78

Three phase AC motor controller  

DOE Patents (OSTI)

A motor controller for a three phase AC motor (10) which is adapted to operate bidirectionally from signals received either from a computer (30) or a manual control (32). The controller is comprised of digital logic circuit means which implement a forward and reverse command signal channel (27, 29) for the application of power through the forward and reverse power switching relays (16, 18, 20, 22). The digital logic elements are cross coupled to prevent activation of both channels simultaneously and each includes a plugging circuit (65, 67) for stopping the motor upon the removal of control signal applied to one of the two channels (27, 29) for a direction of rotation desired. Each plugging circuit (65, 67) includes a one-shot pulse signal generator (88, 102) which outputs a single pulse signal of predetermined pulsewidth which is adapted to inhibit further operation of the application of power in the channel which is being activated and to apply a reversal command signal to the other channel which provides a reversed phase application of power to the motor for a period defined by the pulse-width output of the one-shot signal generator to plug the motor (10) which will then be inoperative until another rotational command signal is applied to either of the two channels.

Vuckovich, Michael (Elizabeth, PA); Wright, Maynard K. (Bethel Park, PA); Burkett, John P. (South Huntington Township, Westmoreland County, PA)

1984-03-20T23:59:59.000Z

79

Celebrate Earth Day with ACS  

Science Journals Connector (OSTI)

Celebrate Earth Day with ACS ... Winners of the ACS-sponsored Earth Day 2004 music video contest are reported. ... ACS resources for celebrating the Earth Day 2005 theme, "Air—Here, There, Everywhere", are discussed. ...

Erica K. Jacobsen

2005-03-01T23:59:59.000Z

80

7AC Technologies, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC 7AC Technologies, Inc. America's Next Top Energy Innovator Challenge 498 likes 7AC Technologies, Inc. National Renewable Energy Laboratory Air conditioning is a very large contributor to U.S. and world energy consumption. Heating and cooling costs for commercial and industrial buildings exceed 25 percent of U.S. primary energy consumption (cooling alone accounts for 4.5 Quads out of 40 Quads) and typically accounts for almost half of a building's operating costs. Air conditioning is also a significant cause of grid instability with cycling compressor motors turning on and off, and causing load issues on hot summer days. Conventional air conditioners improve efficiency only marginally every year and retrofitting older rooftop units does not result in significant energy

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

7AC Technologies, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC 7AC Technologies, Inc. America's Next Top Energy Innovator Challenge 498 likes 7AC Technologies, Inc. National Renewable Energy Laboratory Air conditioning is a very large contributor to U.S. and world energy consumption. Heating and cooling costs for commercial and industrial buildings exceed 25 percent of U.S. primary energy consumption (cooling alone accounts for 4.5 Quads out of 40 Quads) and typically accounts for almost half of a building's operating costs. Air conditioning is also a significant cause of grid instability with cycling compressor motors turning on and off, and causing load issues on hot summer days. Conventional air conditioners improve efficiency only marginally every year and retrofitting older rooftop units does not result in significant energy

82

7AC Technologies, Inc. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7AC 7AC Technologies, Inc. America's Next Top Energy Innovator Challenge 498 likes 7AC Technologies, Inc. National Renewable Energy Laboratory Air conditioning is a very large contributor to U.S. and world energy consumption. Heating and cooling costs for commercial and industrial buildings exceed 25 percent of U.S. primary energy consumption (cooling alone accounts for 4.5 Quads out of 40 Quads) and typically accounts for almost half of a building's operating costs. Air conditioning is also a significant cause of grid instability with cycling compressor motors turning on and off, and causing load issues on hot summer days. Conventional air conditioners improve efficiency only marginally every year and retrofitting older rooftop units does not result in significant energy

83

Anisotropic Grid Adaptation for Multiple Aerodynamic Outputs  

E-Print Network (OSTI)

Anisotropic grid–adaptive strategies are presented for viscous flow simulations in which the accurate prediction of multiple aerodynamic outputs (such as the lift, drag, and moment coefficients) is required from a single ...

Venditti, David A.

84

Predicting the Energy Output of Wind Farms Based on Weather Data: Important Variables and their Correlation  

E-Print Network (OSTI)

Wind energy plays an increasing role in the supply of energy world-wide. The energy output of a wind farm is highly dependent on the weather condition present at the wind farm. If the output can be predicted more accurately, energy suppliers can coordinate the collaborative production of different energy sources more efficiently to avoid costly overproductions. With this paper, we take a computer science perspective on energy prediction based on weather data and analyze the important parameters as well as their correlation on the energy output. To deal with the interaction of the different parameters we use symbolic regression based on the genetic programming tool DataModeler. Our studies are carried out on publicly available weather and energy data for a wind farm in Australia. We reveal the correlation of the different variables for the energy output. The model obtained for energy prediction gives a very reliable prediction of the energy output for newly given weather data.

Vladislavleva, Katya; Neumann, Frank; Wagner, Markus

2011-01-01T23:59:59.000Z

85

Microfabricated AC impedance sensor  

DOE Patents (OSTI)

A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

Krulevitch, Peter (Pleasanton, CA); Ackler, Harold D. (Sunnyvale, CA); Becker, Frederick (Houston, TX); Boser, Bernhard E. (Berkeley, CA); Eldredge, Adam B. (Austin, TX); Fuller, Christopher K. (Livermore, CA); Gascoyne, Peter R. C. (Bellaire, TX); Hamilton, Julie K. (Tracy, CA); Swierkowski, Stefan P. (Livermore, CA); Wang, Xiao-Bo (San Diego, CA)

2002-01-01T23:59:59.000Z

86

NAO Climatology: ROMS output is saved once every 3 days and written to an output file  

E-Print Network (OSTI)

NAO Climatology: ROMS output is saved once every 3 days and written to an output file every 6 days Output after 30 days in 6th file. The Starting Month = July Example: roms_low_his_levts0570dg.0120.nc.gz : July 3 roms_low_his_levts0570dg.0122.nc.gz : July 6 and July 9 roms_low_his_levts0570dg.0124.nc

Gangopadhyay, Avijit

87

PV output smoothing with energy storage.  

SciTech Connect

This report describes an algorithm, implemented in Matlab/Simulink, designed to reduce the variability of photovoltaic (PV) power output by using a battery. The purpose of the battery is to add power to the PV output (or subtract) to smooth out the high frequency components of the PV power that that occur during periods with transient cloud shadows on the PV array. The control system is challenged with the task of reducing short-term PV output variability while avoiding overworking the battery both in terms of capacity and ramp capability. The algorithm proposed by Sandia is purposely very simple to facilitate implementation in a real-time controller. The control structure has two additional inputs to which the battery can respond. For example, the battery could respond to PV variability, load variability or area control error (ACE) or a combination of the three.

Ellis, Abraham; Schoenwald, David Alan

2012-03-01T23:59:59.000Z

88

EA-1926: Energy Efficiency Design Standards for New Federal Low...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

EA-1926: Energy Efficiency Design Standards for New Federal Low-Rise Residential Buildings (RIN 1904-AC61) EA-1926: Energy Efficiency Design Standards for New Federal Low-Rise...

89

Gesture output: eyes-free output using a force feedback touch surface  

Science Journals Connector (OSTI)

We propose using spatial gestures not only for input but also for output. Analogous to gesture input, the proposed gesture output moves the user's finger in a gesture, which the user then recognizes. We use our concept in a mobile scenario where a motion ... Keywords: eyes free, force feedback, gestures, touch

Anne Roudaut; Andreas Rau; Christoph Sterz; Max Plauth; Pedro Lopes; Patrick Baudisch

2013-04-01T23:59:59.000Z

90

Single Inductor Dual Output Buck Converter  

E-Print Network (OSTI)

of value 3V. The main focus areas are low cross regulation between the outputs and supply of completely independent load current levels while maintaining desired values (1.2V,1.5 V) within well controlled ripple levels. Dynamic hysteresis control is used...

Eachempatti, Haritha

2010-07-14T23:59:59.000Z

91

Bioenergy technology balancing energy output with environmental  

E-Print Network (OSTI)

E2.3 Bioenergy technology ­ balancing energy output with environmental benefitsbenefits John standards #12;Is it right to grow bioenergy? Or How much bioenergy production is right? #12;Historical bioenergy Farmers historically used 25% land for horse feed #12;Energy crops are `solar panels' Solar energy

Levi, Ran

92

Modeling Multi Output Filtering Effects in PCMOS  

E-Print Network (OSTI)

Modeling Multi Output Filtering Effects in PCMOS Anshul Singh*, Arindam Basu, Keck-Voon Ling, Nanyang Technological University (NTU), Singapore *NTU-Rice Institute of Sustainable and Applied Infodynamics (ISAID), NTU, Singapore $School of Computer Engineering, NTU, Singapore §School of ECE, Georgia

Mooney, Vincent

93

Title Slide "The broadband acoustic output of  

E-Print Network (OSTI)

Title Slide "The broadband acoustic output of marine seismic airgun sources" Les Hatton CISM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #12;Seismic sources ­ marine airguns Introduction Modelling Marine Life Impact Where next Overview #12 Normal speed surface movie of airgun firing Courtesy IO limited #12;Seismic sources ­ marine airguns

Hatton, Les

94

U.S. Motor Vehicle Output and Other GDP, 1968-2007  

NLE Websites -- All DOE Office Websites (Extended Search)

Motor Vehicle Output and Other GDP, 1968-2007 Motor Vehicle Output and Other GDP, 1968-2007 Danilo J. Santini, Ph. D. Senior Economist Center for Transportation Research Argonne National Laboratory 9700 South Cass Avenue Phone: 630 252 3758 Fax: 630 252 3443 E-mail: dsantini@anl.gov David A Poyer, Ph.D. Associate Professor of Economics Morehouse College 830 Westview Dr. SW Atlanta, GA 30314 Phone: 404 681 2800, ext. 2553 E-mail: dpoyer@morehouse.edu THE 66th INTERNATIONAL ATLANTIC ECONOMIC CONFERENCE Montreal, Canada 9-12 October 2008 BUSINESS FLUCTUATIONS AND CYCLES 12 October 2008 Sunday 11:15 AM - 1:15 PM The submitted manuscript has been created by UChicago Argonne, LLC, Operator of Argonne National Laboratory ("Argonne"). Argonne, a U.S. Department of Energy Office of Science laboratory, is operated under Contract No. DE-AC02-06CH11357. . The U.S. Government

95

ACS | Open Energy Information  

Open Energy Info (EERE)

ACS ACS Jump to: navigation, search Name ACS Place Madrid, Spain Zip 28036 Sector Solar Product Madrid based construction company involved in the development of solar thermal projects. Coordinates 40.4203°, -3.705774° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.4203,"lon":-3.705774,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

96

AC | OpenEI  

Open Energy Info (EERE)

AC AC Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

97

ETA-AC002  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 Revision 2 Effective March 1, 1997 "Control of Test Conduct" Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Jude M. Clark Approved by: _________________________________________________ Date: _______________ Donald B. Karner Procedure ETA-AC002 Revision 2 2 ©1997 Electric Transportation Applications All Rights Reserved TABLE OF CONTENTS 1.0 Objectives 3 2.0 Purpose 3 3.0 Documentation 3 4.0 Initial Conditions and Prerequisites 4 5.0 Personnel Qualifications 5 6.0 Activity Requirements 6 7.0 Supplemental Activity Requirements 8 8.0 Glossary 9 9.0 References 10 Procedure ETA-AC002 Revision 2 3 ©1997

98

ETA-AC006  

NLE Websites -- All DOE Office Websites (Extended Search)

6 6 Revision 2 Effective: March 1, 1997 Vehicle Verification Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Jude M. Clark Approved by: _________________________________________________ Date: ______________ Donald B. Karner ETA-AC006 Revision 2 2 ©1997 Electric Transportation Applications All Rights Reserved TABLE OF CONTENTS 1.0 Objectives 3 2.0 Purpose 3 3.0 Documentation 3 4.0 Initial Conditions and Prerequisites 4 5.0 Verification Requirements 5 6.0 Glossary 11 7.0 References 12 Appendices Appendix A - Manufacturer's Proposal Review Check List 13 Appendix B - Vehicle Receipt Check List 18 ETA-AC006 Revision 2 3

99

efficiency | OpenEI  

Open Energy Info (EERE)

efficiency efficiency Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

100

efficient | OpenEI  

Open Energy Info (EERE)

efficient efficient Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

DC-AC Cascaded H-Bridge Multilevel Boost Inverter With No Inductors for Electric/Hybrid Electric Vehicle Applications  

SciTech Connect

This paper presents a cascaded H-bridge multilevel boost inverter for electric vehicle (EV) and hybrid EV (HEV) applications implemented without the use of inductors. Currently available power inverter systems for HEVs use a dc-dc boost converter to boost the battery voltage for a traditional three-phase inverter. The present HEV traction drive inverters have low power density, are expensive, and have low efficiency because they need a bulky inductor. A cascaded H-bridge multilevel boost inverter design for EV and HEV applications implemented without the use of inductors is proposed in this paper. Traditionally, each H-bridge needs a dc power supply. The proposed design uses a standard three-leg inverter (one leg for each phase) and an H-bridge in series with each inverter leg which uses a capacitor as the dc power source. A fundamental switching scheme is used to do modulation control and to produce a five-level phase voltage. Experiments show that the proposed dc-ac cascaded H-bridge multilevel boost inverter can output a boosted ac voltage without the use of inductors.

Tolbert, Leon M [ORNL; Ozpineci, Burak [ORNL; Du, Zhong [ORNL; Chiasson, John N [ORNL

2009-01-01T23:59:59.000Z

102

Administrator Ready Reference Guide Customizing an Output Style  

E-Print Network (OSTI)

may be in various sections of the instructions. Some things to look for: - line spacing Preview Utility (Tools, Preview Output Styles) or by simply opening the Output Style Editor (Bibliography, Edit button -- to the right of the output style drop- down). The Output Style Preview Utility

University of Technology, Sydney

103

Generalized Input-Output Inequality Systems  

SciTech Connect

In this paper two types of generalized Leontief input-output inequality systems are introduced. The minimax properties for a class of functions associated with the inequalities are studied. Sufficient and necessary conditions for the inequality systems to have solutions are obtained in terms of the minimax value. Stability analysis for the solution set is provided in terms of upper semi-continuity and hemi-continuity of set-valued maps.

Liu Yingfan [Department of Mathematics, Nanjing University of Post and Telecommunications, Nanjing 210009 (China)], E-mail: yingfanliu@hotmail.com; Zhang Qinghong [Department of Mathematics and Computer Science, Northern Michigan University, Marquette, MI 49855 (United States)], E-mail: qzhang@nmu.edu

2006-09-15T23:59:59.000Z

104

Characterizing detonator output using dynamic witness plates  

SciTech Connect

A sub-microsecond, time-resolved micro-particle-image velocimetry (PIV) system is developed to investigate the output of explosive detonators. Detonator output is directed into a transparent solid that serves as a dynamic witness plate and instantaneous shock and material velocities are measured in a two-dimensional plane cutting through the shock wave as it propagates through the solid. For the case of unloaded initiators (e.g. exploding bridge wires, exploding foil initiators, etc.) the witness plate serves as a surrogate for the explosive material that would normally be detonated. The velocity-field measurements quantify the velocity of the shocked material and visualize the geometry of the shocked region. Furthermore, the time-evolution of the velocity-field can be measured at intervals as small as 10 ns using the PIV system. Current experimental results of unloaded exploding bridge wire output in polydimethylsiloxane (PDMS) witness plates demonstrate 20 MHz velocity-field sampling just 300 ns after initiation of the wire.

Murphy, Michael John [Los Alamos National Laboratory; Adrian, Ronald J [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

105

Broadband Diffractive Optics for Enhancing the Efficiency of Solar Cells  

Science Journals Connector (OSTI)

We propose a broadband diffractive optics based spectrum splitting approach to enhance the efficiency of solar cells. Numerical simulations indicate ~27% and ~45% increase in output...

Menon, Rajesh; Wang, Peng; Mohammed, Nabil

106

A direct AC-to-DC converter topology with high-frequency isolation  

E-Print Network (OSTI)

-to-ac converter eliminating the acto-dc rectification stage, power factor correction boost stage, and dc-dc converter stage present in the conventional system. The output of the high-frequency isolation transformer is rectified and processed via a filtering stage...

Sulistyono, Widodo

2012-06-07T23:59:59.000Z

107

Measured Savings of DC to AC Drive Retrofit in Plastic Extrusion  

E-Print Network (OSTI)

This paper presents the potential electrical energy efficiency improvements for utilizing alternating current (AC) motors controlled by variable frequency drives (VFD) in place of direct current (DC) motors to drive plastic extrusion machines. A...

Sfeir, R. A.

2008-01-01T23:59:59.000Z

108

Off-set stabilizer for comparator output  

DOE Patents (OSTI)

A stabilized off-set voltage is input as the reference voltage to a comparator. In application to a time-interval meter, the comparator output generates a timing interval which is independent of drift in the initial voltage across the timing capacitor. A precision resistor and operational amplifier charge a capacitor to a voltage which is precisely offset from the initial voltage. The capacitance of the reference capacitor is selected so that substantially no voltage drop is obtained in the reference voltage applied to the comparator during the interval to be measured.

Lunsford, James S. (Los Alamos, NM)

1991-01-01T23:59:59.000Z

109

Development of a 402.5 MHz 140 kW Inductive Output Tube  

SciTech Connect

This report contains the results of Phase I of an SBIR to develop a Pulsed Inductive Output Tube (IOT) with 140 kW at 400 MHz for powering H-proton beams. A number of sources, including single beam and multiple beam klystrons, can provide this power, but the IOT provides higher efficiency. Efficiencies exceeding 70% are routinely achieved. The gain is typically limited to approximately 24 dB; however, the availability of highly efficient, solid state drivers reduces the significance of this limitation, particularly at lower frequencies. This program initially focused on developing a 402 MHz IOT; however, the DOE requirement for this device was terminated during the program. The SBIR effort was refocused on improving the IOT design codes to more accurately simulate the time dependent behavior of the input cavity, electron gun, output cavity, and collector. Significant improvement was achieved in modeling capability and simulation accuracy.

R. Lawrence Ives; Michael Read, Robert Jackson

2012-05-09T23:59:59.000Z

110

Consumers Energy (Electric) - Residential Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric) - Residential Energy Efficiency Program Electric) - Residential Energy Efficiency Program Consumers Energy (Electric) - Residential Energy Efficiency Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Ventilation Manufacturing Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Home Performance Comprehensive Assessment and Installations: $3500 Insulation: $1,025 Windows: $250 Program Info State Michigan Program Type Utility Rebate Program Rebate Amount CFL Lighting: Retailer Instant Discount Programmable Thermostat: $10 Central A/C and Heat Pumps: $150 - $250 Central A/C Tune up: $50 Ground Source Heat Pump: $200-$300

111

Roseville Electric - Commercial Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Energy Efficiency Rebate Program Commercial Energy Efficiency Rebate Program Roseville Electric - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Appliances & Electronics Commercial Lighting Lighting Home Weatherization Insulation Design & Remodeling Windows, Doors, & Skylights Program Info Expiration Date 6/30/2013 State California Program Type Utility Rebate Program Rebate Amount Unitary AC/Heat Pump: $120/ton or $500/ton Package Terminal AC/Heat Pumps: $125/unit Variable Frequency Drive: $120/hp Variable Speed Motor: $75/hp Window Film: $4/sq ft Shade Tree: $30/tree Desktop Computer Network Controller: $10/computer Cold Cathode Lamps: $4/lamp Ceramic Metal Halide: $20/lamp

112

Development of an AC Module System: Final Technical Report  

SciTech Connect

The GreenRay Inc. program focused on simplifying solar electricity and making it affordable and accessible to the mainstream population. This was accomplished by integrating a solar module, micro-inverter, mounting and monitoring into a reliable, 'plug and play' AC system for residential rooftops, offering the following advantages: (1) Reduced Cost: Reduction in installation labor with fewer components, faster mounting, faster wiring. (2) Maximized Energy Production: Each AC Module operates at its maximum, reducing overall losses from shading, mismatch, or module downtime. (3) Increased Safety. Electrical and fire safety experts agree that AC Modules have significant benefits, with no energized wiring or live connections during installation, maintenance or emergency conditions. (4) Simplified PV for a Broader Group of Installers. Dramatic simplification of design and installation of a solar power system, enabling faster and more efficient delivery of the product into the market through well-established, mainstream channels. This makes solar more accessible to the public. (5) Broadened the Rooftop Market: AC Modules enable solar for many homes that have shading, split roofs, or obstructions. In addition, due to the smaller building block size of 200W vs. 1000W, homeowners with budget limitations can start small and add to their systems over time. Through this DOE program GreenRay developed the all-in-one AC Module system with an integrated PV Module and microinverter, custom residential mounting and performance monitoring. Development efforts took the product from its initial concept, through prototypes, to a commercial product sold and deployed in the residential market. This pilot deployment has demonstrated the technical effectiveness of the AC Module system in meeting the needs and solving the problems of the residential market. While more expensive than the traditional central inverter systems at the pilot scale, the economics of AC Modules become more and more favorable as the product matures and is made in high volumes. GreenRay's early customers have been highly enthusiastic about the AC Module system benefits.

Suparna Kadam; Miles Russell

2012-06-15T23:59:59.000Z

113

FirstEnergy (Potomac Edison) - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Potomac Edison) - Residential Energy Efficiency Rebate Potomac Edison) - Residential Energy Efficiency Rebate Program FirstEnergy (Potomac Edison) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Construction Design & Remodeling Sealing Your Home Ventilation Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Room AC/Room AC Recycling: Limit 3 All Other Appliances: Limit 1 per household Home Performance Programs: 15% of cost for insulation Program Info Expiration Date 12/31/2014 State Maryland Program Type Utility Rebate Program Rebate Amount Refrigerator-Freezers: Up to $150 Freezers: $75 Room AC: $25 Clothes Washer: Up to $100

114

Simulation of one-minute power output from utility-scale photovoltaic generation systems.  

SciTech Connect

We present an approach to simulate time-synchronized, one-minute power output from large photovoltaic (PV) generation plants in locations where only hourly irradiance estimates are available from satellite sources. The approach uses one-minute irradiance measurements from ground sensors in a climatically and geographically similar area. Irradiance is translated to power using the Sandia Array Performance Model. Power output is generated for 2007 in southern Nevada are being used for a Solar PV Grid Integration Study to estimate the integration costs associated with various utility-scale PV generation levels. Plant designs considered include both fixed-tilt thin-film, and single-axis-tracked polycrystalline Si systems ranging in size from 5 to 300 MW{sub AC}. Simulated power output profiles at one-minute intervals were generated for five scenarios defined by total PV capacity (149.5 MW, 222 WM, 292 MW, 492 MW, and 892 MW) each comprising as many as 10 geographically separated PV plants.

Stein, Joshua S.; Ellis, Abraham; Hansen, Clifford W.

2011-08-01T23:59:59.000Z

115

Application of computer voice input/output  

SciTech Connect

The advent of microprocessors and other large-scale integration (LSI) circuits is making voice input and output for computers and instruments practical; specialized LSI chips for speech processing are appearing on the market. Voice can be used to input data or to issue instrument commands; this allows the operator to engage in other tasks, move about, and to use standard data entry systems. Voice synthesizers can generate audible, easily understood instructions. Using voice characteristics, a control system can verify speaker identity for security purposes. Two simple voice-controlled systems have been designed at Los Alamos for nuclear safeguards applicaations. Each can easily be expanded as time allows. The first system is for instrument control that accepts voice commands and issues audible operator prompts. The second system is for access control. The speaker's voice is used to verify his identity and to actuate external devices.

Ford, W.; Shirk, D.G.

1981-01-01T23:59:59.000Z

116

Coordinated Output Regulation of Multiple Heterogeneous Linear Systems  

E-Print Network (OSTI)

, the generalizations of coordination of multiple linear dynamic systems to the cooperative output regulation problemCoordinated Output Regulation of Multiple Heterogeneous Linear Systems Ziyang Meng, Tao Yang, Dimos V. Dimarogonas, and Karl H. Johansson Abstract-- The coordinated output regulation problem

Dimarogonas, Dimos

117

Greener Commercial A/C Units Becoming a Cool Item | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Greener Commercial A/C Units Becoming a Cool Item Greener Commercial A/C Units Becoming a Cool Item Greener Commercial A/C Units Becoming a Cool Item July 1, 2010 - 5:11pm Addthis Greener Commercial A/C Units Becoming a Cool Item Stephen Graff Former Writer & editor for Energy Empowers, EERE A new federal tax credit is helping McQuay International expand its line of energy-efficient HVAC products at two of its plants and bring back furloughed workers. With the help of a 48C manufacturing tax credit worth $2 million under the American Recovery and Reinvestment Act, McQuay's Minnesota and Virginia plants have been or will be upgraded and expanded to produce new lines of energy efficient products. The tax credit is playing a role, but offering a bigger-and more efficient-selection of HVAC products also came down to basic economics:

118

Alternative Fuels at AC Transit  

NLE Websites -- All DOE Office Websites (Extended Search)

Alternative Fuels at AC Transit Alternative Fuels at AC Transit Speaker(s): Jaimie Levin Date: November 1, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Eve Edelson Mr. Levin will discuss AC Transit's range of environmental technology initiatives, including: zero emission fuel cell transit buses; state-of-the-art, high-capacity, hydrogen fueling stations; solar energy systems; and stationary solid oxide fuel cell power generators. AC Transit has the largest fleet of fuel cell buses in the United States, featuring fuel cell systems with more than 10,000 hours of continuous operation without any failures or power degradation. Their fuel cell fleet has logged more than 400,000 miles of service and carried in excess of one million passengers. Come hear what AC Transit has learned, where they're headed,

119

AC resistance measuring instrument  

DOE Patents (OSTI)

An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

Hof, P.J.

1983-10-04T23:59:59.000Z

120

Efficient template attacks  

E-Print Network (OSTI)

joint MD , d joint LINEAR. 6 Evaluation of Methods We evaluated the efficiency of many template-attack variants on a real hard- ware platform, comparing all the compression methods from Table 110 and all 9 MATLAB, single core CPU with 3794 MIPS. 10 We... implementing template attacks. Data and Code Availability: In the interest of reproducible research we make available our data and associated MATLAB scripts at: http://www.cl.cam.ac.uk/research/security/datasets/grizzly/ Acknowledgement: Omar Choudary is a...

Choudary, Omar; Kuhn, Markus G.

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Effect of local government expenditure on the ratio of output to capital: Evidence from panel data at China’s provincial level  

Science Journals Connector (OSTI)

This paper divides the expenditure of local government into the productive and nonproductive expenditure for revealing the effect of local government’s expenditure on output-capital efficiency through model and e...

Tao Jin; Jianhui Zhang

2011-06-01T23:59:59.000Z

122

A Novel Inductor-less DC-AC Cascaded H-bridge Multilevel Boost Inverter for Electric/Hybrid Electric Vehicle Applications  

SciTech Connect

This paper presents an inductorless cascaded H- bridge multilevel boost inverter for EV and HEV applications. Currently available power inverter systems for HEVs use a DC- DC boost converter to boost the battery voltage for a traditional 3-phase inverter. The present HEV traction drive inverters have low power density, are expensive, and have low efficiency because they need a bulky inductor. An inductorless cascaded H-bridge multilevel boost inverter for EV and HEV applications is proposed in this paper. Traditionally, each H-bridge needs a DC power supply. The proposed inductorless cascaded H-bridge multilevel boost inverter uses a standard 3-leg inverter (one leg for each phase) and an H-bridge in series with each inverter leg which uses a capacitor as the DC power source. Fundamental switching scheme is used to do modulation control and to produce a 5-level phase voltage. Experiments show that the proposed inductorless DC-AC cascaded H-bridge multilevel boost inverter can output a boosted AC voltage.

Du, Zhong [ORNL; Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL; Chiasson, John N [ORNL

2007-01-01T23:59:59.000Z

123

Modesto Irrigation District - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Modesto Irrigation District - Residential Energy Efficiency Rebate Modesto Irrigation District - Residential Energy Efficiency Rebate Program Modesto Irrigation District - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Sealing Your Home Ventilation Heat Pumps Water Heating Program Info Expiration Date 12/15/2013 State California Program Type Utility Rebate Program Rebate Amount Room AC: $50 Clothes Washer: $35 Water Heater: $25 Heat Pump Water Heater: $100 Refrigerator/Freezer Recycling: $35 per unit Central AC: $250 Heat Pump: $350 High Efficiency AC/Heat Pump: $500 Mini-Split AC/Heat Pump: $500 Air Duct Sealing: up to $250 max Whole House Fan: $100 per unit

124

A robust coordinated control scheme for HVDC transmission with parallel AC systems  

SciTech Connect

This paper introduces a practical control philosophy for HVDC transmission in parallel operation to an AC system with particular emphasis on coordination of both transient and dynamic stability. Systematic development of the control scheme on the basis of on-line identification, optimal control and rule-based bang-optimal coordination principles is presented. Verification tests of the scheme on a physical HVDC/AC system simulator show that the simple control computer algorithm is practical and robust. The controller can successfully distinguish between different system fault severities and adapts its output signals to provide maximum synchronizing torque and ensure optimal damping of power oscillations.

To, K.W.V.; David, A.K. (Hong Kong Polytechnic (Hong Kong). Dept. of Electrical Engineering); Hammad, A.E. (N.E. Swiss Power Co., Baden (Switzerland))

1994-07-01T23:59:59.000Z

125

Digital ac monitor  

DOE Patents (OSTI)

An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.

Hart, G.W.; Kern, E.C. Jr.

1987-06-09T23:59:59.000Z

126

AC conductivity of nanoporous metal-oxide photoanodes for solar energy conversion  

E-Print Network (OSTI)

AC conductivity of nanoporous metal-oxide photoanodes for solar energy conversion Steven J. Konezny% solar-to-electric energy conversion efficiency) exploited the large surface area of nanoporous thin of nanoporous thin films without increasing the recombination rate. To ensure efficient charge carrier

Konezny, Steven J.

127

Compact waveguide power divider with multiple isolated outputs  

DOE Patents (OSTI)

A waveguide power divider (10) for splitting electromagnetic microwave power and directionally coupling the divided power includes an input waveguide (21) and reduced height output waveguides (23) interconnected by axial slots (22) and matched loads (25) and (26) positioned at the unused ends of input and output guides (21) and (23) respectively. The axial slots are of a length such that the wave in the input waveguide (21) is directionally coupled to the output waveguides (23). The widths of input guide (21) and output guides (23) are equal and the width of axial slots (22) is one half of the width of the input guide (21).

Moeller, Charles P. (Del Mar, CA)

1987-01-01T23:59:59.000Z

128

GAMS program used to estimate capacity output using a distance function with both good and bad output, variable returns to scale and weak disposability of the bad outputs.  

E-Print Network (OSTI)

." VIMS Marine resource Report N. 2007-6. August 2007. Author: John B. Walden NMFS/NEFSC 166 Water St(obs) weights ; POSITIVE Variable weight, lambda; EQUATIONS CONSTR1(GOUTPUT, OBS) DEA constraint for each output

129

Xcel Energy (Electric) - Residential Energy Efficiency Rebate Programs |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate Residential Energy Efficiency Rebate Programs Xcel Energy (Electric) - Residential Energy Efficiency Rebate Programs < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Ventilation Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate Evaporative Cooling: $1000 High Efficiency A/C: $1000 Insulation: $300 Program Info Start Date 1/1/2011 Expiration Date 12/31/2012 State Colorado Program Type Utility Rebate Program Rebate Amount Refrigerator Recycling: $50 A/C and Heat Pumps: $500-$1100 Evaporative Cooling (Standard System): $100-$250/unit Evaporative Cooling (Premium System): $500-$600/unit

130

Wellesley Municipal Light Plant - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Wellesley Municipal Light Plant - Residential Energy Efficiency Wellesley Municipal Light Plant - Residential Energy Efficiency Rebate Program Wellesley Municipal Light Plant - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Maximum Rebate Two equipment rebates per customer per calendar year Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Refrigerator: $100 Clothes Washing Machine: $75 Central AC: $100 Room AC Unit: $50 Dishwasher: $75 Dehumidifier: $50 Provider Appliance Rebate Program Wellesley Municipal Light Plant (WMLP) offers a number of appliance rebates to residential customers who purchase and install energy efficient equipment. Rebates are available for refrigerators, dishwashers, clothes

131

Colorado Springs Utilities - Commercial Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Energy Efficiency Rebate Commercial Energy Efficiency Rebate Program Colorado Springs Utilities - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Schools Savings Category Appliances & Electronics Commercial Lighting Lighting Home Weatherization Windows, Doors, & Skylights Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Manufacturing Maximum Rebate Visit website for details Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Windows: $1.40/sq. ft. Lighting: Varies Electronically Commutated Motors: $60/unit Evaporative Cooling Systems: $162.50/ton Belts/Pulleys: $9.50/unit Packaged Terminal AC: $5.90/ton Central AC Unit: Varies Occupancy Sensor: $24.70 The Colorado Springs Utilities (CSU) Business Energy and Water Efficiency

132

FirstEnergy (West Penn Power) - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

West Penn Power) - Residential Energy Efficiency West Penn Power) - Residential Energy Efficiency Rebate Program FirstEnergy (West Penn Power) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Room AC/Room AC Recycling: Limit 3 All Other Appliances: Limit 1 per household Program Info State Pennsylvania Program Type Utility Rebate Program Rebate Amount Walk-Through Audit: Reduced customer fee of $50 Whole House Audit: $300 CFL's: $1.50 Clothes Washer: $75 Refrigerator: $50 Freezer: $25 Room AC: $25 Dehumidifiers: $10 Refrigerator Recycling: $50 Freezer Recycling: $50 Room AC Unit Recycling: $25

133

Fuel Cell Technologies Office Multi-Year Research, Development, and Demonstration Plan- Appendix B: Input/Output Matrix  

Energy.gov (U.S. Department of Energy (DOE))

Appendix B: Input/Output Matrix section of the Fuel Cell Technologies Office Multi-Year Research, Development, and Demonstration Plan; updated July 2013. This plan includes goals, objectives, technical targets, tasks, and schedules for the Office of Energy Efficiency and Renewable Energy's contribution to the DOE Hydrogen and Fuel Cells Program.

134

Constellation Shaping for Communication Channels with Quantized Outputs  

E-Print Network (OSTI)

average energy are selected more frequently than constellations with higher energy. However, the resultsConstellation Shaping for Communication Channels with Quantized Outputs Chandana Nannapaneni signal constellation and the output is quantized by a uniform scalar quantizer. The goal is to jointly

Valenti, Matthew C.

135

ANALOG-DIGITAL INPUT OUTPUT SYSTEM FOR APPLE CO  

E-Print Network (OSTI)

ADIOS ANALOG-DIGITAL INPUT OUTPUT SYSTEM FOR APPLE CO NATIONAL RADIO ASTRONOMY OBSERVATORY TABLES ADIOS - ANALOG-DIGITAL INPUT OUTPUT SYSTEM FOR APPLE COMPUTER TABLE FOR CONTENTS Page I Module and Apple Card (Photograph) Figure 3 Complete Apple/ADIOS System (Photograph) Figure 4 Analog

Groppi, Christopher

136

AC 95 - selected readings  

SciTech Connect

Reports are presented on energy efficiency and conservation in residential buildings. Topics include housing and energy linkages; the people factor; low-income initiatives; green visions; utility programs; affordable comfort; housing as a system; and pressures and air flow in buildings.

NONE

1995-12-31T23:59:59.000Z

137

Energy and exergy efficiencies of a solar box-cooker  

Science Journals Connector (OSTI)

A simple and low-cost box-type solar cooker (SBC) was designed and tested. The energy and exergy efficiencies of the SBC were experimentally evaluated. The energy output of the SBC ranges from 2.1 to 61.7 kJ, whereas the exergy output ranges from 0.4 to 6.2 kJ during the same time interval. The average daily energy and exergy outputs of the SBC are 21.6 and 2.5 kJ, respectively. A linear regression is developed to find the relationships between the energy/exergy outputs, and the efficiencies and temperature difference. The energy efficiency of the SBC varies between 1.3 and 55.6%, while the exergy efficiency varies between 0.3 and 6% during the same period. The average daily energy and exergy efficiencies of the SBC are 18.3 and 2.2%, respectively.

H. Huseyin Ozturk

2004-01-01T23:59:59.000Z

138

Indianola Municipal Utilities - Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Indianola Municipal Utilities - Energy Efficiency Rebate Program Indianola Municipal Utilities - Energy Efficiency Rebate Program Indianola Municipal Utilities - Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Central AC: $250 maximum; 10 unit maximum per customer per year Commercial Lighting: $5,000 per customer per year Air Source Heat Pumps: $500 maximum; 10 units per customer per year Geothermal Heat Pumps: $1,000 maximum, 5 units per customer per year Program Info State Iowa Program Type Utility Rebate Program Rebate Amount Central AC: $100/unit; $50 for each SEER above minimum Commercial Lighting: $2 - $25/fixture depending on type and efficiency

139

Marblehead Municipal Light Department - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marblehead Municipal Light Department - Residential Energy Marblehead Municipal Light Department - Residential Energy Efficiency Rebate Program Marblehead Municipal Light Department - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Maximum Rebate Insulation: $1,600 Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Refrigerators: $100, plus $25 for disposal of old refrigerator Clothes Washers: $50 - $100 Dishwashers: $25 - $50 Room A/C Units: 50% of purchase price up to $50 Central A/C: $325 - $525, varies by efficiency and technology Heat Pumps: $325 - $675, varies by efficiency and technology Programmable Thermostat: up to 50% of the purchase price

140

Output feedback control for robust tracking of position trajectories for DC electric motors  

Science Journals Connector (OSTI)

Abstract A generalized PI-like output feedback dynamic control scheme with additional integral compensation of the output error is proposed for robust tracking tasks of position reference trajectories for direct current electric motors with speed reduction gear head, using measurements of angular displacement only. The integral compensation is used to improve the robustness property of the controller, in regards to parametric uncertainty and variable load torque, and avoid the application of asymptotic estimation methods of the state vector. A family of Taylor polynomials approximates the perturbation signals, in order to reduce the control design complexity. These signals are compensated by the integral control action directly. Experimental and simulation results describe the effective performance of the control scheme proposed in this paper as an alternative solution to the efficient angular position control problem of direct current electric motors.

Francisco Beltran-Carbajal; Antonio Favela-Contreras; Antonio Valderrabano-Gonzalez; Julio Cesar Rosas-Caro

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Investigating Output Accuracy for a Discrete Event Simulation Model and an Agent Based Simulation Model  

E-Print Network (OSTI)

In this paper, we investigate output accuracy for a Discrete Event Simulation (DES) model and Agent Based Simulation (ABS) model. The purpose of this investigation is to find out which of these simulation techniques is the best one for modelling human reactive behaviour in the retail sector. In order to study the output accuracy in both models, we have carried out a validation experiment in which we compared the results from our simulation models to the performance of a real system. Our experiment was carried out using a large UK department store as a case study. We had to determine an efficient implementation of management policy in the store's fitting room using DES and ABS. Overall, we have found that both simulation models were a good representation of the real system when modelling human reactive behaviour.

Majid, Mazlina Abdul; Siebers, Peer-Olaf

2010-01-01T23:59:59.000Z

142

A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy  

E-Print Network (OSTI)

A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable of Energy Efficiency and Renewable Energy by Midwest Research Institute · Battelle Contract No. DE-AC36 .................................................................................................6 5 Wind Turbine

143

Intercounty Electric Cooperative - Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Intercounty Electric Cooperative - Energy Efficiency Rebate Program Intercounty Electric Cooperative - Energy Efficiency Rebate Program Intercounty Electric Cooperative - Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Water Heating Home Weatherization Windows, Doors, & Skylights Maximum Rebate Geothermal Heat Pump: $3,000 Program Info State Missouri Program Type Utility Rebate Program Rebate Amount Geothermal Heat Pump: $400 - 750/ton Air-to-Air or Duel Fuel Heat Pump: $150/ton Water Heater: $50 Room AC: $50/unit Provider Intercounty Electric Cooperative Intercounty Electric Cooperative provides rebates to its customers for the purchase of a variety of energy efficient equipment and appliances.

144

ACS calibration pipeline testing: error propagation  

E-Print Network (OSTI)

1 ACS calibration pipeline testing: error propagation Doug Van Orsow, Max Mutchler, Warren Hack files (see ISRs 99-03 "CALACS Operation and Implementation" by Hack and 99-04 "ACS calibra- tion

Sirianni, Marco

145

ACS SYMPOSIUM SERIES 966 Rational Environmental  

E-Print Network (OSTI)

ACS SYMPOSIUM SERIES 966 Rational Environmental Management of Agrochemicals Risk Assessment-Bayo, Editor Chiha University Sponsored by the ACS Division of Agrochemicals American Chemical Society of agrochemicals : risk assessment, monitoring, and remedial action / Ivan R. Kennedy, editor. ..[et al

Hammock, Bruce D.

146

ACS_RRA_2001.PDF  

NLE Websites -- All DOE Office Websites (Extended Search)

Qualitative and Semi-quantitative Qualitative and Semi-quantitative Analysis Of Semi-volatile Organics from Ambient Air Fine-particulate Matter, PM 2.5 Richard Anderson, Don Martello, Brian R. Strazisar and Curt M. White richard.anderson@netl.doe.gov ACS-222 / RRA' / ST-10 / 8-28-2001 Different Missions * EPA - Protect the public health * DOE - Assist the private sector in supplying clean, abundant, and affordable energy ACS-222 / RRA' / ST-10 / 8-28-2001 PM 2.5 Regulatory Process * 1997 National Ambient Air Quality Standards (NAAQS) for PM 2.5 based on "health effects" - Mean annual concentration < 15 ”g/m 3 - Maximum concentration < 65”g/ m 3 ACS-222 / RRA' / ST-10 / 8-28-2001 Why Is DOE Concerned About PM 2.5 ? * Coal-based power systems contribute to PM 2.5 - Primary particles * Ultra-fine fly-ash (Spherical Alumino-silicates,SAS), carbon soot

147

Sparse Convolved Gaussian Processes for Multi-output Regression  

E-Print Network (OSTI)

the concentration of different heavy metal pollutants [5]. Modelling multiple output variables is a challenge as we methodology for synthetic data and real world applications on pollution prediction and a sensor network. 1

Rattray, Magnus

148

Computability in Anonymous Networks: Revocable vs. Irrecovable Outputs  

E-Print Network (OSTI)

Computability in Anonymous Networks: Revocable vs. Irrecovable Outputs Yuval Emek1 , Jochen Seidel2, and leader election. 1 Introduction We study computability in networks, referred to hereafter as distributed

149

Failure mode and effects analysis outputs: are they valid?  

Science Journals Connector (OSTI)

Failure Mode and Effects Analysis (FMEA) is a prospective risk assessment tool that ... this study was to explore the validity of FMEA outputs within a hospital setting in the...

Nada Atef Shebl; Bryony Dean Franklin; Nick Barber

2012-06-01T23:59:59.000Z

150

Grid adaptation for functional outputs of compressible flow simulations  

E-Print Network (OSTI)

An error correction and grid adaptive method is presented for improving the accuracy of functional outputs of compressible flow simulations. The procedure is based on an adjoint formulation in which the estimated error in ...

Venditti, David Anthony, 1973-

2002-01-01T23:59:59.000Z

151

Community Climate System Model (CCSM) Experiments and Output Data  

DOE Data Explorer (OSTI)

The CCSM web makes the source code of various versions of the model freely available and provides access to experiments that have been run and the resulting output data.

152

Reliable Gas Turbine Output: Attaining Temperature Independent Performance  

E-Print Network (OSTI)

of availability, it is the major option for future power generation. One inherent disadvantage of gas turbines is the degradation of output as the ambient air temperature increases. This reduction in output during times of peak load create a reliability..., power generation for offshore platforms, utility peak load 58 ESL-IE-92-04-10 Proceedings from the 14th National Industrial Energy Technology Conference, Houston, TX, April 22-23, 1992 power generation, emergency power, ship propulsion, and private...

Neeley, J. E.; Patton, S.; Holder, F.

153

AEP (Central and SWEPCO) - Coolsaver A/C Tune Up | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

AEP (Central and SWEPCO) - Coolsaver A/C Tune Up AEP (Central and SWEPCO) - Coolsaver A/C Tune Up AEP (Central and SWEPCO) - Coolsaver A/C Tune Up < Back Eligibility Commercial Installer/Contractor Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Heat Pumps Program Info Funding Source AEP Texas (Central and SWEPCO) Companies State Texas Program Type Utility Rebate Program Rebate Amount $75 coupon/customer; contractor incentives Provider CLEAResult Consulting, Inc. Participating customers are eligible to receive a $75 coupon for use toward A/C and heat pump efficiency services performed as a result of the program's tune-up analysis. Residential and small commercial HVAC contractors that service customers served by SWEPCO may apply to

154

PEPCO - Residential Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PEPCO - Residential Energy Efficiency Rebate Program PEPCO - Residential Energy Efficiency Rebate Program PEPCO - Residential Energy Efficiency Rebate Program < Back Eligibility Low-Income Residential Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Construction Design & Remodeling Other Sealing Your Home Ventilation Commercial Lighting Lighting Water Heating Maximum Rebate CFL Bulbs: 25 per customer Room A/C:$125 (5 rebates) Program Info Funding Source Maryland Energy Administration State Maryland Program Type Utility Rebate Program Rebate Amount CFLs: $1.50/single and $3/multipack Clothes Washer: $50 - $100 Freezers: $75 Refrigerator: $100 - $150 Room A/C: $25 Dehumidifiers: $25 Tank Water Heater: $25

155

Anaheim Public Utilities - Residential Home Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Home Efficiency Rebate Residential Home Efficiency Rebate Program Anaheim Public Utilities - Residential Home Efficiency Rebate Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Manufacturing Commercial Lighting Lighting Windows, Doors, & Skylights Maximum Rebate Air Duct Repair: $300 Ceiling Fan: 3 fans Program Info State California Program Type Utility Rebate Program Rebate Amount Refrigerator: $50 Refrigerator Recycling: $50 Dishwasher: $50 Room A/C: $50 Central A/C: $100/ton High Performance windows: $1/sq ft Air Duct Repair: 50% of repair cost Ceiling Fan: $20 Whole House Fan: $100

156

AEP SWEPCO - Residential Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SWEPCO - Residential Energy Efficiency Rebate Program SWEPCO - Residential Energy Efficiency Rebate Program AEP SWEPCO - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Other Ventilation Manufacturing Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Windows, Doors, & Skylights Program Info State Arkansas Program Type Utility Rebate Program Rebate Amount '''Home Performance with ENERGY STARÂź''' Central AC Replacements: $125 - $800/system Heat Pump Replacements: $125 - $825/system Insulation: $0.12-$0.25/sq. ft. Duct Sealing/Replacement: $175 - $300/home Duct Insulation: $0.50/ln. ft. AC Tune-up: $80 Air Infiltration: $100 - $150

157

Norwich Public Utilities (Electric) - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Norwich Public Utilities (Electric) - Residential Energy Efficiency Norwich Public Utilities (Electric) - Residential Energy Efficiency Rebate Program Norwich Public Utilities (Electric) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Energy Star rebate: one rebate per appliance per residential utility customer Program Info Expiration Date 12/31/12 State Connecticut Program Type Utility Rebate Program Rebate Amount Refrigerators/Freezers: $60 Washing Machines: $60 Room AC: $60 Heat Pump Water Heater: $500 Central AC: $200 - $300/ton Dual Enthalpy Economizer Controls: $250 Air Source Heat Pump: $200 - $300/ton Geothermal Heat Pump: $150/ton

158

Fort Pierce Utilities Authority - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fort Pierce Utilities Authority - Residential Energy Efficiency Fort Pierce Utilities Authority - Residential Energy Efficiency Rebate Program Fort Pierce Utilities Authority - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Maximum Rebate Insulation: $300 Room A/C Units: 2 per household All other equipment: 1 per customer account Program Info State Florida Program Type Utility Rebate Program Rebate Amount Room A/C Unit: $150 Insulation: $0.40/sq ft (NEW); $0.125/sq ft (ADDED) Central A/C System/Heat Pumps: $50 - $2,100; varies by size and efficiency Programmable Thermostat: $25 Clothes Washer: $50 Refrigerator: $50 Provider Fort Pierce Utilities Authority

159

Barron Electric Cooperative - Energy Star Appliance and Energy Efficient  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Barron Electric Cooperative - Energy Star Appliance and Energy Barron Electric Cooperative - Energy Star Appliance and Energy Efficient Lighting Rebate Program Barron Electric Cooperative - Energy Star Appliance and Energy Efficient Lighting Rebate Program < Back Eligibility Agricultural Commercial Multi-Family Residential Nonprofit Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Wisconsin Program Type Utility Rebate Program Rebate Amount Clothes Washer: $25 Dishwasher: $25 Dehumidifier: $25 Refrigerator: $25 Room A/C: $25 Refrigerator or Freezer Recycling: up to $25 Room A/C Unit Recycling: up to $25 Central A/C: $40 - $80/ton Air-Source Heat Pump: $150/ton Geothermal Heat Pump: $300/ton Commercial A/C: $40/ton

160

Improvement of output coupling efficiency of organic light-emitting diodes by backside substrate modification  

E-Print Network (OSTI)

modification C. F. Madigan, M.-H. Lu, and J. C. Sturma) Center for Photonics and Optoelectronic Materials, Department of Electrical Engineering, Princeton University, Princeton, New Jersey 08544 Received 8 November and at least triple it when high-index plastic substrates are used. The work is accompa- nied by modeling

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Output-power fluctuations of flowing-gas CO/sub 2/ lasers with unstable resonators  

SciTech Connect

An experimental study was made of the influence of different factors on the stability of the output intensity of a flowing-gas CO/sub 2/ laser with an unstable resonator. The measured amplitude--frequency characteristics of the intensity fluctuation spectrum had resonance peaks at multiples of the frequency corresponding to the transit time of the gas to the optic axis of the resonator. A rise in the efficiency of the laser system was found to be accompanied by an increase in the amplitude of the fluctuations of the radiation intensity.

Artamonov, A.V.; Konev, V.A.; Likhanskii, V.V.; Napartovich, A.P.

1984-06-01T23:59:59.000Z

162

Water resource utilization efficiency and spatial spillover effects in China  

Science Journals Connector (OSTI)

Based on provincial panel data of water footprint and grey water footprint, and with the help of data ... the undesirable output, this paper estimates the water resources utilization efficiency in China from 1997...

Caizhi Sun; Liangshi Zhao; Wei Zou; Defeng Zheng

2014-10-01T23:59:59.000Z

163

TRIPLE OUTPUT POWER SUPPLY Agilent MODEL E3630A  

E-Print Network (OSTI)

, manufacture, and intended use of the instrument. Agilent Technologies assumes no liability for the customer, the instrument chassis and cabinet must be connected to an electrical ground. The instrument must be connected to the ac power supply mains through a three-conductor power cable, with the third wire firmly connected

Ravikumar, B.

164

NYSEG (Electric) - Commercial and Industrial Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial and Industrial Efficiency Program Commercial and Industrial Efficiency Program NYSEG (Electric) - Commercial and Industrial Efficiency Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit State Government Tribal Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate No maximum per customer rebate; however, NYSEG/RG&E reserve the right to cap the rebate to any one customer. Program Info State New York Program Type Utility Rebate Program Rebate Amount Lighting, HVAC: Prescriptive incentives vary A/C or Heat Pump A/C or Heat Pump > 63 tons: $25/ton + $5/ton for each 0.1 EER above 9.7 Water Cooled Chillers: $6/ton or $15/ton + $2-$8/ton for each 0.01 kW/ton

165

Entergy Arkansas - Residential Energy Efficiency Program (Arkansas) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Entergy Arkansas - Residential Energy Efficiency Program (Arkansas) Entergy Arkansas - Residential Energy Efficiency Program (Arkansas) Entergy Arkansas - Residential Energy Efficiency Program (Arkansas) < Back Eligibility Installer/Contractor Multi-Family Residential Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Other Sealing Your Home Ventilation Heat Pumps Appliances & Electronics Commercial Lighting Lighting Program Info State Arkansas Program Type Utility Rebate Program Rebate Amount $175 incentive toward the cost of a high-performance AC tune-up of a system size 5 tons or less $200 incentive toward the cost of a high-performance AC tune-up of a system size over 5 tons Tier 1 Home Energy Survey --- Survey $75 discount

166

Energy Efficiency and Conservation Block Grant Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

OK-TRIBE-IOWA TRIBE OF OKLAHOMA Energy Efficiency and Conservation Block Grant Program Location: Tribe OK-TRIBE-IOWA TRIBE OF OKLAHOMA OK American Recovery and Reinvestment Act: Proposed Action or Project Description The Iowa Tribe of Oklahoma proposes to develop an energy efficiency strategy and also attend workshops and training on retrofitting tribal buildings. In addition, building retrofits would be conducted on tribal buildings built around the 1989-2003 time period and would include: attic insulation, door weather stripping, caulk windows, repair air conditioning (A/C) units and replace line insulation, increase attic ventilation, replace and repair doors, replace inefficient A/C units with energy efficient units, install window film, roof insulation, hot water tank replacements and insulate lines, and installation of automatic controls

167

Interpreting and analyzing model output (A very cursory introduction) Here will talk briefly about using "ncview" and "matlab" to analyze output  

E-Print Network (OSTI)

using "ncview" and "matlab" to analyze output from your model. The model output is in netcdf format for the output. I use matlab to measure, plot, compute, etc.. Recall the the model output is stored in: /scratch shown at the top.) matlab I hope you have some experience with matlab. There are handy tutorials

Gerber, Edwin

168

ASSESSMENT OF THE EFFECTIVENESS AND ENERGY EFFICIENCY OF HUMIDITY CONTROL APPROACHES IN VACANT FLORIDA HOMES  

E-Print Network (OSTI)

, but it yielded insufficient RH control during cloudy weather. Furthermore, AC energy use peaks during the utility’s peak demand period. Running the AC system for two hours a day (3-5 AM) yielded effective and energy efficient RH control. Operation of a...

Cummings, J. B.; Withers, C. R.

169

M2ACS | M2ACS Web Space  

NLE Websites -- All DOE Office Websites (Extended Search)

Welcome to the Multifaceted Mathematics for Complex Energy Systems (M2ACS) Welcome to the Multifaceted Mathematics for Complex Energy Systems (M2ACS) project webspace We are a multi-institution project whose aim is to fully explore the opportunities in applied mathematics brought about by multi-disciplinary focus - involving optimization, dynamical systems, stochastic analysis, discrete mathematics, scalable algorithms - on the DOE Grand Challenge of energy systems. The central research concept is the one of multi-faceted mathematics - whereby new mathematics is discovered by sustained investigation of the multiple facets presented by the grand challenge subproblems, such as nonconvexity, stochasticity, integrality, spatio-temporal variability - from the perspective of all the mathematics discipline area involved. Our project involves 22 principal investigators from 3 national

170

DOE 10 CFR Part 431 EERE-2010-BT-TP-0036 RIN 1904-AC-38 Submission of Comments by Howe Corporation  

Energy.gov (U.S. Department of Energy (DOE))

Comments to the following DOE Proposed Rules:10 CFR Part 431[Docket No. EERE-2010-BT-TP-0036]RIN 1904-AC38Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures...

171

Input/Output of ab-initio nuclear structure calculations for improved performance and portability  

SciTech Connect

Many modern scientific applications rely on highly computation intensive calculations. However, most applications do not concentrate as much on the role that input/output operations can play for improved performance and portability. Parallelizing input/output operations of large files can significantly improve the performance of parallel applications where sequential I/O is a bottleneck. A proper choice of I/O library also offers a scope for making input/output operations portable across different architectures. Thus, use of parallel I/O libraries for organizing I/O of large data files offers great scope in improving performance and portability of applications. In particular, sequential I/O has been identified as a bottleneck for the highly scalable MFDn (Many Fermion Dynamics for nuclear structure) code performing ab-initio nuclear structure calculations. We develop interfaces and parallel I/O procedures to use a well-known parallel I/O library in MFDn. As a result, we gain efficient I/O of large datasets along with their portability and ease of use in the down-stream processing. Even situations where the amount of data to be written is not huge, proper use of input/output operations can boost the performance of scientific applications. Application checkpointing offers enormous performance improvement and flexibility by doing a negligible amount of I/O to disk. Checkpointing saves and resumes application state in such a manner that in most cases the application is unaware that there has been an interruption to its execution. This helps in saving large amount of work that has been previously done and continue application execution. This small amount of I/O provides substantial time saving by offering restart/resume capability to applications. The need for checkpointing in optimization code NEWUOA has been identified and checkpoint/restart capability has been implemented in NEWUOA by using simple file I/O.

Laghave, Nikhil

2010-12-15T23:59:59.000Z

172

Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges  

SciTech Connect

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

2013-10-15T23:59:59.000Z

173

Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges  

SciTech Connect

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

2014-06-19T23:59:59.000Z

174

Mansfield Municipal Electric Department - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mansfield Municipal Electric Department - Residential Energy Mansfield Municipal Electric Department - Residential Energy Efficiency Rebate Program Mansfield Municipal Electric Department - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Maximum Rebate $100 limit per customer account for appliances purchased in the same calendar year. Program Info Expiration Date 12/31/2014 State Massachusetts Program Type Utility Rebate Program Rebate Amount Central AC: $100 Refrigerators: $100 Clothes Washing Machines: $100 Dishwashers: $75 Dehumidifiers: $50 Window Air Conditioners: $50 Provider Mansfield Municipal Electric Department Mansfield Municipal Electric Department encourages energy efficiency

175

Carbon Capture, Transport and Storage Regulatory Test Exercise: Output  

Open Energy Info (EERE)

Carbon Capture, Transport and Storage Regulatory Test Exercise: Output Carbon Capture, Transport and Storage Regulatory Test Exercise: Output Report Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Carbon Capture, Transport and Storage Regulatory Test Exercise: Output Report Focus Area: Clean Fossil Energy Topics: Market Analysis Website: cdn.globalccsinstitute.com/sites/default/files/publications/7326/carbo Equivalent URI: cleanenergysolutions.org/content/carbon-capture-transport-and-storage- Policies: Regulations Regulations: Emissions Mitigation Scheme The Scottish Government published this report to identify regulatory gaps or overlaps in the nation's framework for regulating carbon capture and storage (CCS). The report aims to streamline and better manage CCS regulation. It focuses on evaluating the risks, barriers, information gaps,

176

OECD Input-Output Tables | Open Energy Information  

Open Energy Info (EERE)

OECD Input-Output Tables OECD Input-Output Tables Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Input-Output Tables Agency/Company /Organization: Organisation for Economic Co-Operation and Development Topics: Co-benefits assessment, Market analysis, Co-benefits assessment, Pathways analysis Resource Type: Dataset Website: www.oecd.org/document/3/0,3343,en_2649_34445_38071427_1_1_1_1,00.html Country: Sweden, Finland, Japan, South Korea, Argentina, Australia, China, Israel, United Kingdom, Portugal, Romania, Greece, Poland, Slovakia, Chile, India, Canada, New Zealand, United States, Denmark, Norway, Spain, Austria, Italy, Netherlands, Ireland, France, Belgium, Brazil, Czech Republic, Estonia, Germany, Hungary, Luxembourg, Mexico, Slovenia, South Africa, Turkey, Indonesia, Switzerland, Taiwan, Russia

177

Formalization of computer input and output: the Hadley model  

Science Journals Connector (OSTI)

Current digital evidence acquisition tools are effective, but are tested rather than formally proven correct. We assert that the forensics community will benefit in evidentiary ways and the scientific community will benefit in practical ways by moving beyond simple testing of systems to a formal model. To this end, we present a hierarchical model of peripheral input to and output from von Neumann computers, patterned after the Open Systems Interconnection model of networking. The Hadley model categorizes all components of peripheral input and output in terms of data flow; with constructive aspects concentrated in the data flow between primary memory and the computer sides of peripherals' interfaces. The constructive domain of Hadley is eventually expandable to all areas of the I/O hierarchy, allowing for a full view of peripheral input and output and enhancing the forensics community's capabilities to analyze, obtain, and give evidentiary force to data.

Matthew Gerber; John Leeson

2004-01-01T23:59:59.000Z

178

Electrospray mass spectrometry of NeuAc oligomers associated with the C fragment of the tetanus toxin  

SciTech Connect

The Clostridial neurotoxins, botulinum and tetanus, gain entry into neuronal cells by protein recognition involving cell specific binding sites. The sialic or N-acetylneuraminic acid (NeuAc) residues of gangliosides attached to the surface of motor neurons are the suspected recognition and interaction points with Clostridial neurotoxins, although not necessarily the only ones. We have used electrospray ionization mass spectrometry (ESIMS) to examine formation of complexes between the tetanus toxin C fragment, or targeting domain, and carbohydrates containing NeuAc groups to determine how NeuAc residues contribute to ganglioside binding. ESI-MS was used to rapidly and efficiently measure dissociation constants for a number of related NeuAc-containing carbohydrates and NeuAc oligomers, information that has helped identify the structural features of gangliosides that determine their binding to tetanus toxin. The strength of the interactions between the C fragment and (NeuAc){sub n}, are consistent with the topography of the targeting domain of tetanus toxin and the nature of its carbohydrate binding sites. The results suggest that the targeting domain of tetanus toxin contains two binding sites that can accommodate NeuAc (or a dimer). This study also shows that NeuAc must play an important role in ganglioside binding and molecular recognition, a process critical for normal cell function and one frequently exploited by toxins, bacteria and viruses to facilitate their entrance into cells.

Prieto, M C; Whittal, R M; Baldwin, M A; Burlingame, A L; Balhorn, R

2005-04-03T23:59:59.000Z

179

Regulatory Reform to Promote Clean Energy: The Potential of Output-Based Emissions Standards  

SciTech Connect

Barriers to industrial energy-efficient technologies hinder their use. A number of EPA analyses and industrial experts have found that the utilization of input-based emissions standards (measured in parts-per-million or pounds/MMBtu) in the Clean Air Act creates a regulatory barrier to the installation and deployment of technologies that emit fewer criteria pollutants and use energy more efficiently. Changing emission management strategies to an output-based emissions standard (measured in tons of pollutant emitted) is a way to ameliorate some of these barriers. Combined heat and power (CHP) is one of the key technologies that would see increased industrial application if the emissions standards were modified. Many states have made this change since the EPA first approved it in 2000, although direction from the Federal government could speed implementation modifications. To analyze the national impact of accelerated state adoption of output-based standards on CHP technologies, this paper uses detailed National Energy Modeling System (NEMS) and spreadsheet analysis illustrating two phased-in adoption scenarios for output-based emissions standards in the industrial sector. Benefit/cost metrics are calculated from a private and public perspective, and also a social perspective that considers the criteria and carbon air pollution emissions. These scenarios are compared to the reference case of AEO 2010 and are quite favorable, with a social benefit-cost ratio of 16.0 for a five-year phase-in scenario. In addition, the appropriateness of the Federal role, applicability, technology readiness, and administrative feasibility are discussed.

Cox, Matthew [Georgia Institute of Technology] [Georgia Institute of Technology; Brown, Dr. Marilyn Ann [Georgia Institute of Technology] [Georgia Institute of Technology; Jackson, Roderick K [ORNL] [ORNL

2011-01-01T23:59:59.000Z

180

Improving the dynamic performance of a complex AC/DC system by HVDC control modifications  

SciTech Connect

The power system of Hydro-Quebec has a peak load of approximately 27 GW. The great distance between the production sites and the load centers introduces stability limitations, which is the reason why the Quebec grid cannot be economically synchronized (through ac transmission with limited capacity) with the U.S. northeastern network. Power exports are therefore dependent on the use of HVDC links of which Hydro-Quebec now possesses five, for a capacity of over 2600 MW. Such a capacity will again soon increase. At the moment, the Chateauguay scheme has the largest HVDC capacity. It transfers 1000 MW by means of two Back-to-Back converter blocks. Various automatic control systems are installed on the Chateauguay scheme owing to the fact that a single circuit of a 765 kV ac line transmits the output of both the HVDC converter stations as well as the output from Beauharnois hydro generating station. Such controls have performed satisfactorily since 1984. However, a remarkable improvement of the overall ac/dc system dynamic performance can be gained by making certain modifications in some of these HVDC system controls. This paper presents the salient features of such control modifications, currently under consideration, using the results of an investigation by digital and analogue simulations that demonstrate the achieved improvements.

Hammad, A.E. (ABB Power Systems, Baden (CH)); Gagnon, J. (Hydro Quebec, Montreal (CA)); McCallum, D. (IREQ, Montreal (CA))

1990-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

SMECO - Residential Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SMECO - Residential Energy Efficiency Rebate Program SMECO - Residential Energy Efficiency Rebate Program SMECO - Residential Energy Efficiency Rebate Program < Back Eligibility Low-Income Residential Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Sealing Your Home Ventilation Heat Pumps Commercial Lighting Lighting Water Heating Program Info State Maryland Program Type Utility Rebate Program Rebate Amount Home Energy Audit: Free Home Performance Weatherization: up to $2,750 Central AC: $150 - $500 Air Source Heat Pump: $200 - $500 Geothermal Heat Pump: $500 Ductless Mini-Split AC/Heat Pump: $300 Duct Sealing: up to $250 HVAC Performance Tune-Up: $100 Room AC: $25 Refrigerator Recycling: $50 Clothes Washer: $50 - $100

182

Delmarva Power - Residential Energy Efficiency Rebate Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Delmarva Power - Residential Energy Efficiency Rebate Program Delmarva Power - Residential Energy Efficiency Rebate Program Delmarva Power - Residential Energy Efficiency Rebate Program < Back Eligibility Low-Income Residential Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Other Sealing Your Home Ventilation Water Heating Maximum Rebate Room A/C:$125 (5 rebates) Energy Wise Rewards A/C Cycling: up to $160 in the first year Program Info Funding Source Maryland Energy Administration State Maryland Program Type Utility Rebate Program Rebate Amount CFLs: $1.50/single and $3/multipack Clothes Washer: $50 - $100 Refrigerator: $100 - $150 Freezer: $75 Room A/C: $25 Dehumidifiers: $25 Electric Water Heater: $25 Heat Pump Water Heater: up to $300

183

APS - Residential Energy Efficient Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

APS - Residential Energy Efficient Rebate Program APS - Residential Energy Efficient Rebate Program APS - Residential Energy Efficient Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Sealing Your Home Ventilation Heat Pumps Appliances & Electronics Windows, Doors, & Skylights Maximum Rebate Duct Repairs: $250 Sealing Air Leaks: $250 Attic Insulation: $250 Pool Pumps: $200 Program Info State Arizona Program Type Utility Rebate Program Rebate Amount Heat Pumps/AC Units: $270 Insulation, Duct Repair and Air Sealing: 75% of cost Refrigerator Recycling: $30 Lighting: Store Discounts APS offers a $270 rebate to its residential customers who upgrade their AC units or heat pumps. AC units must meet both the SEER and EER values and be

184

Lassen Municipal Utility District - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lassen Municipal Utility District - Residential Energy Efficiency Lassen Municipal Utility District - Residential Energy Efficiency Rebate Program Lassen Municipal Utility District - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Windows: $500 Duct Insulation/Sealing: $500 Radiant Barrier: $1,000 Program Info State California Program Type Utility Rebate Program Rebate Amount Refrigerator: $50 Freezer: $50 Clothes Washer: $35 Dishwasher: $35 Room AC: $75 Air Source Heat Pumps: $100 - $400 per ton Ground Source Heat Pump: $1,000 per ton Central A/C: $25 - $150 per ton Evaporative Cooled A/C: $175 per ton Evaporative Coolers: $75 - $200 per 1,000 sq. ft.

185

Montana-Dakota Utilities - Commercial Energy Efficiency Incentive Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Montana-Dakota Utilities - Commercial Energy Efficiency Incentive Montana-Dakota Utilities - Commercial Energy Efficiency Incentive Program Montana-Dakota Utilities - Commercial Energy Efficiency Incentive Program < Back Eligibility Commercial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Commercial Lighting Lighting Manufacturing Maximum Rebate Lighting: Total incentive cannot exceed 50% of project cost Program Info State Montana Program Type Utility Rebate Program Rebate Amount Custom Lighting Incentive: $0.20/watt 4 ft Lighting Fixtures or Less: $1 - $14 8 ft Lighting Fixtures: $3 - $9 13W-42W Lighting Replacements: $9 - $22 LED Exit Sign: $6 CFL Exit: $3 Central AC: $100 - $200/ton Split System AC: $100/ton Packaged/Rooftop AC: $100/ton New Premium Motor: $4/HP Premium Replacement Motor: $15/HP

186

Consumers Energy (Gas) - Residential Energy Efficiency Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Gas) - Residential Energy Efficiency Program Gas) - Residential Energy Efficiency Program Consumers Energy (Gas) - Residential Energy Efficiency Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Commercial Weatherization Manufacturing Maximum Rebate Home Performance Comprehensive Assessment and Installations: $3500 Insulation: $1,025 Program Info State Michigan Program Type Utility Rebate Program Rebate Amount CFL Lighting: Retailer Instant Discount Programmable Thermostat: $10 Central A/C and Heat Pumps: $150 - $250 Central A/C Tune up: $50 Ground Source Heat Pump: $200-$300 Room A/C: $25 Dehumidifier: $25 ECM Blower: $100 Refrigerator Recycling: $30 Clothes Washer: $25-$50

187

Thermally efficient compact fluorescent fixture systems  

SciTech Connect

Compact fluorescent lamps that can be inserted into conventional light fixtures are rapidly gaining acceptance as both a viable retrofit and new design approach to reducing lighting loads. Ideally, the compact fluorescent lamp should have the same light output as the incandescent lamp it replaces, but overheating inside typically small enclosed fixtures can reduce lumen output and hence lighting fixture efficiency by 15 to 20 percent. Fortunately, simple fixture modifications can erase this efficiency penalty, so that the full efficiency benefit of replacing incandescent lamps with fluorescent lamps can be realized. The paper describes such modifications and presents experimental data documenting the potential efficiency enhancement associated with thermal control systems. 4 refs., 7 figs.

