Signal analysis method using cross-correlation of turbulence flow signals to determine calibration of permanent magnet sodium flowmeters
Conference
·
OSTI ID:5195884
Permanent magnet flowmeters are used to measure flow in sodium cooled power plants both in the core and in plant piping. In this paper the cross-correlation technique and in particular the transfer function method is used to process the flow turbulence signals from electrodes spaced along the pipe in the vicinity of the magnetic field. Results from a loop flowmeter the EBR-II secondary flowmeter and a 400 mm diameter flowmeter are presented.
- Research Organization:
- Argonne National Lab., IL (USA)
- DOE Contract Number:
- W-31-109-ENG-38
- OSTI ID:
- 5195884
- Report Number(s):
- CONF-771023-23; TRN: 78-005221
- Resource Relation:
- Conference: Nuclear science symposium, San Francisco, CA, USA, 19 Oct 1977
- Country of Publication:
- United States
- Language:
- English
Similar Records
24-inch permanent magnet flowmeter performance in liquid sodium
Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters
Feasibility of calibration of liquid sodium flowmeters by neutron activation techniques
Technical Report
·
Mon Apr 30 00:00:00 EDT 1984
·
OSTI ID:5195884
Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters
Technical Report
·
Thu Mar 31 00:00:00 EDT 2022
·
OSTI ID:5195884
+2 more
Feasibility of calibration of liquid sodium flowmeters by neutron activation techniques
Technical Report
·
Thu Jul 01 00:00:00 EDT 1976
·
OSTI ID:5195884
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
47 OTHER INSTRUMENTATION
FLOWMETERS
CALIBRATION
LMFBR TYPE REACTORS
REACTOR COOLING SYSTEMS
EBR-2 REACTOR
BREEDER REACTORS
COOLING SYSTEMS
EPITHERMAL REACTORS
EXPERIMENTAL REACTORS
FAST REACTORS
FBR TYPE REACTORS
LIQUID METAL COOLED REACTORS
MEASURING INSTRUMENTS
POWER REACTORS
REACTOR COMPONENTS
REACTORS
RESEARCH AND TEST REACTORS
SODIUM COOLED REACTORS
210500* - Power Reactors
Breeding
440300 - Miscellaneous Instruments- (-1989)
47 OTHER INSTRUMENTATION
FLOWMETERS
CALIBRATION
LMFBR TYPE REACTORS
REACTOR COOLING SYSTEMS
EBR-2 REACTOR
BREEDER REACTORS
COOLING SYSTEMS
EPITHERMAL REACTORS
EXPERIMENTAL REACTORS
FAST REACTORS
FBR TYPE REACTORS
LIQUID METAL COOLED REACTORS
MEASURING INSTRUMENTS
POWER REACTORS
REACTOR COMPONENTS
REACTORS
RESEARCH AND TEST REACTORS
SODIUM COOLED REACTORS
210500* - Power Reactors
Breeding
440300 - Miscellaneous Instruments- (-1989)