Powered by Deep Web Technologies
Note: This page contains sample records for the topic "230-kv pp-36 nelway" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

EA-1551: Montana Alberta Tie Ltd. (MATL) 230-KV Transmission Line  

Broader source: Energy.gov [DOE]

DOE started to prepare, jointly with the Montana Department of Environmental Quality (MDEQ), an EA that would also serve as a state EIS. The document would evaluate the potential environmental impacts of a proposed international transmission line that would cross the U.S.-Canada border in northwest Montana. Based on comments received on the DOE Draft EA/MDEQ Draft EIS, DOE cancelled preparation of the EA and announced preparation of DOE/EIS-0399 (of the same title).

2

EIS-0399: Montana Alberta Tie Ltd. (MATL) 230-KV Transmission Line  

Broader source: Energy.gov [DOE]

DOE, jointly with the Montana Department of Environmental Quality (MDEQ), prepared an EIS that evaluated the potential environmental impacts of a proposed international transmission line that would cross the U.S.-Canada border in northwest Montana.

3

PP-36 Bonneville Power Administration | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNG |September 15, 2010Energy6 Frontera Generation Limited15 Trico Electric

4

Etching of Copper Coated Mylar Tubes With CF-4 Gas  

DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

Using 5 mm diameter copper coated mylar straw tubes at a potential of 2.30 KV relative to a concentric 20 (mu)m diameter gold-plated tungsten anode, it has been observed that with very low flow rates of CF4-based gases the conductive copper cathode material may be removed entirely from the mylar surface.

Ecklund, Karl M.; Hartman, Keith W.; Hebert, Michael J.; Wojcicki, Stanley G.

1996-04-01T23:59:59.000Z

5

Using a Cognitive Theoretical Framework to Support Accident Analysis  

E-Print Network [OSTI]

Busse,D.K Johnson,C.W. The Second Workshop on Human Error, Safety and Systems Development pp 36-44 Safeware Engineering Corp

Busse, D.K Johnson, C.W.

6

SUMMER TRAINING REPORT KING FAHD UNIVERSITY OF PETROLEUM &  

E-Print Network [OSTI]

points (B.S.P.) and Grid Stations. The Grid Station receives 69KV and steps it down to 13.8 KV by providing a standard voltage of 13.8 KV. After that, the 13.8 KV is converted to 230 KV and 380 KV using for their switchgears. The Engineering Division deals with the distribution of substations and mini pillars among a new

Al-Ghadhban, Samir

7

Improved lower bounds for solving the minimal open stacks problem  

E-Print Network [OSTI]

Miller,A. Proceedings of the constraint modelling challenge, in conjuction with the fifth workshop on modelling and solving problems with constraints held at IJCAI'05, Edinburgh UK, July 2005. pp 36--43

Miller, A.

8

EIS-0433: Keystone XL Pipeline  

Broader source: Energy.gov [DOE]

The proposed Keystone XL project consists of a 1,700-mile crude oil pipeline and related facilities that would primarily be used to transport Western Canadian Sedimentary Basin crude oil from an oil supply hub in Alberta, Canada to delivery points in Oklahoma and Texas. This EIS, prepared by the Department of State, evaluates the environmental impacts of the proposed Keystone XL project. DOEs Western Area Power Administration, a cooperating agency, has jurisdiction over certain proposed transmission facilities (construction and operation of a short 230-kv transmission line and construction of a new substation). The State Department published a notice in the Federal Register on February 3, 2012, regarding the denial of the Keystone XL presidential permit (77 FR 5614).

9

Transactions of the Institute of Measurement and Control 25,1 (2003) pp. 3656 Pre-emptive control of moisture  

E-Print Network [OSTI]

to improve quality and reduce cost is high. The two key quality measures in paper manufacturing are: (1 on this measurement, steam pressures in the thermal dryer cans are adjusted via a variety of possible controlTransactions of the Institute of Measurement and Control 25,1 (2003) pp. 36­56 Pre-emptive control

Li, Perry Y.

10

An industrial hygiene survey of acetonitrile using a miniature quadrupole mass spectrometer  

E-Print Network [OSTI]

to Life or Health Concentrations. Cincinnati, OH: NIOSH, 1995. 6. National Institute of Occupational Safety and Health (NIOSH): Acetonitrile (Analytical Method 1606). In NlOSH Manual of Analytical Methods, 4th ed. , P. M. Eller (ed. ). Cincinnati, OH... of Occupational Safety and Health (NIOSH): Development aud Evaluation of Methods. Iu ?1OSH Manual of Analytical Methods, 4' ed. , PM. Eller (cd. ). Cincinnati, OH: NIOSH, 1994. pp. 36-44 13. Einfeld, W. , S. F. Bender, M. R. Keenan, S. M. Thornberg, and M. M...

Bruss, Stacy M

1999-01-01T23:59:59.000Z

11

Part 16, Authors: T To Tsykalas  

E-Print Network [OSTI]

pp. 36-39. [Wm.] 1905 d.?Ent?ro-p?ritonite vermineuse provo- qu?e l'Ascaris mystax, chez un chien [Abs- tract of 1905 c]

Humphrey, Judith M.; Hassall, Albert; Doss, Mildred A.

1952-01-01T23:59:59.000Z