skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Sand filter backwash pit criticality analysis

Conference ·
OSTI ID:10141499

In May 1993, a potential criticality problem arose in the KE Basin and filter backwash pit on the Hanford site. The problem necessitated extensive criticality analyses to establish the subcritical margin in that particular facility. This paper will describe the analyses and also point out some of the difficulties in applying American National Standards Institute (ANSI) standards to the situation.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
10141499
Report Number(s):
WHC-SA-2007; CONF-940553-34; ON: DE94009763; BR: 35AF11201/35AF11202
Resource Relation:
Conference: International high-level radioactive waste management conference,Las Vegas, NV (United States),22-26 May 1994; Other Information: PBD: Jan 1994
Country of Publication:
United States
Language:
English