skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Thermal striping downstream of a horizontal elbow under thermally stratified transient flow conditions

Conference ·
OSTI ID:6776997

A thermally stratified flow produced by a thermal transient passing through a horizontal elbow gives rise to large thermal fluctuations on the inner curvature wall of the downstream piping. These fluctuations were measured in a specially instrumented horizontal pipe and elbow system on a test set-up using water in the Mixing Components Technology Facility. This study is part of a larger program which is studying the influence of thermal buoyancy on general reactor component performance. This paper discusses the influence of pipe flow generated thermal oscillations on the structured thermal stresses induced in the pipe walls.

Research Organization:
Argonne National Lab., IL (USA)
DOE Contract Number:
W-31-109-ENG-38
OSTI ID:
6776997
Report Number(s):
CONF-841105-10; ON: DE84014687
Resource Relation:
Conference: Joint meeting of the American Nuclear Society and the Atomic Industrial Forum, Washington, DC, USA, 11 Nov 1984; Other Information: Portions are illegible in microfiche products
Country of Publication:
United States
Language: