skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Minimum critical masses and their uncertainties for several fissile nuclides and reflectors - 14296

Conference ·
OSTI ID:23100823
 [1]
  1. Nuclear Research and consultancy Group, NRG, P.O. Box 25, 1755 ZG Petten (Netherlands)

A systematic effort was undertaken to reevaluate the minimum critical mass for several fissile nuclides and reflectors. This was done using MCNP6 in combination with several modern nuclear data libraries, viz. ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1.1. This combination was benchmarked extensively against criticality safety benchmarks. The procedure to extract the minimum critical mass from the MCNP6 calculations was carefully implemented, so that it would have a negligible impact on the accuracy of the end results. All parts of the calculation, i.e. nuclear data processing, MCNP6 models, and post-processing, were applied consistently for all cases, involving varying fissile nuclides and reflectors. Results for the minimum critical mass were generated for {sup 233,235}U, {sup 236,239,241}Pu, {sup 242m}Am, {sup 243,245,247}Cm, and {sup 249,251}Cf, for the case of water moderation and water reflection. For {sup 235}U, the minimum critical mass was also calculated for cases with other reflectors, such as beryllium, heavy water, graphite, lead, and concrete. The results for the water reflection cases are in good agreement with most of the literature values, but for the cases with reflectors such as graphite, lead, or concrete, there are sizable differences. The accuracy of the results was assessed in two ways. First, a comparison was made with criticality safety benchmark results, by selecting benchmarks that resemble the minimum mass systems the most. It was clear that for {sup 233,235}U and {sup 239}Pu with water reflection, the differences in minimum critical masses between the libraries are consistent with the differences obtained for benchmark cases. The difference between the benchmark calculations and the benchmark values is then an indication of the accuracy with which one can simulate comparable systems. Secondly, sensitivity runs were performed with the new MCNP6 sensitivity option, based on ENDF/B-VII.1 nuclear data. For each fissile nuclide, the sensitivity of k{sub eff} to cross sections such as capture, fission, elastic, inelastic was calculated for the minimum critical mass case. The same was done for the {sup 1}H and {sup 16}O cross sections in the moderator and reflector. The uncertainty in k{sub eff} was calculated by combining the sensitivity profiles with the appropriate ENDF/B-VII.1 covariance matrix, using the SUSD code. As a final step, the uncertainty in k{sub eff} can be translated to an uncertainty in the minimum critical mass. (author)

Research Organization:
American Nuclear Society - ANS, 555 North Kensington Avenue, La Grange Park, IL 60526 (United States)
OSTI ID:
23100823
Resource Relation:
Conference: ICNC 2015: 2015 International Conference on Nuclear Criticality Safety, Charlotte, NC (United States), 13-17 Sep 2015; Other Information: Country of input: France; 13 refs.; available on CD Rom from American Nuclear Society - ANS, 555 North Kensington Avenue, La Grange Park, IL 60526 (US)
Country of Publication:
United States
Language:
English