Siminovitch, M.J.; Rubinstein, F.M.; Packer, M.

1991-04-01T23:59:59.000Z

188

An input-output approach to analyze the ways to increase total output of energy sectors: The case of Japan  

Science Journals Connector (OSTI)

The purpose of this study is to analyze the ways to increase total output of Japanese energy sectors in future time. In this study, Input-Output (IO) analysis is employed as a tool of analysis. This study focuses on petroleum refinery products and non-ferrous metals as analyzed sectors. The results show that positive impact observed in export and outside households consumption modifications while opposite impact is given by modification of import. The recommendations suggested based on these results are Japanese government should make breakthroughs so analyzed sector's export activities can increase and they have to careful in conducting import activities related to these sectors.

Ubaidillah Zuhdi

2014-01-01T23:59:59.000Z

189

Output-Based Regulations: A Handbook for Air Regulators (U.S. EPA), August 2004  

Energy.gov (U.S. Department of Energy (DOE))

Handbook providing practical information to help regulators decide if they want to use output-based regulations and explains how to develop an output-based emission standard

190

Output-Sensitive Algorithms for Tukey Depth and Related Problems  

E-Print Network (OSTI)

Output-Sensitive Algorithms for Tukey Depth and Related Problems David Bremner University of New de Bruxelles Pat Morin Carleton University Abstract The Tukey depth (Tukey 1975) of a point p halfspace that contains p. Algorithms for computing the Tukey depth of a point in various dimensions

Morin, Pat

191

Soft-Input Soft-Output Sphere Decoding Christoph Studer  

E-Print Network (OSTI)

Soft-Input Soft-Output Sphere Decoding Christoph Studer Integrated Systems Laboratory ETH Zurich Laboratory ETH Zurich, 8092 Zurich, Switzerland Email: boelcskei@nari.ee.ethz.ch Abstract--Soft-input soft, 8092 Zurich, Switzerland Email: studer@iis.ee.ethz.ch Helmut Bölcskei Communication Technology

192

Maximizing output from oil reservoirs without water breakthrough  

E-Print Network (OSTI)

Maximizing output from oil reservoirs without water breakthrough S.K. Lucas School of Mathematics, revised May 2003, published 45(3), 2004, 401­422 Abstract Often in oil reservoirs a layer of water lies, for example, Muskat [8], Bear [1]). When oil is removed from the reservoir by an oil well, it will generate

Lucas, Stephen

193

AC corrosion on cathodically protected steel.  

E-Print Network (OSTI)

?? This report deals with the effect of alternating current on cathodically protected steel. AC corrosion has become relevant in the offshore industry due to… (more)

Torstensen, Andreas

2012-01-01T23:59:59.000Z

194

Design of AC substation grounding system.  

E-Print Network (OSTI)

??The purpose for this paper is to understand the basic foundation used to safely design a substation grounding system for AC systems. The following criteria… (more)

Meas, Ra

2014-01-01T23:59:59.000Z

195

Preston Public Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Preston Public Utilities - Residential Energy Efficiency Rebate Preston Public Utilities - Residential Energy Efficiency Rebate Program Preston Public Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum required EER Appliances

196

Lake City Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lake City Utilities - Residential Energy Efficiency Rebate Program Lake City Utilities - Residential Energy Efficiency Rebate Program Lake City Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: Varies, see program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum required EER Refrigerators: $25, plus $50 for recycling an old, working unit

197

Mora Municipal Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mora Municipal Utilities - Residential Energy Efficiency Rebate Mora Municipal Utilities - Residential Energy Efficiency Rebate Program Mora Municipal Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump: $200/ton, plus $25/ton for every 1 EER above minimum required EER

198

Litchfield Public Utilities - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Litchfield Public Utilities - Residential Energy Efficiency Rebate Litchfield Public Utilities - Residential Energy Efficiency Rebate Program Litchfield Public Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum required EER Appliances Refrigerators: $25, plus $50 for recycling an old, working unit

199

Fairmont Public Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fairmont Public Utilities - Residential Energy Efficiency Rebate Fairmont Public Utilities - Residential Energy Efficiency Rebate Program Fairmont Public Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump: $200/ton, plus $25/ton for every 1 EER above minimum required EER

200

Saint Peter Municipal Utilities - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Saint Peter Municipal Utilities - Residential Energy Efficiency Saint Peter Municipal Utilities - Residential Energy Efficiency Rebate Program Saint Peter Municipal Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Local Government Nonprofit Residential State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Wells Public Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Wells Public Utilities - Residential Energy Efficiency Rebate Wells Public Utilities - Residential Energy Efficiency Rebate Program Wells Public Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum required EER Appliances

202

Blooming Prairie Public Utilities - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Blooming Prairie Public Utilities - Residential Energy Efficiency Blooming Prairie Public Utilities - Residential Energy Efficiency Rebate Program Blooming Prairie Public Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum

203

Redwood Falls Public Utilities - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Redwood Falls Public Utilities - Residential Energy Efficiency Redwood Falls Public Utilities - Residential Energy Efficiency Rebate Program Redwood Falls Public Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus bonus for efficiency ratings above 14.5 SEER Air Source Heat Pump: $100 - $200, plus bonus for efficiency ratings above 14.5 SEER Geothermal Heat Pump: $200/ton, plus $25/ton for each 1 EER above minimum requirement Refrigerators: $25, plus $50 for recycling an old, working unit

204

Adjustable Speed Drive Part-Load Efficiency  

Energy.gov (U.S. Department of Energy (DOE))

An adjustable speed drive (ASD) is a device that controls the rotational speed of motor-driven equipment. Variable frequency drives (VFDs), the most common type of ASDs, efficiently meet varying process requirements by adjusting the frequency and voltage of the power supplied to an AC motor to enable it to operate over a wide speed range. External sensors monitor flow, liquid levels, or pressure and then transmit a signal to a controller that adjusts the frequency and speed to match process requirements.

205

Progress Energy Carolinas - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Progress Energy Carolinas - Residential Energy Efficiency Rebate Progress Energy Carolinas - Residential Energy Efficiency Rebate Program Progress Energy Carolinas - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Sealing Your Home Ventilation Heat Pumps Windows, Doors, & Skylights Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Air duct repair and replacement: Up to $190 Attic insulation upgrade and attic sealing: $500 Geothermal heat pump replacement: $300 HVAC Audit: $100 High-efficiency heat pump replacement: $300 High-efficiency central AC replacement: $300 Refrigerator/Freezer Recycling: $50/unit Provider Progress Energy Carolinas

206

Residential Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate Program Residential Energy Efficiency Rebate Program Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Commercial Lighting Lighting Water Heating Program Info State Hawaii Program Type State Rebate Program Rebate Amount CFL Bulbs: Instant Rebates Heat Pump Water Heater: $200 Refrigerators: $50 Refrigerators (with Trade-in): $125 Clothes Washers: $50 Ceiling Fans: $40 Variable Refrigerant Flow Air Conditioners: $200 Central AC Maintenance: $50 Whole House Fans: $75 Whole House Energy Monitor: 50% of the purchase price up to $100 Provider Hawaii Energy Efficiency Program As part of the Energy Solutions programs, the Hawaii Energy Efficiency

207

Alameda-Contra Costa Transit District (AC Transit) Fuel Cell...  

Energy Savers (EERE)

(AC Transit) Fuel Cell Transit Buses: Preliminary Evaluation Results Alameda-Contra Costa Transit District (AC Transit) Fuel Cell Transit Buses: Preliminary Evaluation Results This...

208

AVTA: Blink AC Level 2 Charging System Testing Results | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Blink AC Level 2 Charging System Testing Results AVTA: Blink AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing Activity carries...

209

AVTA: Schneider AC Level 2 Charging System Testing Results |...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Schneider AC Level 2 Charging System Testing Results AVTA: Schneider AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing Activity...

210

AVTA: Aerovironment AC Level 2 Charging System Testing Results...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Aerovironment AC Level 2 Charging System Testing Results AVTA: Aerovironment AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing...

211

AVTA: SPX AC Level 2 Charging System Testing Results | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

AVTA: SPX AC Level 2 Charging System Testing Results AVTA: SPX AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing Activity...

212

An Advanced simulation Code for Modeling Inductive Output Tubes  

SciTech Connect

During the Phase I program, CCR completed several major building blocks for a 3D large signal, inductive output tube (IOT) code using modern computer language and programming techniques. These included a 3D, Helmholtz, time-harmonic, field solver with a fully functional graphical user interface (GUI), automeshing and adaptivity. Other building blocks included the improved electrostatic Poisson solver with temporal boundary conditions to provide temporal fields for the time-stepping particle pusher as well as the self electric field caused by time-varying space charge. The magnetostatic field solver was also updated to solve for the self magnetic field caused by time changing current density in the output cavity gap. The goal function to optimize an IOT cavity was also formulated, and the optimization methodologies were investigated.

Thuc Bui; R. Lawrence Ives

2012-04-27T23:59:59.000Z

213

Clock-controlled generators with large period output sequences  

Science Journals Connector (OSTI)

Clock-controlled generators are a kind of pseudo-random number generators (PRNG). Recently, some clock-controlled generators based on jumping Linear Finite State Machines (LFSMs) have been proposed, such as Pomaranch and MICKEY. The period and the linear complexity of their output sequences need to be large enough to provide security against linear attacks. In this paper, a new condition for the period to reach its maximal value is presented. The condition is better than the previous one. Further, some clock-controlled generators are considered, including a new generator which uses a Feedback with Carry Shift Register (FCSR) as the control register. How to maximise the period of their output sequences is investigated.

Zhiqiang Lin

2014-01-01T23:59:59.000Z

214

Output power characteristics of the neutral xenon long laser  

SciTech Connect

Lasers which oscillate within inhomogeneously broadened gain media exhibit spectral hole burning and concomitant reduction in output power compared with equivalent homogeneously-broadened laser gain media. By increasing the cavity length, it may be possible to demonstrate at least a partial transition from an inhomogeneous laser cavity mode spectrum to a homogeneous spectrum. There are a number of high gain laser lines which are inhomogeneously-broadened transitions in electric discharges of neutral xenon. In neutral xenon lasers, as in the cases of many other gas lasers, the inhomogeneous spectral broadening mechanism arises from Doppler shifts, {Delta}{nu}{sub D}, of individual atoms in thermal motion within the electric discharge comprising the laser gain medium. Optical transitions corresponding to these noble gas atoms have natural linewidths, {Delta}{nu}{sub n}{lt}{Delta}{nu}{sub D}. Simulations of the output power characteristics of the xenon laser were carried out as a function of laser cavity parameters, including the cavity length, L. These calculations showed that when the intracavity mode spacing frequency, c/2L{lt}{Delta}{nu}{sub n}, the inhomogeneously broadened xenon mode spectrum converted to a homogeneously broadened oscillation spectrum with an increase in output power. These simulations are compared with experimental results obtained for the long laser oscillation characteristics of the (5d[5/2]{degree}{sub 2}{r_arrow}6p[3/2]{sub 1}) transition corresponding to the strong, high-gain 3.508 {mu} line in xenon.

Linford, G.J. [TRW Space and Electronics Group, Redondo Beach, CA (United States). Space and Technology Div.

1994-12-31T23:59:59.000Z

215

(Energy Efficiency)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DECLARATION DECLARATION INTERNATIONAL PARTNERSHIP FOR ENERGY EFFICIENCY COOPERATION [IPEEC] Considering: Declarations of the Gleneagles, St. Petersburg and Heiligendamm Summits, which emphasize the need for global cooperation in the field of energy efficiency. Recognizing: 1. that improving energy saving and energy efficiency is one of the quickest, greenest, and most cost-effective way to address energy security, climate change, and ensuring economic growth; 2. that a comprehensive process has been launched to enable the full, effective and sustained implementation of the UNFCCC through long-term cooperative action, now, up to and beyond 2012, in order to reach an agreed outcome and adopt a decision at the COP 15. 3. that all countries, both developed and developing, share common interests for improving their

216

ACADEMIC EFFICIENCY  

Science Journals Connector (OSTI)

...efficiency expert begins his operations in a factory his first...of learning, it is safe to say that an appalling...10) Standardized operations. (11) Written standard...what extent they are in operation. Suppose that the Carnegie...involv-ing " a gross and fundamental error. " But it would...

William Kent

1912-12-20T23:59:59.000Z

217

ACS Meeting and Chemical Exposition Draw Large Attendance  

Science Journals Connector (OSTI)

ACS Meeting and Chemical Exposition Draw Large Attendance ... Copyright © 1958 American Chemical Society ...

1958-06-01T23:59:59.000Z

218

Grand Marais PUC - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grand Marais PUC - Residential Energy Efficiency Rebate Program Grand Marais PUC - Residential Energy Efficiency Rebate Program Grand Marais PUC - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount CFLs: $2/bulb or up to 50% of cost LEDs: $10 - $15/bulb Lighting Fixtures: $15 - $20/fixture Refrigerators: $25, plus $50 for recycling an old, working unit Freezers: $25, plus $50 for recycling an old, working unit Dishwashers: $25 Clothes Washers: $50 Dehumidifiers: $65 Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings

219

Silicon Valley Power - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate Program Residential Energy Efficiency Rebate Program Silicon Valley Power - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Cooling Appliances & Electronics Commercial Lighting Lighting Water Heating Commercial Heating & Cooling Program Info State California Program Type Utility Rebate Program Rebate Amount Attic Insulation: $175 Ceiling Fan: $35 each Heat Pump Water Heater: up to $1,000 LED Bulbs: $15/bulb installed Pool Pump: $200 Refrigerator: $50 Refrigerator recycling: $35 Room AC: $25 Room AC Recycling: $25 Solar Attic Fan: $100 Whole House Fan: $200 Provider Silicon Valley Power Silicon Valley Power offers rebates to residential customers for the purchase of a variety of energy efficient products including:

220

CPS Energy - Residential Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CPS Energy - Residential Energy Efficiency Rebate Program CPS Energy - Residential Energy Efficiency Rebate Program CPS Energy - Residential Energy Efficiency Rebate Program < Back Eligibility Installer/Contractor Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Construction Design & Remodeling Sealing Your Home Ventilation Commercial Lighting Lighting Other Heat Pumps Program Info State Texas Program Type Utility Rebate Program Rebate Amount Energy Audits: Varies Central AC/Heat Pump: $110 - $225/ton, varies by efficiency rating Refrigerator Recycling: $65 Refrigerator Replacement: $35 Room A/C (window unit): $50 - $100, varies by capacity Attic/Foam Attic Insulation: $0.25/sq. ft. installed DIY-Attic Insulation: $0.15/sq.ft. installed

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

North Branch Municipal Water and Light - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

North Branch Municipal Water and Light - Residential Energy North Branch Municipal Water and Light - Residential Energy Efficiency Rebate Program North Branch Municipal Water and Light - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum

222

Reliable and Energy-Efficient Routing Protocol in Dense  

E-Print Network (OSTI)

Reliable and Energy-Efficient Routing Protocol in Dense Wireless Sensor Networks Min Chen, Taekyoung Kwon, Shiwen Mao, + Yong Yuan, Victor C.M. Leung* Department of Electrical and Computer@snu.ac.kr Department of Electrical and Computer Engineering Auburn University, 200 Broun Hall, Auburn, AL 36849

Chen, Min

223

NCPART: management of ICEMDDN output for numerical control users  

SciTech Connect

NCPART is a procedure developed by the Numerical Control Department at Bendix Kansas City Division to handle the entry to and exit from ICEMDDN, and process all of the local files output by ICEMDDN. The NCPART procedure is menu driven, and provides automatic access to ICEMDDN and any files necessary to process information with ICEM for numerical Control users. Basically, the procedure handles all of the ICEMDDN operations that involve operating system commands, and frees the NC programmer to concentrate on his/her work as a programmer.

Rossini, B.F.

1986-04-01T23:59:59.000Z

224

Waveguide submillimetre laser with a uniform output beam  

SciTech Connect

A method for producing non-Gaussian light beams with a uniform intensity profile is described. The method is based on the use of a combined waveguide quasi-optical resonator containing a generalised confocal resonator with an inhomogeneous mirror with absorbing inhomogeneities discretely located on its surface and a hollow dielectric waveguide whose size satisfies the conditions of self-imaging of a uniform field in it. The existence of quasi-homogeneous beams at the output of an optically pumped 0.1188-mm waveguide CH{sub 3}OH laser with a amplitude-stepped mirror is confirmed theoretically and experimentally. (lasers)

Volodenko, A V; Gurin, O V; Degtyarev, A V; Maslov, Vyacheslav A; Svich, V A; Topkov, A N [V.N. Karazin Kharkiv National University, Kharkiv (Ukraine)

2007-01-31T23:59:59.000Z

225

AC Ward Leonard drive systems: Revisiting the four-quadrant operation of AC machines  

Science Journals Connector (OSTI)

Abstract In this paper, the problem of controlling the speed of AC machines in four quadrants is revisited from a completely new viewpoint, based on the idea of powering an AC machine with a synchronous generator that generates a variable-voltage–variable-frequency supply. This is a natural, mathematical, but not physical, extension of the conventional Ward Leonard drive systems for DC machines to AC machines. As a result, AC drives can be regarded as generator-motor systems, which facilitate the analysis of AC drives and the introduction of other special functions because a system consisting of a generator and a motor is easier to be handled than the conventional AC drive that consists of an inverter and a motor. Control strategies, with and without a speed sensor, are proposed to implement this idea and the experimental results are presented to demonstrate the feasibility.

Qing-Chang Zhong

2013-01-01T23:59:59.000Z

226

Southwest Electric Cooperative - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Southwest Electric Cooperative - Residential Energy Efficiency Southwest Electric Cooperative - Residential Energy Efficiency Rebate Program Southwest Electric Cooperative - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Cooling Maximum Rebate Geothermal Heat Pump: 10 tons for Residential, 50 tons for Commercial Energy Audit Repairs: $500 Program Info State Missouri Program Type Utility Rebate Program Rebate Amount Geothermal Heat Pump (New Units): $750/ton Geothermal Heat Pump (Replacement Units): $200/ton Dual Fuel Heat Pump: $150/ton Room AC: $50 Energy Audit Repairs: 50% of cost Provider Southwest Electric Cooperative Southwest Electric Cooperative offers rebates to its customers that purchase energy efficient heating and air conditioning equipment . This

227

Comparison of AC drives for electric vehicles -- A report on experts` opinion survey  

SciTech Connect

It is recognized that wide applications of electric vehicles (EVs) will bring tremendous social, economical and ecological benefits. With the growing interests in electric vehicles, much effort is demanded for the development of efficient, reliable and economical AC drives` for EV propulsion purpose. Both induction motor (IM) drives and permanent magnet brushless DC motor (BDCM) drives have been applied to EVs. Switched reluctance motor (SRM) drives have been proposed as an alternative for EV propulsion. In order to assess the suitability of IM, BDCM and SRM drives for EV applications and to provide a technical support for the development and selection of future EV propulsion systems, the existing EV AC propulsion drives were compared, and a survey of experts` opinions was conducted. Comparison of the three AC drives was made on a relative and a quantitative basis using the survey questionnaires. According to the majority of the experts, induction motor drives are best suited for EV propulsion purpose, due to their low cost, high reliability, high speed, established converter and manufacturing technology, low torque ripple/noise and absence of position sensors. BDCM drives feature compactness, low weight and high efficiency and therefore provide an alternative for EV propulsion. The experts regard insulated gate bipolar transistors (IGBTs) as the most suited power semiconductor devices for AC drive converters at the present stage. 7 refs.

Chang, L. [New Brunswick Univ., Fredericton, New Brunswick (Canada). Dept. of Electrical Engineering] [New Brunswick Univ., Fredericton, New Brunswick (Canada). Dept. of Electrical Engineering

1994-08-01T23:59:59.000Z

228

Application of Infrared Thermography in Building Energy Efficiency  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Building Commissioning for Energy Efficiency and Comfort, Vol. VI-5-3 Application of Infrared Thermography in Building Energy Efficiency Yongzheng Shi Hongbing Chen Qi Xu Deying Li Zhonghua Wang Xiumu Fang...]. Infrared Technology,2002,01:34-37.(In Chinese) [6] Yangyang Wang. Research on surface temperature of building envelope measured by thermal infrared imager [J]. Hv & Ac, 2006, 02:84-88.(In Chinese) ...

Shi, Y.; Chen, H.; Xu, Q.; I, D.; Wang, Z.; Fang, X.

2006-01-01T23:59:59.000Z

229

Some Observations on Energy Efficiency and Capital Cost  

E-Print Network (OSTI)

SO~ffi OBSERVATIONS ON ENERGY EFFICIENCY AND CAPITAL COST William F. Kenney Exxon Chemical Company Florham Park, ABSTRACT The usual expectation in the process indus tries is that improved energy efficiency requires increased investment..., ACS Symposium Series ~. (3) Exxon Chemical Internal Studies. ACKNOWLEDGEMENT The author is grateful to Exxon Chemical for permission to publish this study. Particular thanks go to A. P. Durso and W. J. O'Brien of the Central Engineering...

Kenney, W. F.

1982-01-01T23:59:59.000Z

230

Photon detection efficiency of Geiger-mode avalanche photodiodes  

E-Print Network (OSTI)

The photon detection efficiencies of multi-pixel Geiger-mode avalanche photodiodes manufactured by different produ cers are estimated. A new fit method of the response spectra to low-intensity light, taking into ac count after-pulse and cross-talk effects is proposed to yield the initial number of photons. The value of photon detection efficiency is calculated using a calibrated photodetector as a reference.

Simonetta Gentile; Ekaterina Kuznetsova; Franco Meddi

2010-06-16T23:59:59.000Z

231

Safe-commutation principle for direct single-phase AC-AC converters for use in audio power  

E-Print Network (OSTI)

Safe-commutation principle for direct single-phase AC-AC converters for use in audio power-stage AC-AC audio power amplifiers. As compared with the bridge commutation with load current or source is certainly the audio power amplification. Switching-mode Class D audio power amplifiers are becoming

232

Central Hudson Gas and Electric (Electric) - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Central Hudson Gas and Electric (Electric) - Residential Energy Central Hudson Gas and Electric (Electric) - Residential Energy Efficiency Rebate Program Central Hudson Gas and Electric (Electric) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Heat Pumps Manufacturing Appliances & Electronics Water Heating Maximum Rebate Air Sealing: $600 Program Info State New York Program Type Utility Rebate Program Rebate Amount Central AC: $400 - $600, depending on efficiency Air-source Heat Pumps: $400 - $600, depending on efficiency Electronically Commutated Motor (ECM) Furnace Fans: $200 Electric Heat Pump Water Heaters: $400 Programmable Thermostats: $25

233

NV Energy (Southern Nevada) - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NV Energy (Southern Nevada) - Residential Energy Efficiency Rebate NV Energy (Southern Nevada) - Residential Energy Efficiency Rebate Program NV Energy (Southern Nevada) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Program Info State Nevada Program Type Utility Rebate Program Rebate Amount Refrigerator/freezer Recycling: $50 Air Conditioners: Up to $1000 Variable Speed Pool Pump: $200 '''Pool Pump and duct system rebates are temporarily suspended. Contact NV Energy for additional information on funding and program availability.''' NV Energy offers rebates for the installation of high efficiency A/C units, air source heat pumps, and pool pumps for residential customers in southern

234

Lumbee River EMC - Residential and Commercial Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lumbee River EMC - Residential and Commercial Energy Efficiency Lumbee River EMC - Residential and Commercial Energy Efficiency Program Lumbee River EMC - Residential and Commercial Energy Efficiency Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State North Carolina Program Type Utility Rebate Program Rebate Amount Programmable Thermostat: $15 Central AC: $25 - $50 Heat Pump: $60 - $195 Geothermal Heat Pump: $350 Water Heaters: $45 - $75 Heat Pump Water Heater: $425 Refrigerator/Freezer Recycling: $50 - $75 Provider Lumbee River Electric Membership Corporation Lumbee River EMC (LREMC) offers rebates to its residential customers who purchase and install qualified energy efficient products or services.

235

National Grid (Electric) - Large Commercial Energy Efficiency Incentive  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

National Grid (Electric) - Large Commercial Energy Efficiency National Grid (Electric) - Large Commercial Energy Efficiency Incentive Programs National Grid (Electric) - Large Commercial Energy Efficiency Incentive Programs < Back Eligibility Commercial Industrial Institutional Local Government Multi-Family Residential Retail Supplier Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Construction Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Custom Incentives: 50% of engineering studies and total costs until project reaches a 1.5 year simple payback. Program Info State Rhode Island Program Type Utility Rebate Program Rebate Amount Schools and New Buildings Custom Incentives: 75% of additional cost for efficiency upgrades AC/Heat Pumps: $30 - $125/ton

236

JEA - Commercial Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

JEA - Commercial Energy Efficiency Rebate Program JEA - Commercial Energy Efficiency Rebate Program JEA - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Other Heat Pumps Heating Commercial Lighting Lighting Insulation Water Heating Maximum Rebate Custom: Rebates capped at 50% of cost with a 2.0 year payback General/Custom: $300,000 per customer per program year Program Info State Florida Program Type Utility Rebate Program Rebate Amount Chillers: $5/ton (additional rebates available for units that exceed minimum efficiency requirement) Three Phase AC: $25 - $40/ton Three Phase Heat Pump: $20 - $30/ton

237

Denton Municipal Electric - GreenSense Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Denton Municipal Electric - GreenSense Energy Efficiency Rebate Denton Municipal Electric - GreenSense Energy Efficiency Rebate Program Denton Municipal Electric - GreenSense Energy Efficiency Rebate Program < Back Eligibility Commercial Construction Installer/Contractor Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Heat Pumps Windows, Doors, & Skylights Maximum Rebate Solar Screens: $200 Energy Efficient Windows: $500 Programmable Thermostat: $50 Attic Insulation (Retrofit): $400 Attic Insulation (New Construction): $400 Program Info State Texas Program Type Utility Rebate Program Rebate Amount Central AC: $600/unit Central Heat Pumps: $700/unit Geothermal Heat Pumps: $700/unit Attic Reflective Radiant Barrier: $200 - $300

238

Method and system for managing an electrical output of a turbogenerator  

DOE Patents (OSTI)

The system and method manages an electrical output of a turbogenerator in accordance with multiple modes. In a first mode, a direct current (DC) bus receives power from a turbogenerator output via a rectifier where turbogenerator revolutions per unit time (e.g., revolutions per minute (RPM)) or an electrical output level of a turbogenerator output meet or exceed a minimum threshold. In a second mode, if the turbogenerator revolutions per unit time or electrical output level of a turbogenerator output are less than the minimum threshold, the electric drive motor or a generator mechanically powered by the engine provides electrical energy to the direct current bus.

Stahlhut, Ronnie Dean (Bettendorf, IA); Vuk, Carl Thomas (Denver, IA)

2010-08-24T23:59:59.000Z

239

ACS calibration pipeline testing: basic image reduction  

E-Print Network (OSTI)

Hack, Colin Cox Space Telescope Science Institute 28 May 1999 ABSTRACT This report describes the basic. For a detailed description of CALACS, see ACS Instrument Science Report 99-03 by Hack. This report describes

Sirianni, Marco

240

ACS workshop in India proposes eight projects  

Science Journals Connector (OSTI)

ACS workshop in India proposes eight projects ... • Investigate the solid-state chemistry of processes and materials needed for using solar energy to split water and for transporting and storing the resulting hydrogen for use as a fuel. ...

1980-03-31T23:59:59.000Z

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Study on optimization model of energy collection efficiency and its power generation benefit evaluation of landfill gas  

Science Journals Connector (OSTI)

An optimization model for joint biogas energy collection efficiency that targets the prediction model for landfill gas output dynamics and the optimization model for gas well output has been established. The model was used to comprehensively analyze and evaluate the collection efficiency of a landfill gas well together with the long-term monitoring the gas output of the gas well within Chenjiachong Landfill. The collection efficiency increased by more than 50% than the original collection of landfill biogas and the power generation efficiency increased more than two times after the reservoir area of the landfill was optimized and regulated.

Xue Qiang

2013-01-01T23:59:59.000Z

242

Inflation uncertainty, growth uncertainty, oil prices, and output growth in the UK  

Science Journals Connector (OSTI)

This study examines the transmission and response of inflation uncertainty and output uncertainty on inflation and output growth in the UK using a bi-variate EGARCH model. Results suggest that inflation uncertain...

Ramprasad Bhar; Girijasankar Mallik

2013-12-01T23:59:59.000Z

243

Compilation and Application of Japanese Inventories for Energy Consumption and Air Pollutant Emissions Using Input?Output Tables  

Science Journals Connector (OSTI)

Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan ... Next, for each of the 400 sectors (the 399 sectors of the consolidated Input?Output Table plus the “consumption expenditure of households” sector, which is one of the final demand sectors), various statistics and source materials were used to estimate gross consumptions, expressed as a physical amount for each sector, of 6 coal-based fuels, 12 petroleum-based fuels, 3 natural gas-based fuels, and 5 other fuels. ... LPG. LPG for automobile and household use is more expensive than that used by industry, because of its higher tax rate and less efficient mode of supply. ...

Keisuke Nansai; Yuichi Moriguchi; Susumu Tohno

2003-04-04T23:59:59.000Z

244

Buildings Energy Data Book: 7.4 Efficiency Standards for Commercial HVAC  

Buildings Energy Data Book (EERE)

3 3 Efficiency Standards for Commercial Air Conditioners and Heat Pumps (1) Type Cooling Capacity (Btu/hr) Category (2) Efficiency Level Small commercial package air conditioning <65,000 AC SEER = 13.0 and heating equipment (air-cooled, HP SEER = 13.0 three-phase) Single package vertical air conditioners and <65,000 AC EER = 9.0 single package vertical heat pumps, HP EER = 9.0, COP = 3.0 single-phase and three phase Single package vertical air conditioners and ≄65,000 and <135,000 AC EER = 8.9 single package vertical heat pumps HP EER = 8.9, COP = 3.0 Single package vertical air conditioners and ≄135,000 and <240,000 AC EER = 8.6 single package vertical heat pumps HP EER = 8.6, COP = 2.9 Small commercial package air-conditioning

245

Energy Efficiency Analysis of MISO-OFDM Communication Systems Considering Power and Capacity Constraints  

E-Print Network (OSTI)

Energy Efficiency Analysis of MISO-OFDM Communication Systems Considering Power and Capacity subchannel capacity threshold. Moreover, the energy efficiency of MISO-OFDM communication systems starts-input single-output (MISO) . orthogonal frequency division multiplexing (OFDM) . energy efficiency. capacity

Wang, Cheng-Xiang

246

Residential Energy Efficiency Rebates (Offered by 11 Utilities) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Construction Heating Heat Pumps Commercial Lighting Lighting Water Heating Home Weatherization Windows, Doors, & Skylights Program Info State South Dakota Program Type Utility Rebate Program Rebate Amount Ceiling Fan: $25 Clothes Washer: $50 Decorative Light String: $3.50/string (6 string limit) Dehumidifier: $10 Dishwasher: $25 Refrigerator: $50 Room A/C: $15 Central A/C: $100 Furnace with ECM: $150 Air Handler with ECM: $150 Air-Source Heat Pump: $200 - $350 Geothermal Heat Pump: $200/ton Desuperheater: $250 Heat Pump Water Heaters: $300 Provider Missouri River Energy Services Bright Energy Solutions offers energy efficiency cash incentive programs to

247

Cluster Before You Hallucinate: Approximating Node-Capacitated Network Design and Energy Efficient Routing  

E-Print Network (OSTI)

this energy usage is an important problem. Ac- cording to the US Department of Energy [1], data networks,4,6,10]. In the Energy Efficient Vertex Routing Problem (EEVRP), the input consists of an undirected multi-graph G = (VCluster Before You Hallucinate: Approximating Node-Capacitated Network Design and Energy Efficient

Treuille, Adrien

248

Evaluation of SiC MOSFETs for a High Efficiency Three-Phase Buck Rectifier  

E-Print Network (OSTI)

-voltage DC (HVDC) distribution architecture in telecom and data centers was shown to have superior efficiency and reliability compared with the traditional AC architecture [1-2]. HVDC bus is usually set as 380 Vdc or 400 Vdc a high efficiency buck rectifier used in the first stage of HVDC architecture data center power supplies

Tolbert, Leon M.

249

Quantum teleportation scheme by selecting one of multiple output ports  

E-Print Network (OSTI)

The scheme of quantum teleportation, where Bob has multiple (N) output ports and obtains the teleported state by simply selecting one of the N ports, is thoroughly studied. We consider both deterministic version and probabilistic version of the teleportation scheme aiming to teleport an unknown state of a qubit. Moreover, we consider two cases for each version: (i) the state employed for the teleportation is fixed to a maximally entangled state, and (ii) the state is also optimized as well as Alice's measurement. We analytically determine the optimal protocols for all the four cases, and show the corresponding optimal fidelity or optimal success probability. All these protocols can achieve the perfect teleportation in the asymptotic limit of $N\\to\\infty$. The entanglement properties of the teleportation scheme are also discussed.

Satoshi Ishizaka; Tohya Hiroshima

2009-04-06T23:59:59.000Z

250

A Framework to Determine the Probability Density Function for the Output Power of Wind Farms  

E-Print Network (OSTI)

A Framework to Determine the Probability Density Function for the Output Power of Wind Farms Sairaj to the power output of a wind farm while factoring in the availability of the wind turbines in the farm availability model for the wind turbines, we propose a method to determine the wind-farm power output pdf

Liberzon, Daniel

251

Linear model-based estimation of blood pressure and cardiac output for Normal and Paranoid cases  

Science Journals Connector (OSTI)

Provisioning a generic simple linear mathematical model for Paranoid and Healthy cases leading to auxiliary investigation of the neuroleptic drugs effect imposed on cardiac output (CO) and blood pressure (BP). Multi-input single output system identification ... Keywords: Blood pressure, Cardiac output, Heart rate, MISO transfer function, Stroke volume, System identification

Mohamed Abdelkader Aboamer, Ahmad Taher Azar, Khaled Wahba, Abdallah S. Mohamed

2014-11-01T23:59:59.000Z

252

Efficient error correction for speech systems using constrained re-recognition  

E-Print Network (OSTI)

Efficient error correction of recognition output is a major barrier in the adoption of speech interfaces. This thesis addresses this problem through a novel correction framework and user interface. The system uses constraints ...

