Determination of net heat fluxes and assessment of test-to-test thermal input variation for three large engulfing open pool fire/calorimeter tests
Technical Report
·
OSTI ID:7150304
Three 30-minute large engulfing open pool fire tests were conducted to determine the local thermal input from the fire environment to a test article. The local thermal input was evaluated numerically based on experimental temperature measurements and expressed in terms of instantaneous and time-integrated local heat fluxes. Additionally, the variation in test-to-test temperatures was assessed and compared with a regulatory (10CFR71) fire. The test articles employed were large cylindrical calorimeters with physical dimensions of 137 cm (54 in) I.D., 6.4 m (21 ft) axial length and 3.18 cm (1.25 in) wall thickness. The pool was rectangular with dimensions 9.14 x 18.29 m (30 x 60 ft).
- Research Organization:
- Sandia National Labs., Albuquerque, NM (USA)
- DOE Contract Number:
- AC04-76DP00789
- OSTI ID:
- 7150304
- Report Number(s):
- SAND-85-1821; TTC-0575; ON: DE87002884
- Resource Relation:
- Other Information: Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted
- Country of Publication:
- United States
- Language:
- English
Similar Records
Design of an actively cooled plate calorimeter for the investigation of pool fire heat fluxes
Experimental measurement of heat flux to large and small calorimeters in an engulfing pool fire
Experimental measurement of heat flux to large and small calorimeters in an engulfing pool fire
Conference
·
Wed Jan 01 00:00:00 EST 1992
·
OSTI ID:7150304
+1 more
Experimental measurement of heat flux to large and small calorimeters in an engulfing pool fire
Conference
·
Fri Jul 01 00:00:00 EDT 1983
· HTD (Publ.) (Am. Soc. Mech. Eng.); (United States)
·
OSTI ID:7150304
Experimental measurement of heat flux to large and small calorimeters in an engulfing pool fire
Conference
·
Sat Jan 01 00:00:00 EST 1983
·
OSTI ID:7150304