Four-dimensional electrical capacitance tomography imaging using experimental data
 

Summary: Four-dimensional electrical capacitance tomography imaging using
experimental data
1
M Soleimani, 1
CN Mitchell, 1,2
R Banasiak, 2
R Wajman, 3
A Adler
1
Electronic and electrical engineering, The University of Bath, Bath, UK, Email: m.soleimani@bath.ac.uk
2
Computer Engineering Department, Technical University of Lodz, Poland
3
Systems and Computer Engineering, Carleton University, Canada
Abstract: Electrical capacitance tomography (ECT) is a relatively mature non-invasive imaging
technique that attempts to map dielectric permittivity of materials. ECT has become a promising
monitoring technique in industrial process tomography especially in fast flow visualization. One of
the most challenging tasks in further development of ECT for real applications are the
computational aspects of the ECT imaging. Recently, 3D ECT has gained interest because of its
potential to generate volumetric images. Computation time of image reconstruction in 3D ECT

  

Source: Adler, Andy - Department of Systems and Computer Engineering, Carleton University

 