DESIGN AND CONSTRUCTION OF A FARADAY-TYPE ELECTROMAGNETIC PUMP
Technical Report
·
OSTI ID:4116673
Mathematical analysis and optimization led to a design of a Faraday type electromagnetic pump with expected efficiencies of 20 to 50%, depending on the size of the pump. The pump was designed to pump liquid U--Bi at 10 gpm against a head of 100 psi and to operate at lOOO deg F in a radiation environment. (C.J.G.)
- Research Organization:
- Babcock and Wilcox Co. Research Center, Alliance, Ohio
- DOE Contract Number:
- AT(30-1)-1940
- NSA Number:
- NSA-15-002718
- OSTI ID:
- 4116673
- Report Number(s):
- BAW-1251
- Resource Relation:
- Other Information: Changed from OFFICIAL USE ONLY Oct. 18, 1960. Orig. Receipt Date: 31-DEC-61
- Country of Publication:
- United States
- Language:
- English
Similar Records
DESIGN AND OPERATION OF A 10.000 GPM D.C. ELECTROMAGNETIC SODIUM PUMP AND 250.000 AMPERE HOMOPOLAR GENERATOR
DC ELECTROMAGNETIC PUMP STUDY FOR THERMIONIC CONVERSION REACTORS
DESIGN OF TWO ELECTROMAGNETIC PUMPS FOR NaK
Technical Report
·
Fri Oct 31 00:00:00 EST 1958
·
OSTI ID:4116673
DC ELECTROMAGNETIC PUMP STUDY FOR THERMIONIC CONVERSION REACTORS
Technical Report
·
Fri Jul 15 00:00:00 EDT 1960
·
OSTI ID:4116673
DESIGN OF TWO ELECTROMAGNETIC PUMPS FOR NaK
Technical Report
·
Fri Mar 25 00:00:00 EST 1960
·
OSTI ID:4116673