Title: Characteristics of elliptical sources in BEAMnrc Monte Carlo system: Implementation and application

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.3086110· OSTI ID:22095307
 [1]
  1. Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States)

Recently, several papers noticed that the electron focal spot of a linear accelerator (linac) could be elliptical which would cause dosimetric discrepancies between measurements and Monte Carlo simulations. To resolve the mismatch, two elliptical source models were developed in BEAMnrc code. The first was a parallel beam elliptical source with uniform distribution where the shape of the source was primarily considered. The other was a parallel beam elliptical source with Gaussian distribution whose source distribution follows the normal distribution. To validate the elliptical source models, uniform and Gaussian electron beams were impinged on a thin air target. Both models successfully reproduced the elliptical shapes and source distributions. Then, this study investigated the characteristics of the elliptical Gaussian source for a 6 MV photon beam in a Varian 21EX linac. The linac head model was implemented in the BEAMnrc/EGSnrc system and commissioned by comparing the lateral and depth dose profiles to the ion chamber measurements acquired from the annual quality assurance (QA). It was found that the circular Gaussian beam with 6 MeV/0.2 cm full width half maximum (FWHM) produces the best matches to the QA data. To explore the characteristics of the elliptical Gaussian source, this study employed an elliptical Gaussian electron source with 0.1 cm FWHM in the x axis and 0.2 cm FWHM in the y axis which was incident on the target of the linac head. Two circular Gaussian beams with 0.1 and 0.2 cm FWHM were employed to compare the differences between circular and elliptical sources. For all the sources, planar and energy fluences were acquired and analyzed. This study also compared the lateral and depth dose profiles in a water phantom by using a DOSXYZnrc user code. In results, a constricted shoulder effect was observed in both planar and energy fluence plots when the FWHM value was increased and the field size is larger than 30x30 cm{sup 2}. The same effect was also noticed in the lateral dose profiles, while the depth dose profile did not vary much.

OSTI ID:
22095307
Journal Information:
Medical Physics, Vol. 36, Issue 4; Other Information: (c) 2009 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English