Yu, Gregory T

2008-01-01T23:59:59.000Z

253

r XXXX American Chemical Society A dx.doi.org/10.1021/ac201626b |Anal. Chem. XXXX, XXX, 000000 pubs.acs.org/ac  

E-Print Network (OSTI)

proposed as a platform for miniaturized chemical sen- sor systems. However, only a few systems achieve massr XXXX American Chemical Society A dx.doi.org/10.1021/ac201626b |Anal. Chem. XXXX, XXX, 000­000 ARTICLE pubs.acs.org/ac Chemical Vapor Detection Using a Capacitive Micromachined Ultrasonic Transducer

Khuri-Yakub, Butrus T. "Pierre"

254

EP-MAC e-mail : jyoak@snu.ac.kr, sbahk@snu.ac.kr  

E-Print Network (OSTI)

EP-MAC *, e-mail : jyoak@snu.ac.kr, sbahk@snu.ac.kr Early Preamble MAC to reduce-cycled wireless sensor motes. In this paper we propose Early Preamble-MAC(EP-MAC) which enables to get enhanced performance of low energy and low latency. EP-MAC uses both early preamble and original simple preamble, so

Bahk, Saewoong

255

debussy@cs.yonsei.ac.kr, iklee@yonsei.ac.kr Affective Icons for Music Exploring  

E-Print Network (OSTI)

O debussy@cs.yonsei.ac.kr, iklee@yonsei.ac.kr Affective Icons for Music Exploring Min and colors of harmonograph curves. These curves can be used as icons for music retrieval, and we demonstrate. This approach is compatible with a standard icon-based file browser. . Introduction Since the appearance

Lee, In-Kwon

256

Marshall Municipal Utilities - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marshall Municipal Utilities - Residential Energy Efficiency Rebate Marshall Municipal Utilities - Residential Energy Efficiency Rebate Program Marshall Municipal Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Commercial Lighting Lighting Water Heating Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: $0.20/watt Holiday Light String: $3.50/string Clothes Washer: $100 Dishwasher: $50 Refrigerator/Freezer: $50 Room A/C: $25 Dehumidifier: $10 Central A/C: $100/ton Air-source Heat Pump: $150/ton Geothermal Heat Pump: $200/ton Electric Water Heater: $50; $100 (new construction or conversion)

257

Orange and Rockland Utilities (Electric) - Commercial Efficiency Programs |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Orange and Rockland Utilities (Electric) - Commercial Efficiency Orange and Rockland Utilities (Electric) - Commercial Efficiency Programs Orange and Rockland Utilities (Electric) - Commercial Efficiency Programs < Back Eligibility Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Prescriptive Rebates: 50% of cost Program Info Funding Source System Benefits Charge Start Date 4/1/2010 State New York Program Type Utility Rebate Program Rebate Amount Small Business Lighten Up Energy Savings Evaluation and CFLs: Free A/C A/C > 65 kBTU/h: $35/ton (11.5 EER); $55 (12 EER) Heat Pumps 14 SEER or 11.5 EER: $50-$65/ton

258

Commercial Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Energy Efficiency Rebate Program Commercial Energy Efficiency Rebate Program Commercial Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Appliances & Electronics Commercial Weatherization Manufacturing Commercial Lighting Lighting Home Weatherization Insulation Design & Remodeling Water Heating Windows, Doors, & Skylights Program Info State Hawaii Program Type State Rebate Program Rebate Amount Air Cooled Packaged/Split AC: $200/ton Variable Refrigerant Flow AC: $250 - $350/ton Water Cooled Chiller (Standard): $50/ton Water Cooled Chiller (Enhanced): $150/ton VFD Control (Air Handler): $50/HP VFD Control (Chilled/Condenser Water Pumps): $80/HP VFD Pool Pump System: $225/HP VFD Domestic Water Pump System: $3,000 plus $80/HP reduction

259

Lake Country Power - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Country Power - Residential Energy Efficiency Rebate Program Country Power - Residential Energy Efficiency Rebate Program Lake Country Power - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Geothermal Heat Pump: $400 per ton Central AC: $30 - $630 Air Source Heat Pumps: $330 - $630 Ductless Air-source Heat Pump: $300 ECM Furnace Motor: $100 Off-Peak ETS Heating System: $25/KW Cycled AC/Heat Pump: $100 Off-Peak Water Heater: $100 - $200 Heat Pump Water Heater: $200 Refrigerator/Freezer: $75 (with recycling of old appliance) CFL: $1 per bulb LED holiday lights: $3 per strand

260

Corn Belt Energy Coop - Commercial Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Corn Belt Energy Coop - Commercial Energy Efficiency Rebate Program Corn Belt Energy Coop - Commercial Energy Efficiency Rebate Program (Illinois) Corn Belt Energy Coop - Commercial Energy Efficiency Rebate Program (Illinois) < Back Eligibility Agricultural Commercial Industrial Savings Category Other Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Custom Project: $0.06 per kWh reduced or 50% of project cost, up to $50,000 Program Info State Illinois Program Type Utility Rebate Program Rebate Amount Air Cooled Unitary Packaged AC/Split Systems: $60 - $75/ton Air Source Heat Pumps: $60 - $75/ton Geothermal Heat Pumps: $60 - $75/ton Packaged Terminal Heat Pump: $50/ton Room A/C: $20 Air Economizer: $150 - $180 Night Covers: $6 Programmable Thermostat: $20 - $25

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Lodi Electric Utility - Commercial Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lodi Electric Utility - Commercial Energy Efficiency Rebate Program Lodi Electric Utility - Commercial Energy Efficiency Rebate Program Lodi Electric Utility - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Construction Design & Remodeling Sealing Your Home Ventilation Heat Pumps Commercial Lighting Lighting Manufacturing Windows, Doors, & Skylights Maximum Rebate G-1 Rebates: $250 G-1 AC/Lighting Improvement: $1,000 G-2 Rebates: $7,500 G-3 to I-1 Rebates: $25,000 Program Info State California Program Type Utility Rebate Program Rebate Amount G-1 Rebates: up to $250 G-1 AC/Lighting Improvement: 25% of cost G-2 Rebates: $0.13/kWh annual projected savings

262

Chicopee Electric Light - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Chicopee Electric Light - Residential Energy Efficiency Rebate Chicopee Electric Light - Residential Energy Efficiency Rebate Program Chicopee Electric Light - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Water Heating Maximum Rebate Insulation: $300 maximum rebate Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Clothes Washer: $50 Refrigerator: $50 Freezer: $50 Dishwasher: $25 Heat Pump Water Heater: $300 Central A/C: Up to $500 Ductless Mini-Split AC: Up to $500 Air Source Heat Pump: Up to $500 Insulation: 30% of installed cost Provider EFI Municipal Rebates Chicopee Electric Light (CEL) offers a variety of incentives for its

263

IID Energy - Residential Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate Program Residential Energy Efficiency Rebate Program IID Energy - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Windows, Doors, & Skylights Maximum Rebate Central AC/Heat Pumps (Early Retirement/Replacement): $2,500 Program Info State California Program Type Utility Rebate Program Rebate Amount Attic Insulation (in pre-1978 houses): $0.60/sq ft Attic Insulation (in post-1978 houses): $0.15/sq ft Electric Attic Fan: $50 Solar Attic Fan: $125 Refrigerator: $50/unit Room Air Conditioner: $50/unit Dual Pane Windows: $2.00/sq ft Variable Speed Pool Pumps: $200 - $350/unit Central AC/Heat Pumps: $100 - $145/unit

264

Minnesota Power - Residential Energy Efficiency Rebate Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Minnesota Power - Residential Energy Efficiency Rebate Program Minnesota Power - Residential Energy Efficiency Rebate Program Minnesota Power - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heating Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Refrigerator Recycling: $35-$50 Refrigerator: $25 Clothes Washer: $40 mail-in rebate General Lighting: In-store discounts CFLs: $2 mail-in rebate Lighting Fixtures: $15 mail-in rebate Central AC with ECM: $300 Central AC: $50 Forced Air Furnace: $200, $50 bonus with ECM Furnace Integrated ECM with CAC: $375 Replacement Multi-Speed ECM in Furnace: $100 Geothermal Heat Pump: $100 - 200/ton up to $1,500, $250 bonus with ECM

265

CPS Energy - Commercial Energy Efficiency Rebates | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CPS Energy - Commercial Energy Efficiency Rebates CPS Energy - Commercial Energy Efficiency Rebates CPS Energy - Commercial Energy Efficiency Rebates < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Home Weatherization Windows, Doors, & Skylights Maximum Rebate AC: 50% of project cost Lighting: 50% of project cost Program Info State Texas Program Type Utility Rebate Program Rebate Amount Lighting: varies widely by fixture and application Central AC/Heat Pumps: $65/ton, $150/ton Custom Programs: $0.08/kWh; $200 per peak kW Provider CPS Energy CPS Energy, San Antonio's municipal electric utility, offers energy

266

El Paso Electric Company - Commercial Efficiency Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

El Paso Electric Company - Commercial Efficiency Program El Paso Electric Company - Commercial Efficiency Program El Paso Electric Company - Commercial Efficiency Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Home Weatherization Insulation Design & Remodeling Program Info State New Mexico Program Type Utility Rebate Program Rebate Amount Lighting: Varies widely Unitary and Split AC Systems: $15 - $30/ton Packaged Terminal AC/Heat Pump: $30/ton Air-Cooled Chillers: $30/ton Water-Cooled Chillers: $20 - $40/ton Vending Controls: $160 - $200 Variable Frequency Drives: $45 - $6,000 Cool Roof: $0.15/sq. ft. Solar Screen/Film: $1/sq. ft. Custom Measures: $0.11/kWh Guest Room Energy Management System: Up to $300/room

267

East Central Energy - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

East Central Energy - Residential Energy Efficiency Rebate Program East Central Energy - Residential Energy Efficiency Rebate Program East Central Energy - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Water Heating Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount LEDs: $3/bulb (limit 3 bulbs) CFL Recycling: $0.50 per bulb Central AC: $30 - $330 Air-Source Heat Pump: $300 - $630 Heat Pump/AC Tune Up: $25 Refrigerator/Freezer (with recycling of old unit): $75 Ductless Air-Source Heat Pumps: $300 Geothermal Heat Pump: $400/ton HVAC ECM: $100 Storage Water Heating: $100 - $200 Storage Space Heating: $25/KW Provider East Central Energy

268

Austin Energy - Residential Energy Efficiency Rebate Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Austin Energy - Residential Energy Efficiency Rebate Program Austin Energy - Residential Energy Efficiency Rebate Program Austin Energy - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Sealing Your Home Ventilation Heat Pumps Appliances & Electronics Water Heating Windows, Doors, & Skylights Maximum Rebate Up to 20% of the cost of improvements, up to $1,575 Bonus incentives up to $700 Program Info State Texas Program Type Utility Rebate Program Rebate Amount Central AC/Heat Pump: $350 - $600 Package Unit AC/Heat Pump: $400 - $550 Weatherization Bonus: $250 - $500 Solar Screens/Solar Film: $1/sq. ft. Attic Insulation to R-38: varies by original R-value Radiant Barrier: $0.10/sq. ft. of accessible attic space

269

Alexandria Light and Power - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alexandria Light and Power - Residential Energy Efficiency Rebate Alexandria Light and Power - Residential Energy Efficiency Rebate Program Alexandria Light and Power - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Construction Heat Pumps Commercial Lighting Lighting Water Heating Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Clothes Washer: $50 - $75 Refrigerator: $50, with recycling of old, working model Dishwasher: $25 Dehumidifier: $10 Room Air Conditioner: $15 Heat Pump Water Heater: $300 Central A/C: $200 Mini-Split Ductless A/C: $100 ECM in New Furnace/Air Handler/Fan Coil: $150 Air-Source Heat Pump: $250 - $350 Programmable Thermostat: $25 Geothermal Heat Pump: $200/ton

270

Dakota Electric Association - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dakota Electric Association - Residential Energy Efficiency Rebate Dakota Electric Association - Residential Energy Efficiency Rebate Program Dakota Electric Association - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount CFL's: $1/bulb LED's: $3/bulb AC/Heat Pump Tune-Up: $25 Central AC/Heat Pump: $30 - $330 depending on SEER rating Air-Source Heat Pump: $330 for off peak control Ductless Air-Source Heat Pump: $300 Furnace Motor: $100 Geothermal Heat Pump: $400/ton Storage Electric Heating: $25 per kW Electric/Heat Pump Water Heater: $100 - $200 Refrigerator: $75 Freezer: $75 Provider Dakota Electric Service

271

Microsoft Word - AC Report Final LBNL format-2.docx  

NLE Websites -- All DOE Office Websites (Extended Search)

ERNEST ORLANDO LAWRENCE ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners Nihar Shah 1 , Paul Waide 2 , Amol Phadke 1 LBNL-XXXX 1 Environmental Energy Technologies Division, International Energy Studies Group, Lawrence Berkeley National Laboratory 2 Navigant Consulting, Inc. This work was funded by the Bureau of Oceans and International Environmental and Scientific Affairs, U.S. Department of State, and administered by the U.S. Department of Energy in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative through the U.S. Department of Energy under Contract No. DE-AC02-05CH11231 i Disclaimer This document was prepared as an account of work sponsored by the United States Government in

272

Revisions to Energy Efficiency Enforcement Regulations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6450-01-P 6450-01-P DEPARTMENT OF ENERGY 10 CFR Parts 430 and 431 Docket No. EERE-2010-BT-CE-0014 RIN 1904-AC23 Revisions to Energy Efficiency Enforcement Regulations AGENCY: Office of Energy Efficiency and Renewable Energy and Office of the General Counsel, Department of Energy. ACTION: Request for Information (RFI); request for comment. SUMMARY: The U.S. Department of Energy (DOE or the "Department") intends to expand and revise its existing energy efficiency enforcement regulations for certain consumer products and commercial and industrial equipment covered under the Energy Policy and Conservation Act of 1975, as amended (EPCA or the "Act"). These regulations provide for manufacturer submission of compliance statements and

273

A Tool to Prioritize Energy Efficiency Investments  

NLE Websites -- All DOE Office Websites (Extended Search)

A Tool to Prioritize Energy A Tool to Prioritize Energy Efficiency Investments Philip Farese, Rachel Gelman, and Robert Hendron National Renewable Energy Laboratory (NREL) NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Technical Report NREL/TP-6A20-54799 August 2012 Contract No. DE-AC36-08GO28308 National Renewable Energy Laboratory 15013 Denver West Parkway Golden, Colorado 80401 303-275-3000 * www.nrel.gov A Tool to Prioritize Energy Efficiency Investments Philip Farese, Rachel Gelman, and Robert Hendron National Renewable Energy Laboratory (NREL) Prepared under Task No. SA10.1072 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy

274

Groton Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Groton Utilities - Residential Energy Efficiency Rebate Program Groton Utilities - Residential Energy Efficiency Rebate Program Groton Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Low-Income Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Heat Pumps Commercial Lighting Lighting Water Heating Program Info State Connecticut Program Type Utility Rebate Program Rebate Amount Compact Fluorescent Bulbs: Free While Supplies Last Insulation: $0.50/sq ft Heat Pump Water Heater: Up to $500 HVAC Controls: $250/unit Single Package/Split System Unitary AC: $250/ton Air-Source Heat Pump: $250/ton Water-Source Heat Pump: $150/ton Home Energy Savings Program: Free for Electric Customers

275

Vehicle Technologies Office: Fact #482: August 13, 2007 Refinery Output by  

NLE Websites -- All DOE Office Websites (Extended Search)

2: August 13, 2: August 13, 2007 Refinery Output by World Region to someone by E-mail Share Vehicle Technologies Office: Fact #482: August 13, 2007 Refinery Output by World Region on Facebook Tweet about Vehicle Technologies Office: Fact #482: August 13, 2007 Refinery Output by World Region on Twitter Bookmark Vehicle Technologies Office: Fact #482: August 13, 2007 Refinery Output by World Region on Google Bookmark Vehicle Technologies Office: Fact #482: August 13, 2007 Refinery Output by World Region on Delicious Rank Vehicle Technologies Office: Fact #482: August 13, 2007 Refinery Output by World Region on Digg Find More places to share Vehicle Technologies Office: Fact #482: August 13, 2007 Refinery Output by World Region on AddThis.com... Fact #482: August 13, 2007

276

Refines Efficiency Improvement  

SciTech Connect

Refinery processes that convert heavy oils to lighter distillate fuels require heating for distillation, hydrogen addition or carbon rejection (coking). Efficiency is limited by the formation of insoluble carbon-rich coke deposits. Heat exchangers and other refinery units must be shut down for mechanical coke removal, resulting in a significant loss of output and revenue. When a residuum is heated above the temperature at which pyrolysis occurs (340 C, 650 F), there is typically an induction period before coke formation begins (Magaril and Aksenova 1968, Wiehe 1993). To avoid fouling, refiners often stop heating a residuum before coke formation begins, using arbitrary criteria. In many cases, this heating is stopped sooner than need be, resulting in less than maximum product yield. Western Research Institute (WRI) has developed innovative Coking Index concepts (patent pending) which can be used for process control by refiners to heat residua to the threshold, but not beyond the point at which coke formation begins when petroleum residua materials are heated at pyrolysis temperatures (Schabron et al. 2001). The development of this universal predictor solves a long standing problem in petroleum refining. These Coking Indexes have great potential value in improving the efficiency of distillation processes. The Coking Indexes were found to apply to residua in a universal manner, and the theoretical basis for the indexes has been established (Schabron et al. 2001a, 2001b, 2001c). For the first time, a few simple measurements indicates how close undesired coke formation is on the coke formation induction time line. The Coking Indexes can lead to new process controls that can improve refinery distillation efficiency by several percentage points. Petroleum residua consist of an ordered continuum of solvated polar materials usually referred to as asphaltenes dispersed in a lower polarity solvent phase held together by intermediate polarity materials usually referred to as resins. The Coking Indexes focus on the amount of these intermediate polarity species since coke formation begins when these are depleted. Currently the Coking Indexes are determined by either titration or solubility measurements which must be performed in a laboratory. In the current work, various spectral, microscopic, and thermal techniques possibly leading to on-line analysis were explored for measuring the Coking Indexes.

WRI

2002-05-15T23:59:59.000Z

277

Techniques for energy conservation in ac motor-driven systems. Final report  

SciTech Connect

Techniques for energy conservation of reducing losses in ac motor-driven systems proposed by the technical community in response to surging cost of energy are evaluated and compared. Report objectives are to provide better understanding of underlying principles and to evaluate technical and economic viability of these techniques for various applications. An important aspect considered is the impact on electric utility system in terms of harmonics, power factor of operation, and Electro-Magnetic Interference (EMI). The techniques evaluated are: NASA Power Factor Controller, a simple device for reducing power losses in lightly loaded ac motors; wanlass motor modification, a scheme of reconnecting motor windings with capacitors in series, with the intention of improving the motor efficiencies under all loading conditions; conventional variable frequency solid-state inverters which can control the speed of ac motors by producing adjustable frequency ac voltage, with a significant potential for energy conservation in pumps and air-handling systems; and other variable frequency drives and schemes including cycloconverters, slip-recovery scheme, Exxon Alternating Current Synthesizer, Venturini conversion technique, permanent magnet synchronous motors, and a device called the Phase-Liner. The impact of rapid growth in semiconductors and magnetic materials technologies is also considered.

Mohan, N.

1981-09-01T23:59:59.000Z

278

Marshall Municipal Utilities - Commercial Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marshall Municipal Utilities - Commercial Energy Efficiency Rebate Marshall Municipal Utilities - Commercial Energy Efficiency Rebate Program Marshall Municipal Utilities - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Appliances & Electronics Construction Heating Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Custom Measures: 75% of the incremental cost of the measure Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: Varies by fixture type, wattage and application Central A/C: $100/ton Air-Source Heat Pumps: $150/ton Geothermal Heat Pumps: $200/ton Commercial Refrigeration: See Program Website

279

Cedar Falls Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate Residential Energy Efficiency Rebate Program Cedar Falls Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Cooling Appliances & Electronics Design & Remodeling Windows, Doors, & Skylights Ventilation Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Appliance Recycling: 2 rebates per residential account, per appliance type annually Ceiling Fan Light Kits: $20 per light kit; 6 per account per year Central A/C: $400 Air Source Heat Pump: $600 Attic/Ceiling Insulation: $1,000 Air Sealing/Caulking/Weather Stripping: $200 CFL: 50% of cost, up to $5 (10 per customer per year)

280

The Energy Cooperative - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Energy Cooperative - Residential Energy Efficiency Rebate The Energy Cooperative - Residential Energy Efficiency Rebate Program The Energy Cooperative - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heating Heat Pumps Appliances & Electronics Water Heating Program Info State Ohio Program Type Utility Rebate Program Rebate Amount Dual Fuel Heat Pumps: $599 Water Heater (Replacement): $100 Water Heater (New): $250 - $350 Geothermal Heat Pump: $599 Central AC: $100 Provider The Energy Cooperative The Energy Cooperative offers incentives to residential customers for the installation of dual fuel heating systems, water heaters, geothermal heat pumps and central air conditioners. Equipment must be installed in eligible

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Ames Electric Department - Residential Energy Efficiency Rebate Programs |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ames Electric Department - Residential Energy Efficiency Rebate Ames Electric Department - Residential Energy Efficiency Rebate Programs Ames Electric Department - Residential Energy Efficiency Rebate Programs < Back Eligibility Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Commercial Lighting Lighting Maximum Rebate Appliances: 50% of the equipment cost Programmable Thermostats: 3 per household Room AC: 2 per household Program Info State Iowa Program Type Utility Rebate Program Rebate Amount Energy Star New Home: $500 Energy Audit: FREE Lighting: $2 - $16 per fixture Lighting Sensors: $10 per unit Refrigerators: $25 - $100 Freezers: $50 Dishwashers: $50

282

Riverside Public Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Rebate Energy Efficiency Rebate Program Riverside Public Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Low-Income Residential Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Sealing Your Home Ventilation Heat Pumps Insulation Design & Remodeling Windows, Doors, & Skylights Maximum Rebate Maximum allowable rebate for appliances is $500 per customer, per year Central AC/Heat Pumps: $1,000 Program Info State California Program Type Utility Rebate Program Rebate Amount Whole House Program: Up to $7,000 per 12 month period Refrigerators: $100 ($200 w/recycling of old unit) Room Air Conditioner: $50 Dishwasher: $50 Clothes Washer: $75 - $155

283

Black Hills Energy (Electric) - Residential Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric) - Residential Energy Efficiency Electric) - Residential Energy Efficiency Program Black Hills Energy (Electric) - Residential Energy Efficiency Program < Back Eligibility Construction Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Appliances & Electronics Sealing Your Home Ventilation Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Attic Insulation: $500 Wall Insulation: $500 Air Sealing: $300 Program Info Start Date 7/1/2010 Expiration Date 12/31/2013 State Colorado Program Type Utility Rebate Program Rebate Amount Energy Star New Home: Contact Black Hills Energy Air-Source Heat Pump Split System: $400 Central A/C: $500-$700 Ground Source Heat Pumps: $1,200

284

Ocala Utility Services - Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ocala Utility Services - Energy Efficiency Rebate Program Ocala Utility Services - Energy Efficiency Rebate Program Ocala Utility Services - Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Water Heating Maximum Rebate Residential Insulation: $300 Commercial Insulation: $1,000 Program Info State Florida Program Type Utility Rebate Program Rebate Amount Central AC/Heat Pump: $250 Refrigerators: $75 Freezer: $75 Programmable Thermostats: $25 Clothes Washer: $100 Dishwasher: $75 Residential Insulation: $0.10 per square foot Commercial Insulation: $0.10 per square foot Self-installed Insulation: $75 Provider Ocala Utility Services Electric and Telecommunications

285

Loveland Water and Power - Commercial and Industrial Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial and Industrial Energy Commercial and Industrial Energy Efficiency Rebate Program Loveland Water and Power - Commercial and Industrial Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Cooling Manufacturing Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Windows, Doors, & Skylights Maximum Rebate $50,000 per year Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Lighting: See Program Website Cooling Efficiency Room AC: $50 - $110/ton, plus $3.50 - $5.00 for each 0.1 above minimum SEER, IEER, or EER Economizer: $250 Motion Sensor Controls: $75 Building Envelope Window Replacement: $1.50/sq. ft.

286

Pacific Power - Residential Energy Efficiency Rebate Programs | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pacific Power - Residential Energy Efficiency Rebate Programs Pacific Power - Residential Energy Efficiency Rebate Programs Pacific Power - Residential Energy Efficiency Rebate Programs < Back Eligibility Construction Installer/Contractor Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Commercial Lighting Lighting Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount Clothes Washers: $50-$75 Refrigerators: $20 Refrigerator Recycling: $35 Dishwashers: $20 Water Heater: $40 CFL Lamps: Retailer discounts Lighting Fixtures: $20 Ceiling Fans: $20 Room Air Conditioner: $30 Evaporative Coolers: $50-$150 Central A/C Equipment: $100 (homeowner); $25 (contractor)

287

EWEB - New Facilities Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EWEB - New Facilities Energy Efficiency Rebate Program EWEB - New Facilities Energy Efficiency Rebate Program EWEB - New Facilities Energy Efficiency Rebate Program < Back Eligibility Commercial Commercial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Heat Pumps Heating Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Western Premium Economizer: $500 Program Info State Oregon Program Type Utility Rebate Program Utility Rebate Program Rebate Amount AC (gas heating): $15 - $30 per ton Heat Pumps: $40 - $80 per ton Western Premium Economizer: $125 per ton Programmable Thermostat: $25 - $50, depending on HVAC type Occupancy Sensors/Controls: $30 - $65 High Performance T8: $1 - $8

288

South River EMC - Energy Efficient Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

South River EMC - Energy Efficient Rebate Program South River EMC - Energy Efficient Rebate Program South River EMC - Energy Efficient Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Construction Design & Remodeling Ventilation Heat Pumps Commercial Lighting Lighting Program Info State North Carolina Program Type Utility Rebate Program Rebate Amount Clothes Washers: $25 Refrigerators: $25 Freezers: $25 Dishwashers: $25 Programmable Thermostats: $25 Heat Pumps: $200 Geothermal Heat Pumps: $300 Central A/C: $25 - $50 2nd Freezer/Refrigerator Recycling: $50 CFLs, Cold Cathode, LEDs: $1/bulb Lighting System: $0.30/watt saved Weatherization: $100 - $300

289

Burbank Water and Power - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate Residential Energy Efficiency Rebate Program Burbank Water and Power - Residential Energy Efficiency Rebate Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Sealing Your Home Design & Remodeling Windows, Doors, & Skylights Program Info State California Program Type Utility Rebate Program Rebate Amount Products purchased from a Burbank retailer are typically awarded higher rebates than those purchased outside Burbank. Inside Burbank: Ceiling Fans: $25 (maximum three) Clothes Washer: $50 Dishwasher: $35 Refrigerator/Freezer: $75 Room A/C: $35 Low E Windows/Doors: $2.00/sq ft

290

Ameren Missouri (Electric) - Residential Energy Efficiency Rebate Programs  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ameren Missouri (Electric) - Residential Energy Efficiency Rebate Ameren Missouri (Electric) - Residential Energy Efficiency Rebate Programs Ameren Missouri (Electric) - Residential Energy Efficiency Rebate Programs < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate Refrigerator/Freezer Recycling: 3 units Program Info State Missouri Program Type Utility Rebate Program Rebate Amount CFL's: In-store discounts, Online Store Refrigerator/Freezer Recycling: $50 Air Source Heat Pump: $300 - $650 Central AC: $150 - $425 Electronically Commutated Blower Motor: $50 - $100 Geothermal Heat Pump: $600 Diagnostic Tune-Up: $75 Programmable Thermostat: $25 Electric Storage Water Heater: $25

291

Eau Claire Energy Cooperative - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Eau Claire Energy Cooperative - Residential Energy Efficiency Eau Claire Energy Cooperative - Residential Energy Efficiency Rebate Program Eau Claire Energy Cooperative - Residential Energy Efficiency Rebate Program < Back Eligibility Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Manufacturing Heat Pumps Commercial Lighting Lighting Water Heating Program Info State Wisconsin Program Type Utility Rebate Program Rebate Amount Clothes washer: $25 Dishwashers: $25 Refrigerators: $25 Room Air Conditioner: $25 Dehumidifier: $25 Refrigerator/Freezer/Room AC Recycling: $25 Central Air Conditioner/Mini Split: $40 - $80/Ton Air Source Heat Pump/Mini-Split Heat Pumps: $150/Ton Package Terminal Heat Pump: $150/Ton Geothermal Heat Pump: $300/Ton

292

Waverly Light and Power - Residential Energy Efficiency Rebates |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Rebates Energy Efficiency Rebates Waverly Light and Power - Residential Energy Efficiency Rebates < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Water Heating Maximum Rebate Appliance Recycling: $150 Program Info State Iowa Program Type Utility Rebate Program Rebate Amount Energy Star New Home: $1,300 Heat Pump Water Heater: $500 LED Lighting: 50% of cost, up to $200 Central AC: $150 Air-Source Heat Pump: $150 Geothermal Heat Pump: $450 Clothes Washer: $75 Refrigerator: $50 Appliance Recycling: $75 Provider Waverly Light and Power Waverly Light and Power (WL&P) offers rebates for the purchase and

293

Princeton Plasma Physics Lab - AC power  

NLE Websites -- All DOE Office Websites (Extended Search)

ac-power The electricity that runs the ac-power The electricity that runs the Laboratory's experiments and facilities. "AC" stands for the alternating current that comes from large power stations. The term compares with "DC," for "direct current," which comes from sources like batteries. en Offshore Wind and Vehicle to Grid Power http://www.pppl.gov/events/offshore-wind-and-vehicle-grid-power

Professor Willett Kempton, of the University of Delaware, presents "Offshore Wind and Vehicle to Grid Power" as part of the Andlinger Center's 2013-2014 Highlight Seminar Series.

294

Energy efficient data centers  

E-Print Network (OSTI)

wit h energy efficiency Improving Best Practices Linkwit h energy efficiency Improving Best Practices Linkwit h energy efficiency Improving Best Practices Link

Tschudi, William; Xu, Tengfang; Sartor, Dale; Koomey, Jon; Nordman, Bruce; Sezgen, Osman

2004-01-01T23:59:59.000Z

295

www.mmu.ac.uk/careers Careers & Employability Service  

E-Print Network (OSTI)

.mmu.ac.uk/careers Identifying courses · www.prospects.ac.uk/search_courses.htm · www.jobs.ac.uk · www.Findamasters.com · www.mmu.ac.uk/careers PG Professional/Vocational courses: Courses to allow you to enter certain professions Courses involve lectures for the first two terms then a research project for the final term (often finishing after

296

AC H I E V I NG  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

AC AC H I E V I NG The Department's strategic plan flow is highlighted in the cascade below beginning with the mission statement which flows to the strategic themes. The strategic themes connect to the broader strategic goals and are linked to the annual performance goals in the performance budget through the multi-year program plans. The multi-year program plans allow DOE to strategize over a five-year period how each program will implement the strategic goals of the Department. Annual performance goals and assessment of performance against prior-year

297

Energy Efficiency Governance Energy Efficiency  

E-Print Network (OSTI)

countries through collective response to physical disruptions in oil supply and to advise member countries on sound energy policy. The IEA carries out a comprehensive programme of energy co-operation among 28 advanced economies, each of which is obliged to hold oil stocks equivalent to 90 days of its net imports. The Agency aims to: n Secure member countries ’ access to reliable and ample supplies of all forms of energy; in particular, through maintaining effective emergency response capabilities in case of oil supply disruptions. n Promote sustainable energy policies that spur economic growth and environmental protection in a global context – particularly in terms of reducing greenhouse-gas emissions that contribute to climate change. n Improve transparency of international markets through collection and analysis of energy data. n Support global collaboration on energy technology to secure future energy supplies and mitigate their environmental impact, including through improved energy efficiency and development and deployment of low-carbon technologies. © OECD/IEA, 2010 International Energy Agency 9 rue de la Fédération

unknown authors

298

Efficiency of static core turn-off in a system-on-a-chip with variation  

DOE Patents (OSTI)

A processor-implemented method for improving efficiency of a static core turn-off in a multi-core processor with variation, the method comprising: conducting via a simulation a turn-off analysis of the multi-core processor at the multi-core processor's design stage, wherein the turn-off analysis of the multi-core processor at the multi-core processor's design stage includes a first output corresponding to a first multi-core processor core to turn off; conducting a turn-off analysis of the multi-core processor at the multi-core processor's testing stage, wherein the turn-off analysis of the multi-core processor at the multi-core processor's testing stage includes a second output corresponding to a second multi-core processor core to turn off; comparing the first output and the second output to determine if the first output is referring to the same core to turn off as the second output; outputting a third output corresponding to the first multi-core processor core if the first output and the second output are both referring to the same core to turn off.

Cher, Chen-Yong; Coteus, Paul W; Gara, Alan; Kursun, Eren; Paulsen, David P; Schuelke, Brian A; Sheets, II, John E; Tian, Shurong

2013-10-29T23:59:59.000Z

299

NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC.  

E-Print Network (OSTI)

& Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Contract No. DE-AC36-08GO28308.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance

300

PDSF Job Efficiency  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimization Running Jobs Efficiently Running Jobs Efficiently Job Efficiency A job's efficiency is the ratio of its CPU time to the actual time it took to run, i.e., cputime ...

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

SEPTEMBER 2009 ENERGY EFFICIENCY &  

E-Print Network (OSTI)

SEPTEMBER 2009 GUIDE TO ENERGY EFFICIENCY & RENEWABLE ENERGY FINANCING DISTRICTS FOR LOCAL Assessment Districts) DEER Database for Energy Efficient Resources DSIRE Database of State Incentives for Renewables & Efficiency EECBG Energy Efficiency and Conservation Block Grants EIM Energy Improvement Mortgage

Kammen, Daniel M.

302

Stirling converters for space dynamic power concepts with 2 to 130 W{sub e} output  

SciTech Connect

Three innovative Stirling converter concepts are described. Two concepts are based on Pluto Fast Flyby (PFF) mission requirements, where two General Purpose Heat Source (GPHS) modules provide the thermal input. The first concept (PFF2) considers a power system with two opposed Stirling converters; the second concept (PFF4) considers four opposed Stirling converters. For both concepts the Stirling converters are designed to vary their power production capability to compensate for the failure of one Stirling converter. While the net thermal efficiency of PFF4 is a few percentage points lower than PFF2, the total Stirling converter mass of PFF4 is half that for PFF2. The third concept (ITTI) is designed to supply 2 watts of power for weather stations on the Martian surface. The predicted thermal performance of the ITTI is low compared to PFF2 and PFF4, yet the ITTI concept offers significant advantages compared to currently available power systems at the 2-watt power level. All three concepts are based on long-life technology demonstrated by an 11-watt output Stirling generator that as of March 1995 has accumulated over 15,000 operating hours without maintenance.

Ross, B.A. [Stirling Technology Co., Richland, WA (United States)

1995-12-31T23:59:59.000Z

303

Efficiency of some heat engines at maximum?power conditions  

Science Journals Connector (OSTI)

In the present paper a simple model is presented for a heat engine where the power output is limited by the rate of heat supply (and/or heat release). The model leads to a variety of results. Some of them are established laws such as the Carnot law the Curzon–Ahlborn efficiency and the Castańs efficiency. Other results are new and are related to phenomena as different as geothermal energy conversion and the Penfield paradox of electric circuits.

Alexis De Vos

1985-01-01T23:59:59.000Z

304

WWW.LANCASTER.AC.UK/SCI-TECH SCIENCE AND TECHNOLOGY  

E-Print Network (OSTI)

, a combined visual and physical output device - Dr Jason Alexander, School of Computing and Communications #12

Diggle, Peter J.

305

Queue Prediction: an efficient scheduler for fast ATM cell transmission  

E-Print Network (OSTI)

Queue Prediction: an efficient scheduler for fast ATM cell transmission Peter Fenwick Department, if not impossible within the time constraints of fast ATM transmission (622 Mbps or higher). This paper presents a solution to this problem. By scheduling in advance the transmissions from queues it allows all output

Fenwick, Peter

306

www.jubileecentre.ac.uk JAMES ARTHUR  

E-Print Network (OSTI)

www.jubileecentre.ac.uk JAMES ARTHUR KRISTJÁN KRISTJÁNSSON HYWEL THOMAS MICHAEL HOLDSWORTH LUCA BADINI CONFALONIERI TIAN QIU FOREWORD BY PROFESSOR ADRIAN EVANS VIRTUOUS CHARACTERFOR THE PRACTICE OF LAW by Professor James Arthur. Based at the University of Birmingham, it has a dedicated team of 30 academics from

Birmingham, University of

307

ACS Installation During SM3B Introduction  

E-Print Network (OSTI)

ACS Installation During SM3B Introduction: · Installed during SM3B in March 2002 · Powerful 3rd · Over-voltage Protection kit installed · Optical Control Electronics connected · New Outer Blanket Layer, and coronagraph ­ Solar Blind Channel (SBC) : HST's most sensitive ultraviolet photon-counting detector 115-180 nm

Sirianni, Marco

308

Appendix AC Exceptions to Delegated Purchasing Authority  

E-Print Network (OSTI)

Appendix AC Exceptions to Delegated Purchasing Authority Delegated purchasing authority for professions exempted by 18-4-132, MCA The following services are exempt from Purchasing Procedures per Montana provider - Expert witness hired for use in litigation, Hearings Officer hired in rulemaking and contested

Dyer, Bill

309

Coupling efficiency analysis of hydraulic pressure energy harvesters  

Science Journals Connector (OSTI)

The acoustic pressure within hydraulic systems referred to as pressure ripple is a high intensity energy source that can be utilized for powering sensor networks. A section of such a system can be modeled as a one dimensional waveguide where the intensity can reach up to 1000 mW/cm2 from a 300 kPa pressure ripple (peak-to-peak acoustic pressure) within a hydraulic system. Hydraulic pressure energy harvesters (HPEH) are devices designed to convert the pressure ripple into electrical energy thereby enabling wireless sensor nodes. HPEH couple the dynamic fluid pressure to a piezoelectric stack which is connected to a harvester circuit to optimize power output. A key aspect of the HPEH design is the fluid-mechanical coupling of the pressure ripple to the stack for maximizing the energy extracted. The efficiency of HPEH device and harvester circuit potential power output can be determined using the volume velocity of the pressure ripple the coupling efficiency of the HPEH and the conversion efficiency of the piezoelectric stack. In this work the coupling efficiency and the power output efficiency of currently developed HPEH devices will be analyzed and compared to modeled efficiency of such devices.

Kenneth Cunefare; Alper Erturk

2013-01-01T23:59:59.000Z

310

Combining frequency and time domain approaches to systems with multiple spike train input and output  

E-Print Network (OSTI)

between neuronal spike trains. Prog Biophys Mol Biol Vapnikto systems with multiple spike train input and output D. R.Keywords Multiple spike trains · Neural coding · Maximum

Brillinger, D. R.; Lindsay, K. A.; Rosenberg, J. R.

2009-01-01T23:59:59.000Z

311

On using transputers to design the header and output processors for the PSi architecture  

E-Print Network (OSTI)

the complexity associatecl with general soft ware. From Upper Layer Needer Processor From Lower Leyei' Input Bus Concoction Processor Connection Processor 256 CP's Output Bus To Upper Layer Output Processor To Lower Layer Fig. 2. d. Block... yer From Lower Layer T2 T3 To Input Bus of CP's From Output Bus of CF's From Output Bus of Cfes Fig, 4. 1. e. Block diagram of Design I transputers has its own private memory. Tl acts as the header processor. Two of its serial links...

Manickam, Muralidhar

2012-06-07T23:59:59.000Z

312

A CSP Timed Input-Output Relation and a Strategy for Mechanised Conformance Verification  

Science Journals Connector (OSTI)

Here we propose a timed input-output conformance relation (named CSPTIO) based on the process algebra CSP. In contrast to other relations, CSPTIO...

Gustavo Carvalho; Augusto Sampaio…

2013-01-01T23:59:59.000Z

313

FORMALIZATION OF INPUT AND OUTPUT IN MODERN OPERATING SYSTEMS: THE HADLEY MODEL.  

E-Print Network (OSTI)

??We present the Hadley model, a formal descriptive model of input and output for modern computer operating systems. Our model is intentionally inspired by the… (more)

Gerber, Matthew

2005-01-01T23:59:59.000Z

314

Cavity dumping versus stationary output coupling in repetitively Q-switched solid-state lasers  

Science Journals Connector (OSTI)

A comparative theoretical analysis of continuously pumped actively Q-switched solid-state lasers differing in output coupling methods (cavity dumping versus a partially transmitting...

Grishin, Mikhail

2011-01-01T23:59:59.000Z

315

Method for assessing in-service motor efficiency and in-service motor/load efficiency  

DOE Patents (OSTI)

A method and apparatus for assessing the efficiency of an in-service motor. The operating characteristics of the in-service motor are remotely measured. The operating characteristics are then applied to an equivalent circuit for electrical motors. Finally the equivalent circuit is evaluated to determine the performance characteristics of said in-service motor. Based upon the evaluation an individual is able to determine the rotor speed, power output, efficiency, and toque of the in-service motor. Additionally, an individual is able to confirm the calculations by comparing measured values with values obtained as a result of the motor equivalent circuit evaluation.

Kueck, John D. (Oak Ridge, TN); Otaduy, Pedro J. (Oak Ridge, TN)

1997-01-01T23:59:59.000Z

316

Magnetostrictive materials and method for improving AC characteristics in same  

DOE Patents (OSTI)

The present invention provides Terfenol-D alloys ("doped" Terfenol) having optimized performances under the condition of time-dependent magnetic fields. In one embodiment, performance is optimized by lowering the conductivity of Terfenol, thereby improving the frequency response. This can be achieved through addition of Group III or IV elements, such as Si and Al. Addition of these types of elements provides scattering sites for conduction electrons, thereby increasing resistivity by 125% which leads to an average increase in penetration depth of 80% at 1 kHz and an increase in energy conversion efficiency of 55%. The permeability of doped Terfenol remains constant over a wider frequency range as compared with undoped Terfenol. These results demonstrate that adding impurities, such as Si and Al, are effective in improving the ac characteristics of Terfenol. A magnetoelastic Gruneisen parameter, .gamma..sub.me, has also been derived from the thermodynamic equations of state, and provides another means by which to characterize the coupling efficiency in magnetostrictive materials on a more fundamental basis.

Pulvirenti, Patricia P. (Chicago, IL); Jiles, David C. (Ames, IA)

2001-08-14T23:59:59.000Z

317

Fort Collins Utilities - Commercial and Industrial Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial and Industrial Energy Commercial and Industrial Energy Efficiency Rebate Program Fort Collins Utilities - Commercial and Industrial Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Other Sealing Your Home Ventilation Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Insulation Windows, Doors, & Skylights Maximum Rebate Building Tune Up: $50,000 Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Roof Top A/C: $100 - $150, plus $5 for each 0.1 SEER or IEER above minimum requirement Variable Frequency Drives: $85 - $120/HP Packaged Terminal A/C: $50, plus $5 for each 0.1 EER above minimum

318

Minnesota Valley Electric Cooperative - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Minnesota Valley Electric Cooperative - Residential Energy Minnesota Valley Electric Cooperative - Residential Energy Efficiency Rebate Program Minnesota Valley Electric Cooperative - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Appliances & Electronics Heat Pumps Maximum Rebate Ground-Source Heat Pump: 5 ton maximum Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Clothes Washer: $25 Freezer/Refrigerator: $25 Dishwasher: $25 Air-Source Heat Pump: $500 Ground-Source Heat Pump: $200 per ton Electric Resistant Heating Products: $10 per kW Mini-Split Heat Pumps: $75 Central A/C or Heat Pump Tune-Up: $25 Provider Minnesota Valley Electric Cooperative Minnesota Valley Electric Cooperative (MVEC) offers financial incentives to

319

Method and system for an on-chip AC self-test controller  

DOE Patents (OSTI)

A method and system for performing AC self-test on an integrated circuit that includes a system clock for use during normal operation are provided. The method includes applying a long data capture pulse to a first test register in response to the system clock, applying an at speed data launch pulse to the first test register in response to the system clock, inputting the data from the first register to a logic path in response to applying the at speed data launch pulse to the first test register, applying an at speed data capture pulse to a second test register in response to the system clock, inputting the logic path output to the second test register in response to applying the at speed data capture pulse to the second test register, and applying a long data launch pulse to the second test register in response to the system clock.

Flanagan, John D. (Rhinebeck, NY); Herring, Jay R. (Poughkeepsie, NY); Lo, Tin-Chee (Fishkill, NY)

2008-09-30T23:59:59.000Z

320

Independence Power and Light - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Independence Power and Light - Residential Energy Efficiency Rebate Independence Power and Light - Residential Energy Efficiency Rebate Program Independence Power and Light - Residential Energy Efficiency Rebate Program < Back Eligibility Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State Missouri Program Type Utility Rebate Program Rebate Amount Central A/C: $109 - $384 Heat Pumps: $259 - $701 Heat Pumps Water Heaters: $300 Provider Independence Power and Light Independence Power and Light (IPL) offers rebates to residential customers for purchasing new, energy efficient appliances. Rebates are available on central air conditioning systems, heat pumps, and water heaters. Rebates on equipment vary based upon size, capacity, and efficiency of the unit. See

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Power Right. Power Smart. Efficient Computer Power Supplies and Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. March 10, 2009 - 6:00am Addthis John Lippert Power supplies convert the AC power that you get from your electric company into the DC power consumed by most electronics, including your computer. We expect our power supplies to be safe, reliable, and durable. If they meet those criteria, then they're all alike, except for cost, right? Well, not exactly. You see, there's one other important feature that sets them apart: efficiency. And I don't know about you, but I believe waste is bad. For me, high efficiency is one important feature that's needed for something to be high quality. So isn't it ridiculous that most power

322

Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Power Right. Power Smart. Efficient Computer Power Supplies and Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. March 10, 2009 - 6:00am Addthis John Lippert Power supplies convert the AC power that you get from your electric company into the DC power consumed by most electronics, including your computer. We expect our power supplies to be safe, reliable, and durable. If they meet those criteria, then they're all alike, except for cost, right? Well, not exactly. You see, there's one other important feature that sets them apart: efficiency. And I don't know about you, but I believe waste is bad. For me, high efficiency is one important feature that's needed for something to be high quality. So isn't it ridiculous that most power

323

Efficient data IO for a Parallel Global Cloud Resolving Model  

SciTech Connect

Execution of a Global Cloud Resolving Model (GCRM) at target resolutions of 2-4 km will generate, at a minimum, 10s of Gigabytes of data per variable per snapshot. Writing this data to disk without creating a serious bottleneck in the execution of the GCRM code while also supporting efficient post-execution data analysis is a significant challenge. This paper discusses an Input/Output (IO) application programmer interface (API) for the GCRM that efficiently moves data from the model to disk while maintaining support for community standard formats, avoiding the creation of very large numbers of files, and supporting efficient analysis. Several aspects of the API will be discussed in detail. First, we discuss the output data layout which linearizes the data in a consistent way that is independent of the number of processors used to run the simulation and provides a convenient format for subsequent analyses of the data. Second, we discuss the flexible API interface that enables modelers to easily add variables to the output stream by specifying where in the GCRM code these variables are located and to flexibly configure the choice of outputs and distribution of data across files. The flexibility of the API is designed to allow model developers to add new data fields to the output as the model develops and new physics is added and also provides a mechanism for allowing users of the GCRM code itself to adjust the output frequency and the number of fields written depending on the needs of individual calculations. Third, we describe the mapping to the NetCDF data model with an emphasis on the grid description. Fourth, we describe our messaging algorithms and IO aggregation strategies that are used to achieve high bandwidth while simultaneously writing concurrently from many processors to shared files. We conclude with initial performance results.

Palmer, Bruce J.; Koontz, Annette S.; Schuchardt, Karen L.; Heikes, Ross P.; Randall, David A.

2011-11-26T23:59:59.000Z

324

Design of fast output sampling feedback control for smart structure model  

Science Journals Connector (OSTI)

In this paper, the problem of modelling and output feedback control design for a smart structural system using piezoelectric material as a sensor/actuator is addressed. The model for a smart cantilever beam is developed by the finite element method. ... Keywords: output feedback, smart structure, vibration control

M. Umapathy; B. Bandyopadhyay

2007-01-01T23:59:59.000Z

325

Estimating Solar PV Output Using Modern Space/Time Geostatistics (Presentation)  

SciTech Connect

This presentation describes a project that uses mapping techniques to predict solar output at subhourly resolution at any spatial point, develop a methodology that is applicable to natural resources in general, and demonstrate capability of geostatistical techniques to predict the output of a potential solar plant.

Lee, S. J.; George, R.; Bush, B.

2009-04-29T23:59:59.000Z

326

PWM Inverter Output Filter Cost to Losses Trade Off and Optimal Design  

E-Print Network (OSTI)

PWM Inverter Output Filter Cost to Losses Trade Off and Optimal Design Robert J. Pasterczyk Jean--This paper describes how to design the output filter of a PWM inverter used in a Uninterruptible Power SupplyVA 3-ph. PWM inverter is taken as example. B. Design Constraints Uninterruptible Power Supply (UPS

Paris-Sud XI, Université de

327

Quality assurance of solar thermal systems with the ISFH-Input/Output-Procedure  

E-Print Network (OSTI)

. Supplementary sensors may be necessary for some special solar systems (e. g. solar systems with several storagesQuality assurance of solar thermal systems with the ISFH- Input/Output-Procedure Peter Paerisch/Output-Controllers for in situ and automatic function control of solar thermal systems that were developed within the research

328

A Method of Decreasing Power Output Fluctuation of Solar Chimney Power Generating Systems  

Science Journals Connector (OSTI)

Severe fluctuation of power output is a common problem in the various generating systems of renewable energies. The hybrid energy storage system with water and soil is adopted to decrease the fluctuation of solar chimney power generating systems in the ... Keywords: Solar chimney power generating system, power output fluctuation, hybrid energy storage layer, collector, chimney

Meng Fanlong; Ming Tingzhen; Pan Yuan

2011-01-01T23:59:59.000Z

329

Statistical post processing of model output from the air quality model LOTOS-EUROS  

E-Print Network (OSTI)

Statistical post processing of model output from the air quality model LOTOS-EUROS Annemiek processing of model output from the air quality model LOTOS-EUROS Author: Annemiek Pijnappel Supervisor summary Air quality forecasts are produced routinely, focusing on concentrations of polluting gases

Stoffelen, Ad

330

Optimizing the Output of a Human-Powered Energy Harvesting System with Miniaturization and Integrated Control  

E-Print Network (OSTI)

1 Optimizing the Output of a Human-Powered Energy Harvesting System with Miniaturization mechanical energy from human foot-strikes and explore its configuration and control towards optimized energy output. Dielectric Elastomers (DEs) are high-energy density, soft, rubber-like material

Potkonjak, Miodrag

331

Optimization on Solar Panels: Finding the Optimal Output Brian Y. Lu  

E-Print Network (OSTI)

Optimization on Solar Panels: Finding the Optimal Output Brian Y. Lu January 1, 2013 1 Introduction of solar panel: Routing the configuration between solar cells with a switch matrix. However, their result models and control policies for the optimal output of solar panels. The smallest unit on a solar panel

Lavaei, Javad

332

Method for leveling the power output of an electromechanical battery as a function of speed  

DOE Patents (OSTI)

The invention is a method of leveling the power output of an electromechanical battery during its discharge, while at the same time maximizing its power output into a given load. The method employs the concept of series resonance, employing a capacitor the parameters of which are chosen optimally to achieve the desired near-flatness of power output over any chosen charged-discharged speed ratio. Capacitors are inserted in series with each phase of the windings to introduce capacitative reactances that act to compensate the inductive reactance of these windings. This compensating effect both increases the power that can be drawn from the generator before inductive voltage drops in the windings become dominant and acts to flatten the power output over a chosen speed range. The values of the capacitors are chosen so as to optimally flatten the output of the generator over the chosen speed range. 3 figs.

Post, R.F.

1999-03-16T23:59:59.000Z

333

Design and analysis of modern three-phase AC/AC power converters for AC drives and utility interface  

E-Print Network (OSTI)

output current/voltage waveforms and fast dynamic response in high power areas. A new topology and control scheme for a six-step current source inverter is proposed. The proposed topology utilizes a small voltage source inverter, to turn off main...

Kwak, Sangshin

2005-08-29T23:59:59.000Z

334

Output-increasing, protective cover for a solar cell  

DOE Patents (OSTI)

A flexible cover (14) for a flexible solar cell (12) protects the cell from the ambient and increases the cell's efficiency. The cell(12)includes silicon spheres (16) held in a flexible aluminum sheet matrix (20,22). The cover (14) is a flexible, protective layer (60) of light-transparent material having a relatively flat upper, free surface (64) and an irregular opposed surface (66). The irregular surface (66) includes first portions (68) which conform to the polar regions (31R) of the spheres (16) and second convex (72) or concave (90) portions (72 or 90) which define spaces (78) in conjunction with the reflective surface (20T) of one aluminum sheet (20). Without the cover (14) light (50) falling on the surface (20T) between the spheres (16) is wasted, that is, it does not fall on a sphere (16). The surfaces of the second portions are non-parallel to the direction of the otherwise wasted light (50), which fact, together with a selected relationship between the refractive indices of the cover and the spaces, result in sufficient diffraction of the otherwise wasted light (50) so that about 25% of it is reflected from the surface (20T) onto a sphere (16).

Hammerbacher, Milfred D. (Dallas, TX)

1995-11-21T23:59:59.000Z

335

AC Solar Inc | Open Energy Information  

Open Energy Info (EERE)

Logo: AC Solar Inc Name AC Solar Inc Address P.O. Box 128 Place Florence, Colorado Zip 81226 Sector Solar Product Solar and wind sales for residential Website http://www.acsolar.com/ Coordinates 38.381551°, -105.112265° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.381551,"lon":-105.112265,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

336

OPTIONS for ENERGY EFFICIENCY  

E-Print Network (OSTI)

OPTIONS for ENERGY EFFICIENCY in EXISTING BUILDINGS December 2005 CEC-400-2005-039-CMF;OPTIONS FOR ENERGY EFFICIENCY in EXISTING BUILDINGS COMMISSION REPORT TABLE OF CONTENTS EXECUTIVE SUMMARY ............................................................................iii California's Successful Energy Efficiency Programs

337

Energy Efficient Radio Resource  

E-Print Network (OSTI)

Energy Efficient Radio Resource Management in a Coordinated Multi-Cell Distributed Antenna System Omer HALILOGLU Introduction System Model Performance Evaluation Conclusion References Energy Efficient Hacettepe University 5 September 2014 Omer HALILOGLU (Hacettepe University) Energy Efficient Radio Resource

Yanikomeroglu, Halim

338

Advanced Condenser Boosts Geothermal Power Plant Output (Fact Sheet), The Spectrum of Clean Energy Innovation, NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

Geothermal resources-the steam and water that lie below the earth's surface-have the Geothermal resources-the steam and water that lie below the earth's surface-have the potential to supply vast amounts of clean energy. But continuing to produce geothermal power efficiently and inexpensively can require innovative adjustments to the technology used to process it. Located in the Mayacamas Mountains of northern California, The Geysers is the world's larg- est geothermal complex. Encompassing 45 square miles along the Sonoma and Lake County border, the complex harnesses natural steam reservoirs to create clean renewable energy that accounts for one-fifth of the green power produced in California. In the late 1990s, the pressure of geothermal steam at The Geysers was falling, reducing the output of its power plants. NREL teamed with Pacific

339

Hydrogen Storage in Carbon Nanotubes A.C. Dillon, P.A. Parilla, K.E.H. Gilbert, J.L. Alleman, T. Gennett*,  

E-Print Network (OSTI)

Hydrogen Storage in Carbon Nanotubes A.C. Dillon, P.A. Parilla, K.E.H. Gilbert, J.L. Alleman, T. Gennett*, and M.J. Heben National Renewable Energy Laboratory *Rochester Institute of Technology 2003 DOE HFCIT Program Review Meeting DOE Office of Energy Efficiency and Renewable Energy DOE Office of Science

340

Renewable Energy and Energy Efficiency in Africa: Carbon Finance Guide |  

Open Energy Info (EERE)

and Energy Efficiency in Africa: Carbon Finance Guide and Energy Efficiency in Africa: Carbon Finance Guide Jump to: navigation, search Tool Summary Name: Renewable Energy and Energy Efficiency in Africa: Carbon Finance Guide Agency/Company /Organization: Renewable Energy and Energy Efficiency Partnership Sector: Energy Focus Area: Energy Efficiency, Renewable Energy Topics: Finance, Implementation Website: toolkits.reeep.org/index.php?work=detail&asset=projectOutput&id=134 References: REEEP Toolkit[1] "This Guide is an introduction to the financing of renewable energy and energy efficiency (RE/EE) projects - projects which benefit the global community by reducing greenhouse gases which are causing climate change. It is designed to help private and corporate entrepreneurs and public officials, banks and financiers, as well as donor organizations to

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Data:Ac1be58a-fdc2-4dc5-be16-8ac5f844e141 | Open Energy Information  

Open Energy Info (EERE)

8a-fdc2-4dc5-be16-8ac5f844e141 8a-fdc2-4dc5-be16-8ac5f844e141 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Otero County Electric Coop Inc Effective date: 2010/03/04 End date if known: Rate name: General Service - Optional Rate Sector: Commercial Description: Demand Charge per KW: (above 10kw) Otero County Electric Cooperative, Inc. (OCEC), with its April 10 billing, will initiate a new program involving Energy Efficiency and rebates on certain items. The new "Energy Efficiency Fund" program will begin with the March 1 kWh usage. The program will be financed by a one percent adder to Members' bills and also by retaining the inspection and supervision fees that were previously paid to the New Mexico Public Regulation Commission (PRC). The OCEC Board of Trustees (Board) approved the basics of the fund at the January Board Meeting and will determine those programs that continue to provide the needed services to our Members.

342

Energy efficiency standards for residential and commercial equipment: Additional  

NLE Websites -- All DOE Office Websites (Extended Search)

207 207 Energy Efficiency Standards for Residential and Commercial Equipment: Additional Opportunities Greg Rosenquist, Michael McNeil, Maithili Iyer, Steve Meyers, and Jim McMahon Environmental Energy Technologies Division Lawrence Berkeley National Laboratory University of California Berkeley, CA 94720 September 2004 This work was supported by the National Commission on Energy Policy through the U.S. Department of Energy under Contract No. DE-AC03-76SF00098. Table of Contents 1. Introduction........................................................................1 2. Products Considered..............................................................2 3. Technology Cost-Efficiency Analysis...........................................3

343

Duquesne Light Company - Commercial and Industrial Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Duquesne Light Company - Commercial and Industrial Energy Duquesne Light Company - Commercial and Industrial Energy Efficiency Program Duquesne Light Company - Commercial and Industrial Energy Efficiency Program < Back Eligibility Commercial Fed. Government Industrial Institutional Local Government Schools State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Commercial Weatherization Manufacturing Appliances & Electronics Commercial Lighting Lighting Program Info State Pennsylvania Program Type Utility Rebate Program Rebate Amount Custom: Varies Lighting: Varies widely by type Controls and Sensors: $10-$75 VFD for Chilled Water Loop $150/hp VFD for HVAC Fans: $80/hp Packaged Terminal AC: $45-$75/ton Food Service Equipment: Varies widely by type Refrigeration Equipment: Varies widely by type

344

Empire Electric Association - Residential Energy Efficiency Credit Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Residential State Government Savings Category Appliances & Electronics Heating & Cooling Commercial Heating & Cooling Heat Pumps Water Heating Program Info State Colorado Program Type Utility Rebate Program Rebate Amount HVAC Equipment: $250 - $300; additional rebates available for higher efficiency levels Controlled Resistance Heating: $24 - $32/kW Terminal Unit Heat Pump: $170 Water Heater: $100; additional rebates available for warranties, timers, and controls Split System A/C: $300/unit Refrigerator/freezer: $90/unit Refrigerator/freezer Recycling: $40 Dishwasher: $60 Clothes Washer: $80 Provider Empire Electric Association, Inc. Empire Electric Association provides financial incentives to its residential consumers who upgrade to energy efficient appliances and HVAC

345

Direct amplitude detuning measurement with ac dipole  

In circular machines, nonlinear dynamics can impact parameters such as beam lifetime and could result in limitations on the performance reach of the accelerator. Assessing and understanding these effects in experiments is essential to confirm the accuracy of the magnetic model and improve the machine performance. A direct measurement of the machine nonlinearities can be obtained by characterizing the dependency of the tune as a function of the amplitude of oscillations (usually defined as amplitude detuning). The conventional technique is to excite the beam to large amplitudes with a single kick and derive the tune from turn-by-turn data acquired with beam position monitors. Although this provides a very precise tune measurement it has the significant disadvantage of being destructive. An alternative, nondestructive way of exciting large amplitude oscillations is to use an ac dipole. The perturbation Hamiltonian in the presence of an ac dipole excitation shows a distinct behavior compared to the free oscillations which should be correctly taken into account in the interpretation of experimental data. The use of an ac dipole for direct amplitude detuning measurement requires careful data processing allowing one to observe the natural tune of the machine; the feasibility of such a measurement is demonstrated using experimental data from the Large Hadron Collider. An experimental proof of the theoretical derivations based on measurements performed at injection energy is provided as well as an application of this technique at top energy using a large number of excitations on the same beam.

White, S.; Maclean, E.; Tomás, R.

2013-07-01T23:59:59.000Z

346

Transportation Efficiency Resources  

Energy.gov (U.S. Department of Energy (DOE))

Transportation efficiency reduces travel demand as measured by vehicle miles traveled (VMT). While transportation efficiency policies are often implemented under local governments, national and...

347

SM Energy-Efficient  

E-Print Network (OSTI)

SM 111 Energy Energy-Efficient Ventilation for Apartment Buildings #12. These Guides provide clear and practical information on issues related to energy-efficient building retrofits

Diamond, Richard

348

Wall-plug (AC) power consumption of a very high energy e+/e- storage ring collider  

E-Print Network (OSTI)

Estimated AC power consumption ranges from ~280 MW (1) to 416 MW (2) for a 350 GeV E_cm 80 km circumference colliding beam storage ring complex with parameters given in (1). The difference between the two estimates is from differing assumptions concerning heat removal, cryo-plant efficiency, klystron operation etc. The purpose of this note is to list and explain these. (1) Mike Koratzinos, et al, IPAC13 (2) Marc Ross, Higgs Quo Vadis Workshop, March 2013.

Ross, Marc C

2013-01-01T23:59:59.000Z

349

X-ray source assembly having enhanced output stability, and fluid stream analysis applications thereof  

DOE Patents (OSTI)

An x-ray source assembly and method of operation are provided having enhanced output stability. The assembly includes an anode having a source spot upon which electrons impinge and a control system for controlling position of the anode source spot relative to an output structure. The control system can maintain the anode source spot location relative to the output structure notwithstanding a change in one or more operating conditions of the x-ray source assembly. One aspect of the disclosed invention is most amenable to the analysis of sulfur in petroleum-based fuels.

Radley, Ian (Glenmont, NY); Bievenue, Thomas J. (Delmar, NY); Burdett, John H. (Charlton, NY); Gallagher, Brian W. (Guilderland, NY); Shakshober, Stuart M. (Hudson, NY); Chen, Zewu (Schenectady, NY); Moore, Michael D. (Alplaus, NY)

2008-06-08T23:59:59.000Z

350

www.sheffield.ac.uk/careers Develop Your  

E-Print Network (OSTI)

Marketplace' run by the Careers Service and HSBC Bank www.shef. ac.uk/careers/students/advice/sfs. 10. If you

Martin, Stephen John

351

EA-1918: Final Rule, 10 CFR 433, "Energy Efficiency Standards for New  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EA-1918: Final Rule, 10 CFR 433, "Energy Efficiency Standards for EA-1918: Final Rule, 10 CFR 433, "Energy Efficiency Standards for New Federal Commercial and MultiFamily High-Rise Residential Buildings" RIN 1904-AC60 EA-1918: Final Rule, 10 CFR 433, "Energy Efficiency Standards for New Federal Commercial and MultiFamily High-Rise Residential Buildings" RIN 1904-AC60 SUMMARY This EA evaluates the environmental impacts of implementing provisions in the Energy Conservation and Production Act (ECPA) that require DOE to update the baseline Federal energy efficiency performance standards for the construction of new Federal buildings, including commercial and multi-family high-rise residential buildings. This EA addresses Federal commercial standard to the American Society of Heating, Refrigerating, and Air-n Engineers (ASHRAE) Standard 90.1-2010. The Final Rule was published

352

Jo-Carroll Energy - Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Jo-Carroll Energy - Energy Efficiency Rebate Program Jo-Carroll Energy - Energy Efficiency Rebate Program Jo-Carroll Energy - Energy Efficiency Rebate Program < Back Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Commercial Lighting Lighting Water Heating Program Info State Illinois Program Type Utility Rebate Program Rebate Amount Electric Dehumidifier: $25 Refrigerator: $25 Window AC: $25 Dishwasher: $25 Clothes Washer: $25 Refrigerator/Freezer Recycling: $25 Window AC Recycling: $25 Lighting Measures: $2 - $15/unit Natural Gas Furnace: $125 Boiler: $125 Natural Gas Water Heater: $50 Natural Gas Dryer: $50 Natural Gas Stove: $50 Jo-Carroll Energy Cooperative, Inc. (JCECI) offers a variety of rebates on energy efficient equipment to members receiving electric or natural gas

353

EA-1918: Final Rule, 10 CFR 433, "Energy Efficiency Standards for New  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

18: Final Rule, 10 CFR 433, "Energy Efficiency Standards for 18: Final Rule, 10 CFR 433, "Energy Efficiency Standards for New Federal Commercial and MultiFamily High-Rise Residential Buildings" RIN 1904-AC60 EA-1918: Final Rule, 10 CFR 433, "Energy Efficiency Standards for New Federal Commercial and MultiFamily High-Rise Residential Buildings" RIN 1904-AC60 SUMMARY This EA evaluates the environmental impacts of implementing provisions in the Energy Conservation and Production Act (ECPA) that require DOE to update the baseline Federal energy efficiency performance standards for the construction of new Federal buildings, including commercial and multi-family high-rise residential buildings. This EA addresses Federal commercial standard to the American Society of Heating, Refrigerating, and Air-n Engineers (ASHRAE) Standard 90.1-2010. The Final Rule was published

354

Method and apparatus for improved efficiency in a pulse-width-modulated alternating current motor drive  

DOE Patents (OSTI)

A scheme for optimizing the efficiency of an AC motor drive operated in a pulse-width-modulated mode provides that the modulation frequency of the power furnished to the motor is a function of commanded motor torque and is higher at lower torque requirements than at higher torque requirements. 6 figs.

Konrad, C.E.; Boothe, R.W.

1996-01-23T23:59:59.000Z

355

Method and apparatus for improved efficiency in a pulse-width-modulated alternating current motor drive  

DOE Patents (OSTI)

A scheme for optimizing the efficiency of an AC motor drive operated in a pulse-width-modulated mode provides that the modulation frequency of the power furnished to the motor is a function of commanded motor torque and is higher at lower torque requirements than at higher torque requirements.

Konrad, Charles E. (Roanoke, VA); Boothe, Richard W. (Roanoke, VA)

1996-01-01T23:59:59.000Z

356

Method and apparatus for improved efficiency in a pulse-width-modulated alternating current motor drive  

DOE Patents (OSTI)

A scheme for optimizing the efficiency of an AC motor drive operated in a pulse-width-modulated mode provides that the modulation frequency of the power furnished to the motor is a function of commanded motor torque and is higher at lower torque requirements than at higher torque requirements.

Konrad, Charles E. (Roanoke, VA); Boothe, Richard W. (Roanoke, VA)

1994-01-01T23:59:59.000Z

357

An Energy-Efficient and Scalable eDRAM-Based Register File Architecture for GPGPU  

E-Print Network (OSTI)

An Energy-Efficient and Scalable eDRAM-Based Register File Architecture for GPGPU Naifeng Jing 1}@ac.upc.edu ABSTRACT The heavily-threaded data processing demands of streaming multiprocessors (SM) in a GPGPU require of multi-ported RF, most of the RFs in modern GPGPU are heavily banked but not multi-ported to reduce

Guo, Minyi

358

Maryland Efficiency Program Options  

Energy.gov (U.S. Department of Energy (DOE))

Maryland Efficiency Program Options, from the Tool Kit Framework: Small Town University Energy Program (STEP).

359

Energy Efficient Buildings Hub  

Energy.gov (U.S. Department of Energy (DOE))

Energy Efficient Buildings HUB Lunch Presentation for the 2013 Building Technologies Office's Program Peer Review

360

Industrial Energy Efficiency Assessments  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Energy Efficiency Assessments Lynn Price Staff Scientist China Energy Group Energy Analysis Department Environmental Energy Technologies Division Lawrence Berkeley National Laboratory Industrial Energy Efficiency Assessments - Definition and overview of key components - International experience - Chinese situation and recommendations - US-China collaboration Industrial Energy Efficiency Assessments - Analysis of the use of energy and potential for energy efficiency in an industrial facility * Current situation * Recommendations for improving energy efficiency * Cost-benefit analysis of recommended options * An action plan for realizing potential savings Types of Industrial Energy Efficiency Assessments - Preliminary or walk-through - Detailed or diagnostic Audit criteria

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

The Impact of Best Track Discrepancies on Global Tropical Cyclone Climatologies using IBTrACS  

Science Journals Connector (OSTI)

Using the International Best Track Archive for Climate Stewardship (IBTrACS), the climatology of tropical cyclones is compared between two global best track datasets: 1) the World Meteorological Organization (WMO) subset of IBTrACS (IBTrACS-WMO) ...

Carl J. Schreck III; Kenneth R. Knapp; James P. Kossin

2014-10-01T23:59:59.000Z

362

E-Print Network 3.0 - ac voltage standard Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

"volts, AC"), the "secondary" voltage is roughly 6 VAC. We shall use the "Universal Transformer... :" conversion of AC to DC You can use a diode to convert the AC voltage of the...

363

E-Print Network 3.0 - ac systems Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Summary: -6261 E-mail: kuni@mind.c.u-tokyo.ac.jp http:mind.c.u-tokyo.ac.jpindex-j.html 1890 20 Systems... 12;1 4647 4025 http:bio.c.u-tokyo.ac... ......

364

E-Print Network 3.0 - ac graftrope system Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Summary: -6261 E-mail: kuni@mind.c.u-tokyo.ac.jp http:mind.c.u-tokyo.ac.jpindex-j.html 1890 20 Systems... 12;1 4647 4025 http:bio.c.u-tokyo.ac... ......

