Title: Metering Research Facility Program. Orifice meter installation effects: Ten-inch sliding flow conditioner tests. Technical memorandum, January-June 1996

Technical Report ·
OSTI ID:445825

This report presents the results of 10-inch (250 mm) orifice meter installation effects test performed in the Gas Research Institute (GRI) Metering Research Facility (MRF) High Pressure Loop (HPL) using a meter tube with an orifice fitting and a short upstream length of 17 pipe diameters (D) installed downstream of a tee. The main objective was to determine the effects of the type and location of flow conditioner in the upstream section of a short, 17 D meter tube on the value of orifice discharge coefficient (Cd). A secondary objective was to confirm the validity of scaling installation effects results from 4-inch to 10-inch diameter by comparing these new results to the 10-inch MRF HPL with previous results obtained in the 4-inch MRF Interim Low Pressure Loop (ILPL).

Research Organization:
Southwest Research Institute, San Antonio, TX (United States)
OSTI ID:
445825
Report Number(s):
PB-97-129308/XAB; CNN: Contract GRI-5095-291-3363; TRN: 70491244
Resource Relation:
Other Information: PBD: Nov 1996
Country of Publication:
United States
Language:
English