skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Refraction Contrast Imaging by Using MIRRORCLE-Type Tabletop Synchrotron

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2723638· OSTI ID:21056939
; ;  [1];  [1]; ;  [2]
  1. Faculty of science and Engineering, Ritsumeikan University, Kusatsu, Shiga, 525-8577 (Japan)
  2. Photon Production Laboratory Ltd, Omihachiman, Shiga, 523-0898 (Japan)

MIRRORCLE type tabletop synchrotron is suitable for magnified hard x-ray imaging due to its micron size x-ray source, wide radiation angle, x-ray spectrum ranging from a few keV to 6 MeV and high flux output. It is known that the magnified imaging by a micron size x-ray source provides a high spatial resolution image, and a sharply enhanced edge effect for weakly absorbing objects. This x-ray imaging technique is known as a phase-contrast imaging. In this work, we performed a phase contrast imaging of a simple shape objects using an imaging plate for studying the characteristics of the edge enhancement by MIRRORCLE. It turns out that the edge effect is enhanced for higher magnification and smaller source size. The characteristics of the edge effect can be explained by using the refraction effect. Furthermore, the refraction contrast is enhanced when the imaging system resolution is decreased. By using MIRRORCLE, we can obtain refractive-contrast images of objects as large as human. The magnified x-ray imaging capabilities of MIRRORCLE are a great advantage to medical imaging and NDI of organic objects.

OSTI ID:
21056939
Journal Information:
AIP Conference Proceedings, Vol. 902, Issue 1; Conference: 2. international symposium on portable synchrotron light sources and advanced applications, Shiga (Japan), 15-17 Jan 2007; Other Information: DOI: 10.1063/1.2723638; (c) 2007 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Medical X-ray Imaging by MIRRORCLE-6X
Journal Article · Fri Mar 30 00:00:00 EDT 2007 · AIP Conference Proceedings · OSTI ID:21056939

Development of 3D-CT System Using MIRRORCLE-6X
Journal Article · Fri Mar 30 00:00:00 EDT 2007 · AIP Conference Proceedings · OSTI ID:21056939

Characterization of an x-ray phase contrast imaging system based on the miniature synchrotron MIRRORCLE-6X
Journal Article · Thu Sep 15 00:00:00 EDT 2011 · Medical Physics · OSTI ID:21056939