Ac loss measurement of SSC dipole magnets
AC losses in full length and 1.5 m model SSC collider dipoles were successfully measured by the direct observation of energy flow into and out of magnets during a ramp cycle. The measurement was performed by using two double-integrating type digital volt meters (DVM's) for current and voltage measurement. Measurements were performed for six is m long ASST magnets and five 1.5 m long model magnets, inducting one 40 mm diameter magnet. There were large variations in the eddy current losses. Since these magnets use conductors with slight deviations in their internal structures and processing of the copper surface depending on the manufacturer, it is likely that there are differences in the contact resistance between strands. Correlation between the ramp rate dependence of the,quench current and the eddy current loss was evident.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE; USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 6973914
- Report Number(s):
- FNAL/C-92/238; CONF-9206281-3; ON: DE93001950; TRN: 92-038082
- Resource Relation:
- Conference: ICFA workshop on AC superconductivity, Tsukuba (Japan), 23-25 Jun 1992
- Country of Publication:
- United States
- Language:
- English
Similar Records
AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab
AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab
Related Subjects
SUPERCONDUCTING MAGNETS
POWER LOSSES
SUPERCONDUCTING SUPER COLLIDER
EDDY CURRENTS
EVALUATION
MAGNETIC FIELDS
MEASURING METHODS
QUENCHING
VOLTMETERS
CURRENTS
ELECTRIC CURRENTS
ELECTRIC MEASURING INSTRUMENTS
ELECTRICAL EQUIPMENT
ELECTROMAGNETS
ENERGY LOSSES
EQUIPMENT
LOSSES
MAGNETS
MEASURING INSTRUMENTS
STORAGE RINGS
SUPERCONDUCTING DEVICES
430303* - Particle Accelerators- Experimental Facilities & Equipment