Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air
General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C12-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cu m ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cu m and sub-pg/cu m levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured. Background levels of these compounds in the ambient air were also determined. Total PCDDs, PCDFs, TBDFs, and PeBDFs were detected in a low concentration range of 0.3 to 3.0 pg/cu m.
- Research Organization:
- Environmental Protection Agency, Research Triangle Park, NC (United States). Atmospheric Research and Exposure Assessment Lab.
- OSTI ID:
- 5830647
- Report Number(s):
- PB-92-129600/XAB
- Resource Relation:
- Other Information: See also PB91-196063. Prepared in cooperation with National Aeronautics and Space Administration, Bay Saint Louis, MS. John C. Stennis Space Center
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation of methodology for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air
Results of monitoring for PCDDs and PCDFs in ambient air at McMurdo Station, Antarctica
Related Subjects
BENZOFURANS
AIR POLLUTION MONITORING
DIOXIN
AIR SAMPLERS
ECOLOGICAL CONCENTRATION
GAS ANALYSIS
GAS CHROMATOGRAPHY
MASS SPECTROSCOPY
METAL INDUSTRY
CHROMATOGRAPHY
EQUIPMENT
FURANS
HETEROCYCLIC COMPOUNDS
INDUSTRY
MONITORING
ORGANIC COMPOUNDS
ORGANIC OXYGEN COMPOUNDS
SAMPLERS
SEPARATION PROCESSES
SPECTROSCOPY
540120* - Environment
Atmospheric- Chemicals Monitoring & Transport- (1990-)