skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A survey of an air monitoring program

Technical Report ·
DOI:https://doi.org/10.2172/527487· OSTI ID:527487

The objective of this report is to compare personal air sampling data to stationary air sampling data and to bioassay data that was taken during the decontamination and decommissioning of sixty-one plutonium glove boxes at Argonne National Laboratory (ANL) in 1995. An air monitoring program administered at Argonne National Laboratory was assessed by comparing personal air sampler (PAS) data, stationary air sampler (SAS) data, and bioassay data. The study revealed that the PAS and SAS techniques were equivalent when averaged over all employees and all workdays, but the standard deviation was large. Also, large deviations were observed in individual samples. The correlation between individual PAS results and bioassay results was low. Personal air samplers and bioassay monitoring played complementary roles in assessing the workplace and estimating intakes. The PAS technique is adequate for detection and evaluation of contaminated atmospheres, whereas bioassay monitoring is better for determining individual intakes.

Research Organization:
Colorado State Univ., Fort Collins, CO (United States)
Sponsoring Organization:
USDOE Office of Energy Research, Washington, DC (United States)
DOE Contract Number:
AC05-76OR00033
OSTI ID:
527487
Report Number(s):
DOE/OR/00033-T705; ON: DE97053345; TRN: 97:016568
Resource Relation:
Other Information: TH: Thesis (M.S.); PBD: Spr 1997
Country of Publication:
United States
Language:
English