Title: Inspection of thermal aging of primary piping systems in nuclear power plants with SQUID magnetometer

Book ·
OSTI ID:277824
; ;  [1]
  1. Nuclear Fuel Industries Ltd., Osaka (Japan)

Superconducting quantum interference device (SQUID) was used for the detection of thermal aging of duplex stainless steels. It was found that the SQUID output signal pattern in the presence of AC magnetic field applied to the specimen was sensitive to the material property changes due to thermal aging at the operating temperature of light water reactors. Besides, the change in the SQUID output was more significant as the unaged specimens had more ferrite content.

OSTI ID:
277824
Report Number(s):
CONF-960306-; ISBN 0-7918-1226-X; TRN: 96:018233
Resource Relation:
Conference: ICONE 4: ASME/JSME international conference on nuclear engineering, New Orleans, LA (United States), 10-13 Mar 1996; Other Information: PBD: 1996; Related Information: Is Part Of ICONE-4: Proceedings. Volume 5: Radioactive waste disposal; Decontamination and decommissioning; Aging assessment and license renewals; Global advances in nuclear codes and standards; Major component reliability; Rao, A.S. [ed.] [General Electric Nuclear Energy, San Jose, CA (United States)]; Duffey, R.B. [ed.] [Brookhaven National Lab., Upton, NY (United States)]; Elias, D. [ed.] [Commonwealth Edison, Downers Grove, IL (United States)]; PB: 525 p.
Country of Publication:
United States
Language:
English