skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Elevated tritium levels at the World Trade Center

Conference ·
OSTI ID:799642

Traces of tritiated water (HTO) were detected at [the]World Trade Center (WTC) ground zero after the 9/11/01 terrorist attack. A method of ultralow-background liquid scintillation counting was used after distilling HTO from the samples. A water sample from the WTC sewer, collected on 9/13/01, contained 0.174 plus or minus 0.074 (2s) nCi/L of HTO. A split water sample, collected on 9/21/01 from the basement of WTC Building 6, contained 3.53 plus or minus 0.17 and 2.83 plus or minus 0.15 nCi/L, respectively. Several water and vegetation samples were analyzed from areas outside the ground zero, located in Manhattan, Brooklyn, Queens, and Kensico Reservoir. No HTO above the background was found in those samples. All these results are well below the levels of concern to human exposure.

Research Organization:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Organization:
National Institutes of Health (US)
DOE Contract Number:
AC03-76SF00098
OSTI ID:
799642
Report Number(s):
LBNL-50782; R&D Project: 865037; B& R 400412000; TRN: US0206122
Resource Relation:
Conference: 223rd American Chemical Society National Meeting, Orlando, FL (US), 04/07/2002--04/11/2002; Other Information: PBD: 14 May 2002
Country of Publication:
United States
Language:
English