skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Use of Electrochemical Noise to Assess Corrosion in Kraft Continuous Digesters

Technical Report ·
DOI:https://doi.org/10.2172/838102· OSTI ID:838102

Electrochemical noise (EN) probes were deployed in two continuous kraft digesters at a variety of locations representative of corrosion throughout the vessels. Current and potential noise, the temperature at each probe location, and the value of up to 60 process parameters (flow rates, liquor chemistry, etc.) were monitored continuously during each experiment. The results indicate that changes in furnish composition and process upsets were invariably associated with concurrent substantial changes in EN activity throughout the vessels. Post-test evaluation of the mild steel electrode materials in both vessels confirmed general corrosion of a magnitude consistent with historical trends in the respective vessels as well as values qualitatively (and semi-quantitatively) related to EN current sums for each electrode pair. Stainless steel electrodes representing 309LSi and 312 overlay repairs exhibited zero wastage corrosion--as did the actual overlays--but the EN data indicated periodic redox activity on the stainless steel that varied with time and position within the vessel. Little or no correlation between EN probe activity and other operational variables was observed in either vessel. Additional details for each digester experiment are summarized.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
838102
Report Number(s):
ORNL/TM-2004/187; TRN: US200507%%322
Resource Relation:
Other Information: PBD: 29 Nov 2004
Country of Publication:
United States
Language:
English