Step-by-step instructions are given for converting existing south-facing masonry walls into Trombe walls. Locally-available materials are used for the most part and minimal carpentry skills are required. Some design variations and modifications are suggested. Performance monitoring and operation and maintenance are discussed. Costs are estimated to total $374. A way is given to estimate energy savings. (LEW)
- Research Organization:
- Stevens Point Area Co-op, WI (USA)
- DOE Contract Number:
- FG02-80R510252; FG02-81R510333
- OSTI ID:
- 6611235
- Report Number(s):
- DOE/R5/10333-3; ON: DE83005189
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cooperative passive-solar commercial retrofit. Final report, September 1, 1980-December 31, 1982
Building a retrofit Trombe wall
Controlled integration of Trombe wall and direct gain in passive solar residences
Technical Report
·
Wed Dec 01 00:00:00 EST 1982
·
OSTI ID:6611235
Building a retrofit Trombe wall
Journal Article
·
Thu May 01 00:00:00 EDT 1980
· Sunpaper; (United States)
·
OSTI ID:6611235
Controlled integration of Trombe wall and direct gain in passive solar residences
Conference
·
Thu Jan 01 00:00:00 EST 1981
· Proc. Annu. Meet. - Am. Sect. Int. Sol. Energy Soc.; (United States)
·
OSTI ID:6611235
Related Subjects
14 SOLAR ENERGY
TROMBE WALLS
RETROFITTING
CONSTRUCTION
COST
ENERGY EXPENSES
MAINTENANCE
MATERIALS
OPERATION
PERFORMANCE TESTING
ENERGY SYSTEMS
EQUIPMENT
HEATING SYSTEMS
PASSIVE SOLAR HEATING SYSTEMS
SOLAR EQUIPMENT
SOLAR HEATING SYSTEMS
TESTING
WALLS
140901* - Solar Thermal Utilization- Space Heating & Cooling
TROMBE WALLS
RETROFITTING
CONSTRUCTION
COST
ENERGY EXPENSES
MAINTENANCE
MATERIALS
OPERATION
PERFORMANCE TESTING
ENERGY SYSTEMS
EQUIPMENT
HEATING SYSTEMS
PASSIVE SOLAR HEATING SYSTEMS
SOLAR EQUIPMENT
SOLAR HEATING SYSTEMS
TESTING
WALLS
140901* - Solar Thermal Utilization- Space Heating & Cooling