This paper discusses the use of the integrated system failure analysis (ISFA) technique for fault diagnosis for the holdup tank system. ISFA is a simulation-based, qualitative and integrated approach used to study fault propagation in systems containing both hardware and software subsystems. The holdup tank system consists of a tank containing a fluid whose level is controlled by an inlet valve and an outlet valve. We introduce the component and functional models of the system, quantify the main parameters and simulate possible failure-propagation paths based on the fault propagation approach, ISFA. The results show that most component failures in the holdup tank system can be identified clearly and that ISFA is viable as a technique for fault diagnosis. Since ISFA is a qualitative technique that can be used in the very early stages of system design, this case study provides indications that it can be used early to study design aspects that relate to robustness and fault tolerance. (authors)

OSTI ID:
23042735
Journal Information:
Transactions of the American Nuclear Society, Vol. 115; Conference: 2016 ANS Winter Meeting and Nuclear Technology Expo, Las Vegas, NV (United States), 6-10 Nov 2016; Other Information: Country of input: France; 2 refs.; available from American Nuclear Society - ANS, 555 North Kensington Avenue, La Grange Park, IL 60526 (US); ISSN 0003-018X
Country of Publication:
United States
Language:
English