Title: Sensitivity of BWR shutdown margin tests to local reactivity anomalies

Conference · · Trans. Am. Nucl. Soc.; (United States)
OSTI ID:7100995

Successful shutdown margin (SDM) demonstration is a required procedure in the startup of a newly configured boiling water reactor (BWR) core. In its most reactive condition throughout a cycle, a BWR core must be capable of being made subcritical by a specified margin with the highest worth control rod fully withdrawn and all other rods at their fully inserted positions. Two different methods are used to demonstrate SDM: (a) the adjacent-rod test and (b) the in-sequence test. In the adjacent-rod test, the strongest rod is fully withdrawn and an adjacent rod is withdrawn to reach criticality. In the in-sequence test, control rods spread throughout the core are withdrawn in a predetermined sequence of withdrawals. Larger than expected core k/sub eff/ values have been observed during the performance of BWR SDM tests. The purpose of the work summarized in this paper has been to investigated and quantify the sensitivity of both the adjacent-rod and in-sequence SDM tests to local reactivity anomalies. This was accomplished by introducing reactivity perturbations at selected four-bundle cell locations and by evaluating their effect on core reactivity in each of the two tests.

Research Organization:
Brookhaven National Lab., Upton, NY (USA)
OSTI ID:
7100995
Report Number(s):
CONF-8711195-; TRN: 88-033345
Journal Information:
Trans. Am. Nucl. Soc.; (United States), Vol. 55; Conference: American Nuclear Society winter meeting, Los Angeles, CA, USA, 15 Nov 1987
Country of Publication:
United States
Language:
English