skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Extended laboratory testing of type 316 compression fittings for sour service

Conference ·
OSTI ID:504749
 [1];  [2]
  1. Cortest Labs. Ltd., Sheffield (United Kingdom)
  2. Chevron UK Ltd., Aberdeen (United Kingdom)

Compression fittings are widely used in pressure and vacuum systems in a number of industries including chemical processing, nuclear power and oil and gas production. Previous tests showed type 316 stainless compression fittings can crack when exposed to NACE TM0177 solution at elevated temperatures for 30 days. Following up this finding, one-month, three-month and twelve month tests have been conducted on type 316 compression fittings and instrumentation tubing in order to assess their suitability for sour service. Loops were constructed, containing a total of over three hundred fittings from four manufacturers and filled with sour fluids comprising high chloride content solutions. They were pressurized to 50 bara (5MPa) with CO{sub 2} and H{sub 2}S partial pressures in the range 0--0.8 bara (8 kPa) and maintained at temperatures in the range 60--120 C. The tests showed that, even in mildly sour conditions, at elevated service temperatures cracking can occur and that the threshold H{sub 2}S partial pressure decreases with increasing temperature.

OSTI ID:
504749
Report Number(s):
CONF-970332-; TRN: IM9733%%164
Resource Relation:
Conference: Corrosion 97. 52. annual corrosion conference of the National Association of Corrosion Engineers: economics and performance - bridging the gap and NACExpo, New Orleans, LA (United States), 9-14 Mar 1997; Other Information: PBD: 1997; Related Information: Is Part Of Corrosion/97 conference papers; PB: [4584] p.
Country of Publication:
United States
Language:
English

Similar Records

Evaluation of SSC resistance on super 13Cr stainless steel in sour applications
Book · Sun Oct 01 00:00:00 EDT 1995 · OSTI ID:504749

Surface Studies of Ultra Strength Drilling Steel after Corrosion Fatigue in Simulated Sour Environment
Conference · Sun May 06 00:00:00 EDT 2012 · Extended Abstract Proceeding of the 221 Electrochemical Society Meeting, Seattle, WA, May 6-10, 2012 · OSTI ID:504749

Specified pipe fittings susceptible to sulfide stress cracking
Journal Article · Mon Jan 01 00:00:00 EST 1996 · Materials Performance · OSTI ID:504749