Title: Target Volume Delineation for Partial Breast Radiotherapy Planning: Clinical Characteristics Associated with Low Interobserver Concordance

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1]; ; ;  [1];  [2];  [1];  [2];  [1]
  1. Radiation Therapy Program, British Columbia Cancer Agency, Vancouver Island Centre and University of British Columbia, Victoria, BC (Canada)
  2. Radiation Therapy Program, British Columbia Cancer Agency, Vancouver Island Centre and University of Victoria, Victoria, BC (Canada)

Purpose: To examine variability in target volume delineation for partial breast radiotherapy planning and evaluate characteristics associated with low interobserver concordance. Methods and Materials: Thirty patients who underwent planning CT for adjuvant breast radiotherapy formed the study cohort. Using a standardized scale to score seroma clarity and consensus contouring guidelines, three radiation oncologists independently graded seroma clarity and delineated seroma volumes for each case. Seroma geometric center coordinates, maximum diameters in three axes, and volumes were recorded. Conformity index (CI), the ratio of overlapping volume and encompassing delineated volume, was calculated for each case. Cases with CI {<=}0.50 were analyzed to identify features associated with low concordance. Results: The median time from surgery to CT was 42.5 days. For geometric center coordinates, variations from the mean were 0.5-1.1 mm and standard deviations (SDs) were 0.5-1.8 mm. For maximum seroma dimensions, variations from the mean and SDs were predominantly <5 mm, with the largest SDs observed in the medial-lateral axis. The mean CI was 0.61 (range, 0.27-0.84). Five cases had CI {<=}0.50. Conformity index was significantly associated with seroma clarity (p < 0.001) and seroma volume (p < 0.002). Features associated with reduced concordance included tissue stranding from the surgical cavity, proximity to muscle, dense breast parenchyma, and benign calcifications that may be mistaken for surgical clips. Conclusion: Variability in seroma contouring occurred in three dimensions, with the largest variations in the medial-lateral axis. Awareness of clinical features associated with reduced concordance may be applied toward training staff and refining contouring guidelines for partial breast radiotherapy trials.

OSTI ID:
21036196
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 69, Issue 1; Other Information: DOI: 10.1016/j.ijrobp.2007.01.070; PII: S0360-3016(07)00532-9; Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Clinical Applicability of Cone-Beam Computed Tomography in Monitoring Seroma Volume Change During Breast Irradiation
Journal Article · Wed Sep 01 00:00:00 EDT 2010 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21036196

Improvement in Interobserver Accuracy in Delineation of the Lumpectomy Cavity Using Fiducial Markers
Journal Article · Mon Nov 15 00:00:00 EST 2010 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21036196

3D Ultrasound Can Contribute to Planning CT to Define the Target for Partial Breast Radiotherapy
Journal Article · Sun Feb 01 00:00:00 EST 2009 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21036196