Title: FULL SCALE CLOSURE TEST

Technical Report ·
DOI:https://doi.org/10.2172/4765779· OSTI ID:4765779

The tests performed on a full-scale prototype of the closure designed for the Pathfinder reactor vessel are described. This head was bolted to another head designed to simulate the reactor vessel. The design pressure of the facility is 700 psig at 500 deg F. Strain gages and brittle coatings were used to determine the stresses in the closure. Dial indicator gages were used to measure flange rotation after the head was secured and while it was subjected to hydrostatic pressure. Tests were performed at reactor operating temperature and pressure to evaluate the closure and gasketing. The vessel was thermal cycled, and temperature gradients in the head measured to establish allowable heating and cooling rates. Hydraulically operated bolt tensioners were used to seal and open the closure. Special tools and procedures were developed for underwater operation. (auth)

Research Organization:
Allis-Chalmers Mfg. Co. Atomic Energy Div., Milwaukee
DOE Contract Number:
AT(11-1)-589
NSA Number:
NSA-17-002573
OSTI ID:
4765779
Report Number(s):
ACNP-62002
Resource Relation:
Other Information: For Northern States Power Co., Minneapolis and Central Utilities Atomic Power Associates. Sept. 20, 1962. Orig. Receipt Date: 31-DEC-63
Country of Publication:
United States
Language:
English

Similar Records

PATHFINDER ATOMIC POWER PLANT REACTOR VESSEL STRUCTURAL DESIGN. Final Report
Technical Report · Thu Dec 28 00:00:00 EST 1961 · OSTI ID:4765779

CC Pressure Test
Technical Report · Thu Jul 12 00:00:00 EDT 1990 · OSTI ID:4765779

SEMI-REMOTE CONNECTOR FOR FISSION PRODUCT CASKS
Technical Report · Tue Jul 11 00:00:00 EDT 1961 · OSTI ID:4765779