Transmission-line impedance measurements of beam pipes for an Advanced Hadron Facility (AHF)
Conference
·
OSTI ID:6599521
An Advanced Hadron Facility (AHF) requires a beam pipe with low eddy-current losses and a low beam-coupling impedance. The requirements cannot be met with a solid, conducting beam pipe but may be met by a ceramic pipe with conducting layers, which may have a higher coupling impedance. We have measured and compared the transmission-line impedances for several candidate pipe segments. The results are correlated with the beam-coupling impedance and are compared with calculated values and with AHF requirements.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 6599521
- Report Number(s):
- LA-UR-87-888; CONF-870302-21; ON: DE87007487
- Resource Relation:
- Conference: Particle accelerator conference, Washington, DC, USA, 16 Mar 1987; Other Information: Paper copy only, copy does not permit microfiche production
- Country of Publication:
- United States
- Language:
- English