365

Missouri Rural Electric Cooperative - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Missouri Rural Electric Cooperative - Residential Energy Efficiency Missouri Rural Electric Cooperative - Residential Energy Efficiency Rebate Program Missouri Rural Electric Cooperative - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Heating & Cooling Commercial Heating & Cooling Heat Pumps Commercial Lighting Lighting Water Heating Cooling Program Info State Missouri Program Type Utility Rebate Program Rebate Amount Clothes Washer: $100 Dishwasher: $50 Room AC Unit: $50 Water Heaters: $50 - $100 CFL Light Bulbs: Free Geothermal Heat Pumps: $250/ton Ground Loop Replacement: $500/ton Dual Fuel Air Source Heat Pumps: $150/ton Provider Missouri Rural Electric Cooperative Missouri Rural Electric Cooperative (MREC) offers a number of rebates to residential customers for the purchase and installation of energy efficient

366

Florida Power and Light - Residential Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Florida Power and Light - Residential Energy Efficiency Program Florida Power and Light - Residential Energy Efficiency Program Florida Power and Light - Residential Energy Efficiency Program < Back Eligibility Installer/Contractor Multi-Family Residential Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Sealing Your Home Ventilation Heat Pumps Insulation Design & Remodeling Program Info State Florida Program Type Utility Rebate Program Rebate Amount Residential Home Energy Survey: Free A/C and Heat Pump: $140 - $1930, depending on system size and efficiency rating Reflective Roof (Metal or Tile): $325 Duct Test: Discounted Single Family Duct System Repair: up to $154 Multi-family and Manufactured Home Duct System Repair: $60/account Ceiling and Roof Insulation: varies based upon existing insulation levels

367

Kentucky Utilities Company - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Kentucky Utilities Company - Residential Energy Efficiency Rebate Kentucky Utilities Company - Residential Energy Efficiency Rebate Program (Kentucky) Kentucky Utilities Company - Residential Energy Efficiency Rebate Program (Kentucky) < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Water Heating Windows, Doors, & Skylights Program Info State Kentucky Program Type Utility Rebate Program Rebate Amount Heat Pump Water Heater: $300 Refrigerator: $100 Freezer: $50 Clothes Washer: $75 Dishwasher: $50 Window Film: 50% of material cost, up to $200 Central AC: $100, plus $100 for each SEER above minimum federal high efficiency standard Air-Source Heat Pump: $100, plus $100 for each SEER above minimum federal

368

City of Danville Utilities - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

City of Danville Utilities - Residential Energy Efficiency Rebate City of Danville Utilities - Residential Energy Efficiency Rebate Program (Virginia) City of Danville Utilities - Residential Energy Efficiency Rebate Program (Virginia) < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Water Heating Maximum Rebate HVAC Tune-Up: 1 incentive per 3 years Program Info Start Date 06/15/2011 State Virginia Program Type Utility Rebate Program Rebate Amount Clothes Washer: $50 Refrigerator: $30 Central AC: $145 - $250 Air Source Heat Pumps: $350 Heat Pump Water Heater: $100 High Efficiency Water Heater: $25 HVAC Tune-Up: $55 Attic Insulation (Tier 1): $0.08/sq ft Attic Insulation (Tier 2): $0.15/sq ft

369

PNM - Residential Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PNM - Residential Energy Efficiency Rebate Program PNM - Residential Energy Efficiency Rebate Program PNM - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Refrigerator/Freezer Recycling: 2 units per household Program Info State New Mexico Program Type Utility Rebate Program Rebate Amount +Refrigerator/Freezer Recycling: $50/unit Compact Fluorescent Light Bulbs (CFLs): point-of-purchase discounts AC Cycling: $25 sign-up and $25/year Provider Customer Service PNM offers incentives for residential customers to improve the efficiency of eligible homes. PNM will provide a $50 rebate for the proper recycling of old refrigerators or freezers. Customers who agree to cycle the operation of residential air conditioning systems are also eligible for a

370

Morgan County REA - Efficiency Credit/Rebate Programs | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Morgan County REA - Efficiency Credit/Rebate Programs Morgan County REA - Efficiency Credit/Rebate Programs Morgan County REA - Efficiency Credit/Rebate Programs < Back Eligibility Commercial General Public/Consumer Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Commercial Lighting Lighting Manufacturing Water Heating Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Heat Pumps: $85 - $300/unit, varies by efficiency and configuration Geothermal Heat Pumps: $100 - $150 Room AC (Split Systems): $100 - $150 (Tri-State) Electric Thermal Storage: $24/kW Thermal Slab Units: $18/kW Electric Motors: $16/HP Wiring Assistance: $3/HP LEDs: $10 (Tri-State)

371

Louisville Gas and Electric - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Louisville Gas and Electric - Residential Energy Efficiency Rebate Louisville Gas and Electric - Residential Energy Efficiency Rebate Program (Kentucky) Louisville Gas and Electric - Residential Energy Efficiency Rebate Program (Kentucky) < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Water Heating Windows, Doors, & Skylights Program Info State Kentucky Program Type Utility Rebate Program Rebate Amount Heat Pump Water Heater: $300 Refrigerator: $100 Freezer: $50 Clothes Washer: $75 Dishwasher: $50 Window Film: 50% of material cost, up to $200 Central AC: $100, plus $100 for each SEER above minimum federal high efficiency standard Air-Source Heat Pump: $100, plus $100 for each SEER above minimum federal

372

Anoka Municipal Utility - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Anoka Municipal Utility - Residential Energy Efficiency Rebate Anoka Municipal Utility - Residential Energy Efficiency Rebate Program Anoka Municipal Utility - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Room Air Conditioner: limit of 2 units per account Lighting: limit of $15 per customer per year Program Info Expiration Date 03/31/2013 State Minnesota Program Type Utility Rebate Program Rebate Amount Ceiling Fan: $25 Clothes Washer: $25 Refrigerator: $50 Freezer: $50 Refrigerator/Freezer Recycling: $25 Freezer: $50 Dishwasher: $25 Dehumidifier: $25 Air Conditioner Tune-Up: $25 Room Air Conditioner: $25/unit Central A/C: $225 - $400, varies by efficiency

373

Residential Energy Efficiency Rebate (Offered by Several Cooperative  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate (Offered by Several Residential Energy Efficiency Rebate (Offered by Several Cooperative Utilities) Residential Energy Efficiency Rebate (Offered by Several Cooperative Utilities) < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State Iowa Program Type Utility Rebate Program Rebate Amount Window AC Unit: $50 Electric Water Heaters: $50 New Ground-Source Heat Pump: up to $750/ton Replacement Ground-Source Heat Pump: $150/ton Air Source Heat Pump: $150/ton Provider Associated Electric Cooperative Associated Electric Cooperative and many of its member cooperatives offer rebates to residential customers who purchase and install energy efficient equipment for the home. Eligible equipment includes room air conditioners,

374

Kissimmee Utility Authority - Commercial Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Energy Efficiency Rebate Commercial Energy Efficiency Rebate Program Kissimmee Utility Authority - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Lighting Retrofit: $2,500 Program Info State Florida Program Type Utility Rebate Program Rebate Amount Duct Leak Repair: up to $75 Central AC Maintenance: up to $50 Heat Pump: $225 Insulation: up to $100 CFLs: up to $15 LED Exit Signs: $25 Lighting Retrofit: $150/kW Provider Senior Energy Conservation Specialist Kissimmee Utility Authority (KUA) offers several rebates to commercial customers for energy efficiency improvements. Rebates are available for HVAC maintenance, heat pumps, duct leak repairs, insulation, LED exit signs

375

PSNH - New Construction Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PSNH - New Construction Energy Efficiency Rebate Program PSNH - New Construction Energy Efficiency Rebate Program PSNH - New Construction Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Program Info State New Hampshire Program Type Utility Rebate Program Rebate Amount T8 Fixtures: $15/unit Remote Occupancy Sensor: $50/unit Daylight Dimming Controls: $25/unit ECM Motors: $150 Variable Frequency Drives: $800 - $1,575 Unitary AC/Split Systems: $50 - $175/ton Air Source Heat Pumps: $50 - $175/ton Water Source Heat Pumps: $80/ton Geothermal Heat Pumps: $150/ton Dual Enthalpy Economizer: $225/unit Demand Control Ventilation: $200/unit Chillers: $11 - $25/ton; plus bonus efficiency incentive

376

Residential Energy Efficiency Rebate (Offered by Several Cooperative  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate (Offered by Several Residential Energy Efficiency Rebate (Offered by Several Cooperative Utilities) Residential Energy Efficiency Rebate (Offered by Several Cooperative Utilities) < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Cooling Program Info State Oklahoma Program Type Utility Rebate Program Rebate Amount Room A/C Unit: $50 Electric Water Heaters: $50 - $200 New Geothermal Heat Pump: up to $750/ton Replacement Geothermal Heat Pump: $150/ton Air-Source Heat Pump: $150/ton Provider Associated Electric Cooperative Associated Electric Cooperative and many of its member cooperatives offer rebates to residential customers who purchase and install energy efficient equipment for the home. Eligible equipment includes room air conditioners,

377

Long-Term Shifts in Life-Cycle Energy Efficiency and Carbon Intensity  

Science Journals Connector (OSTI)

System-level life-cycle efficiency may decrease as mitigation efforts intensify, since low-efficiency renewable systems with high output have much lower GHG emissions than some high-efficiency fossil fuel systems. ... Climate policies accelerate both improvements in EF and the adoption of renewable technologies, resulting in considerably lower primary energy demand and GHG emissions. ... Schipper, L.; Saenger, C.; Sudardshan, A.Transport and carbon emissions in the United States: The Long View Energies 2011, 4, 563– 581 ...

Sonia Yeh; Gouri Shankar Mishra; Geoff Morrison; Jacob Teter; Raul Quiceno; Kenneth Gillingham; Xavier Riera-Palou

2013-02-14T23:59:59.000Z

378

New Research Center to Increase Safety and Power Output of U.S. Nuclear  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Research Center to Increase Safety and Power Output of U.S. New Research Center to Increase Safety and Power Output of U.S. Nuclear Reactors New Research Center to Increase Safety and Power Output of U.S. Nuclear Reactors May 3, 2011 - 3:41pm Addthis Oak Ridge, Tenn. - Today the Department of Energy dedicated the Consortium for Advanced Simulation of Light Water Reactors (CASL), an advanced research facility that will accelerate the advancement of nuclear reactor technology. CASL researchers are using supercomputers to study the performance of light water reactors and to develop highly sophisticated modeling that will help accelerate upgrades at existing U.S. nuclear plants. These upgrades could improve the energy output of our existing reactor fleet by as much as seven reactors' worth at a fraction of the cost of building new reactors, while providing continued improvements in

379

Ensemble regression : using ensemble model output for atmospheric dynamics and prediction  

E-Print Network (OSTI)

Ensemble regression (ER) is a linear inversion technique that uses ensemble statistics from atmospheric model output to make dynamical inferences and forecasts. ER defines a multivariate regression operator using ensemble ...

Gombos, Daniel (Daniel Lawrence)

2009-01-01T23:59:59.000Z

380

Primate Motor Cortex: Individual and Ensemble Neuron-Muscle Output Relationships  

E-Print Network (OSTI)

The specific aims of this study were to: 1) investigate the encoding of forelimb muscle activity timing and magnitude by corticomotoneuronal (CM) cells, 2) test the stability of primary motor cortex (M1) output to forelimb ...

Griffin, Darcy Michelle

2008-07-30T23:59:59.000Z

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Augmentation of Power Output of Axisymmetric Ducted Wind Turbines by Porous Trailing Edge Disks  

E-Print Network (OSTI)

This paper presents analytical and experimental results that demonstrated that the power output from a ducted wind turbine can be dramatically increased by the addition of a trailing edge device such as a porous disk. In ...

widnall, sheila

2014-06-30T23:59:59.000Z

382

A Hardware Implementation of the Soft Output Viterbi Algorithm for Serially Concatenated Convolutional Codes  

E-Print Network (OSTI)

This thesis outlines the hardware design of a soft output Viterbi algorithm decoder for use in a serially concatenated convolutional code system. Convolutional codes and their related structures are described, as well as the algorithms used...

Werling, Brett William

2010-06-28T23:59:59.000Z

383

Code design for multiple-input multiple-output broadcast channels  

E-Print Network (OSTI)

Recent information theoretical results indicate that dirty-paper coding (DPC) achieves the entire capacity region of the Gaussian multiple-input multiple-output (MIMO) broadcast channel (BC). This thesis presents practical code designs for Gaussian...

Uppal, Momin Ayub

2009-06-02T23:59:59.000Z

384

Cardiac output and stroke volume estimation using a hybrid of three models  

E-Print Network (OSTI)

Cardiac output (CO) and stroke volume (SV) are the key hemodynamic parameters to be monitored and assessed in ambulatory and critically ill patients. The purpose of this study was to introduce and validate a new algorithm ...

Arai, Tatsuya

385

Power output enhancement of a vibration-driven electret generator for wireless sensor applications  

Science Journals Connector (OSTI)

We developed a compact vibration-driven electret generator that excelled at a power output. It succeeded in the operation of wireless sensor modules only on electricity from electret generators. This electret generator can supply enough power to operate a wireless sensor module without an external power source. It was necessary for enabling this operation to enhance the power output of the electret generator. We enhanced the power output by decreasing the parasitic capacitance. To decrease the parasitic capacitance, we fabricated a collector substrate using concave electrodes. We decreased it from 25 to 17 pF. As a result, the power output from our generator was enhanced from 40 to 100 ”W considerably at an acceleration of 0.15 g (1.47 m s?2) and a resonance frequency of 30 Hz.

Tatsuakira Masaki; Kenji Sakurai; Toru Yokoyama; Masayo Ikuta; Hiroshi Sameshima; Masashi Doi; Tomonori Seki; Masatoshi Oba

2011-01-01T23:59:59.000Z

386

Variable-Speed Wind Generator System with Maximum Output Power Control  

Science Journals Connector (OSTI)

To achieve maximum output power from wind generator systems, the rotational speed of wind generators should be adjusted in real time according to natural wind speed. This chapter pays attention to an optimum rota...

Yoko Amano

2013-01-01T23:59:59.000Z

387

Total Pollution Effect and Total Energy Cost per Output of Different Products for Polish Industrial System  

Science Journals Connector (OSTI)

For many years a broad use has been made of the indices of total energy requirements in the whole large production system corresponding to unit output of particular goods (Boustead I., Hancock G.F., 1979). The...

Henryk W. Balandynowicz

1988-01-01T23:59:59.000Z

388

The Blast Energy Efficiency of GRBs  

E-Print Network (OSTI)

Using data mostly assembled by previous authors, we consider the linear correlation between the apparent radiative efficiency $\\epsilon_{\\gamma}$ (defined as the ratio of isotropic equivalent radiative output to inferred isotropic equivalent kinetic energy of the blast) and $E_{peak}^{\\alpha}$ where $1.4<\\alpha<2$, for 17 of 22 GRBs (Lloyd-Ronning and Zhang, 2004). We note in a quantitative manner that this is consistent with the hypothesis that $\\epsilon_{\\gamma}$ and $E_{peak}$ are influenced by viewing angle. We suggest a more general theoretically derived expression for this correlation that could be tested with a richer data set. If the reduction in both $\\epsilon_{\\gamma}$ and $E_{peak}$ is due to viewing angle effects, then the actual radiative efficiency is $\\sim 7$. We also find preliminary evidence (with a small sample) for a separate class of weak GRB afterglows.

David Eichler Daniel Jontof-Hutter

2005-03-24T23:59:59.000Z

389

Imprinting a complete information about a quantum channel on its output state  

E-Print Network (OSTI)

We introduce a novel property of bipartite quantum states, which we call "faithfulness", and we say that a state is faithful when acting with a channel on one of the two quantum systems, the output state carries a complete information about the channel. The concept of faithfulness can also be extended to sets of states, when the output states patched together carry a complete imprinting of the channel.

Giacomo Mauro D'Ariano; Paoloplacido Lo Presti

2002-11-20T23:59:59.000Z

390

Modelling Dynamic Constraints in Electricity Markets and the Costs of Uncertain Wind Output  

E-Print Network (OSTI)

shifts between periods. Finally, higher variable costs, incurred if power stations are operated below their optimal rating, are allocated to the locally lowest de- mand. For inflexible power stations like nuclear, combined cycle gas turbines or coal... the start of the station has to be decided several hours before delivering output. At the earlier time there is still uncertainty about the future demand, possible failures of power stations and predictions for wind-output. We represent the uncertainty...

Musgens, Felix; Neuhoff, Karsten

2006-03-14T23:59:59.000Z

391

CO2 sorption and reaction kinetic performance of K2CO3/AC in low temperature and CO2 concentration  

Science Journals Connector (OSTI)

Abstract Reducing or removing CO2 is critical to the confined spaces such as submarines, space-crafts or aircrafts while using solid sorbents has been regarded as a promising method. In this work, K2CO3 loaded on activated carbon (K2CO3/AC) was developed as a new and regenerable sorbent for CO2 removing in confined spaces. CO2 sorption performances of K2CO3/AC were investigated under different conditions by varying the K2CO3 loadings, CO2 concentrations, H2O concentrations, CO2 sorption temperatures and water pretreatment durations as well as the purge gas flow rates. The CO2 sorption capacity and carbonation conversion of K2CO3/AC decrease with increasing temperature and increase with increasing mole ratio of H2O concentration over CO2 concentration. Sufficient water vapor pretreatment is found to be beneficial to the sorption-enhanced performance. Increasing flow rate will weaken the CO2 sorption performance. The carbonation kinetics was also investigated with the correlation between the shrinking core model and experimental data. Additionally, the sorbent is proved to be regenerable and stable during 20-cycle CO2 sorption–desorption experiments. K2CO3/AC presents high carbonation conversion efficiency, high thermal stability, and low dependency on CO2 partial pressure. Therefore, it can be considered as a new option for CO2 removal in confined spaces.

Yafei Guo; Chuanwen Zhao; Changhai Li; Ye Wu

2015-01-01T23:59:59.000Z

392

E-Print Network 3.0 - ac conduction properties Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

measure the dynamical conductance of electrically contacted single-walled carbon nanotubes at dc and ac... between the ac ... Source: Burke, Peter - Department of Electrical...

393

AVTA: Siemens-VersiCharge AC Level 2 Charging System Testing...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Siemens-VersiCharge AC Level 2 Charging System Testing Results AVTA: Siemens-VersiCharge AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced...

394

56TH ACS NORTHWEST REGIONAL MEETING  

Science Journals Connector (OSTI)

56TH ACS NORTHWEST REGIONAL MEETING ... Several plenary sessions and interdisciplinary public lectures will address this theme, including "Technology for the 21st Century," presented by Lura J. Powell, director, Pacific Northwest National Laboratory; "DNA and Molecular Recognition," presented by Jacqueline Barton, California Institute of Technology; "Bioengineering Tissues," presented by Buddy Ratner, University of Washington; "History and Chemistry of Plutonium Extraction at Hanford," presented by Earl Wheelwright, Pacific Northwest National Laboratory; "Life in the Universe," presented by Donald Brownlee, University ofWashington; "Climate Change: How Will It Affect the Pacific Northwest?" presented by Jae Edmonds, Pacific Northwest National Laboratory; and "The Future of Science Education," presented by ... ...

2001-05-14T23:59:59.000Z

395

High-Efficiency Nitride-Based Photonic Crystal Light Sources  

Energy.gov (U.S. Department of Energy (DOE))

The University of California Santa Barbara (UCSB) is maximizing the efficiency of a white LED by enhancing the external quantum efficiency using photonic crystals to extract light that would normally be confined in a conventional structure. Ultimate efficiency can only be achieved by looking at the internal structure of light. To do this, UCSB is focusing on maximizing the light extraction efficiency and total light output from light engines driven by Gallium Nitride (GaN)-based LEDs. The challenge is to engineer large overlap (interaction) between modes and photonic crystals. The project is focused on achieving high extraction efficiency in LEDs, controlled directionality of emitted light, integrated design of vertical device structure, and nanoscale patterning of lateral structure.

396

Quantum heat engines: A thermodynamic analysis of power and efficiency This article has been downloaded from IOPscience. Please scroll down to see the full text article.  

E-Print Network (OSTI)

Quantum heat engines: A thermodynamic analysis of power and efficiency This article has been that the operation and the output power of a quantum heat engine that converts incoherent thermal energy the performance of the diode. Heat engines can be characterized by maximizing their power output with respect

Mukamel, Shaul

397

Journal of Machine Learning Research 20 (2011) 115 Asian Conference on Machine Learning Learning low-rank output kernels  

E-Print Network (OSTI)

@ism.ac.jp The Institute of Statistical Mathematics 10-3 Midori-cho, Tachikawa, Tokyo 190-8562 Japan Editor: Chun-Nan Hsu

398

www.mmu.ac.uk/careers Careers & Employability Service  

E-Print Network (OSTI)

to prepare? Alison Proudlove Thursday, June 07, 2012 1 #12;www.mmu.ac.uk/careers What will we cover researched the organisation #12;www.mmu.ac.uk/careers Use your time wisely · If there are large queues , have

399

Electrostatic coalescence system with independent AC and DC hydrophilic electrodes  

DOE Patents (OSTI)

An improved electrostatic coalescence system is provided in which independent AC and DC hydrophilic electrodes are employed to provide more complete dehydration of an oil emulsion. The AC field is produced between an AC electrode array and the water-oil interface wherein the AC electrode array is positioned parallel to the interface which acts as a grounded electrode. The emulsion is introduced into the AC field in an evenly distributed manner at the interface. The AC field promotes drop-drop and drop-interface coalescence of the water phase in the entering emulsion. The continuous oil phase passes upward through the perforated AC electrode array and enters a strong DC field produced between closely spaced DC electrodes in which small dispersed droplets of water entrained in the continuous phase are removed primarily by collection at hydrophilic DC electrodes. Large droplets of water collected by the electrodes migrate downward through the AC electrode array to the interface. All phase separation mechanisms are utilized to accomplish more complete phase separation.

Hovarongkura, A. David (Arlington, VA); Henry, Jr., Joseph D. (Morgantown, WV)

1981-01-01T23:59:59.000Z

400

IT Services go.warwick.ac.uk/whatsnew2010  

E-Print Network (OSTI)

to enable us to develop it as you would like. https://start.warwick.ac.uk/ Warwick Forward Warwick Forward. The domain itself must be registered with an external company by you. http://forward.warwick.ac.uk/ Files to navigate. · Files Transfer Utility. Enable access via a drive letter in Windows Explorer (or equivalent

Davies, Christopher

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Residential Energy Efficiency Rebates (Offered by 16 Utilities) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6 Utilities) 6 Utilities) Residential Energy Efficiency Rebates (Offered by 16 Utilities) < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Construction Heat Pumps Commercial Lighting Lighting Program Info State Iowa Program Type Utility Rebate Program Rebate Amount Ceiling Fan: $25 Clothes Washer: $50 Decorative Light String: $3.50/string (6 string limit) Dehumidifier: $10 Dishwasher: $25 Refrigerator: $50 Room A/C: $15 Central A/C: $100 Furnace with ECM: $150 Air Handler with ECM: $150 Air-Source Heat Pump: $200 - $350 Geothermal Heat Pump: $200/ton Heat Pump Water Heater: $300 Programmable Thermostat: $25 Weatherization: 75% of cost, up to $750 Provider

402

Comparison of the Accuracy and Speed of Transient Mobile A/C System Simulation Models: Preprint  

SciTech Connect

The operation of air conditioning (A/C) systems is a significant contributor to the total amount of fuel used by light- and heavy-duty vehicles. Therefore, continued improvement of the efficiency of these mobile A/C systems is important. Numerical simulation has been used to reduce the system development time and to improve the electronic controls, but numerical models that include highly detailed physics run slower than desired for carrying out vehicle-focused drive cycle-based system optimization. Therefore, faster models are needed even if some accuracy is sacrificed. In this study, a validated model with highly detailed physics, the 'Fully-Detailed' model, and two models with different levels of simplification, the 'Quasi-Transient' and the 'Mapped- Component' models, are compared. The Quasi-Transient model applies some simplifications compared to the Fully-Detailed model to allow faster model execution speeds. The Mapped-Component model is similar to the Quasi-Transient model except instead of detailed flow and heat transfer calculations in the heat exchangers, it uses lookup tables created with the Quasi-Transient model. All three models are set up to represent the same physical A/C system and the same electronic controls. Speed and results of the three model versions are compared for steady state and transient operation. Steady state simulated data are also compared to measured data. The results show that the Quasi-Transient and Mapped-Component models ran much faster than the Fully-Detailed model, on the order of 10- and 100-fold, respectively. They also adequately approach the results of the Fully-Detailed model for steady-state operation, and for drive cycle-based efficiency predictions

Kiss, T.; Lustbader, J.

2014-03-01T23:59:59.000Z

403

The effect of small field output factor measurements on IMRT dosimetry  

SciTech Connect

Purpose: To evaluate how changes in the measured small field output factors affect the doses in intensity-modulated treatment planning. Methods: IMRT plans were created using Philips Pinnacle treatment planning system. The plans were optimized to treat a cylindrical target 2 cm in diameter and 2 cm in length. Output factors for 2 Multiplication-Sign 2 and 3 Multiplication-Sign 3 cm{sup 2} field sizes were changed by {+-}5%, {+-}10%, and {+-}20% increments from the baseline measurements and entered into the planning system. The treatment units were recommissioned in the treatment planning system after each modification of the output factors and treatment plans were reoptimized. All plans were delivered to a solid water phantom and dose measurements were made using an ionization chamber. The percentage differences between measured and computed doses were calculated. An Elekta Synergy and a Varian 2300CD linear accelerator were separately evaluated. Results: For the Elekta unit, decreasing the output factors resulted in higher measured than computed doses by 0.8% for -5%, 3.6% for -10%, and 8.7% for -20% steps. Increasing the output factors resulted in lower doses by 2.9% for +5%, 5.4% for +10%, and 8.3% for +20% steps. For the Varian unit no changes were observed for either increased or decreased output factors. Conclusions: The measurement accuracy of small field output factors are of importance especially when the treatment plan consists of small segments as in IMRT. The method proposed here could be used to verify the accuracy of the measured small field output factors for certain linear accelerators as well as to test the beam model. The Pinnacle treatment planning system model uses output factors as a function of jaw setting. Consequently, plans using the Elekta unit, which conforms the jaws to the segments, are sensitive to small field measurement accuracy. On the other hand, for the Varian unit, jaws are fixed and segments are modeled as blocked fields hence, the impact of small field output factors on IMRT monitor unit calculation is not evaluable by this method.

Azimi, Rezvan; Alaei, Parham; Higgins, Patrick [Department of Therapeutic Radiology-Radiation Oncology, University of Minnesota, Minneapolis, Minnesota 55455 (United States)

2012-08-15T23:59:59.000Z

404

The effect of performance-based research funding on output of R&D results in the Czech Republic  

Science Journals Connector (OSTI)

We have studied the effects of performance-based research funding introduced to the Czech (CZ) R&D system in 2008 on outputs of R&D results. We have analyzed annual changes in number of various types of publications and applications including ... Keywords: Bibliometrics, Citation analysis, Patent output, Performance-based research funding, R&D results output

Jiri Vanecek

2014-01-01T23:59:59.000Z

405

Coordination of Energy Efficiency and Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

044E 044E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Coordination of Energy Efficiency and Demand Response Charles Goldman, Michael Reid, Roger Levy and Alison Silverstein Environmental Energy Technologies Division January 2010 The work described in this report was funded by the Department of Energy Office of Electricity Delivery and Energy Reliability, Permitting, Siting and Analysis of the U.S. Department of Energy under Contract No. DE-AC02- 05CH11231. Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes

406

Building Energy Efficient Schools  

E-Print Network (OSTI)

Many new school buildings consume only half the energy required by similar efficient structures designed without energy performance as a design criterion. These are comfortable and efficient while construction costs remain about the same as those...

McClure, J. D.; Estes, J. M.

1985-01-01T23:59:59.000Z

407

Energy efficient data centers  

E-Print Network (OSTI)

Center 6.2 utilized fan coil units, rather than computerEfficiency kW/ton Fan Coil Unit Design Efficiency CFM/kWCenter 6.2 utilized fan coil units, rather than computer

Tschudi, William; Xu, Tengfang; Sartor, Dale; Koomey, Jon; Nordman, Bruce; Sezgen, Osman

2004-01-01T23:59:59.000Z

408

Applied Cognitive Science (ACS) The ACS lab is directed by Dr. Frank Ritter, professor of IST and  

E-Print Network (OSTI)

Applied Cognitive Science (ACS) Laboratory The ACS lab is directed by Dr. Frank Ritter, professor during the 2012-2013 academic year, studies cognitive modeling, cognitive architectures, human-computer interaction (HCI), and learning. He has taught cognitive modeling, cognitive architectures, HCI, human factors

Squicciarini, Anna Cinzia

409

OSRAM SYLVANIA Develops High-Efficiency LED Troffer Replacement  

Energy.gov (U.S. Department of Energy (DOE))

With the help of DOE funding, OSRAM SYLVANIA is developing a high-efficiency LED 2'x2' troffer replacement that is expected to be commercially available in the spring of 2012 and to be cost-competitive with existing troffers of that size. It is projected to have a light output of up to 4,000 lumens, an efficacy of more than 100 lm/W, and a CCT of 3500K.

410

Energy Efficiency Financing  

Office of Energy Efficiency and Renewable Energy (EERE)

Information and examples of state financing for energy efficiency programs, with descriptions on implementation methods and concerns.

411

Energy Efficiency Program Overview  

E-Print Network (OSTI)

Energy Efficiency Program Overview Clean Air Through Energy Efficiency CATEE Conference November 18-20, 2014 Dallas, TX ESL-KT-14-11-02 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 General Overview • State of Texas... enacted legislation requiring Transmission and Distribution utilities (TDUs) achieve annual goals for energy efficiency • Public Utility Commission of Texas (PUCT) implemented rules and guidelines for consistency among the TDU programs • Texas TDUs...

Mutiso,S.

2014-01-01T23:59:59.000Z

412

Energy Efficient Motors  

E-Print Network (OSTI)

.. " ENERGY EFFICIENT MOTORS W. R. Hoffmeyer General Electric Company Fort Wayne, Indiana ABSTRACT Efficiency is only one aspect of motor per formance. This paper discusses how efficiency is influenced by such factors as horsepower rating... and in cost~ saVings, especially if the power company imposes a penalty for low power factor. Increasing efficiency has a direct effect on operating cost. Increasing power factor has only an indirect and less profound effect. This was recognized by ASHRAE...

Hoffmeyer, W.

1982-01-01T23:59:59.000Z

413

Transportation Efficiency Strategies  

Gasoline and Diesel Fuel Update (EIA)

fuel efficiency through conventional engine hybrid and other technologies Reducing air pollution with conventional engine technology Hybrid and internal...

414

ENTRY LOBBY ENERGY EFFICIENCY  

E-Print Network (OSTI)

ENTRY LOBBY ENERGY EFFICIENCY Clerestory windows provide natural day-lighting.· Exterior roof SUSTAINABILITY FEATURES #12;ADMINISTRATION ENERGY EFFICIENCY High performance window glazing· minimizes heat gain ENERGY EFFICIENCY High performance window glazing· minimizes heat gain. Light-colored roofing reflects

Escher, Christine

415

Managing Energy Efficiency Improvement  

E-Print Network (OSTI)

efficiency opportunities as well as promote the use of energy efficient methodologies and technologies. If, as program results suggest, 15% to 20% of the gas that is now consumed at by plant operations can be saved through efficiencies, it would save $500...

Almaguer, J.

2006-01-01T23:59:59.000Z

416

Definition of Energy Efficiency  

U.S. Energy Information Administration (EIA) Indexed Site

Energy Users Energy Efficiency Page Energy Efficiency Definition Energy Users Energy Efficiency Page Energy Efficiency Definition Energy Efficiency: Definition Stairs) "Take the Stairs--Be More Energy Efficient" Person A interprets the sign as the "true" definition of energy efficiency. To Person A, the elevator is not being used. He is still getting to where he wants to go and using less energy in doing so. Person B considers the fact that she is not getting to where she is going with the same ease. She does not believe that she is being energy efficient, but instead she believes that she is "conserving energy" at a reduced level of service-she has to walk instead of ride. When it comes to trying to define "to be energy efficient" or "energy efficiency", there does not seem to be a single commonly-accepted definition of energy efficiency. Along the lines of Person B's thinking, it is generally thought that an increase in energy efficiency is when either energy inputs are reduced for a given level of service, or there are increased or enhanced services for a given amount of energy inputs.

417

Equivalent circuits and efficiencies of fuel cells  

Science Journals Connector (OSTI)

By introducing an equivalent thermal potential fixed in terms of the heat of reaction, a thermodynamic equivalent circuit is determined for a fuel cell which yields the correct current-potential curve of the cell for low current by formal application of Ohm's law. The thermodynamic power balance and the thermodynamic efficiency also are given correctly. A linear electrical equivalent circuit is constructed which represents closely the electrical performance of the cell over a wide range of current (not approaching zero). The effect of polarization processes on the electrical power and efficiency is taken into account through a single constant parameter. Introduction of the equivalent thermal potential into the circuit yields a thermodynamic equivalent circuit whose output computed by formal use of Ohm's law coincides exactly with that given by the electrical equivalent circuit. The correct electrical properties, thermodynamic power balance, and thermodynamic efficiency follow directly from the circuit. A general theorem is formulated, independently of the validity of an equivalent circuit, connecting the thermodynamic and electrical efficiencies of a fuel cell. Confirmatory experimental results based on hydrogen—oxygen cells are presented, which underline the large reduction in available power brought about by polarization processes and entropy changes in a fuel cell.

J.J. Gilvarry; J.I. Slaughtert

1963-01-01T23:59:59.000Z

418

A numerical method for calculation of power output from ducted vertical axis hydro-current turbines  

Science Journals Connector (OSTI)

Abstract This paper investigates effects of ducting on power output from vertical axis hydro-current turbines. A numerical two-dimensional method based on the potential flow theory is developed for calculation of non-dimensional power output from these turbines. In this method, the blades are represented by vortex filaments. The vortex shedding from the blades is modeled by discrete vortices. A boundary element method is used to incorporate the duct shape which is represented by a series of panels with constant distributions of sources and doublets. The aerodynamic loading on the blades are calculated using a quasi-steady modeling. A time-marching scheme is used for implementation of the numerical method. The results of this method are compared with experimental results for a turbine model. A good correlation between the numerical and experimental results is obtained for tip speed ratios equal and higher than 2.25. However due to a lack of dynamic stall modeling, the numerical method is not able to predict power output accurately at lower tip speed ratios wherein effects of dynamic stall are significant. Both numerical and experimental results also showed that the power output from a turbine can increase significantly when it is enclosed within a well-designed duct. The maximum power output of the turbine model investigated in this paper showed a 74% increase when the turbine is operating within the duct relative to the case it is in free-stream conditions.

