skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Relationship between air sampling data from glove box work areas and inhalation risk to the worker

Technical Report ·
DOI:https://doi.org/10.2172/4299688· OSTI ID:4299688

A mockup of a plutonium work area was equipped to simulate and monitor aerosol leaks from a glove box into the worker's environment. Dioctyl phthalate was the tracer aerosol used, and aerosol concentration throughout the work area was monitored under several different ventilating conditions. Aerosol concentration in the worker's breathing zone was up to 250 times greater than the concentrations that might be indicated by typical fixed room-air samplers located adjacent to the glove box. The effuct on the magnitude and pattern of aerosol dispersal was evaluated in light of ventilation rate and direction of the ventilating air flow relative to the leak. (auth)

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-4705-ENG-36
NSA Number:
NSA-29-029320
OSTI ID:
4299688
Report Number(s):
LA-5520-MS
Resource Relation:
Other Information: Orig. Receipt Date: 30-JUN-74
Country of Publication:
United States
Language: