skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Diamond as a solid state micro-fission chamber for thermal neutron detection at the VR-1 research reactor

Conference ·
OSTI ID:22531348
;  [1];  [2]; ; ;  [3]
  1. CEA-LIST, Diamond Sensors Laboratory, 91191, Gif-sur-Yvette (France)
  2. CEA, National Institute for Nuclear Science and Technology, 91191, Gif-sur-Yvette (France)
  3. Department of Nuclear Reactors,Faculty of Nuclear Science and Physical Engineering, Czech Technical University, V. Holesovickach 2, 180 00 PRAHA 8 (Czech Republic)

Diamond exhibits a combination of properties which makes it attractive for neutron detection in hostile conditions. In the particular case of detection in a nuclear reactor, it is resilient to radiation, exhibits a natural low sensitivity to gamma rays, and its small size (as compared with that of gas ionisation chambers) enables fluency monitoring with a high position resolution. We report here on the use of synthetic CVD diamond as a solid state micro-fission chamber with U-235 converting material for in-core thermal neutron monitoring. Two types of thin diamond detectors were developed for this application. The first type of detector is fabricated using thin diamond membrane obtained by etching low-cost commercially available single crystal CVD intrinsic diamond, so called 'optical grade' material. Starting from a few hundred of micrometre thick samples, the sample is sliced with a laser and then plasma etched down to a few tenths of micrometre. Here we report the result obtained with a 17 μm thick device. The detection surface of this detector is equal to 1 mm{sup 2}. Detectors with surfaces up to 1 cm{sup 2} can be fabricated with this technique. The second type of detector is fabricated by growing successively two thin films of diamond, by the microwave enhanced chemical vapour deposition technique, on HPHT single crystal diamond. A first, a film of boron doped (p+) single crystal diamond, a few microns thick, is deposited. Then a second film of intrinsic diamond with a thickness of a few tens of microns is deposited. This results in a P doped, Intrinsic, Metal structure (PIM) structure in which the intrinsic volume id the active part of the detector. Here we report the results obtained with a 20 μm thick intrinsic whose detection surface is equal to 0.5 mm{sup 2}, with the possibility to enlarge the surface of the detector up to 1 cm{sup 2}. These two types of detector were tested at the VR-1 research reactor at the Czech Technical University in Prague. The Training Reactor VR-1 is a pool type (light water) reactor based on UO{sub 2} low enriched uranium. It has a nominal power of 1 kW, and can be operated for a short period up to 5 kW. The arrangement of the reactor pool reactor facilitates access to the core, setting and removal of various experimental samples and detectors, and safe and easy handling of fuel assemblies. The reactor is equipped with two horizontal channels (radial and tangential) and 10 vertical channels, of varying diameters, which can be loaded into various core positions, and one pneumatic transfer system. It is also equipped with several specifically designed educational instrumentation systems that can be used to supply complementary measurements and characterization around the reactor. The reactor is operated by the Department of Nuclear Reactors of the Faculty of Nuclear Sciences and Physical Engineering of the Czech Technical University in Prague. The two detectors were placed in-core through one of the vertical insertion channel. They were coupled to remote placed (5 m BNC cable) classical nuclear charge sensitive electronics. Detection properties of both sensors, including: pulse height spectra of U-235 fission fragments (response linearity with neutron flux, count rate, gamma background, were evaluated varying the power of the reactor from 0.005 W to 500 W. The evolution of the counting rate of the thinned optical grade detector as a function of counting rate of a gas ionization chamber used currently for reactor monitoring shows the very good linearity of the detector over the 5 decades. Similar results were obtained with the PIM detector. Additionally fast transient current signals of the detectors were recorded on a digital storage oscilloscope (DSO) using broad-band amplifier and with a simple bias-T, showing potential use of such sensors for neutron counting with no need of an amplification stage, since non-amplified signals from fission fragments exceeded 4 mV in amplitude. Therefore, one can think of simple neutron counting system by feeding diamond detectors signals directly to the low threshold discriminators. The results obtained on the VR1 will be described and discussed in detail in the paper and associated presentation. The results demonstrate that diamond micro-fission chambers can be used for in-core neutron monitoring, where robust, simple and compact devices are required.

Research Organization:
Institute of Electrical and Electronics Engineers - IEEE, 3 Park Avenue, 17th Floor, New York, N.Y. 10016-5997 (United States)
OSTI ID:
22531348
Report Number(s):
ANIMMA-2015-IO-300; TRN: US16V0472102289
Resource Relation:
Conference: ANIMMA 2015: 4. International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications, Lisboa (Portugal), 20-24 Apr 2015; Other Information: Country of input: France
Country of Publication:
United States
Language:
English