skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Criticality benchmark calculations of the ESADA plutonium program experiments with MCNP

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:552586
;  [1]
  1. Univ. of Texas, Austin, TX (United States)

An element of benchmark calculations is the assessment of reliability and suitability of codes and cross-section libraries. In this paper, we present benchmark calculations of the single-region experiments that were part of the ESADA Plutonium Program using MCNP-4A with ENDF/B-VI cross-section libraries. These critical experiments were performed at the Westinghouse Reactor Evaluation Center in 1967 for several mixed-oxide (MOX) and UO{sub 2}-fueled core configurations.

OSTI ID:
552586
Report Number(s):
CONF-971125-; ISSN 0003-018X; TRN: 98:001786
Journal Information:
Transactions of the American Nuclear Society, Vol. 77; Conference: 1997 American Nuclear Society (ANS) winter meeting, Albuquerque, NM (United States), 16-20 Nov 1997; Other Information: PBD: 1997
Country of Publication:
United States
Language:
English