skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Application of a three phase nonsinusoidal calibration system for testing energy and demand meters under simulated field conditions

Journal Article · · IEEE Trans. Power Del.; (United States)
DOI:https://doi.org/10.1109/61.193863· OSTI ID:6495041
;  [1]
  1. National Research Council, Ottawa, Ontario (CA)

The influence of harmonics on commonly used three phase watthour and kVA demand meters was studied using a computer controlled three phase test system capable of generating nonsinusoidal voltages and currents. A description of the new three phase test system and results of preliminary tests of several revenue meters are presented. The performance of the tested meters is compared with the response of time-division and thermal reference meters for different harmonic conditions, primarily field recorded data. Errors up to 2% were observed during the testing of energy meters and up to 35% for kVA demand meters.

OSTI ID:
6495041
Journal Information:
IEEE Trans. Power Del.; (United States), Vol. 3:3
Country of Publication:
United States
Language:
English