Title: A method for correcting NaI spectra for attenuation losses in hand-held instrument applications

Journal Article · · IEEE Transactions on Nuclear Science
DOI:https://doi.org/10.1109/23.682700· OSTI ID:624241
; ;  [1]
  1. Los Alamos National Lab., NM (United States)

In this paper the authors present the gross-count material basis set (GC-MBS) method for estimating transmission losses in measurements of radionuclides using low-resolution gamma-ray detectors such as NaI or CdZnTe. The application to continuum-subtracted peaks measured with high-purity germanium detectors is also discussed. To illustrate the method, they apply it to the correction of spectra from enriched uranium that have been distorted by various intervening absorbers. They also examine the application to simultaneous determination of the uranium enrichment through an unknown absorber using a NaI detector.

Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
624241
Report Number(s):
CONF-971147-; ISSN 0018-9499; TRN: 98:006495
Journal Information:
IEEE Transactions on Nuclear Science, Vol. 45, Issue 3Pt1; Conference: Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference, Albuquerque, NM (United States), 11-13 Nov 1997; Other Information: PBD: Jun 1998
Country of Publication:
United States
Language:
English