Structural analysis of the Heel Jet secondary catch mechanism
Technical Report
·
OSTI ID:71576
Studies of the Heel Jet Pump lifting bail weld indicate that the weld process and/or weld material used may be incompatible with the base metal. For this reason, a backup design for hoist of the Heel Jet Pump is necessary. By using a 0.0508 m (2 in.) and 0.0762 m (3 in.) jumper connector in conjunction with the existing lifting bail the Heel Jet Pump can be safely hoisted.