Mahmoud Alidadi; Sander Calisal

2014-01-01T23:59:59.000Z

419

Economic impacts and challenges of China’s petroleum industry: An input–output analysis  

Science Journals Connector (OSTI)

It is generally acknowledged that the petroleum industry plays an important role in China’s national economic and social development. The direct, indirect, and induced impacts of China’s petroleum industry are analyzed in this study by using the Input–Output approach. The study also considers the main challenges that China’s economy might face in the future. The research results suggest the following: (1) The total economic impacts coefficients on output, given each unit of final demands change in extraction of petroleum and processing of petroleum, are 1.9180 and 3.2747 respectively, and the corresponding economic impacts coefficients on GDP are 1.0872 and 0.9001 respectively; (2) Extraction of petroleum has a more direct impact on GDP, while processing of petroleum has a greater effect on the total output; (3) Extraction of petroleum’s total economic impacts coefficients on both output and GDP have remained stable in recent years after a period of long decline; processing of petroleum’s total economic impacts coefficient on output is steadily increasing; (4) Import uncertainty, the likelihood of rising oil prices, and net oil exports caused by items manufactured with petroleum products (i.e. “Made in China” goods) are the main challenges the petroleum industry will cause for China’s overall economy.

Tang Xu; Zhang Baosheng; Feng Lianyong; Marwan Masri; Afshin Honarvar

2011-01-01T23:59:59.000Z

420

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

4. Existing Capacity by Producer Type, 2012 (Megawatts) 4. Existing Capacity by Producer Type, 2012 (Megawatts) Producer Type Number of Generators Generator Nameplate Capacity Net Summer Capacity Net Winter Capacity Electric Power Sector Electric Utilities 9,624 680,592 621,785 644,358 Independent Power Producers, Non-Combined Heat and Power Plants 6,148 412,045 374,964 389,349 Independent Power Producers, Combined Heat and Power Plants 609 39,916 35,266 38,023 Total 16,381 1,132,554 1,032,015 1,071,729 Commercial and Industrial Sectors Commercial Sector 962 3,610 3,223 3,349 Industrial Sector 1,680 31,832 27,795 29,381 Total 2,642 35,442 31,018 32,730 All Sectors Total 19,023 1,167,995 1,063,033 1,104,459 Notes: In 2011, EIA corrected the NAICS codes of several plants which resulted in a net capacity shift from the electric utility sector to the commercial sector.

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. U.S. Transformer Sustained Automatic Outage Counts B. U.S. Transformer Sustained Automatic Outage Counts and Hours by High-Voltage Size and NERC Region, 2012 Sustained Automatic Outage Counts High-Side Voltage (kV) Eastern Interconnection TRE WECC Contiguous U.S. 100-199 -- -- -- -- 200-299 -- -- 1.00 1.00 300-399 2.00 -- 4.00 6.00 400-599 14.00 -- 11.00 25.00 600+ -- -- -- -- Grand Total 16.00 -- 16.00 32.00 Sustained Automatic Outage Hours High-Side Voltage (kV) Eastern Interconnection TRE WECC Contiguous U.S. 100-199 -- -- -- -- 200-299 -- -- 27.58 27.58 300-399 153.25 -- 15.87 169.12 400-599 3,070.88 -- 258.37 3,329.25 600+ -- -- -- -- Grand Total 3,224.13 -- 301.82 3,525.95 Outage Hours per Outage Incident Eastern Interconnection TRE WECC Contiguous U.S.

422

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

6. Coal Consumption at Commercial and Institutional Users by Census Division and State" 6. Coal Consumption at Commercial and Institutional Users by Census Division and State" "(thousand short tons)" ,,,,"Year to Date" "Census Division","April - June","January - March","April - June",2013,2012,"Percent" "and State",2013,2013,2012,,,"Change" "Middle Atlantic",20,52,24,73,83,-12.4 " Pennsylvania",20,52,24,73,83,-12.4 "East North Central",112,197,127,309,331,-6.8 " Illinois",34,45,29,79,66,18.9 " Indiana","w","w","w","w","w","w" " Michigan","w","w","w","w","w","w"

423

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Number of Employees at Underground and Surface Mines by State and Mine Production Range, 2012" Number of Employees at Underground and Surface Mines by State and Mine Production Range, 2012" ,"Mine Production Range (thousand short tons)" "Coal-Producing State, Region1","Above 1,000","Above 500","Above 200","Above 100","Above 50","Above 10","Above 0","Zero2","Total Number" "and Mine Type",,"to 1,000","to 500","to 200","to 100","to 50","to 10",,"of Employees" "Alabama",3415,97,655,317,160,224,54,105,5041 " Underground",2981,"-","-","-",36,88,"-",81,3190 " Surface",434,97,655,317,124,136,54,24,1851

424

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

8. Average Sales Price of Coal by State and Mine Type, 2012 and 2011" 8. Average Sales Price of Coal by State and Mine Type, 2012 and 2011" "(dollars per short ton)" ,2012,,,2011,,,"Percent Change" "Coal-Producing","Underground","Surface","Total","Underground","Surface","Total","Underground","Surface","Total" "State" "Alabama",107.73,104.51,106.57,100.17,108.71,102.69,7.6,-3.9,3.8 "Alaska","-","w","w","-","w","w","-","w","w" "Arizona","-","w","w","-","w","w","-","w","w" "Arkansas","w","-","w","w","-","w","w","-","w"

425

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Coal Production by State and Mining Method, 2012" Underground Coal Production by State and Mining Method, 2012" "(thousand short tons)" "Coal-Producing State and Region1","Continuous2","Conventional and","Longwall4","Total" ,,"Other3" "Alabama",139,20,12410,12570 "Arkansas",96,"-","-",96 "Colorado",757,"-",22889,23646 "Illinois",18969,"-",23868,42837 "Indiana",15565,"-","-",15565 "Kentucky Total",56179,2018,"-",58198 " Kentucky (East)",22090,2010,"-",24100 " Kentucky (West)",34089,9,"-",34098 "Maryland",797,"-","-",797 "Montana","-","-",5708,5708

426

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Coal Mining Productivity by State, Mine Type, and Union Status, 2012" Coal Mining Productivity by State, Mine Type, and Union Status, 2012" "(short tons produced per employee hour)" ,"Union",,"Nonunion" "Coal-Producing State and Region1","Underground","Surface","Underground","Surface" "Alabama",1.69,"-",0.66,1.8 "Alaska","-",5.98,"-","-" "Arizona","-",7.38,"-","-" "Arkansas","-","-",0.59,"-" "Colorado",4.9,6.09,6.02,4.45 "Illinois",2.09,"-",5.34,4.7 "Indiana","-","-",3.23,5.41 "Kentucky Total",3.02,2.45,2.36,3.06 " Kentucky (East)","-",2.45,1.64,2.65

427

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Average Sales Price of U.S. Coal by State and Disposition, 2012" Average Sales Price of U.S. Coal by State and Disposition, 2012" "(dollars per short ton)" "Coal-Producing State","Open Market1","Captive2","Total3" "Alabama",85.06,"-",106.57 "Alaska","w","-","w" "Arizona","w","-","w" "Arkansas","w","-","w" "Colorado",38.51,43.19,37.54 "Illinois",49.04,54.71,53.08 "Indiana",49.16,54.5,52.01 "Kentucky Total",61.85,73.08,63.12 " Kentucky (East)",75.8,73.08,75.62 " Kentucky (West)",48.6,"-",48.67 "Louisiana","w","-","w"

428

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

5. Emissions from Energy Consumption at 5. Emissions from Energy Consumption at Conventional Power Plants and Combined-Heat-and-Power Plants, by State, 2011 and 2012 (Thousand Metric Tons) Census Division and State Carbon Dioxide (CO2) Sulfur Dioxide (SO2) Nitrogen Oxides (NOx) Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 New England 34,766 37,698 33 58 39 37 Connecticut 8,987 8,196 7 1 12 6 Maine 3,722 4,351 8 12 7 8 Massachusetts 14,346 16,404 15 22 14 14 New Hampshire 4,295 5,127 2 23 4 5 Rhode Island 3,403 3,595 0.03 0.07 2 3 Vermont 12 24 0.05 0.09 1 1 Middle Atlantic 161,786 171,603 275 370 187 203 New Jersey 16,120 16,917 4 5 14 13 New York 35,669 37,256 31 52 40 43 Pennsylvania 109,997 117,430 240 313 133 147

429

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Recoverable Coal Reserves and Average Recovery Percentage at Producing Mines by State, 2012 and 2011" Recoverable Coal Reserves and Average Recovery Percentage at Producing Mines by State, 2012 and 2011" "(million short tons)" ,2012,,2011 "Coal-Producing","Recoverable Coal","Average Recovery","Recoverable Coal","Average Recovery","Percent Change" "State","Reserves","Percentage","Reserves","Percentage","Recoverable Coal" ,,,,,"Reserves" "Alabama",265,53.63,306,55.39,-13.2 "Alaska","w","w","w","w","w" "Arizona","w","w","w","w","w" "Arkansas","w","w","w","w","w"

430

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

7. Average Retail Price of Electricity to Ultimate Customers: 7. Average Retail Price of Electricity to Ultimate Customers: Total by End-Use Sector, 2003 - December 2012 (Cents per Kilowatthour) Period Residential Commercial Industrial Transportation All Sectors Annual Totals 2003 8.72 8.03 5.11 7.54 7.44 2004 8.95 8.17 5.25 7.18 7.61 2005 9.45 8.67 5.73 8.57 8.14 2006 10.40 9.46 6.16 9.54 8.90 2007 10.65 9.65 6.39 9.70 9.13 2008 11.26 10.36 6.83 10.74 9.74 2009 11.51 10.17 6.81 10.65 9.82 2010 11.54 10.19 6.77 10.57 9.83 2011 11.72 10.23 6.82 10.46 9.90 2012 11.88 10.09 6.67 10.21 9.84 2010 January 10.49 9.55 6.50 10.17 9.28 February 10.89 9.89 6.55 10.48 9.47 March 11.11 9.95 6.53 10.28 9.48 April 11.71 9.95 6.55 10.52 9.53 May 11.91 10.15 6.64 10.52 9.72

431

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

1. Stocks of Coal, Petroleum Liquids, and Petroleum Coke: Electric Power Sector, 2002 - 2012 1. Stocks of Coal, Petroleum Liquids, and Petroleum Coke: Electric Power Sector, 2002 - 2012 Electric Power Sector Electric Utilities Independent Power Producers Period Coal (Thousand Tons) Petroluem Liquids (Thousand Barrels) Petroleum Coke (Thousand Tons) Coal (Thousand Tons) Petroluem Liquids (Thousand Barrels) Petroleum Coke (Thousand Tons) Coal (Thousand Tons) Petroluem Liquids (Thousand Barrels) Petroleum Coke (Thousand Tons) End of Year Stocks 2002 141,714 43,935 1,711 116,952 29,601 328 24,761 14,334 1,383 2003 121,567 45,752 1,484 97,831 28,062 378 23,736 17,691 1,105 2004 106,669 46,750 937 84,917 29,144 627 21,751 17,607 309 2005 101,137 47,414 530 77,457 29,532 374 23,680 17,882 156 2006 140,964 48,216 674 110,277 29,799 456 30,688 18,416 217

432

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Sales Price of Coal by State and Underground Mining Method, 2012" Sales Price of Coal by State and Underground Mining Method, 2012" "(dollars per short ton)" "Coal-Producing State","Continuous1","Conventional and","Longwall3","Total" ,,"Other2" "Alabama","w","-","w",107.73 "Arkansas","w","-","-","w" "Colorado","w","-",37.18,"w" "Illinois",48.08,"-",59.51,54.18 "Indiana",52.94,"-","-",52.94 "Kentucky Total","w","w","-",62.24 " Kentucky (East)","w","w","-",79.23 " Kentucky (West)",50.18,"-","-",50.18

433

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Steam Coal Exports by Customs District" Steam Coal Exports by Customs District" "(short tons)" ,,,,"Year to Date" "Customs District","April - June","January - March","April - June",2013,2012,"Percent" ,2013,2013,2012,,,"Change" "Eastern Total",4951041,5566950,6554494,10517991,11407664,-7.8 " Baltimore, MD",1275530,831976,1715016,2107506,2852092,-26.1 " Boston, MA",7,"-",12,7,24,-70.8 " Buffalo, NY",1180,1516,2826,2696,5257,-48.7 " New York City, NY",3088,2664,2168,5752,6106,-5.8 " Norfolk, VA",3578715,4697769,4760354,8276484,8443756,-2 " Ogdensburg, NY",36894,3610,3090,40504,6838,492.3 " Philadelphia, PA",55513,29255,34241,84768,56733,49.4

434

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

and Number of Mines by State, County, and Mine Type, 2012" and Number of Mines by State, County, and Mine Type, 2012" "(thousand short tons)" ,"Underground",,"Surface",,"Total" "Coal-Producing","Number of Mines","Production","Number of Mines","Production","Number of Mines","Production" "State and County" "Alabama",8,12570,38,6752,46,19321 " Bibb","-","-",2,119,2,119 " Blount","-","-",2,236,2,236 " Fayette",1,2249,"-","-",1,2249 " Franklin","-","-",2,137,2,137 " Jackson","-","-",3,152,3,152 " Jefferson",3,3589,9,1106,12,4695

435

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2. Average Tested Heat Rates by Prime Mover and Energy Source, 2007 - 2012 2. Average Tested Heat Rates by Prime Mover and Energy Source, 2007 - 2012 (Btu per Kilowatthour) Prime Mover Coal Petroluem Natural Gas Nuclear 2007 Steam Generator 10,158 10,398 10,440 10,489 Gas Turbine -- 13,217 11,632 -- Internal Combustion -- 10,447 10,175 -- Combined Cycle W 10,970 7,577 -- 2008 Steam Generator 10,138 10,356 10,377 10,452 Gas Turbine -- 13,311 11,576 -- Internal Combustion -- 10,427 9,975 -- Combined Cycle W 10,985 7,642 -- 2009 Steam Generator 10,150 10,349 10,427 10,459 Gas Turbine -- 13,326 11,560 -- Internal Combustion -- 10,428 9,958 -- Combined Cycle W 10,715 7,605 -- 2010 Steam Generator 10,142 10,249 10,416 10,452 Gas Turbine -- 13,386 11,590 -- Internal Combustion -- 10,429 9,917 --

436

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

0. Receipts, Average Cost, and Quality of Fossil Fuels: Commerical Sector, 2002 - 2012 (continued) 0. Receipts, Average Cost, and Quality of Fossil Fuels: Commerical Sector, 2002 - 2012 (continued) Petroleum Coke Natural Gas All Fossil Fuels Receipts Average Cost Receipts Average Cost Average Cost Period (Billion Btu) (Thousand Tons) (Dollars per MMbtu) (Dollars per Ton) Average Sulfur Percent by Weight Percentage of Consumption (Billion Btu) (Thousand Mcf) (Dollars per MMBtu) (Dollars per Mcf) Percentage of Consumption (Dollars per MMBtu) Annual Totals 2002 0 0 -- -- -- -- 18,671 18,256 3.44 3.52 24.7 3.03 2003 0 0 -- -- -- 0.0 18,169 17,827 4.96 5.06 30.5 4.02 2004 0 0 -- -- -- 0.0 16,176 15,804 5.93 6.07 21.9 4.58 2005 0 0 -- -- -- 0.0 17,600 17,142 8.38 8.60 25.2 6.25 2006 0 0 -- -- -- 0.0 21,369 20,819 8.33 8.55 30.7 6.42

437

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

3.A. Net Generation by Energy Source: Independent Power Producers, 2002 - 2012 3.A. Net Generation by Energy Source: Independent Power Producers, 2002 - 2012 (Thousand Megawatthours) Period Coal Petroleum Liquids Petroleum Coke Natural Gas Other Gas Nuclear Hydroelectric Conventional Renewable Sources Excluding Hydroelectric Hydroelectric Pumped Storage Other Total Annual Totals 2002 395,943 22,241 8,368 378,044 1,763 272,684 18,189 44,466 -1,309 8,612 1,149,001 2003 452,433 35,818 7,949 380,337 2,404 304,904 21,890 46,060 -1,003 8,088 1,258,879 2004 443,547 33,574 7,410 427,510 3,194 312,846 19,518 48,636 -962 7,856 1,303,129 2005 507,199 37,096 9,664 445,625 3,767 345,690 21,486 51,708 -1,174 6,285 1,427,346 2006 498,316 10,396 8,409 452,329 4,223 361,877 24,390 59,345 -1,277 6,412 1,424,421

438

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

9. Consumption of Coal for Electricity Generation by State by Sector, 9. Consumption of Coal for Electricity Generation by State by Sector, 2012 and 2011 (Thousand Tons) Electric Power Sector Census Division and State All Sectors Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Year 2012 Year 2011 Percentage Change Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 New England 1,787 2,998 -40% 520 898 1,257 2,087 0 0 10 12 Connecticut 297 317 -6.5% 0 0 297 317 0 0 0 0 Maine 11 14 -18% 0 0 6 7 0 0 5 6 Massachusetts 959 1,769 -46% 0 0 954 1,763 0 0 5 6 New Hampshire 520 898 -42% 520 898 0 0 0 0 0 0 Rhode Island 0 0 -- 0 0 0 0 0 0 0 0 Vermont 0 0 -- 0 0 0 0 0 0 0 0 Middle Atlantic 44,000 53,658 -18% 6 16 43,734 53,052 4 1 256 589

439

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

4. Average Retail Price of Electricity to Ultimate Customers 4. Average Retail Price of Electricity to Ultimate Customers by End-Use Sector 2002 through 2012 (Cents per kilowatthour) Year Residential Commercial Industrial Transportation Other Total Total Electric Industry 2002 8.44 7.89 4.88 N/A 6.75 7.20 2003 8.72 8.03 5.11 7.54 N/A 7.44 2004 8.95 8.17 5.25 7.18 N/A 7.61 2005 9.45 8.67 5.73 8.57 N/A 8.14 2006 10.40 9.46 6.16 9.54 N/A 8.90 2007 10.65 9.65 6.39 9.70 N/A 9.13 2008 11.26 10.36 6.83 10.74 N/A 9.74 2009 11.51 10.17 6.81 10.65 N/A 9.82 2010 11.54 10.19 6.77 10.57 N/A 9.83 2011 11.72 10.23 6.82 10.46 N/A 9.90 2012 11.88 10.09 6.67 10.21 N/A 9.84 Full-Service Providers 2002 8.40 7.77 4.78 N/A 6.65 7.13 2003 8.68 7.89 5.01 6.82 N/A 7.38

440

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Average Price of U.S. Steam Coal Exports" Average Price of U.S. Steam Coal Exports" "(dollars per short ton)" ,,,,"Year to Date" "Continent and Country","April - June","January - March","April - June",2013,2012,"Percent" "of Destination",2013,2013,2012,,,"Change" "North America Total",65.1,63.67,73.81,64.48,78.9,-18.3 " Canada*",59.34,55.22,63.02,57.57,73.63,-21.8 " Dominican Republic",78.47,74.41,73.89,75.4,76.61,-1.6 " Honduras","-",54.58,54.43,54.58,54.43,0.3 " Jamaica",480,54.43,"-",54.72,55.42,-1.3 " Mexico",69.42,73.33,82.64,70.83,86.44,-18.1 " Other**",80.33,389.3,70.37,82.45,76.1,8.3

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Coal Production by Coalbed Thickness and Mine Type, 2012" Coal Production by Coalbed Thickness and Mine Type, 2012" "(thousand short tons)" "Coal Thickness (inches)","Underground","Surface","Total" "Under 7","-",17,17 "7 - Under 13","-",2108,2108 "13 - Under 19",429,6688,7117 "19 - Under 25",111,14107,14217 "25 - Under 31",4147,12913,17060 "31 - Under 37",15128,19022,34150 "37 - Under 43",23868,17285,41153 "43 - Under 49",26035,15597,41632 "49 - Under 55",18909,22544,41453 "55 - Under 61",36946,11285,48231 "61 - Under 67",43146,15074,58220 "67 - Under 73",40983,8783,49766 "73 - Under 79",32914,10193,43107 "79 - Under 85",27011,3554,30565

442

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

3. Carbon Dioxide Uncontrolled Emission Factors 3. Carbon Dioxide Uncontrolled Emission Factors Fuel EIA Fuel Code Source and Tables (As Appropriate) Factor (Pounds of CO2 Per Million Btu)*** Bituminous Coal BIT Source: 1 205.30000 Distillate Fuel Oil DFO Source: 1 161.38600 Geothermal GEO Estimate from EIA, Office of Integrated Analysis and Forecasting 16.59983 Jet Fuel JF Source: 1 156.25800 Kerosene KER Source: 1 159.53500 Lignite Coal LIG Source: 1 215.40000 Municipal Solid Waste MSW Source: 1 (including footnote 2 within source) 91.90000 Natural Gas NG Source: 1 117.08000 Petroleum Coke PC Source: 1 225.13000 Propane Gas PG Sources: 1 139.17800 Residual Fuel Oil RFO Source: 1 173.90600 Synthetic Coal SC Assumed to have the emissions similar to Bituminous Coal. 205.30000

443

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Coal Imports by Customs District" Coal Imports by Customs District" "(short tons)" ,,,,"Year to Date" "Customs District","April - June","January - March","April - June",2013,2012,"Percent" ,2013,2013,2012,,,"Change" "Eastern Total",469878,331008,156004,800886,350124,128.7 " Baltimore, MD","-","-",106118,"-",154318,"-" " Boston, MA",373985,154438,"-",528423,51185,"NM" " Buffalo, NY",44,"-","-",44,"-","-" " New York City, NY",1373,1402,487,2775,507,447.3 " Norfolk, VA","-",68891,"-",68891,35856,92.1 " Ogdensburg, NY","-",1,12,1,12,-91.7

444

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

U.S. Coke Exports" U.S. Coke Exports" "(short tons)" ,,,,"Year to Date" "Continent and Country","April - June","January - March","April - June",2013,2012,"Percent" "of Destination",2013,2013,2012,,,"Change" "North America Total",162796,79217,201795,242013,340944,-29 " Canada*",73859,17837,112348,91696,161596,-43.3 " Mexico",88535,60517,86721,149052,176163,-15.4 " Other**",402,863,2726,1265,3185,-60.3 "South America Total",223,217,591,440,1158,-62 " Other**",223,217,591,440,1158,-62 "Europe Total",48972,59197,"-",108169,6,"NM" " Other**",347,11743,"-",12090,"-","-"

445

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

7. U.S. Coal Stocks, 2007 - 2013" 7. U.S. Coal Stocks, 2007 - 2013" "(thousand short tons)" ,"Coal Consumers" "Last Day of Quarter","Electric","Coke","Other","Commercial","Total","Coal Producers","Total" ,"Power","Plants","Industrial2","and",,"and" ,"Sector1",,,"Institutional Users",,"Distributors" 2007 " March 31",141389,2444,5756,"-",149588,34007,183595 " June 30",154812,2364,5672,"-",162849,32484,195333 " September 30",142666,1972,5811,"-",150448,30090,180538 " December 31",151221,1936,5624,"-",158781,33977,192758

446

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

5. Unit of Measure Equivalents 5. Unit of Measure Equivalents Unit Equivalent Kilowatt (kW) 1,000 (One Thousand) Watts Megawatt (MW) 1,000,000 (One Million) Watts Gigawatt (GW) 1,000,000,000 (One Billion) Watts Terawatt (TW) 1,000,000,000,000 (One Trillion) Watts Gigawatt 1,000,000 (One Million) Kilowatts Thousand Gigawatts 1,000,000,000 (One Billion) Kilowatts Kilowatthours (kWh) 1,000 (One Thousand) Watthours Megawatthours (MWh) 1,000,000 (One Million) Watthours Gigawatthours (GWh) 1,000,000,000 (One Billion) Watthours Terawatthours (TWh) 1,000,000,000,000 (One Trillion) Watthours Gigawatthours 1,000,000 (One Million) Kilowatthours Thousand Gigawatthours 1,000,000,000(One Billion Kilowatthours U.S. Dollar 1,000 (One Thousand) Mills U.S. Cent 10 (Ten) Mills Barrel of Oil 42 Gallons

447

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

6. Receipts, Average Cost, and Quality of Fossil Fuels: Electric Utilities, 2002 - 2012 (continued) 6. Receipts, Average Cost, and Quality of Fossil Fuels: Electric Utilities, 2002 - 2012 (continued) Petroleum Coke Natural Gas All Fossil Fuels Receipts Average Cost Receipts Average Cost Average Cost Period (Billion Btu) (Thousand Tons) (Dollars per MMbtu) (Dollars per Ton) Average Sulfur Percent by Weight Percentage of Consumption (Billion Btu) (Thousand Mcf) (Dollars per MMBtu) (Dollars per Mcf) Percentage of Consumption (Dollars per MMBtu) Annual Totals 2002 75,711 2,677 0.63 17.68 4.98 126.0 1,680,518 1,634,734 3.68 3.78 72.3 1.53 2003 89,618 3,165 0.74 20.94 5.51 124.0 1,486,088 1,439,513 5.59 5.77 81.6 1.74 2004 107,985 3,817 0.89 25.15 5.10 92.0 1,542,746 1,499,933 6.15 6.33 82.9 1.87 2005 102,450 3,632 1.29 36.31 5.16 87.9 1,835,221 1,780,721 8.32 8.57 83.4 2.38

448

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2 Stocks of Coal, Petroleum Liquids, and Petroleum Coke: 2 Stocks of Coal, Petroleum Liquids, and Petroleum Coke: Electric Power Sector, by State, 2012 and 2011 Census Division and State Coal (Thousand Tons) Petroleum Liquids (Thousand Barrels) Petroleum Coke (Thousand Tons) December 2012 December 2011 Percentage Change December 2012 December 2011 Percentage Change December 2012 December 2011 Percentage Change New England 1,030 1,389 -26% 2,483 2,680 -7.3% 0 0 -- Connecticut W W W 1,300 954 36% 0 0 -- Maine 0 0 -- W W W 0 0 -- Massachusetts W 675 W 837 990 -15% 0 0 -- New Hampshire W W W W W W 0 0 -- Rhode Island 0 0 -- W W W 0 0 -- Vermont 0 0 -- 51 49 3.0% 0 0 -- Middle Atlantic 7,553 7,800 -3.2% 5,496 6,591 -17% W W W New Jersey 926 871 6.3% 1,084 1,113 -2.6% 0 0 --

449

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

0. Coal Receipts at Commercial and Institutional Users by Census Division and State" 0. Coal Receipts at Commercial and Institutional Users by Census Division and State" "(thousand short tons)" ,,,,"Year to Date" "Census Division","April - June","January - March","April - June",2013,2012,"Percent" "and State",2013,2013,2012,,,"Change" "Middle Atlantic",25,54,32,79,90,-12 " Pennsylvania",25,54,32,79,90,-12 "East North Central",115,183,117,298,301,-0.9 " Illinois",31,42,28,73,67,8.1 " Indiana","w","w","w","w","w","w" " Michigan","w","w","w","w","w","w"

450

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Coal Receipts at Other Industrial Plants by Census Division and State" Coal Receipts at Other Industrial Plants by Census Division and State" "(thousand short tons)" ,,,,"Year to Date" "Census Division","April - June","January - March","April - June",2013,2012,"Percent" "and State",2013,2013,2012,,,"Change" "New England","w","w","w","w","w","w" " Maine","w","w","w","w","w","w" " Massachusetts","w","w","w","w","w","w" "Middle Atlantic",627,587,637,1214,1254,-3.1 " New York",214,178,194,392,377,4

451

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Major U.S. Coal Mines, 2012" Major U.S. Coal Mines, 2012" "Rank","Mine Name / Company","Mine Type","State","Production (short tons)" 1,"North Antelope Rochelle Mine / Peabody Powder River Mining Ll","Surface","Wyoming",107639188 2,"Black Thunder / Thunder Basin Coal Company Llc","Surface","Wyoming",93082919 3,"Cordero Mine / Cordero Mining Llc","Surface","Wyoming",39204736 4,"Antelope Coal Mine / Antelope Coal Llc","Surface","Wyoming",34316314 5,"Belle Ayr Mine / Alpha Coal West, Inc.","Surface","Wyoming",24227846 6,"Eagle Butte Mine / Alpha Coal West, Inc.","Surface","Wyoming",22466733

452

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

D. Petroleum Liquids: Consumption for Electricity Generation, D. Petroleum Liquids: Consumption for Electricity Generation, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 835,481 553,390 241,892 3,953 36,243 2003 1,089,307 658,868 380,378 5,358 44,702 2004 1,031,954 651,712 350,093 4,544 25,606 2005 1,035,045 618,811 387,355 3,469 25,410 2006 459,392 335,130 105,312 1,963 16,987 2007 512,423 355,999 139,977 1,505 14,942 2008 332,367 242,379 79,816 957 9,215 2009 266,508 196,346 59,277 1,101 9,784 2010 244,114 188,987 49,042 970 5,115 2011 163,954 125,755 33,166 801 4,233 2012 134,956 105,179 24,081 1,618 4,078 2010 January 33,737 26,715 6,282 100 639

453

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

9. Total Capacity of Distributed and Dispersed Generators by Technology Type, 9. Total Capacity of Distributed and Dispersed Generators by Technology Type, 2005 through 2012 Capacity (MW) Year Internal Combustion Combustion Turbine Steam Turbine Hydro Wind Photovoltaic Storage Other Wind and Other Total Number of Generators Distributed Generators 2005 4,025.0 1,917.0 1,830.0 999.0 -- -- -- -- 995.0 9,766.0 17,371 2006 3,646.0 1,298.0 2,582.0 806.0 -- -- -- -- 1,081.0 9,411.0 5,044 2007 4,624.0 1,990.0 3,596.0 1,051.0 -- -- -- -- 1,441.0 12,702.0 7,103 2008 5,112.0 1,949.0 3,060.0 1,154.0 -- -- -- -- 1,588.0 12,863.0 9,591 2009 4,339.0 4,147.0 4,621.0 1,166.0 -- -- -- -- 1,729.0 16,002.0 13,006 2010 886.8 186.0 109.9 97.4 98.9 236.3 -- 372.7 -- 1,988.0 15,630

454

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

D. Wood / Wood Waste Biomass: Consumption for Electricity Generation, D. Wood / Wood Waste Biomass: Consumption for Electricity Generation, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 605,054 10,659 129,947 469 463,980 2003 519,294 16,545 139,852 437 362,460 2004 344,134 19,973 130,248 168 193,745 2005 355,250 27,373 138,407 207 189,263 2006 350,074 27,455 135,546 269 186,803 2007 353,025 31,568 132,953 284 188,220 2008 338,786 29,150 130,122 287 179,227 2009 320,444 29,565 130,894 274 159,712 2010 349,530 40,167 137,072 274 172,016 2011 347,623 35,474 130,108 482 181,559 2012 390,342 32,723 138,217 478 218,924 2010 January 29,578 3,731 11,954 23 13,870

455

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

U.S. Coal Exports and Imports, 2007 - 2013" U.S. Coal Exports and Imports, 2007 - 2013" "(thousand short tons)" ,"January - March",,"April - June",,"July - September",,"October - December",,"Total" "Year","Exports","Imports","Exports","Imports","Exports","Imports","Exports","Imports","Exports","Imports" 2007,11139,8786,14702,8405,16198,10559,17124,8597,59163,36347 2008,15802,7640,23069,8982,20321,8485,22329,9101,81519,34208 2009,13335,6325,12951,5426,15159,5441,17653,5447,59097,22639 2010,17807,4803,21965,5058,21074,4680,20870,4811,81716,19353 2011,26617,3381,26987,3419,25976,3588,27679,2700,107259,13088 2012,28642,2022,37534,2329,31563,2415,28006,2394,125746,9159

456

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

1. Consumption of Petroleum Coke for Electricity Generation by State, by Sector, 1. Consumption of Petroleum Coke for Electricity Generation by State, by Sector, 2012 and 2011 (Thousand Tons) Electric Power Sector Census Division and State All Sectors Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Year 2012 Year 2011 Percentage Change Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 New England 0 0 -- 0 0 0 0 0 0 0 0 Connecticut 0 0 -- 0 0 0 0 0 0 0 0 Maine 0 0 -- 0 0 0 0 0 0 0 0 Massachusetts 0 0 -- 0 0 0 0 0 0 0 0 New Hampshire 0 0 -- 0 0 0 0 0 0 0 0 Rhode Island 0 0 -- 0 0 0 0 0 0 0 0 Vermont 0 0 -- 0 0 0 0 0 0 0 0 Middle Atlantic 56 121 -54% 0 0 0 94 0 0 56 27

457

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2. Nitrogen Oxides Uncontrolled Emission Factors 2. Nitrogen Oxides Uncontrolled Emission Factors Fuel, Code, Source and Emission Units Combustion System Type / Firing Configuration Cyclone Boiler Fluidized Bed Boiler Opposed Firing Boiler Spreader Stoker Boiler Fuel EIA Fuel Code Source and Tables (As Appropriate) Emissions Units Lbs = Pounds MMCF = Million Cubic Feet MG = Thousand Gallons Dry-Bottom Boilers Dry-Bottom Boilers Dry-Bottom Boilers Wet-Bottom Boilers Dry-Bottom Boilers Agricultural Byproducts AB Source: 1 Lbs per ton 1.20 1.20 1.20 N/A 1.20 Blast Furnace Gas BFG Sources: 1 (including footnote 7 within source); EIA estimates Lbs per MMCF 15.40 15.40 15.40 N/A 15.40 Bituminous Coal BIT Source: 2, Table 1.1-3 Lbs per ton 33.00 5.00 12.00 31.00 11.00 Black Liquor BLQ Source: 1 Lbs per ton ** 1.50 1.50 1.50 N/A 1.50

458

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2.1. Number of Ultimate Customers Served by Sector, by Provider, 2.1. Number of Ultimate Customers Served by Sector, by Provider, 2002 through 2012 Year Residential Commercial Industrial Transportation Other Total Total Electric Industry 2002 116,622,037 15,333,700 601,744 N/A 1,066,554 133,624,035 2003 117,280,481 16,549,519 713,221 1,127 N/A 134,544,348 2004 118,763,768 16,606,783 747,600 1,025 N/A 136,119,176 2005 120,760,839 16,871,940 733,862 518 N/A 138,367,159 2006 122,471,071 17,172,499 759,604 791 N/A 140,403,965 2007 123,949,916 17,377,219 793,767 750 N/A 142,121,652 2008 124,937,469 17,562,726 774,713 727 N/A 143,275,635 2009 125,177,175 17,561,661 757,519 705 N/A 143,497,060 2010 125,717,935 17,674,338 747,746 239 N/A 144,140,258 2011 126,143,072 17,638,062 727,920 92 N/A 144,509,146

459

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Average Price of U.S. Coke Exports" Average Price of U.S. Coke Exports" "(dollars per short ton)" ,,,,"Year to Date" "Continent and Country","April - June","January - March","April - June",2013,2012,"Percent" "of Destination",2013,2013,2012,,,"Change" "North America Total",240.59,241.38,218.4,240.85,225.8,6.7 " Canada*",147.49,330.47,243.04,183.08,286.56,-36.1 " Mexico",316.57,211.63,189.12,273.97,171.71,59.6 " Other**",612.42,485.63,134.48,525.92,135.04,289.5 "South America Total",140.65,156.15,322.7,148.29,250.36,-40.8 " Other**",140.65,156.15,322.7,148.29,250.36,-40.8 "Europe Total",259.26,255.24,"-",257.06,427.83,-39.9

