Title: Field investigation and facility review of eight modular starved-air heat-recovery incinerator systems. Final report, March-November 1982

Technical Report ·
OSTI ID:5969237

The goal of this project was to verify and augment the technical and cost data on modular incinerators that were obtained in a previous study. Eight modular starved-air heat-recovery incinerator (HRI) facilities ranging from 20 to 110 tons per day were visited. The equipment, facility layout, and operations were observed and photographed. Supervisors, operators, and maintenance personnel were interviewed at length about their experience with the HRI equipment and supporting facilities. To aid in the future development of design guidelines for HRI facilities, an emphasis was placed on documenting operational problems and the modifications involved in solving these problems. Where available, cost information for labor, modifications, spare parts, and consumables (utilities, chemicals, ash disposal, pest control) were obtained.

Research Organization:
SCS Engineers, Inc., Long Beach, CA (USA)
OSTI ID:
5969237
Report Number(s):
AD-A-147680/3/XAB
Country of Publication:
United States
Language:
English