A series of computer runs were made using DEPAB2 (the boiler simulation computer program). They include the runs for a fire-tube boiler as is (i.e., without turbulators), with wire-coil type turbulators, and with twisted-tape type turbulators, respectively. Output from these runs are used to evaluate the boiler seasonal performance values under the Washington, D.C. weather conditions. Results show that the turbulator increases the boiler seasonal efficiency from 2.87 to 6.08%.
|
| Authors: |
Didion, D.;
Chern, L.
|
| Publication Date: | 1984 Aug 01 |
| OSTI Identifier: | 5782217 |
| Report Number(s): | PB-85-177871/XAB; NBSIR-84/2925 |
| Resource Type: | Technical Report |
| Resource Relation: | Sponsored by Army Facilities Engineering Support Agency, Fort Belvoir, VA, Technology Support Div |
| Research Org: | National Engineering Lab. (NBS), Washington, DC (USA) |
| Country of Publication: | United States |
| Language: | English |
| Format: | Size: Pages: 25 |
| Subject: | 42 ENGINEERING; BOILERS; PERFORMANCE; COMPUTERIZED SIMULATION; EFFICIENCY; SIMULATION |
| Availability: | NTIS, PC A02/MF A01. |
| Update Date: | 2008 Feb 07 |
Top |
|