Stress corrosion cracking of type 304L stainless steel core shroud welds.
Microstructural analyses by advanced metallographic techniques were conducted on mockup welds and a cracked BWR core shroud weld fabricated from Type 304L stainless steel. heat-affected zones of the shroud weld and mockup shielded-metal-arc welds were free of grain-boundary carbide, martensite, delta ferrite, or Cr depletion near grain boundaries. However, as a result of exposure to welding fumes, the heat-affected zones of the welds were significantly contaminated by fluorine and oxygen which migrate to grain boundaries. Significant oxygen contamination promotes fluorine contamination and suppresses classical thermal sensitization, even in Type 304 steels. Results of slow-strain-rate tensile tests indicate that fluorine exacerbates the susceptibility of irradiated steels to intergranular stress corrosion cracking. These observations, combined with previous reports on the strong influence of weld flux, indicate that oxygen and fluorine contamination and fluorine-catalyzed stress corrosion play a major role in cracking of Type 304L stainless steel core shroud welds.
- Research Organization:
- Argonne National Lab., IL (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- W-31-109-ENG-38
- OSTI ID:
- 750442
- Report Number(s):
- ANL/ET/CP-98089; TRN: US200221%%488
- Resource Relation:
- Conference: 9th International Conference on Environmental Degradation of Materials in Nuclear Power Systems-Water Reactors, Newport Beach, CA (US), 08/01/1999--08/05/1999; Other Information: PBD: 26 Oct 1999
- Country of Publication:
- United States
- Language:
- English
Similar Records
Stress corrosion cracking of austenitic stainless steel core internal welds.
Fabrication-related impurity contamination and stress corrosion cracking of austenitic stainless steel core-internal components