This report covers Los Alamos test cell operation during the winter of 1981-82 including comparisons with the 1980-81 winter. Extensive data have been taken and computer-analyzed to determine performance parameters such as efficiency, solar savings fraction, and discomfort index. The data from different test cells are directly comparable because each has similar heating-load coefficient and collector area. Configurations include direct gain, unvented Trombe walls, water wall, phase-change wall, and sunspaces. Strategies for reducing heat loss include selective surfaces, two types of improved glazing systems, a heat pipe system, and convection suppression baffles. Significant differences in both auxiliary heat and comfort were observed among the various system types. The results are useful, not only for direct system comparisons, but also to provide data for validation of computer simulation programs. Availability of hourly data is described.

Research Organization:
Los Alamos National Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6980523
Report Number(s):
LA-9543-MS; ON: DE83002948
Resource Relation:
Other Information: Includes 2 sheets of 48x reduction microfiche