W-026, acceptance test report imaging passive/active neutron(IPAN) (submittal {number_sign}54.3 - C3)
In the Spring of 1996, Site Acceptance Tests were performed for the 2 Imaging Passive/Active Neutron (IPAN) assay systems installed in the WRAP I Facility. This report includes the test documentation and the completed test checklists, with comments and resolutions. All testing was completed, with comments resolved by August 1996.
- Research Organization:
- Fluor Daniel Hanford, Inc., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 289379
- Report Number(s):
- HNF-SD-W026-ATR-023; ON: DE98059611; BR: 39EW31300; CNN: DE-AC06-96RL13200; TRN: 97000107
- Resource Relation:
- Other Information: PBD: 21 Feb 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
W-026 acceptance test plan plant control system software (submittal {number_sign} 216)
W-026 acceptance test plan plant control system hardware (submittal {number_sign} 216)
W-026 acceptance test report plant control system hardware (submittal {number_sign} 220.C)