Hanford spent nuclear fuel cold vacuum drying proof of performance test procedure
This document provides the test procedure for cold testing of the first article skids for the Cold Vacuum Drying (CVD) process at the Facility. The primary objective of this testing is to confirm design choices and provide data for the initial start-up parameters for the process. The current scope of testing in this document includes design verification, drying cycle determination equipment performance testing of the CVD process and MCC components, heat up and cool-down cycle determination, and thermal model validation.
- Research Organization:
- Fluor Daniel Hanford, Inc., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 353312
- Report Number(s):
- HNF-2402; ON: DE99050715; BR: EW7040000; TRN: AHC29923%%144
- Resource Relation:
- Other Information: PBD: 10 Jun 1998
- Country of Publication:
- United States
- Language:
- English
Similar Records
Hanford spent nuclear fuel cold vacuum drying process equipment skid modification work plan
Cold vacuum drying proof of performance (first article testing) test results
Hanford spent nuclear fuel cold vacuum drying test specification and test plan
Technical Report
·
Mon May 04 00:00:00 EDT 1998
·
OSTI ID:353312
Cold vacuum drying proof of performance (first article testing) test results
Technical Report
·
Wed Jun 23 00:00:00 EDT 1999
·
OSTI ID:353312
Hanford spent nuclear fuel cold vacuum drying test specification and test plan
Technical Report
·
Wed Jul 10 00:00:00 EDT 1996
·
OSTI ID:353312