460

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

A. Net Generation by Energy Source: Total (All Sectors), 2002 - 2012 A. Net Generation by Energy Source: Total (All Sectors), 2002 - 2012 (Thousand Megawatthours) Period Coal Petroleum Liquids Petroleum Coke Natural Gas Other Gas Nuclear Hydroelectric Conventional Renewable Sources Excluding Hydroelectric Hydroelectric Pumped Storage Other Total Annual Totals 2002 1,933,130 78,701 15,867 691,006 11,463 780,064 264,329 79,109 -8,743 13,527 3,858,452 2003 1,973,737 102,734 16,672 649,908 15,600 763,733 275,806 79,487 -8,535 14,045 3,883,185 2004 1,978,301 100,391 20,754 710,100 15,252 788,528 268,417 83,067 -8,488 14,232 3,970,555 2005 2,012,873 99,840 22,385 760,960 13,464 781,986 270,321 87,329 -6,558 12,821 4,055,423 2006 1,990,511 44,460 19,706 816,441 14,177 787,219 289,246 96,525 -6,558 12,974 4,064,702

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

8. Retail Sales of Electricity to Ultimate Customers by End-Use Sector, 8. Retail Sales of Electricity to Ultimate Customers by End-Use Sector, by State, 2012 and 2011 (Million Kilowatthours) Residential Commercial Industrial Transportation All Sectors Census Division and State Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 New England 47,208 47,481 44,864 45,018 27,818 27,927 566 569 120,456 120,995 Connecticut 12,758 12,919 12,976 13,087 3,566 3,668 193 185 29,492 29,859 Maine 4,481 4,382 4,053 4,018 3,027 3,016 0 0 11,561 11,415 Massachusetts 20,313 20,473 17,723 17,767 16,927 16,974 350 357 55,313 55,570 New Hampshire 4,439 4,454 4,478 4,478 1,953 1,936 0 0 10,870 10,869 Rhode Island 3,121 3,129 3,640 3,660 923 916 24 27 7,708 7,732

462

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

C. Net Summer Capacity of Utility Scale Units Using Primarily Fossil Fuels and by State, 2012 and 2011 (Megawatts) C. Net Summer Capacity of Utility Scale Units Using Primarily Fossil Fuels and by State, 2012 and 2011 (Megawatts) Census Division and State Natural Gas Fired Combined Cycle Natural Gas Fired Combustion Turbine Other Natural Gas Coal Petroleum Coke Petroleum Liquids Other Gases Total Fossil Fuels Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 New England 12,190.5 11,593.8 1,090.0 1,058.9 876.4 830.1 2,546.1 2,755.5 0.0 0.0 7,916.1 7,915.3 0.0 0.0 24,619.1 24,153.6 Connecticut 2,513.4 2,447.7 458.1 432.7 61.0 44.7 389.1 564.4 0.0 0.0 3,186.1 3,185.0 0.0 0.0 6,607.7 6,674.5 Maine 1,250.0 1,250.0 306.0 302.2 119.0 93.0 85.0 85.0 0.0 0.0 1,004.9 1,007.2 0.0 0.0 2,764.9 2,737.4

463

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

0. U.S. Coal Stocks at Manufacturing Plants by North American Industry Classification System (NAICS) Code" 0. U.S. Coal Stocks at Manufacturing Plants by North American Industry Classification System (NAICS) Code" "(thousand short tons)" "NAICS Code","June 30 2013","March 31 2013","June 30 2012","Percent Change" ,,,,"(June 30)" ,,,,"2013 versus 2012" "311 Food Manufacturing",875,926,1015,-13.9 "312 Beverage and Tobacco Product Mfg.",26,17,19,35.8 "313 Textile Mills",22,22,25,-13.9 "315 Apparel Manufacturing","w","w","w","w" "321 Wood Product Manufacturing","w","w","w","w" "322 Paper Manufacturing",570,583,743,-23.3 "324 Petroleum and Coal Products*",127,113,156,-18.7

464

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Recoverable Coal Reserves and Average Recovery Percentage at Producing U.S. Mines by Mine Production Range and Mine Type, 2012" Recoverable Coal Reserves and Average Recovery Percentage at Producing U.S. Mines by Mine Production Range and Mine Type, 2012" "(million short tons)" ,"Underground",,"Surface",,"Total" "Mine Production Range","Recoverable Coal","Average Recovery","Recoverable Coal","Average Recovery","Recoverable Coal","Average Recovery" "(thousand short tons)","Reserves","Percentage","Reserves","Percentage","Reserves","Percentage" "Over 1,000",4874,57.96,11153,91.28,16028,81.15 "Over 500 to 1,000",531,47.14,226,81.9,757,57.49 "Over 200 to 500",604,52.72,333,69.16,938,58.57

465

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

4. Receipts and Quality of Coal by Rank Delivered for Electricity Generation: 4. Receipts and Quality of Coal by Rank Delivered for Electricity Generation: Commercial Sector by State, 2012 Bituminous Subbituminous Lignite Census Division and State Receipts (Thousand Tons) Average Sulfur Percent by Weight Average Ash Percent by Weight Receipts (Thousand Tons) Average Sulfur Percent by Weight Average Ash Percent by Weight Receipts (Thousand Tons) Average Sulfur Percent by Weight Average Ash Percent by Weight New England 0 -- -- 0 -- -- 0 -- -- Connecticut 0 -- -- 0 -- -- 0 -- -- Maine 0 -- -- 0 -- -- 0 -- -- Massachusetts 0 -- -- 0 -- -- 0 -- -- New Hampshire 0 -- -- 0 -- -- 0 -- -- Rhode Island 0 -- -- 0 -- -- 0 -- -- Vermont 0 -- -- 0 -- -- 0 -- -- Middle Atlantic 0 -- -- 0 -- -- 0 -- --

466

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

8. Average Cost of Petroleum Liquids Delivered for Electricity Generation by State, 2012 and 2011 8. Average Cost of Petroleum Liquids Delivered for Electricity Generation by State, 2012 and 2011 (Dollars per MMBtu) Census Division and State Electric Power Sector Electric Utilities Independent Power Producers Year 2012 Year 2011 Percentage Change Year 2012 Year 2011 Year 2012 Year 2011 New England 18.64 W W 21.43 21.12 18.47 W Connecticut W 21.91 W 23.87 NM W 21.93 Maine W W W -- NM W W Massachusetts 17.17 19.76 -13% 17.45 NM 17.16 19.66 New Hampshire 23.23 W W 23.23 19.90 -- W Rhode Island -- W W -- NM -- W Vermont 24.11 NM NM 24.11 NM -- -- Middle Atlantic W 20.15 W 21.01 19.21 W 20.66 New Jersey 19.77 18.36 7.7% -- NM 19.77 20.28 New York W 19.66 W 21.01 20.00 W 19.36 Pennsylvania 21.84 22.19 -1.6% -- NM 21.84 22.19

467

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Productive Capacity of Coal Mines by State, 2012 and 2011" Productive Capacity of Coal Mines by State, 2012 and 2011" "(thousand short tons)" ,2012,,,2011,,,"Percent Change" "Coal-Producing","Underground","Surface","Total","Underground","Surface","Total","Underground","Surface","Total" "State" "Alabama",14594,7967,22561,16102,8911,25013,-9.4,-10.6,-9.8 "Alaska","-","w","w","-","w","w","-","w","w" "Arizona","-","w","w","-","w","w","-","w","w" "Arkansas","w","-","w","w","-","w","w","-","w"

468

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Quantity and Average Price of U.S. Coal Imports by Origin, 2007 - 2013" Quantity and Average Price of U.S. Coal Imports by Origin, 2007 - 2013" "(thousand short tons and dollars per short ton)" "Year and Quarter","Australia","Canada","Colombia","Indonesia","China","Venezuela","Other","Total" ,,,,,,,"Countries" 2007,66,1967,26864,3663,50,3425,311,36347 2008,149,2027,26262,3374,45,2312,39,34208 2009,152,1288,17787,2084,9,1297,21,22639 2010,380,1767,14584,1904,53,582,83,19353 2011,62,1680,9500,856,22,779,188,13088 2012 " January - March","-",260,1594,59,7,80,22,2022 " April - June","-",281,1728,49,21,170,80,2329 " July - September","-",297,1762,266,39,"-",51,2415

469

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Average Sales Price of Coal by State, County, and Number of Mines, 2012" Average Sales Price of Coal by State, County, and Number of Mines, 2012" "Coal-Producing State and County","Number of Mines","Sales","Average Sales Price" ,,"(thousand short tons)","(dollars per short ton)" "Alabama",39,19021,106.57 " Bibb",1,"w","w" " Blount",2,"w","w" " Fayette",1,"w","w" " Franklin",1,"w","w" " Jackson",2,"w","w" " Jefferson",11,4298,146.04 " Marion",1,"w","w" " Tuscaloosa",7,8599,111.55 " Walker",11,2370,81.88

470

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2. Coal Stocks at Commercial and Institutional Users by Census Division and State" 2. Coal Stocks at Commercial and Institutional Users by Census Division and State" "(thousand short tons)" "Census Division","June 30 2013","March 31 2013","June 30 2012","Percent Change" "and State",,,,"(June 30)" ,,,,"2013 versus 2012" "Middle Atlantic",62,58,56,10.9 " Pennsylvania",62,58,56,10.9 "East North Central",168,171,197,-14.7 " Illinois","w","w","w","w" " Indiana",75,76,75,0.5 " Michigan","w","w","w","w" " Ohio",25,15,19,27 " Wisconsin",5,5,3,59.1 "West North Central",66,75,97,-32.2

471

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

3. Summary Statistics for Coal Refining Plants, 2012 - 2013" 3. Summary Statistics for Coal Refining Plants, 2012 - 2013" "(thousand short tons)" "Year and","Coal Receipts","Average Price of Coal Receipts","Coal Used","Coal Stocks1" "Quarter",,"(dollars per short ton)" 2012 " January - March",2151,27.47,1756,771 " April - June",3844,25.42,3688,825 " July - September",5399,24.32,5286,812 " October - December",4919,24.55,4680,787 " Total",16313,25.06,15410 2013 " January - March",5067,24.6,4989,793 " April - June",4015,25.24,3754,756 " Total",9082,24.88,8744 "1 Reported as of the last day of the quarter." "Note: Average price is based on the cost, insurance, and freight (c.i.f. value). Total may not equal sum of components because of independent rounding."

472

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

3. Revenue and Expense Statistics for Major U.S. Investor-Owned Electric Utilities, 2002 through 2012 (Million Dollars) 3. Revenue and Expense Statistics for Major U.S. Investor-Owned Electric Utilities, 2002 through 2012 (Million Dollars) Description 2002 2003 2004 2005 2006 2007 Utility Operating Revenues 219,609 230,151 238,759 265,652 275,501 270,964 ......Electric Utility 200,360 206,268 213,012 234,909 246,736 240,864 ......Other Utility 19,250 23,883 25,747 30,743 28,765 30,100 Utility Operating Expenses 189,062 201,057 206,960 236,786 245,589 241,198 ......Electric Utility 171,604 179,044 183,121 207,830 218,445 213,076 ............Operation 116,660 125,436 131,560 150,645 158,893 153,885 ..................Production 90,715 98,305 103,871 120,586 127,494 121,700 ........................Cost of Fuel 24,149 26,871 28,544 36,106 37,945 39,548

473

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

U.S. Coke Imports" U.S. Coke Imports" "(short tons)" ,,,,"Year to Date" "Continent and Country","April - June","January - March","April - June",2013,2012,"Percent" "of Origin",2013,2013,2012,,,"Change" "North America Total",10284,2293,159462,12577,183712,-93.2 " Canada",3009,2293,159462,5302,183712,-97.1 " Panama",7275,"-","-",7275,"-","-" "South America Total",25267,13030,88424,38297,106612,-64.1 " Brazil","-","-",78595,"-",78595,"-" " Colombia",25267,13030,9829,38297,28017,36.7 "Europe Total",6044,40281,165027,46325,485791,-90.5

474

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Coal Production and Coalbed Thickness by Major Coalbeds and Mine Type, 2012" Coal Production and Coalbed Thickness by Major Coalbeds and Mine Type, 2012" ,"Production (thousand short tons)",,,"Thickness (inches)" "Coalbed ID Number1","Underground","Surface","Total","Average2","Low","High" "Coalbed Name" "1699 Wyodak","-",351188,351188,778,160,913 "0036 Pittsburgh",52476,3871,56348,74,18,138 "0489 No. 9",42193,12181,54374,61,24,74 "0484 Herrin (Illinois No. 6)",48526,1910,50436,71,46,89 "0212 Pittsburgh",27355,76,27431,75,27,98 "1701 Smith","-",23847,23847,822,745,912 "1696 Anderson-Dietz 1-Dietz 2","-",18992,18992,932,660,960

475

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

0. Average Retail Price of Electricity to Ultimate Customers by End-Use Sector, 0. Average Retail Price of Electricity to Ultimate Customers by End-Use Sector, by State, 2012 and 2011 (Cents per Kilowatthour) Residential Commercial Industrial Transportation All Sectors Census Division and State Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 New England 15.71 15.89 13.68 14.31 11.83 12.55 6.68 7.85 14.02 14.49 Connecticut 17.34 18.11 14.65 15.57 12.67 13.24 9.69 10.25 15.54 16.35 Maine 14.66 15.38 11.53 12.29 7.98 8.88 -- -- 11.81 12.58 Massachusetts 14.91 14.67 13.84 14.33 12.57 13.38 4.91 6.14 13.79 14.11 New Hampshire 16.07 16.52 13.36 14.04 11.83 12.27 -- -- 14.19 14.74 Rhode Island 14.40 14.33 11.87 12.37 10.68 11.27 8.28 14.11 12.74 13.04

476

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

3. Revenue from Retail Sales of Electricity to Ultimate Customers 3. Revenue from Retail Sales of Electricity to Ultimate Customers by Sector, by Provider, 2002 through 2012 (Million Dollars) Year Residential Commercial Industrial Transportation Other Total Total Electric Industry 2002 106,834 87,117 48,336 N/A 7,124 249,411 2003 111,249 96,263 51,741 514 N/A 259,767 2004 115,577 100,546 53,477 519 N/A 270,119 2005 128,393 110,522 58,445 643 N/A 298,003 2006 140,582 122,914 62,308 702 N/A 326,506 2007 148,295 128,903 65,712 792 N/A 343,703 2008 155,433 138,469 68,920 827 N/A 363,650 2009 157,008 132,940 62,504 828 N/A 353,280 2010 166,782 135,559 65,750 815 N/A 368,906 2011 166,714 135,926 67,606 803 N/A 371,049 2012 163,280 133,898 65,761 747 N/A 363,687

477

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

U.S. Metallurgical Coal Exports" U.S. Metallurgical Coal Exports" "(short tons)" ,,,,"Year to Date" "Continent and Country","April - June","January - March","April - June",2013,2012,"Percent" "of Destination",2013,2013,2012,,,"Change" "North America Total",1503162,764701,1411897,2267863,2261900,0.3 " Canada*",975783,343309,1260473,1319092,1895263,-30.4 " Dominican Republic",94,51064,"-",51158,"-","-" " Mexico",527285,370328,151424,897613,366637,144.8 "South America Total",2091488,2561772,2389018,4653260,4543747,2.4 " Argentina",104745,155806,203569,260551,253841,2.6 " Brazil",1921144,2352098,2185449,4273242,4022618,6.2

478

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

1. Average Price of Coal Receipts at Commercial and Institutional Users by Census Division and State" 1. Average Price of Coal Receipts at Commercial and Institutional Users by Census Division and State" "(dollars per short ton)" ,,,,"Year to Date" "Census Division","April - June","January - March","April - June",2013,2012,"Percent" "and State",2013,2013,2012,,,"Change" "Middle Atlantic",139.64,145,158.61,143.29,158.91,-9.8 " Pennsylvania",139.64,145,158.61,143.29,158.91,-9.8 "East North Central",87.62,97.3,87.11,93.56,95.13,-1.7 " Illinois",59.27,60.3,62.17,59.86,66.69,-10.2 " Indiana","w","w","w","w","w","w" " Michigan","w","w","w","w","w","w"

479

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Average Price of Coal Receipts at Other Industrial Plants by Census Division and State" Average Price of Coal Receipts at Other Industrial Plants by Census Division and State" "(dollars per short ton)" ,,,,"Year to Date" "Census Division","April - June","January - March","April - June",2013,2012,"Percent" "and State",2013,2013,2012,,,"Change" "New England","w","w","w","w","w","w" " Maine","w","w","w","w","w","w" " Massachusetts","w","w","w","w","w","w" "Middle Atlantic",87.05,93.03,93.73,89.93,95.68,-6 " New York",102.14,105.8,117.15,103.8,117.61,-11.7

480

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

8. Coal Stocks at Coke Plants by Census Division" 8. Coal Stocks at Coke Plants by Census Division" "(thousand short tons)" "Census Division","June 30 2013","March 31 2013","June 30 2012","Percent Change" ,,,,"(June 30)" ,,,,"2013 versus 2012" "Middle Atlantic","w","w","w","w" "East North Central",1313,1177,1326,-1 "South Atlantic","w","w","w","w" "East South Central","w","w","w","w" "U.S. Total",2500,2207,2295,8.9 "w = Data withheld to avoid disclosure." "Note: Total may not equal sum of components because of independent rounding."

Note: This page contains sample records for the topic "ac output efficiencies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

7 Receipts, Average Cost, and Quality of Fossil Fuels: Independent Power Producers, 2002 - 2012 7 Receipts, Average Cost, and Quality of Fossil Fuels: Independent Power Producers, 2002 - 2012 Coal Petroleum Liquids Receipts Average Cost Receipts Average Cost Period (Billion Btu) (Thousand Tons) (Dollars per MMBtu) (Dollars per Ton) Average Sulfur Percent by Weight Percentage of Consumption (Billion Btu) (Thousand Barrels) (Dollars per MMBtu) (Dollars per Barrel) Average Sulfur Percent by Weight Percentage of Consumption Annual Totals 2002 3,710,847 182,482 1.37 27.96 1.15 87.0 186,271 30,043 4.19 25.98 0.61 76.4 2003 4,365,996 223,984 1.34 26.20 1.15 90.4 347,546 56,138 5.41 33.50 0.58 89.7 2004 4,410,775 227,700 1.41 27.27 1.13 93.3 337,011 54,152 5.35 33.31 0.61 93.6 2005 4,459,333 229,071 1.56 30.39 1.10 83.0 381,871 61,753 8.30 51.34 0.54 97.2

482

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Metallurgical Coal Exports by Customs District" Metallurgical Coal Exports by Customs District" "(short tons)" ,,,,"Year to Date" "Customs District","April - June","January - March","April - June",2013,2012,"Percent" ,2013,2013,2012,,,"Change" "Eastern Total",11716074,14136513,15167377,25852587,27578514,-6.3 " Baltimore, MD",2736470,4225450,5123600,6961920,9037970,-23 " Boston, MA","-","-","-","-",28873,"-" " Buffalo, NY",247714,121347,524040,369061,725698,-49.1 " Norfolk, VA",8730257,9784866,9519119,18515123,17784479,4.1 " Ogdensburg, NY",1633,4850,618,6483,1494,333.9 "Southern Total",3551564,3824484,4264938,7376048,8976503,-17.8

483

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

3 Stocks of Coal, Petroleum Liquids, and Petroleum Coke: 3 Stocks of Coal, Petroleum Liquids, and Petroleum Coke: Electric Power Sector, by Census Divison, 2012 and 2011 Electric Power Sector Electric Utilities Independent Power Producers Census Division December 2012 December 2011 Percentage Change December 2012 December 2011 December 2012 December 2011 Coal (Thousand Tons) New England 1,030 1,389 -25.9% W W W W Middle Atlantic 7,553 7,800 -3.2% W W W W East North Central 36,139 37,262 -3.0% 27,069 27,316 9,070 9,946 West North Central 30,554 28,544 7.0% 30,554 28,544 0 0 South Atlantic 38,859 36,920 5.3% 35,527 33,163 3,331 3,757 East South Central 19,657 17,185 14.4% 19,657 17,185 0 0 West South Central 28,807 22,910 25.7% 17,047 15,125 11,760 7,785

484

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

D. Coal: Consumption for Electricity Generation, D. Coal: Consumption for Electricity Generation, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 19,996,890 15,517,857 4,215,043 9,168 254,821 2003 20,366,879 15,391,188 4,745,545 13,080 217,066 2004 20,375,751 15,610,335 4,606,584 8,251 150,581 2005 20,801,716 15,397,688 5,250,824 8,314 144,889 2006 20,527,410 15,211,077 5,166,001 7,526 142,807 2007 20,841,871 15,436,110 5,287,202 7,833 110,727 2008 20,548,610 15,189,050 5,242,194 8,070 109,296 2009 18,240,611 13,744,178 4,390,596 7,007 98,829 2010 19,196,315 14,333,496 4,709,686 6,815 146,318 2011 18,074,298 13,551,416 4,399,144 7,263 116,475

485

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

A. Net Generation by Energy Source: Electric Utilities, 2002 - 2012 A. Net Generation by Energy Source: Electric Utilities, 2002 - 2012 (Thousand Megawatthours) Period Coal Petroleum Liquids Petroleum Coke Natural Gas Other Gas Nuclear Hydroelectric Conventional Renewable Sources Excluding Hydroelectric Hydroelectric Pumped Storage Other Total Annual Totals 2002 1,514,670 52,838 6,286 229,639 206 507,380 242,302 3,089 -7,434 480 2,549,457 2003 1,500,281 62,774 7,156 186,967 243 458,829 249,622 3,421 -7,532 519 2,462,281 2004 1,513,641 62,196 11,498 199,662 374 475,682 245,546 3,692 -7,526 467 2,505,231 2005 1,484,855 58,572 11,150 238,204 10 436,296 245,553 4,945 -5,383 643 2,474,846 2006 1,471,421 31,269 9,634 282,088 30 425,341 261,864 6,588 -5,281 700 2,483,656

486

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

10.6. Advanced Metering Count by Technology Type, 10.6. Advanced Metering Count by Technology Type, 2007 through 2012 Year Residential Commercial Industrial Transportation Total Automated Meter Reading (AMR) 2007 25,785,782 2,322,329 44,015 109 28,152,235 2008 36,425,943 3,529,985 77,122 13 40,033,063 2009 41,462,111 4,239,531 107,033 11 45,808,686 2010 43,913,225 4,611,877 159,315 626 48,685,043 2011 41,451,888 4,341,105 172,692 77 45,965,762 2012 43,455,437 4,691,018 185,862 125 48,330,822 Advanced Metering Infrastructure (AMI) 2007 2,202,222 262,159 9,106 2 2,473,489 2008 4,190,244 444,003 12,757 12 4,647,016 2009 8,712,297 876,419 22,675 10 9,611,401 2010 18,369,908 1,904,983 59,567 67 20,334,525 2011 33,453,548 3,682,159 154,659 7 37,290,373

487

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

0. Net Metering Customers and Capacity by Technology Type, by End Use Sector, 0. Net Metering Customers and Capacity by Technology Type, by End Use Sector, 2003 through 2012 Capacity (MW) Customers Year Residential Commercial Industrial Transportation Total Residential Commercial Industrial Transportation Total Historical Data 2003 N/A N/A N/A N/A N/A 5,870 775 168 -- 6,813 2004 N/A N/A N/A N/A N/A 14,114 1,494 215 3 15,826 2005 N/A N/A N/A N/A N/A 19,244 1,565 337 -- 21,146 2006 N/A N/A N/A N/A N/A 30,689 2,553 376 -- 33,618 2007 N/A N/A N/A N/A N/A 44,450 3,513 391 -- 48,354 2008 N/A N/A N/A N/A N/A 64,400 5,305 304 -- 70,009 2009 N/A N/A N/A N/A N/A 88,205 7,365 919 -- 96,489 Photovoltaic 2010 697.890 517.861 243.051 -- 1,458.802 137,618 11,897 1,225 -- 150,740

488

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2. Summary Statistics for the United States, 2002 - 2012 2. Summary Statistics for the United States, 2002 - 2012 (From Table 2.1.) Number of Ultimate Customers Year Residential Commercial Industrial Transportation Other Total 2002 116,622,037 15,333,700 601,744 N/A 1,066,554 133,624,035 2003 117,280,481 16,549,519 713,221 1,127 N/A 134,544,348 2004 118,763,768 16,606,783 747,600 1,025 N/A 136,119,176 2005 120,760,839 16,871,940 733,862 518 N/A 138,367,159 2006 122,471,071 17,172,499 759,604 791 N/A 140,403,965 2007 123,949,916 17,377,219 793,767 750 N/A 142,121,652 2008 124,937,469 17,562,726 774,713 727 N/A 143,275,635 2009 125,177,175 17,561,661 757,519 705 N/A 143,497,060 2010 125,717,935 17,674,338 747,746 239 N/A 144,140,258 2011 126,143,072 17,638,062 727,920 92 N/A 144,509,146

489

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Coal Disposition by State, 2012" Coal Disposition by State, 2012" "(thousand short tons)" "Coal-Producing State","Open Market Sales1","Captive Sales / Transactions2","Exports3","Total" "Alabama",8688,"-",10333,19021 "Alaska","w","-",968,"w" "Arizona","w","-","-","w" "Arkansas","w","-","-","w" "Colorado",20836,4552,3468,28856 "Illinois",29252,5113,12341,46705 "Indiana",17127,18404,375,35906 "Kentucky Total",76602,6884,5668,89154 " Kentucky (East)",37324,6884,3588,47796 " Kentucky (West)",39277,"-",2081,41358

490

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

A. Natural Gas: Consumption for Electricity Generation, A. Natural Gas: Consumption for Electricity Generation, by Sector, 2002 - 2012 (Million Cubic Feet) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2002 6,126,062 2,259,684 3,148,595 32,545 685,239 2003 5,616,135 1,763,764 3,145,485 38,480 668,407 2004 5,674,580 1,809,443 3,265,896 32,839 566,401 2005 6,036,370 2,134,859 3,349,921 33,785 517,805 2006 6,461,615 2,478,396 3,412,826 34,623 535,770 2007 7,089,342 2,736,418 3,765,194 34,087 553,643 2008 6,895,843 2,730,134 3,612,197 33,403 520,109 2009 7,121,069 2,911,279 3,655,712 34,279 519,799 2010 7,680,185 3,290,993 3,794,423 39,462 555,307 2011 7,883,865 3,446,087 3,819,107 47,170 571,501

491

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2. Consumption of Nautral Gas for Electricity Generation by State, by Sector, 2. Consumption of Nautral Gas for Electricity Generation by State, by Sector, 2012 and 2011 (Million Cubic Feet) Electric Power Sector Census Division and State All Sectors Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Year 2012 Year 2011 Percentage Change Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 New England 460,887 461,590 -0.2% 3,652 4,218 428,781 432,350 8,630 6,287 19,824 18,735 Connecticut 120,380 110,546 8.9% 69 730 113,620 105,965 3,952 2,061 2,739 1,790 Maine 44,424 49,352 -10% 0 0 28,456 33,555 307 12 15,662 15,785 Massachusetts 184,330 190,063 -3.0% 2,792 2,393 176,497 182,865 3,749 3,761 1,293 1,045 New Hampshire 50,678 46,927 8.0% 754 1,046 49,655 45,765 139 0 131 115

492

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

D. Other Waste Biomass: Consumption for Electricity Generation, D. Other Waste Biomass: Consumption for Electricity Generation, by Sector, 2002 - 2012 (Billion Btus) Electric Power Sector Period Total (all sectors) Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Annual Totals 2003 34,775 2,456 15,859 4,566 11,894 2004 19,215 2,014 9,240 4,308 3,654 2005 17,852 2,485 7,365 4,677 3,325 2006 17,727 2,611 7,788 4,436 2,893 2007 19,083 2,992 8,861 4,049 3,181 2008 24,288 3,409 12,745 3,684 4,450 2009 24,847 3,679 13,231 3,760 4,177 2010 29,996 3,668 14,449 3,790 8,090 2011 30,771 4,488 16,115 3,816 6,352 2012 30,342 4,191 15,740 4,016 6,395 2010 January 2,223 189 1,078 321 635 February 2,336 275 1,208 291 561 March 2,287 311 1,079 302 594

493

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

1. U.S. Coal Summary Statistics, 2007 - 2013" 1. U.S. Coal Summary Statistics, 2007 - 2013" "(thousand short tons)" "Year and","Production1","Imports","Waste Coal","Producer and","Consumption","Exports","Consumer","Losses and" "Quarter",,,"Supplied","Distributor",,,"Stocks2","Unaccounted" ,,,,"Stocks2",,,,"For3" 2007 " January - March",286041,8786,3264,34007,278727,11139,149588 " April - June",285687,8405,3387,32484,267106,14702,162849 " July - September",286035,10559,3697,30090,303665,16198,150448 " October - December",288872,8597,3727,33977,278500,17124,158781 " Total",1146635,36347,14076,,1127998,59163,,4085

494

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

1. Receipts, Average Cost, and Quality of Fossil Fuels: Industrial Sector, 2002 - 2012 1. Receipts, Average Cost, and Quality of Fossil Fuels: Industrial Sector, 2002 - 2012 Coal Petroleum Liquids Receipts Average Cost Receipts Average Cost Period (Billion Btu) (Thousand Tons) (Dollars per MMBtu) (Dollars per Ton) Average Sulfur Percent by Weight Percentage of Consumption (Billion Btu) (Thousand Barrels) (Dollars per MMBtu) (Dollars per Barrel) Average Sulfur Percent by Weight Percentage of Consumption Annual Totals 2002 294,234 13,659 1.45 31.29 1.56 52.1 29,137 4,638 3.55 22.33 1.24 26.5 2003 322,547 15,076 1.45 31.01 1.37 60.7 27,538 4,624 4.85 28.86 1.25 23.2 2004 326,495 15,324 1.63 34.79 1.43 57.6 25,491 4,107 4.98 30.93 1.38 18.5 2005 339,968 16,011 1.94 41.17 1.42 61.9 36,383 5,876 6.64 41.13 1.36 26.4

495

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

2. Receipts and Quality of Coal by Rank Delivered for Electricity Generation: Electric Utilties by State, 2012 2. Receipts and Quality of Coal by Rank Delivered for Electricity Generation: Electric Utilties by State, 2012 Bituminous Subbituminous Lignite Census Division and State Receipts (Thousand Tons) Average Sulfur Percent by Weight Average Ash Percent by Weight Receipts (Thousand Tons) Average Sulfur Percent by Weight Average Ash Percent by Weight Receipts (Thousand Tons) Average Sulfur Percent by Weight Average Ash Percent by Weight New England 353 2.20 7.7 0 -- -- 0 -- -- Connecticut 0 -- -- 0 -- -- 0 -- -- Maine 0 -- -- 0 -- -- 0 -- -- Massachusetts 0 -- -- 0 -- -- 0 -- -- New Hampshire 353 2.20 7.7 0 -- -- 0 -- -- Rhode Island 0 -- -- 0 -- -- 0 -- -- Vermont 0 -- -- 0 -- -- 0 -- --

496

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

Productive Capacity and Capacity Utilization of Underground Coal Mines by State and Mining Method, 2012" Productive Capacity and Capacity Utilization of Underground Coal Mines by State and Mining Method, 2012" "(thousand short tons)" ,"Continuous1",,"Conventional and Other2",,"Longwall3",,"Total" "Coal-Producing","Productive","Capacity","Productive","Capacity","Productive","Capacity","Productive","Capacity" "State","Capacity","Utilization","Capacity","Utilization","Capacity","Utilization","Capacity","Utilization" ,,"Percent",,"Percent",,"Percent",,"Percent" "Alabama","w","w","-","-","w","w",14594,85.99

497

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

6. Receipts of Natural Gas Delivered for Electricity Generation by State, 2012 and 2011 6. Receipts of Natural Gas Delivered for Electricity Generation by State, 2012 and 2011 (Million Cubic Feet) Electric Power Sector Census Division and State All Sectors Electric Utilities Independent Power Producers Commercial Sector Industrial Sector Year 2012 Year 2011 Percentage Change Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 Year 2012 Year 2011 New England 440,421 484,260 -9.1% 3,652 4,226 419,062 434,504 3,636 13,156 14,072 32,373 Connecticut 112,084 116,563 -3.8% 71 738 112,012 107,121 0 3,210 0 5,494 Maine 42,374 56,230 -25% 0 0 28,302 33,578 0 NM 14,072 22,639 Massachusetts 175,314 198,295 -12% 2,789 2,393 168,890 184,156 3,636 7,872 0 3,875 New Hampshire 50,408 47,137 6.9% 754 1,046 49,655 45,725 0 0 0 NM

498

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Winter Net Internal Demand, Capacity Resources, and Capacity Margins B. Winter Net Internal Demand, Capacity Resources, and Capacity Margins by North American Electric Reliability Corporation Assessment Area, 2012 Actual, 2013-2017 Projected Net Internal Demand (Megawatts) -- Winter Eastern Interconnection ERCOT Western Interconnection All Interconnections Period FRCC NPCC Balance of Eastern Region MAPP MISO PJM SERC SPP TRE WECC Contiguous U.S. Actual 2012 / 2013 36,409 45,545 386,359 4,925 74,430 122,566 149,359 35,079 46,909 101,706 616,927 Projected 2013 / 2014 43,384 46,008 399,149 5,385 75,320 132,229 145,657 40,558 51,435 107,341 647,317 Projected 2014 / 2015 44,060 46,090 403,883 5,500 76,252 134,742 146,130 41,259 53,742 109,418 657,192 Projected 2015 / 2016 44,596 46,184 408,927 5,563 77,058 137,338 147,201 41,767 55,346 110,814 665,866

499

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

B. Noncoincident Peak Load by North American Electric Reliability Corporation Assessment Area, B. Noncoincident Peak Load by North American Electric Reliability Corporation Assessment Area, 2012 Actual, 2013-2017 Projected Summer Peak Load (Megawatts) Eastern Interconnection ERCOT Western Interconnection All Interconnections Period FRCC NPCC Balance of Eastern Region MAPP MISO PJM SERC SPP TRE WECC Contiguous U.S. Actual 2012 44,338 58,319 468,092 5,051 96,769 154,339 161,687 50,246 66,548 130,465 767,762 Projected 2013 45,668 59,969 469,857 5,109 96,192 155,553 159,032 53,971 67,998 133,523 777,015 Projected 2014 46,338 60,654 475,005 5,249 96,879 158,717 159,457 54,703 69,289 132,731 784,017 Projected 2015 47,053 61,428 484,637 5,360 97,565 162,216 164,150 55,346 71,423 134,183 798,724

500

SAS Output  

U.S. Energy Information Administration (EIA) Indexed Site

3. Coal Mining Productivity by State, Mine Type, and Mine Production Range, 2012" 3. Coal Mining Productivity by State, Mine Type, and Mine Production Range, 2012" "(short tons produced per employee hour)" ,"Mine Production Range (thousand short tons)" "Coal-Producing State, Region1","Above 1,000","Above 500","Above 200","Above 100","Above 50","Above 10","10 or Under","Total2" "and Mine Type",,"to 1,000","to 500","to 200","to 100","to 50" "Alabama",1.69,2.5,1.95,1.72,1.83,0.69,0.55,1.68 " Underground",1.73,"-","-","-",1.08,0.31,"-",1.64 " Surface",1.36,2.5,1.95,1.72,2.11,1.19,0.55,1.75