Ultrasonic flowmeters undergo accuracy, repeatability tests
- Southwest Research Inst., San Antonio, TX (United States)
Two commercially available multipath ultrasonic flowmeters have undergone tests at Gas Research Institute`s metering research facility (MRF) at Southwest Research institute in San Antonio. The tests were conducted in baseline and disturbed-flow installations to assess baseline accuracy and repeatability over a range of flowrates and pressures. Results show the test meters are capable of accuracies within a 1% tolerance and with repeatability of better than 0.25% when the flowrate is greater than about 5% of capacity. The data also indicates that pressure may have an effect on meter error. Results further suggest that both the magnitude and character of errors introduced by flow disturbances are a function of meter design. Shifts of up to 0.6% were measured for meters installed 10D from a tee (1D = 1 pipe diameter). Better characterization of the effects of flow disturbances on measurement accuracy is needed to define more accurately the upstream piping requirements necessary to achieve meter performance within a specified tolerance. The paper discusses reduced station costs, test methods, baseline tests, effect of pressure, speed of sound, and disturbance tests.
- OSTI ID:
- 413422
- Journal Information:
- Oil and Gas Journal, Vol. 94, Issue 52; Other Information: PBD: 23 Dec 1996
- Country of Publication:
- United States
- Language:
- English