skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: CROWTM PROCESS APPLICATION FOR SITES CONTAMINATED WITH LIGHT NON-AQUEOUS PHASE LIQUIDS AND CHLORINATED HYDROCARBONS

Technical Report ·
DOI:https://doi.org/10.2172/821181· OSTI ID:821181

Western Research Institute (WRI) has successfully applied the CROWTM (Contained Recovery of Oily Wastes) process at two former manufactured gas plants (MGPs), and a large wood treatment site. The three CROW process applications have all occurred at sites contaminated with coal tars or fuel oil and pentachlorophenol (PCP) mixtures, which are generally denser than water and are classified as dense non-aqueous phase liquids (DNAPLs). While these types of sites are abundant, there are also many sites contaminated with gasoline, diesel fuel, or fuel oil, which are lighter than water and lie on top of an aquifer. A third site type occurs where chlorinated hydrocarbons have contaminated the aquifer. Unlike the DNAPLs found at MGP and wood treatment sites, chlorinated hydrocarbons are approximately one and a half times more dense than water and have fairly low viscosities. These contaminants tend to accumulate very rapidly at the bottom of an aquifer. Trichloroethylene (TCE) and perchloroethylene, or tetrachloroethylene (PCE), are the major industrial chlorinated solvents that have been found contaminating soils and aquifers. The objective of this program was to demonstrate the effectiveness of applying the CROW process to sites contaminated with light non-aqueous phase liquids (LNAPLs) and chlorinated hydrocarbons. Individual objectives were to determine a range of operating conditions necessary to optimize LNAPL and chlorinated hydrocarbon recovery, to conduct numerical simulations to match the laboratory experiments and determine field-scale recoveries, and determine if chemical addition will increase the process efficiency for LNAPLs. The testing consisted of twelve TCE tests; eight tests with PCE, diesel, and wood treatment waste; and four tests with a fuel oil-diesel blend. Testing was conducted with both vertical and horizontal orientations and with ambient to 211 F (99 C) water or steam. Residual saturations for the horizontal tests ranged from 23.6% PV to 0.3% PV. Also conducted was screening of 13 chemicals to determine their relative effectiveness and the selection of three chemicals for further testing.

Research Organization:
Western Research Institute (US)
Sponsoring Organization:
(US)
DOE Contract Number:
FC26-98FT40322
OSTI ID:
821181
Resource Relation:
Other Information: PBD: 30 Jun 2003
Country of Publication:
United States
Language:
English