skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Experimental facility for containment sump reliability studies (Generic Task A-43). [PWR; BWR]

Technical Report ·
DOI:https://doi.org/10.2172/7042938· OSTI ID:7042938

On July 3, 1979, Sandia National Laboratories (Sandia) contracted the Alden Research Laboratory (ARL) to conduct tests on unresolved safety issues associated with containment sump performance during the recirculation mode (Generic Task A-43). This report describes the test facility constructed and completed under Phase I, Task III of the contract. Sump performance is determined through the observation of vortex formation in the main tank and the measurement of swirl, pressure gradient, and entrained air in the suction pipes. The use of electrically operated valves and a sophisticated data acquisition system, with computer interface, allows the test flow parameters to be set and test data to be taken (with the exception of vortex observations) from a single central office.

Research Organization:
Worcester Polytechnic Inst., Holden, MA (USA). Alden Research Lab.
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
7042938
Report Number(s):
ALO-132; TRN: 81-000938
Country of Publication:
United States
Language:
English