A Mobile Automated Tomographic Gamma Scanning System - 13231
- Canberra Industries, Inc. 800 Research Parkway, Meriden CT 06450 (United States)
Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)
- Research Organization:
- WM Symposia, 1628 E. Southern Avenue, Suite 9-332, Tempe, AZ 85282 (United States)
- OSTI ID:
- 22224984
- Report Number(s):
- INIS-US-13-WM-13231; TRN: US14V0433045939
- Resource Relation:
- Conference: WM2013: Waste Management Conference: International collaboration and continuous improvement, Phoenix, AZ (United States), 24-28 Feb 2013; Other Information: Country of input: France; 7 refs.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Recent Advancements in Tomographic Gamma Scanning for Non- Destructive Assay - 17321
High Resolution Scanning Configurations for the Canberra Tomographic Gamma Scanner - 17323
Related Subjects
12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
CALIBRATION
CARGO
COBALT 60
COMPUTER CODES
CONCRETES
CONTAINERS
DATA ACQUISITION
DENSITY
EUROPIUM 152
GAMMA SPECTROSCOPY
IMAGE PROCESSING
KEV RANGE 01-10
LANL
MEV RANGE 01-10
SPATIAL RESOLUTION
THREE-DIMENSIONAL CALCULATIONS
TRANSMISSION
TRANSPORT
VERIFICATION
WASTES