
- Modeling of Load Transfer Behavior of AR-Glass-Rovings in Textile
- Test 1 : Standard Slump and Flow Table Tests To determine the reference slump value for Kistner concrete mix design and to calibrate it
- BENDING AND PUNCHING SHEAR STRENGTH OF FIBER-REINFORCED GLASS CONCRETE SLABS
- A composite material that consists essentially of a binding medium, such as a mixture of portland ce-
- Cracking an ASR Barrier By Christian Meyer, Columbia University
- Association of New York City Concrete Producers Spring/Summer 2002
- BENDING AND PUNCHING SHEAR STRENGTH OF FIBER-REINFORCED GLASS CONCRETE SLABS
- Meyer, Prestressed Thin Sheets, Page 1 of 12 Fax: (+1) 212 854 6267
- This paper outlines the social, legislative and technical reasons for recycling waste glass, with specific emphasis on its use in concrete as high-value decorative aggregate or cement
- Towards Prestressed Thin-Sheet Glass Concrete Products Gregor Vilkner and Christian Meyer
- Concrete Materials and Sustainable Development in the United States Christian Meyer
- Fatigue Life of Damaged Bridge Deck Panels Strengthened With Carbon Fiber Hongseob Oh, Jongsung Sim, and Christian Meyer
- Baustatik-Baupraxis 9, 2005, TU Dresden Hochleistungsfaserbeton Anwendungsmglichkeiten und
- Concrete as a Green Building Material Columbia University, New York, NY 10027, USA
- ACI Structural Journal/January-February 2008 87 ACI Structural Journal, V. 105, No. 1, January-February 2008.
- 302 ACI Materials Journal/May-June 2008 ACI MATERIALS JOURNAL TECHNICAL PAPER
- Hydration kinetics modeling of Portland cement considering the effects of curing temperature and applied pressure
- MODELING OF HYDRATION KINETICS AND SHRINKAGE OF PORTLAND CEMENT PASTE
- Int. Symposium on Recycling and Reuse of Glass Cullet 19-20 March, 2001
- Bulletin of the New York Concrete Industry Board
- BY CHRISTIAN MEYER AND MICHAEL H. SHEER Concrete international /OCTOBER 2005 43
- ORIGINAL PAPER Structural Assessment of Externally Strengthened
- A Mathematical Model for the Pessimum Size Effect of ASR in , C. Meyerc
- VILKNER, Glass Concrete with Carpet Fibers, 1/10 Fax: +1 212 854 7267
- Thermal Analyses Thermal Resistance of Precast Concrete Wall Panels with Concrete
- ARAMID FIBER MESH AS REINFORCEMENT OF CONCRETE PANELS SUBJECTED TO HIGH STRAIN RATES
- Glass Concrete Thin Sheets Reinforced with Prestressed Aramid Fabrics
- Sustainable Development and the Concrete Industry Christian Meyer
- Concrete and Sustainable Development Special Publication ACI 206, 2002
- ARAMID FIBER MESH-REINFORCED THIN SHEET RESPONSE TO IMPACT LOADS
- Flow of Fiber-Reinforced Cement Slurries at Elevated Temperatures Y. Wang and C. Meyer