Environmental assessment of a wood-waste-fired industrial firetube boiler. Volume 1. Technical results. Final report, January 1981-March 1984
The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue gas emissions: source assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue gas organics in two boiling point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO/sub 2/ and SO/sub 3/; and grab sampling of boiler bottom ash for trace element content determinations. Total organic emissions from the boiler were 5.7 mg/dscm, about 90% of which consisted of volatile compounds.
- Research Organization:
- Acurex Corp., Mountain View, CA (USA). Environmental Systems Div.
- OSTI ID:
- 6550265
- Report Number(s):
- PB-87-176285/XAB; TR-83-123/ESD-VOL-1
- Resource Relation:
- Other Information: See also Volume 2, PB--87-176293
- Country of Publication:
- United States
- Language:
- English
Similar Records
Environmental assessment of a firetube boiler firing coal/oil/water mixtures. Volume 1. Technical results. Final report, February 1981-November 1983
Environmental assessment of a wood-waste-fired industrial watertube boiler. Volume 2. Data supplement. Final report, March 1981-March 1984
Related Subjects
42 ENGINEERING
REFUSE-FUELED BOILERS
AIR POLLUTION ABATEMENT
WOOD WASTES
NITROGEN OXIDES
ORGANIC COMPOUNDS
SULFUR OXIDES
BOILERS
CHALCOGENIDES
NITROGEN COMPOUNDS
OXIDES
OXYGEN COMPOUNDS
POLLUTION ABATEMENT
SOLID WASTES
SULFUR COMPOUNDS
WASTES
320301* - Energy Conservation
Consumption
& Utilization- Industrial & Agricultural Processes- Energy Sources
421000 - Engineering- Combustion Systems