| 513 K 16 pp. |   | |
| View Document |   | |
|   | ||
| Title | Determination of the Neutron Magnetic Moment | |
| Author(s) | Greene, G. L.; Ramsey, N. F.; Mampe, W.; Pendlebury, J. M.; Smith, K. ; Dress, W. B.; Miller, P. D.; Perrin, P. | |
| Publication Date | June 1981 | |
| Report Number | CONF-810695-1 | |
| Unique Identifier | ACC0283 | |
| Other Numbers | Legacy ID: DE81024116; OSTI ID: 6190868 | |
| Research Org | Oak Ridge National Laboratory, TN (USA); Harvard University, Cambridge, MA (USA); Institut Max von Laue - Paul Langevin, 38 - Grenoble (France); Sussex University, Brighton (UK). Astronomy Centre | |
| Contract No | W-7405-ENG-26 | |
| Sponsoring Org | U.S. Department of Energy (DOE) | |
| Other Information | 2nd International Conference on Precision Measurements and Fundamental Constants; Jun 1981; Gaithersburg, MD, USA | |
| Subject | 651100 -- Nuclear Physics -- Experimental Techniques -- (1980-); 651214 -- Nuclear Properties & Reactions, A=1-5, Theoretical -- Moments and Spin -- (-1987); Magnetic Moments -- Measuring Methods; Neutrons -- Magnetic Moments; Protons -- Magnetic Moments; Experimental Data; Magnetic Resonance; Ultracold Neutrons | |
| Keywords | Baryons; Cold Neutrons; Data; Elementary Particles; Fermions; Hadrons; Information; Neutrons; Nucleons; Numerical Data; Resonance; Nuclear Physics and Radiation Physics | |
| Related Web Pages | Norman Ramsey and the Separated Oscillatory Fields Method | |
| Abstract | The neutron magnetic moment has been measured with an improvement of a factor of 100 over the previous best measurement. Using a magnetic resonance spectrometer of the separated oscillatory field type capable of determining a resonance signal for both neutrons and protons (in flowing H{sub 2}O), we find ..mu..{sub n}/..mu..{sub p} = 0.68497935(17) (0.25 ppM). The neutron magnetic moment can also be expressed without loss of accuracy in a variety of other units. | |
| 513 K 16 pp. |   | |
| View Document |   | |
|   | ||