skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: /sup 99m/Tc-DTPA scintillation-camera renography: a new method for estimation of single-kidney function

Journal Article · · J. Nucl. Med.; (United States)
OSTI ID:7226293

A new method of combined serial scintigraphy and renography, using a scintillation camera and /sup 99m/Tc-DTPA is evaluated. Renographic curves, corresponding to light-pen ''areas of interest'' over the renal parenchyma, were processed. ''Blood-background'' curves were recorded from an external detector over the temporal region of the head and also from an ''area of interest'' corresponding to the aorta and inferior vena cava. The uptake phase of the renogram was always linear. The sum of the slopes of the uptake phase of both kidneys correlated well with the measured glomerular filtration rate in 25 patients with renal insufficiency of various degrees. Single-kidney function estimated from the slopes correlated reasonably well with single-kidney function estimated from /sup 131/I-Hippuran renography with external detectors. The method described minimizes errors in the estimation of single-kidney function, and both anatomic and functional information is obtained.

Research Organization:
Frederiksberg Hospital, Copenhagen
OSTI ID:
7226293
Journal Information:
J. Nucl. Med.; (United States), Vol. 18:2
Country of Publication:
United States
Language:
English