Scale model test results for an inverted U-tube steam generator with comparisons to heat transfer correlations
To provide data for assessment and development of thermal-hydraulic computer codes, bottom main feedwater-line-break transient simulations were performed in a scale model (Semiscale Mod-2C) of a pressurized water reactor (PWR) with conditions typical of a PWR (15.0 MPa primary pressure, 600 K steam generator inlet plenum fluid temperatures, 6.2 MPa secondary pressure). The state-of-the-art measurements in the scale model (Type III) steam generator allow for the determination of U-tube steam generator allow for the determination of U-tube steam generator secondary component interactions, tube bundle local radial heat transfer, and tube bundle and riser vapor void fractions for steady state and transient operations. To enhance the understanding of the observed phenomena, the component interactions, local heat fluxes, local secondary convective heat transfer coefficients and local vapor void fractions are discussed for steady state, full-power and transient operations. Comparisons between the measurement-derived secondary convective heat transfer coefficients and those predicted by a number of correlations, including the Chen correlation currently used in thermal-hydraulic computer codes, show that none of the correlations adequately predict the data and points out the need for the formulation of a new correlation based on this experimental data. The unique information presented herein should be of the interest to anyone involved in modeling inverted U-tube steam generator thermal-hydraulics for forced convection boiling/vaporization heat transfer. 5 refs., 13 figs., 1 tab.
- Research Organization:
- EG and G Idaho, Inc., Idaho Falls, ID (USA)
- Sponsoring Organization:
- DOE/NE
- DOE Contract Number:
- AC07-76ID01570
- OSTI ID:
- 5497112
- Report Number(s):
- EGG-M-36787; CONF-871234-16; ON: DE90002003; TRN: 89-030963
- Resource Relation:
- Conference: ASME winter meeting, Boston, MA (USA), 13-18 Dec 1987
- Country of Publication:
- United States
- Language:
- English
Similar Records
Steady-state heat transfer in an inverted U-tube steam generator
Steady-state heat transfer in an inverted U-tube steam generator
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
99 GENERAL AND MISCELLANEOUS//MATHEMATICS, COMPUTING, AND INFORMATION SCIENCE
PWR TYPE REACTORS
LOSS OF COOLANT
COMPARATIVE EVALUATIONS
COMPUTER CODES
FEEDWATER
FLUID FLOW
HEAT TRANSFER
HYDRAULICS
MATHEMATICAL MODELS
PIPES
REACTOR COOLING SYSTEMS
REACTOR SAFETY
SCALE MODELS
STEADY-STATE CONDITIONS
STEAM GENERATORS
TESTING
TRANSIENTS
ACCIDENTS
BOILERS
COOLING SYSTEMS
ENERGY SYSTEMS
ENERGY TRANSFER
FLUID MECHANICS
HYDROGEN COMPOUNDS
MECHANICS
OXYGEN COMPOUNDS
REACTOR ACCIDENTS
REACTOR COMPONENTS
REACTORS
SAFETY
STRUCTURAL MODELS
VAPOR GENERATORS
WATER
WATER COOLED REACTORS
WATER MODERATED REACTORS
220900* - Nuclear Reactor Technology- Reactor Safety
210200 - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
990230 - Mathematics & Mathematical Models- (1987-1989)
990220 - Computers
Computerized Models
& Computer Programs- (1987-1989)