Title: Comparison of Coriolis and turbine-type flowmeters for fuel measurement in gas turbine testing

Journal Article · · Journal of Engineering for Gas Turbines and Power
DOI:https://doi.org/10.1115/1.2812761· OSTI ID:31909
;  [1]
  1. National Research Council, Ottawa, Ontario (Canada)

The Machinery and Engine Technology (MET) Program of the National Research Council of Canada (NRCC) has established a program for the evaluation of sensors to measure gas turbine engine performance accurately. The precise measurement of fuel flow is an essential part of steady-state gas turbine performance assessment. The MET Laboratory has critically examined two types of fuel flowmeters, Coriolis and turbine. The two flowmeter types are different in that the Coriolis flowmeter measures mass flow directly, while the turbine flowmeter measures volumetric flow, which must be converted to mass flow for conventional performance analysis. The direct measurement of mass flow, using a Coriolis flowmeter, has many advantages in field testing of gas turbines, because it reduces the risk of errors resulting from the conversion process. Turbine flowmeters, on the other hand, have been regarded as an industry standard because they are compact, rugged, reliable, and relatively inexpensive. This paper describes the project objectives, the experimental installation, and the results of the comparison of the Coriolis and turbine-type flowmeters in steady-state performance testing. Discussed are variations between the two types of flowmeters due to fuel characteristics, fuel handling equipment, acoustic and vibration interference, and installation effects. Also included in this paper are estimations of measurement uncertainties for both types of flowmeter. Results indicate that the agreement between Coriolis and turbine-type flowmeters is good over the entire steady-state operating range of a typical gas turbine engine. In some cases the repeatability of the Coriolis flowmeter is better than the manufacturer`s specification. Even a significant variation in fuel density (10 percent), and viscosity (300 percent) did not appear to compromise the ability of the Coriolis flowmeter to match the performance of the turbine flowmeter.

Sponsoring Organization:
USDOE
OSTI ID:
31909
Report Number(s):
CONF-930502-; ISSN 0742-4795; TRN: IM9517%%204
Journal Information:
Journal of Engineering for Gas Turbines and Power, Vol. 117, Issue 1; Conference: 38. ASME international gas turbine and aeroengine congress and exhibition, Cincinnati, OH (United States), 24-27 May 1993; Other Information: PBD: Jan 1995
Country of Publication:
United States
Language:
English

Similar Records

Proving Coriolis flowmeters
Conference · Fri Dec 01 00:00:00 EST 1995 · OSTI ID:31909

Using turbine flowmeters to measure multiphase flow
Conference · Tue Jul 01 00:00:00 EDT 1997 · OSTI ID:31909

Advanced Hydrogen Turbine Development
Technical Report · Tue Jan 01 00:00:00 EST 2008 · OSTI ID:31909