Space-resolved extreme ultraviolet spectrometer for impurity emission profile measurement in Large Helical Device
- Department of Fusion Science, Graduate University for Advanced Studies, Toki, Gifu 509-5292 (Japan)
- National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan)
A space-resolved extreme ultraviolet (EUV) spectrometer working in 60-400 A range has been developed to observe impurity emission profiles in core and edge plasmas of Large Helical Device (LHD). A flat focus is made for plane surface detector by using a varied line spacing holographic grating with an angle of incidence of 87 deg. An excellent spectral resolution of 0.22 A at 200 A is then obtained after careful adjustment of the optical components. In the profile measurement of the LHD plasmas, the toroidal resolution is important as well as the radial resolution because the magnetic surfaces of LHD quickly change when the observation chord is tilted at a slightly different toroidal location. Horizontal dispersion is therefore selected for the present spectrometer. As a result, the toroidal resolution of 75 mm is achieved at the plasma position. An enough radial resolution of 10 mm is also obtained at spatial-resolution slit width of 0.2 mm. In order to measure the full radial profile of LHD plasmas the spectrometer is placed at a distance of {approx}9200 mm away from the plasma center and a backilluminated charge-coupled device with a size of 6.6x26.6 mm{sup 2} is set vertical to the horizontal dispersion. Half of the LHD plasma, i.e., {approx}50 cm, can be measured along the vertical direction at horizontally elongated plasma cross section. A full vertical profile can be obtained by changing the vertical angle of the EUV spectrometer. As an example the full vertical profile of edge C IV (312.4 A) emission is presented. A wavelength interval of 35-65 A can be simultaneously observed, which varies according to the wavelength to be measured. A local emission profile of Fe XX (132.67 A) is also presented after Abel inversion as a typical example of the core EUV emission. Finally, the EUV spectrometer is absolutely calibrated using EUV bremsstrahlung continuum profile in comparison with absolute values of visible bremsstrahlung continuum profile because the bremsstrahlung continuum can be easily detected in high-density discharges of LHD.
- OSTI ID:
- 22053939
- Journal Information:
- Review of Scientific Instruments, Vol. 81, Issue 3; Other Information: (c) 2010 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
- Country of Publication:
- United States
- Language:
- English
Similar Records
Z{sub eff} measurement using extreme ultraviolet bremsstrahlung emission in LHD
Space-resolved extreme ultraviolet spectroscopy free of high-energy neutral particle noise in wavelength range of 10–130 Å on the large helical device
Related Subjects
70 PLASMA PHYSICS AND FUSION TECHNOLOGY
BREMSSTRAHLUNG
CHARGE-COUPLED DEVICES
EXTREME ULTRAVIOLET RADIATION
GRATINGS
HOLOGRAPHY
INCIDENCE ANGLE
LHD DEVICE
MAGNETIC SURFACES
PLASMA
SPATIAL RESOLUTION
ULTRAVIOLET SPECTROMETERS
VISIBLE RADIATION
WAVELENGTHS