skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Monte Carlo prompt dose calculations for the National Ingition Facility

Conference ·
OSTI ID:639694

During peak operation, the National Ignition Facility (NIF) will conduct as many as 600 experiments per year and attain deuterium- tritium fusion yields as high as 1200 MJ/yr. The radiation effective dose equivalent (EDE) to workers is limited to an average of 03 mSv/yr (30 mrem/yr) in occupied areas of the facility. Laboratory personnel determined located outside the facility will receive EDEs <= 0.5 mSv/yr (<= 50 mrem/yr). The total annual occupational EDE for the facility will be maintained at <= 0.1 person-Sv/yr (<= 10 person- rem/yr). To ensure that prompt EDEs meet these limits, three- dimensional Monte Carlo calculations have been completed.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
639694
Report Number(s):
UCRL-JC-127604; CONF-971065-; ON: DE98051548; CNN: W-7405-Eng-48
Resource Relation:
Conference: 17. IEEE/NPSS symposium on fusion engineering, San Diego, CA (United States), 6-10 Oct 1997; Other Information: PBD: 1 Jan 1997
Country of Publication:
United States
Language:
English